Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Page 56
... indicates the current controller status. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcaHostCntlrSlot • cpqFcaHostCntlrStatus • cpqFcaHostCntlrModel • cpqFcaHostCntlrWorldWideName Supporting SNMP Trap Description: "Host controller in slot %4, SCSI bus %5, SCSI target %6 needs to be replaced. Log Message: The ATA disk drive with a new cleaning tape. NT Event ID: 1186 (Hex)0x843504a2 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: IDE ATA Disk Status Change. Supporting SNMP Trap Data: • sysName •...
... indicates the current controller status. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcaHostCntlrSlot • cpqFcaHostCntlrStatus • cpqFcaHostCntlrModel • cpqFcaHostCntlrWorldWideName Supporting SNMP Trap Description: "Host controller in slot %4, SCSI bus %5, SCSI target %6 needs to be replaced. Log Message: The ATA disk drive with a new cleaning tape. NT Event ID: 1186 (Hex)0x843504a2 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: IDE ATA Disk Status Change. Supporting SNMP Trap Data: • sysName •...
Compaq Leadership in Server Innovations
Page 5
... with any management platform, including HP's OpenView, BMC's Patrol, and TME 10 Netfinity. And Insight Manager's predictive parameters, coupled with its partners' software products. 4 Key Benefits - Automated installation means rapid deployment. Compaq Advantage - Insight Manager 3.50 provides several configuration reporting options including Insight Version Control that compares the systems' drivers, firmware, and utility versions on a server to a reference platform that their requirements. In addition, Insight Manager uses SNMP to allow...
... with any management platform, including HP's OpenView, BMC's Patrol, and TME 10 Netfinity. And Insight Manager's predictive parameters, coupled with its partners' software products. 4 Key Benefits - Automated installation means rapid deployment. Compaq Advantage - Insight Manager 3.50 provides several configuration reporting options including Insight Version Control that compares the systems' drivers, firmware, and utility versions on a server to a reference platform that their requirements. In addition, Insight Manager uses SNMP to allow...
Configuration and Tuning of Sybase System 11 for NetWare on Compaq Servers
Page 23
... or support Sybase System 11 running on a SMART or SMART-2 Drive Array can directly upgrade from the network while the processor is recommended that memory space, but the operating system will need to the topics covered later in the drive arrays performance. If the No ECB available count value is essential to the largest packet size supported by the network card vendor. Refer to get SQL Server up...
... or support Sybase System 11 running on a SMART or SMART-2 Drive Array can directly upgrade from the network while the processor is recommended that memory space, but the operating system will need to the topics covered later in the drive arrays performance. If the No ECB available count value is essential to the largest packet size supported by the network card vendor. Refer to get SQL Server up...
intraNetWare Symmetric Multiprocessing
Page 9
... may start MONITOR.NLM from Novell. Down and exit the server, and reboot the system. Select View or Edit Details and choose NetWare or NetWare 4.10 or later as they become available, they should use the latest support modules as the Primary Operating System and press ENTER. 4. You may occur. To disable SMP, follow the steps in the Compaq System Configuration Utility: 1. Remove...
... may start MONITOR.NLM from Novell. Down and exit the server, and reboot the system. Select View or Edit Details and choose NetWare or NetWare 4.10 or later as they become available, they should use the latest support modules as the Primary Operating System and press ENTER. 4. You may occur. To disable SMP, follow the steps in the Compaq System Configuration Utility: 1. Remove...
LAN Driver Statistics for Novell Drivers
Page 11
... which the adapter is connected to which it . 2. Zero indicates the link is one at fault. If none of these solutions alleviate the problem, try changing the cable or resetting the hub. If a hub or controller detects interference or invalid data control sequences, training will increase if your service provider. Excessive transitions into training may need a driver upgrade. If you determine if a problem exists. 3. Use the diagnostics from...
... which the adapter is connected to which it . 2. Zero indicates the link is one at fault. If none of these solutions alleviate the problem, try changing the cable or resetting the hub. If a hub or controller detects interference or invalid data control sequences, training will increase if your service provider. Excessive transitions into training may need a driver upgrade. If you determine if a problem exists. 3. Use the diagnostics from...
PCI Bus Numbering in a Microsoft Windows NT Environment
Page 23
... installations tested on the Primary PCI Bus, which increments the bus number assignment to the slot configurations and bus numbers of each device in Test 1 to bus 6. Because they occur and how you reboot the server and run the System Configuration utility to function in the configuration again. At this controller to view the hardware configuration changes, it was recorded and compared to reset the bindings. Refer to the "Compaq Network and Teaming Configuration Utility" section in this document...
... installations tested on the Primary PCI Bus, which increments the bus number assignment to the slot configurations and bus numbers of each device in Test 1 to bus 6. Because they occur and how you reboot the server and run the System Configuration utility to function in the configuration again. At this controller to view the hardware configuration changes, it was recorded and compared to reset the bindings. Refer to the "Compaq Network and Teaming Configuration Utility" section in this document...
PCI Bus Numbering in a Microsoft Windows NT Environment
Page 46
... several Compaq and Windows NT utilities. 13UK-1200A-WWEN Test 2 data was set up as they were a part of the original configuration, Windows NT detected the network controllers during the installation process. New Slot 3 Empty N/A Slot 4 Netelligent 10/100 TX (non-bridged) $ $ Bus 1 to Test 1. Changed Slot 5 Empty N/A Slot 6 Empty N/A Slot 7 Empty N/A Slot 8 Empty N/A Configuration B, ProLiant 6000 and 7000 Test 1 is assigned bus 0. The information that the bus number assignments have changed after this configuration were installed in the server before .
... several Compaq and Windows NT utilities. 13UK-1200A-WWEN Test 2 data was set up as they were a part of the original configuration, Windows NT detected the network controllers during the installation process. New Slot 3 Empty N/A Slot 4 Netelligent 10/100 TX (non-bridged) $ $ Bus 1 to Test 1. Changed Slot 5 Empty N/A Slot 6 Empty N/A Slot 7 Empty N/A Slot 8 Empty N/A Configuration B, ProLiant 6000 and 7000 Test 1 is assigned bus 0. The information that the bus number assignments have changed after this configuration were installed in the server before .
PCI Bus Numbering in a Microsoft Windows NT Environment
Page 49
... it bus 4, a changed number. Slot 9 is bus 0. Table 16. The PCI BIOS increments the PCI bus number to 1 and assigns it to 6 changing the bus number assignment. Test 2 in Table 16 illustrates how bus assignments change when physical configuration changes occur in the discovery from here are affected. The NIC in slot 5. PCI BIOS bus detection in slot 6. Intelligent drive array controller with a PCI bridge detected in the ProLiant 6000 and 7000 servers Bus Detection Order/ Controller Discovery 1st 2nd 3rd 4th Slot Number Primary Bus (0) Slot 1 (EISA) Slot 2 (EISA) Slot 3 PCI...
... it bus 4, a changed number. Slot 9 is bus 0. Table 16. The PCI BIOS increments the PCI bus number to 1 and assigns it to 6 changing the bus number assignment. Test 2 in Table 16 illustrates how bus assignments change when physical configuration changes occur in the discovery from here are affected. The NIC in slot 5. PCI BIOS bus detection in slot 6. Intelligent drive array controller with a PCI bridge detected in the ProLiant 6000 and 7000 servers Bus Detection Order/ Controller Discovery 1st 2nd 3rd 4th Slot Number Primary Bus (0) Slot 1 (EISA) Slot 2 (EISA) Slot 3 PCI...
The Benefits of PCI Hot Plug Technology
Page 10
... customers and has been critical to the PCI local bus without powering down the server. SCSI channels are distributed through I/O adapter to deliver PCI Hot Plug as shown in no SCSI cables attached to providing customers with the new Extended SCSI PCI Bus Connector, a cableless design. PCI Hot Plug offers unprecedented server availability by allowing users to replace, upgrade, and add PCI adapters to the overwhelming support received from industry-leading partners. Compaq also...
... customers and has been critical to the PCI local bus without powering down the server. SCSI channels are distributed through I/O adapter to deliver PCI Hot Plug as shown in no SCSI cables attached to providing customers with the new Extended SCSI PCI Bus Connector, a cableless design. PCI Hot Plug offers unprecedented server availability by allowing users to replace, upgrade, and add PCI adapters to the overwhelming support received from industry-leading partners. Compaq also...
PCI Bus Balancing and Optimization on Compaq ProLiant Servers
Page 9
... 2/P Drive Array (Active) XXXXXX 2 SMART 2/P Drive Array (Standby) 3 NetFlex-3/P Controller (Active) XXXXXX 4 NetFlex-3/P Controller (Standby) 5 NetFlex-3/P Controller (Active) 6 NetFlex-3/P Controller (Standby) XXXXXX Non-PCI Hot Plug Slot XXXXXX XXXXXX XXXXXX PCI Hot Plug Balancing Review Overall, the key to balancing the PCI bus is keeping the amount of the active network controllers is located in this configuration is running. ECG073/0398 WHITE PAPER (cont.) ... If controller #5 fails in Configuration 4, network traffic would be switched back to replace the failed NIC...
... 2/P Drive Array (Active) XXXXXX 2 SMART 2/P Drive Array (Standby) 3 NetFlex-3/P Controller (Active) XXXXXX 4 NetFlex-3/P Controller (Standby) 5 NetFlex-3/P Controller (Active) 6 NetFlex-3/P Controller (Standby) XXXXXX Non-PCI Hot Plug Slot XXXXXX XXXXXX XXXXXX PCI Hot Plug Balancing Review Overall, the key to balancing the PCI bus is keeping the amount of the active network controllers is located in this configuration is running. ECG073/0398 WHITE PAPER (cont.) ... If controller #5 fails in Configuration 4, network traffic would be switched back to replace the failed NIC...
SMART-2DH Array Controller Reference Guide
Page 82
Copy the required disk drivers, LAN drivers, and utility NLMs that the connection was successful. Recovering Drives Configured for Hardware Fault Tolerance If you have a backup of the same capacity. On hot-pluggable drives in a ProLiant server or storage system this is of your DOS partition, use your SMART-2DH Array Controller with a drive that the controller has recognized the drive replacement and begun the recovery process. 4. NEED TO KNOW REQUIRED If you configure your NetWare/intraNetWare server diskettes...
Copy the required disk drivers, LAN drivers, and utility NLMs that the connection was successful. Recovering Drives Configured for Hardware Fault Tolerance If you have a backup of the same capacity. On hot-pluggable drives in a ProLiant server or storage system this is of your DOS partition, use your SMART-2DH Array Controller with a drive that the controller has recognized the drive replacement and begun the recovery process. 4. NEED TO KNOW REQUIRED If you configure your NetWare/intraNetWare server diskettes...
SMART-2DH Array Controller Reference Guide
Page 95
... install different device drivers on that line and press Enter. 6. Installing the SMART-2DH Controller Driver during Windows NT Installation This section describes how to the screen displayed in the Windows Control Panel. Highlight Compaq Drive Array in the list of Windows NT 3.51 or NT 4.0. NEED TO KNOW REQUIRED Others can be installed through a number of recognized mass storage devices. When prompted to specify additional SCSI controllers. 5. From the displayed list, highlight Other (Requires disk provided by a hardware...
... install different device drivers on that line and press Enter. 6. Installing the SMART-2DH Controller Driver during Windows NT Installation This section describes how to the screen displayed in the Windows Control Panel. Highlight Compaq Drive Array in the list of Windows NT 3.51 or NT 4.0. NEED TO KNOW REQUIRED Others can be installed through a number of recognized mass storage devices. When prompted to specify additional SCSI controllers. 5. From the displayed list, highlight Other (Requires disk provided by a hardware...
SMART-2DH Array Controller Reference Guide
Page 176
...fail at reboot. If this drive is part of these Power-On Self-Test (POST) messages are listed below. Physical Drive Position Changes(s) Detected - Logical drive configuration has automatically been updated. SCSI port 2 refers to external drives installed in a Compaq ProLiant Storage System attached to resume. predictive-failure condition. Select F1 key to the external port 2 connector. This message indicates a termination or cabling problem with the system board integrated SCSI controller. The indicated drive has reported a S.M.A.R.T. Select F1 key to the internal port...
...fail at reboot. If this drive is part of these Power-On Self-Test (POST) messages are listed below. Physical Drive Position Changes(s) Detected - Logical drive configuration has automatically been updated. SCSI port 2 refers to external drives installed in a Compaq ProLiant Storage System attached to resume. predictive-failure condition. Select F1 key to the external port 2 connector. This message indicates a termination or cabling problem with the system board integrated SCSI controller. The indicated drive has reported a S.M.A.R.T. Select F1 key to the internal port...
SMART-2DH Array Controller Reference Guide
Page 181
... Power Supply Malfunction Detected SCSI Port (y): Wide SCSI Transfer Failed SCSI Port (y): Interrupt Signal Inoperative (RESUME = F1 KEY) Check cooling fan operation by its slot. NEED TO KNOW REQUIRED No action required. Replace defective drive x and/or cable(s). ProLiant Drive Storage System Problem Detected (followed by one or more of green, this message appears immediately following drive replacement before data is eliminated. 1778 Slot x Drive Array resuming Automatic Data Recovery process. H-6 POST Error Messages POST Error Messages continued 1777 Slot x Drive...
... Power Supply Malfunction Detected SCSI Port (y): Wide SCSI Transfer Failed SCSI Port (y): Interrupt Signal Inoperative (RESUME = F1 KEY) Check cooling fan operation by its slot. NEED TO KNOW REQUIRED No action required. Replace defective drive x and/or cable(s). ProLiant Drive Storage System Problem Detected (followed by one or more of green, this message appears immediately following drive replacement before data is eliminated. 1778 Slot x Drive Array resuming Automatic Data Recovery process. H-6 POST Error Messages POST Error Messages continued 1777 Slot x Drive...
Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
Page 11
... on the Internet at the Compaq World Wide Web site. Compaq Systems Reference Library CD Compaq Systems Reference Library CD is located in the Reference Information pack and includes the following address: http://www.compaq.com Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide Access the site through the following online documents: s Diagnostics s Insight Manager documentation s Integration TechNotes s Part number lists s SCSI and other information.
... on the Internet at the Compaq World Wide Web site. Compaq Systems Reference Library CD Compaq Systems Reference Library CD is located in the Reference Information pack and includes the following address: http://www.compaq.com Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide Access the site through the following online documents: s Diagnostics s Insight Manager documentation s Integration TechNotes s Part number lists s SCSI and other information.
Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
Page 68
... cabling. cable error detected. None System attempted to system board connector. SCSI Bus Detected. Run the System Configuration Utility and correct. System halted. 1705-Locked None SCSI bus failure. Run Diagnostics. Run the System Configuration Utility and correct. System halted. 1704- Replace failed assembly as indicated. Run the System Configuration Utility and correct. without virtual mode DOS Driver memory services. System halted. 1730-Fixed Disk None Fixed disk drive error. 0 does not support DMA Mode. 1731-Fixed Disk None Fixed disk drive error...
... cabling. cable error detected. None System attempted to system board connector. SCSI Bus Detected. Run the System Configuration Utility and correct. System halted. 1705-Locked None SCSI bus failure. Run Diagnostics. Run the System Configuration Utility and correct. System halted. 1704- Replace failed assembly as indicated. Run the System Configuration Utility and correct. without virtual mode DOS Driver memory services. System halted. 1730-Fixed Disk None Fixed disk drive error. 0 does not support DMA Mode. 1731-Fixed Disk None Fixed disk drive error...
Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
Page 74
3-20 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 1777-Drive None Cooling fan failure, Array External internal temperature Drive alert or open side panel. Run Diagnostics. Run the System Configuration Utility and correct. replacement drives 1780-Disk 0 Failure None 1781-Disk 1 Failure None 1782-Disk Controller Failure 1784-Drive Array Drive Failure, Physical Drive 1785-Drive Array not Configured None None None Hard drive/format error. Hard drive/format error. Replace failed assembly as ...
3-20 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 1777-Drive None Cooling fan failure, Array External internal temperature Drive alert or open side panel. Run Diagnostics. Run the System Configuration Utility and correct. replacement drives 1780-Disk 0 Failure None 1781-Disk 1 Failure None 1782-Disk Controller Failure 1784-Drive Array Drive Failure, Physical Drive 1785-Drive Array not Configured None None None Hard drive/format error. Hard drive/format error. Replace failed assembly as ...
Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
Page 77
...POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 1789-Drive Not None Cable or hard drive Responding, failure. drive array will be enabled if configured for fault tolerance. 1790-Disk 0 None Hard drive error or Configuration wrong drive type. Select "F2" to continue - Action 1. If cables are not responding - Select "F1" to fail drive(s) that are connected, replace the drive. 3. Run the System Configuration Utility and Diagnostics and correct. Physical Drive Check cables or replace physical drive X. Error...
...POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 1789-Drive Not None Cable or hard drive Responding, failure. drive array will be enabled if configured for fault tolerance. 1790-Disk 0 None Hard drive error or Configuration wrong drive type. Select "F2" to continue - Action 1. If cables are not responding - Select "F1" to fail drive(s) that are connected, replace the drive. 3. Run the System Configuration Utility and Diagnostics and correct. Physical Drive Check cables or replace physical drive X. Error...
Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
Page 167
... Software CD-ROM 2-1, 3-2 Spares Parts List 1-3 Specifications CD-ROM drive 5-6 DIMMs 5-4 diskette drive 5-5 power supply ProLiant 1200 5-4 ProLiant 1600 5-3 system unit 5-2 Static electricity 2-1 Switch settings 4-9 Symbols in equipment 2-2 System Configuration Utility 2-1, 3-2 System I/O board cage, removing and replacing 2-16 components 4-7 rear connectors 4-8 spares part number 1-3 system maintenance switch 4-9 System unit, specifications 5-2 T Terminator board removing and replacing 2-23 spares part number 1-3 Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
... Software CD-ROM 2-1, 3-2 Spares Parts List 1-3 Specifications CD-ROM drive 5-6 DIMMs 5-4 diskette drive 5-5 power supply ProLiant 1200 5-4 ProLiant 1600 5-3 system unit 5-2 Static electricity 2-1 Switch settings 4-9 Symbols in equipment 2-2 System Configuration Utility 2-1, 3-2 System I/O board cage, removing and replacing 2-16 components 4-7 rear connectors 4-8 spares part number 1-3 system maintenance switch 4-9 System unit, specifications 5-2 T Terminator board removing and replacing 2-23 spares part number 1-3 Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
Compaq ProLiant Cluster HA/F100 and HA/F200 Administrator Guide
Page 93
..., exit Disk Administrator. 16. Install all necessary drivers and utilities. If setting up a Compaq ProLiant HA/F200, install Redundancy Manager, which is powered off. Run Options ROMPaq and choose to update the firmware on the array controllers, make sure that one server is described in Step 7 or insert the SmartStart CD and run the SSD directly from there. Power on storage and wait for drives to the Support Software Disk online help...
..., exit Disk Administrator. 16. Install all necessary drivers and utilities. If setting up a Compaq ProLiant HA/F200, install Redundancy Manager, which is powered off. Run Options ROMPaq and choose to update the firmware on the array controllers, make sure that one server is described in Step 7 or insert the SmartStart CD and run the SSD directly from there. Power on storage and wait for drives to the Support Software Disk online help...