HP-UX DMI 2.0 Developer's Guide: HP-UX/HP 9000 Computers, HP-UX Desktop Management Interface
Page 7
... DmiListComponents 78 DmiListComponentsByClass 78 DmiListGroups 78 DmiListLanguages 78 Operation Functions 79 DmiAddRow 79 DmiDeleteRow 79 DmiGetAttribute 79 DmiGetMultiple 79 DmiSetAttribute 79 DmiSetMultiple 80 Database Administration Functions 80 DmiAddComponent 80 DmiAddGroup 80 DmiAddLanguage 80 DmiDeleteComponent 80 DmiDeleteGroup 81 DmiDeleteLanguage 81 Management Application Provider Functions 82 Indication Functions 82 DmiComponentAdded 82 DmiComponentDeleted 82 DmiDeliverEvent 82 7 Contents DmiGroupInfo 68...
... DmiListComponents 78 DmiListComponentsByClass 78 DmiListGroups 78 DmiListLanguages 78 Operation Functions 79 DmiAddRow 79 DmiDeleteRow 79 DmiGetAttribute 79 DmiGetMultiple 79 DmiSetAttribute 79 DmiSetMultiple 80 Database Administration Functions 80 DmiAddComponent 80 DmiAddGroup 80 DmiAddLanguage 80 DmiDeleteComponent 80 DmiDeleteGroup 81 DmiDeleteLanguage 81 Management Application Provider Functions 82 Indication Functions 82 DmiComponentAdded 82 DmiComponentDeleted 82 DmiDeliverEvent 82 7 Contents DmiGroupInfo 68...
HP-UX DMI 2.0 Developer's Guide: HP-UX/HP 9000 Computers, HP-UX Desktop Management Interface
Page 80
.... DmiErrorStatus_t DMI_API DmiSetMultiple( /* [in] */ DmiHandle_t handle, /* [in] */ DmiSetMode_t setMode, /* [in] */ DmiMultiRowData_t* rowData) Database Administration Functions The following functions modify the schema (data) in ] */ DmiId_t compId) 80 Chapter 9 DmiAddComponent() Adds a new component to an existing component in the MIF database. DmiErrorStatus_t DMI_API DmiAddGroup(" /* [in] */ DmiHandle_t handle, /* [in] */ DmiFileDataList_t* fileData, /* [in the MIF...
.... DmiErrorStatus_t DMI_API DmiSetMultiple( /* [in] */ DmiHandle_t handle, /* [in] */ DmiSetMode_t setMode, /* [in] */ DmiMultiRowData_t* rowData) Database Administration Functions The following functions modify the schema (data) in ] */ DmiId_t compId) 80 Chapter 9 DmiAddComponent() Adds a new component to an existing component in the MIF database. DmiErrorStatus_t DMI_API DmiAddGroup(" /* [in] */ DmiHandle_t handle, /* [in] */ DmiFileDataList_t* fileData, /* [in the MIF...
System Configuration Repository User's Reference: HP-UX/HP 9000 Computers, Edition 1.2
Page 80
... tagged with the time of the data in the specified file must be the same as that used by scrlog_viewer. /tmp/LFV_RUN 80 Reference If file is -, stdin is read data from which it , and save the result in the log entries read and scrlog_viewer runs non-interactively...
... tagged with the time of the data in the specified file must be the same as that used by scrlog_viewer. /tmp/LFV_RUN 80 Reference If file is -, stdin is read data from which it , and save the result in the log entries read and scrlog_viewer runs non-interactively...
hp 12x speed CD-ROM disk drive user's guide (a1658-90703)
Page 14
F to 95% RH (Non-Condensing) 1-4 C 8% to 80% RH (Non-Condensing) 5% to 140 deg. C to 122 deg. C (41 deg. C Non-Operating @ 60 deg. F) -10 deg. F to 60 deg. C (14 deg. F) • Altitude Operating Non-Operating 3000 m (10,000 ft.) 12000 m (40,000 ft.) • Humidity Operating @ 22 deg. Introduction CD-ROM Drive Environmental Requirements The CD-ROM drive has the following environmental requirements: • Temperature Operating Non-Operating 5 deg. C to 40 deg.
F to 95% RH (Non-Condensing) 1-4 C 8% to 80% RH (Non-Condensing) 5% to 140 deg. C to 122 deg. C (41 deg. C Non-Operating @ 60 deg. F) -10 deg. F to 60 deg. C (14 deg. F) • Altitude Operating Non-Operating 3000 m (10,000 ft.) 12000 m (40,000 ft.) • Humidity Operating @ 22 deg. Introduction CD-ROM Drive Environmental Requirements The CD-ROM drive has the following environmental requirements: • Temperature Operating Non-Operating 5 deg. C to 40 deg.
hp 4x speed CD-ROM disk drive user's guide (a1658-90669)
Page 14
C (41 deg. C Non-Operating @ 60 deg. F) -10 deg. F to 122 deg. C (14 deg. F to 140 deg. Introduction CD-ROM Drive Environmental Requirements The CD-ROM drive has the following environmental requirements: • Temperature Operating Non-Operating 5 deg. C to 60 deg. C to 50 deg. F) • Altitude Operating Non-Operating 3000 m (10000 ft.) 12000 m (40,000 ft.) • Humidity Operating @ 22 deg. C 8% to 80 %RH (Non-Condensing) 5% to 95 %RH (Non-Condensing) 1-4
C (41 deg. C Non-Operating @ 60 deg. F) -10 deg. F to 122 deg. C (14 deg. F to 140 deg. Introduction CD-ROM Drive Environmental Requirements The CD-ROM drive has the following environmental requirements: • Temperature Operating Non-Operating 5 deg. C to 60 deg. C to 50 deg. F) • Altitude Operating Non-Operating 3000 m (10000 ft.) 12000 m (40,000 ft.) • Humidity Operating @ 22 deg. C 8% to 80 %RH (Non-Condensing) 5% to 95 %RH (Non-Condensing) 1-4
hp 4x speed CD-ROM disk drive user's guide (a1658-90688)
Page 14
C to 95% RH (Non-Condensing) 1-4 F) • Altitude Operating Non-Operating 3000 m (10,000 ft.) 12000 m (40,000 ft.) • Humidity Operating @ 22 deg. C 8% to 80% RH (Non-Condensing) 5% to 60 deg. F to 140 deg. C Non-Operating @ 60 deg. C (14 deg. Introduction CD-ROM Drive Environmental Requirements The CD-ROM drive has the following environmental requirements: • Temperature Operating Non-Operating 5 deg. F to 122 deg. C (41 deg. C to 40 deg. F) -10 deg.
C to 95% RH (Non-Condensing) 1-4 F) • Altitude Operating Non-Operating 3000 m (10,000 ft.) 12000 m (40,000 ft.) • Humidity Operating @ 22 deg. C 8% to 80% RH (Non-Condensing) 5% to 60 deg. F to 140 deg. C Non-Operating @ 60 deg. C (14 deg. Introduction CD-ROM Drive Environmental Requirements The CD-ROM drive has the following environmental requirements: • Temperature Operating Non-Operating 5 deg. F to 122 deg. C (41 deg. C to 40 deg. F) -10 deg.
hp DDS-2 tape drive user's guide (a1658-90689)
Page 14
...features of the DDS-1 and DDS-DC formats. • Reads and writes with much higher capacity when using DDS-1 media (60 m and 90 m). Introduction DDS-2 Drive The HP C1533A implements the DDS-2 format. DDS-2 Drive Environmental Requirements The DDS-2 drive has the following environmental requirements: • Ambient Temperature...0 km to 4.6 km (0 to 15,000 ft) 0 km to 15.2 km (0 to 50,000 ft) • Humidity Operating Non-Operating 20% to 80%RH (non-condensing) 5% to read and write with much higher capacity as follows: • Reads and writes using DDS-1 and DDS-DC formats when using...
...features of the DDS-1 and DDS-DC formats. • Reads and writes with much higher capacity when using DDS-1 media (60 m and 90 m). Introduction DDS-2 Drive The HP C1533A implements the DDS-2 format. DDS-2 Drive Environmental Requirements The DDS-2 drive has the following environmental requirements: • Ambient Temperature...0 km to 4.6 km (0 to 15,000 ft) 0 km to 15.2 km (0 to 50,000 ft) • Humidity Operating Non-Operating 20% to 80%RH (non-condensing) 5% to read and write with much higher capacity as follows: • Reads and writes using DDS-1 and DDS-DC formats when using...
hp DDS-2 tape drive user's guide (a1658-90701)
Page 14
...of the DDS-1 and DDS-DC formats. • Reads and writes with much higher capacity when using DDS-1 media (60 m and 90 m). DDS-2 Drive Environmental Requirements The DDS-2 drive has the following environmental requirements: • Ambient Temperature ... 15,000 ft) 0 km to 15.2 km (0 to 50,000 ft) • Humidity Operating Non-Operating 20% to 80%RH (non-condensing) 5% to read and write with much higher capacity as follows: • Reads and writes using DDS-1 ...condensing) Maximum wet bulb temperature = 26_ C 1-4 Introduction DDS-2 Drive The HP C1539A implements the DDS-2 format.
...of the DDS-1 and DDS-DC formats. • Reads and writes with much higher capacity when using DDS-1 media (60 m and 90 m). DDS-2 Drive Environmental Requirements The DDS-2 drive has the following environmental requirements: • Ambient Temperature ... 15,000 ft) 0 km to 15.2 km (0 to 50,000 ft) • Humidity Operating Non-Operating 20% to 80%RH (non-condensing) 5% to read and write with much higher capacity as follows: • Reads and writes using DDS-1 ...condensing) Maximum wet bulb temperature = 26_ C 1-4 Introduction DDS-2 Drive The HP C1539A implements the DDS-2 format.
hp DDS-3 tape drive user's guide (a1658-90702)
Page 13
...Ambient Temperature Operating Non-Operating 5_ C to 40_ C (41_ F to 104_ F) -40_ C to 70_ C (-40_ F to 158_ F) • Humidity Operating Non-Operating 20% to 80%RH (non-condensing) 5% to 95%RH Maximum wet bulb temperature = 26_ C • Vibration Operating (3 axes for drives, 1 axis for autoloaders) Swept Sine Random 0.3 g peak,.../ 350-500 Hz @ -6 dB/octave 36A/53A Random 500 Hz @ 0.000271 g2/Hz (≈0.5 g rms) 5-350 Hz @ 0.0002 g2/Hz HP C1533A/ HP C1537A 350-500 Hz @ -6 dB/octave 500 Hz @ 0.0001 g2/Hz (≈0.3 g rms) Non-Operating Swept Sine Random 0.75 g peak, 5-500 Hz @...
...Ambient Temperature Operating Non-Operating 5_ C to 40_ C (41_ F to 104_ F) -40_ C to 70_ C (-40_ F to 158_ F) • Humidity Operating Non-Operating 20% to 80%RH (non-condensing) 5% to 95%RH Maximum wet bulb temperature = 26_ C • Vibration Operating (3 axes for drives, 1 axis for autoloaders) Swept Sine Random 0.3 g peak,.../ 350-500 Hz @ -6 dB/octave 36A/53A Random 500 Hz @ 0.000271 g2/Hz (≈0.5 g rms) 5-350 Hz @ 0.0002 g2/Hz HP C1533A/ HP C1537A 350-500 Hz @ -6 dB/octave 500 Hz @ 0.0001 g2/Hz (≈0.3 g rms) Non-Operating Swept Sine Random 0.75 g peak, 5-500 Hz @...
hp DDS-DC tape drive user's guide (a1658-90696)
Page 13
...Ambient Temperature Operating Non-Operating 5_ C to 40_ C (41_ F to 104_ F) -40_ C to 70_ C (-40_ F to 158_ F) • Humidity Operating Non-Operating 20% to 80%RH (non-condensing) 5% to 95%RH Maximum wet bulb temperature = 26_ C • Vibration Operating (3 axes for drives, 1 axis for autoloaders) Swept Sine Random 0.3 g peak,.../ 350-500 Hz @ -6 dB/octave 36A/53A Random 500 Hz @ 0.000271 g2/Hz (≈0.5 g rms) 5-350 Hz @ 0.0002 g2/Hz HP C1533A/ HP C1537A 350-500 Hz @ -6 dB/octave 500 Hz @ 0.0001 g2/Hz (≈0.3 g rms) Non-Operating Swept Sine Random 0.75 g peak, 5-500 Hz @...
...Ambient Temperature Operating Non-Operating 5_ C to 40_ C (41_ F to 104_ F) -40_ C to 70_ C (-40_ F to 158_ F) • Humidity Operating Non-Operating 20% to 80%RH (non-condensing) 5% to 95%RH Maximum wet bulb temperature = 26_ C • Vibration Operating (3 axes for drives, 1 axis for autoloaders) Swept Sine Random 0.3 g peak,.../ 350-500 Hz @ -6 dB/octave 36A/53A Random 500 Hz @ 0.000271 g2/Hz (≈0.5 g rms) 5-350 Hz @ 0.0002 g2/Hz HP C1533A/ HP C1537A 350-500 Hz @ -6 dB/octave 500 Hz @ 0.0001 g2/Hz (≈0.3 g rms) Non-Operating Swept Sine Random 0.75 g peak, 5-500 Hz @...
hp 9000 series 700 model 712 technical reference manual (a2615-90602)
Page 10
... interfaces Graphics Internal Mass storage module(s) 70-Watt Power supply Functionality HP-UX 9.03 (or later) PA-RISC PA7100-LC Model 712/60 60 MHz SPECint92 58.1 SPECfp92 79 X11Perf 12K 64 KB Model 712/80 80 MHz 84.3 122.3 17K 256 KB Battery-backed Real-Time...or 1 GB Hard Disk Drives H PC style 3.5-in . Flexible disk drive Low power consumption design Model 712 Technical Reference General Information 1-1 1 General Information Product Overview Features Hewlett-Packard's Model 712 Workstation is based on the monitor selected: H 8-bit Color (with Color Recovery) H 1024 by 768...
... interfaces Graphics Internal Mass storage module(s) 70-Watt Power supply Functionality HP-UX 9.03 (or later) PA-RISC PA7100-LC Model 712/60 60 MHz SPECint92 58.1 SPECfp92 79 X11Perf 12K 64 KB Model 712/80 80 MHz 84.3 122.3 17K 256 KB Battery-backed Real-Time...or 1 GB Hard Disk Drives H PC style 3.5-in . Flexible disk drive Low power consumption design Model 712 Technical Reference General Information 1-1 1 General Information Product Overview Features Hewlett-Packard's Model 712 Workstation is based on the monitor selected: H 8-bit Color (with Color Recovery) H 1024 by 768...
hp 9000 series 700 model 712 technical reference manual (a2615-90602)
Page 36
...Supply cover Led Cable Assy Top Cover Assy Flexible Disk Bezel Filler Bezel HP-Pack Support Bracket Teleshare Board (International) Teleshare Board (domestic) A2878A Graphics HP 9000 Token Ring RS-232 RS-232/LAN RS-232/X.25 2-16 System Board Model 712 Technical Reference No. 10 10 9 9 9 9 19 18 18 ...Exchange Part Number A2263-69510 A2263-69511 A2577-69001 A2578-69001 A2576-69001 A2575-69001 A2084-69002 A2084-69001 A2615-69001 Description CPU, 60 MHz CPU, 80 ...
...Supply cover Led Cable Assy Top Cover Assy Flexible Disk Bezel Filler Bezel HP-Pack Support Bracket Teleshare Board (International) Teleshare Board (domestic) A2878A Graphics HP 9000 Token Ring RS-232 RS-232/LAN RS-232/X.25 2-16 System Board Model 712 Technical Reference No. 10 10 9 9 9 9 19 18 18 ...Exchange Part Number A2263-69510 A2263-69511 A2577-69001 A2578-69001 A2576-69001 A2575-69001 A2084-69002 A2084-69001 A2615-69001 Description CPU, 60 MHz CPU, 80 ...
hp 9000 series 700 model 712 technical reference manual (a2615-90602)
Page 38
... Humidity: Altitude: 5 to 104 deg. F) 80% RH max at 40 deg. C (104 deg. 3 Expansion Slot Cards Card Specifications HP A4011A HP Token Ring/9000 Card Description The HP A4011A HP Token Ring/9000 Card (ITR) is a industry-standard IEEE 802.5. Features H Compatible with card) #AAH Device Driver on DDS tape. Model 712 Technical Reference Expansion Slot Cards 3-1
... Humidity: Altitude: 5 to 104 deg. F) 80% RH max at 40 deg. C (104 deg. 3 Expansion Slot Cards Card Specifications HP A4011A HP Token Ring/9000 Card Description The HP A4011A HP Token Ring/9000 Card (ITR) is a industry-standard IEEE 802.5. Features H Compatible with card) #AAH Device Driver on DDS tape. Model 712 Technical Reference Expansion Slot Cards 3-1
hp 9000 series 700 model 712 technical reference manual (a2615-90602)
Page 40
C (104 deg. F) 3,050 meters (10,000 feet) Power Consumption (Max.) 6.5 Watts Ordering Information The HP A4012A Teleshare Card includes: A2615-90609 Documentation Localization. International versions require external DAA Modules. #AAH Device Driver, AUI, GUI on DDS tape. F) 80% RH max at 40 deg. Model 712 Technical Reference Expansion Slot Cards 3-3 C (41 to 40 deg. Environmental Specifications Temperature: Relative Humidity: Altitude: 5 to 104 deg.
C (104 deg. F) 3,050 meters (10,000 feet) Power Consumption (Max.) 6.5 Watts Ordering Information The HP A4012A Teleshare Card includes: A2615-90609 Documentation Localization. International versions require external DAA Modules. #AAH Device Driver, AUI, GUI on DDS tape. F) 80% RH max at 40 deg. Model 712 Technical Reference Expansion Slot Cards 3-3 C (41 to 40 deg. Environmental Specifications Temperature: Relative Humidity: Altitude: 5 to 104 deg.
hp 9000 series 700 model 712 technical reference manual (a2615-90602)
Page 41
... 3-1. F) 80% RH max at 40 deg. RS-232 Connector Pinouts Pin No. 1 2 3 Signal DCD RXD TXD Pin No. 4 5 6 Ordering Information The HP A4013A Serial Card includes: A2615-90610 Documentation Signal DTR Ground DSR Pin No. 7 8 9 Signal RTS CTS RI 3-4 Expansion Slot Cards Model 712 Technical Reference ... Physical Specifications Length: Height: 193 mm (7.6 in) 64 mm (2.5 in) Environmental Specifications Temperature: Relative Humidity: Altitude: 5 to 104 deg. HP A4013A Serial Card Description The HP A4013A Serial Card adds a second RS-232-C interface to the Model 712 Workstation.
... 3-1. F) 80% RH max at 40 deg. RS-232 Connector Pinouts Pin No. 1 2 3 Signal DCD RXD TXD Pin No. 4 5 6 Ordering Information The HP A4013A Serial Card includes: A2615-90610 Documentation Signal DTR Ground DSR Pin No. 7 8 9 Signal RTS CTS RI 3-4 Expansion Slot Cards Model 712 Technical Reference ... Physical Specifications Length: Height: 193 mm (7.6 in) 64 mm (2.5 in) Environmental Specifications Temperature: Relative Humidity: Altitude: 5 to 104 deg. HP A4013A Serial Card Description The HP A4013A Serial Card adds a second RS-232-C interface to the Model 712 Workstation.
hp 9000 series 700 model 712 technical reference manual (a2615-90602)
Page 44
... cable Recommended Cables: Cables must be ordered from HP's Direct Marketing Division (DMK). HP 24542H 9-pin F/25-pin F serial plotter cable, 3 meter (9.9 ft). Model 712 Technical Reference Expansion Slot Cards 3-7 C (104 deg. C (41 to 40 deg. HP 24542G 9-pin F/25-pin M serial printer/plotter cable 3.0 meter (9.9 ft). F) 80% RH max at 40 deg. For use with...
... cable Recommended Cables: Cables must be ordered from HP's Direct Marketing Division (DMK). HP 24542H 9-pin F/25-pin F serial plotter cable, 3 meter (9.9 ft). Model 712 Technical Reference Expansion Slot Cards 3-7 C (104 deg. C (41 to 40 deg. HP 24542G 9-pin F/25-pin M serial printer/plotter cable 3.0 meter (9.9 ft). F) 80% RH max at 40 deg. For use with...
hp 9000 series 700 model 712 technical reference manual (a2615-90602)
Page 46
...cable 3.0 meter (9.9 ft). For use with the HP 7550B Pen Plotter. HP 24542H 9-pin F/25-pin F serial plotter cable, 3 meter (9.9 ft). F) 3,050 meters (10,000 feet) Power Consumption (Max.) 5.0 Watts Ordering Information The HP A4015A X.25/Serial Card includes: A2615-90610 Documentation A2263... tape Recommended Cables: Cables must be ordered from HP's Direct Marketing Division (DMK). F) 80% RH max at 40 deg. For use with the LaserJets, PaintJets, terminals, and Pen Plotters, except the HP 7550B Pen Plotter. Model 712 Technical Reference Expansion Slot Cards 3-9 C (41 to...
...cable 3.0 meter (9.9 ft). For use with the HP 7550B Pen Plotter. HP 24542H 9-pin F/25-pin F serial plotter cable, 3 meter (9.9 ft). F) 3,050 meters (10,000 feet) Power Consumption (Max.) 5.0 Watts Ordering Information The HP A4015A X.25/Serial Card includes: A2615-90610 Documentation A2263... tape Recommended Cables: Cables must be ordered from HP's Direct Marketing Division (DMK). F) 80% RH max at 40 deg. For use with the LaserJets, PaintJets, terminals, and Pen Plotters, except the HP 7550B Pen Plotter. Model 712 Technical Reference Expansion Slot Cards 3-9 C (41 to...
hp 9000 series 700 model 712 technical reference manual (a2615-90602)
Page 47
... Humidity: Altitude: 5 to 40 deg. to this card is not supported as the boot console. H Support of each channel conforms to the Model 712 workstation. H X Window support. HP A2882A HP D1196A HP A2287A HP A4032A HP A2094A Type 11.8-inch Flat panel 15-inch Color 17-inch Color 17-inch Color 19-inch Color Resolution 1024 by 768... 3-7. F) 80% RH max at 75 Hz. Features H 1024 by 768 by 480 at 40 deg. C (41 to 72 Hz. The analog output of the following VESA timings: 1280 by 1024 at 75 Hz. 1024 by 768 at 75 Hz. 800 by 600 at 75 Hz. 640 by 8 bit color at 60 Hz...
... Humidity: Altitude: 5 to 40 deg. to this card is not supported as the boot console. H Support of each channel conforms to the Model 712 workstation. H X Window support. HP A2882A HP D1196A HP A2287A HP A4032A HP A2094A Type 11.8-inch Flat panel 15-inch Color 17-inch Color 17-inch Color 19-inch Color Resolution 1024 by 768... 3-7. F) 80% RH max at 75 Hz. Features H 1024 by 768 by 480 at 40 deg. C (41 to 72 Hz. The analog output of the following VESA timings: 1280 by 1024 at 75 Hz. 1024 by 768 at 75 Hz. 800 by 600 at 75 Hz. 640 by 8 bit color at 60 Hz...
hp 9000 series 700 model 712 technical reference manual (a2615-90602)
Page 51
Mass Storage 4-3 C (80 deg. F) Shock Operating: Non-operating: 2 G peak, 11 ms, 1/2 sinewave 10 G peak, 11 ms, 1/2 sinewave 20 G peak, 11 ms + 3 ms, 1/2 sinewave 26 ms ...: 0.5 G peak, 5 - 500 Hz 0.0001 G2/Hz, 5 - 500 Hz 0.2 inches pk-pk @ 5 - 30 Hz, 1.0 Gpk @ 30 - 500 Hz 0.015 G2/Hz, 5 - 500 Hz HP A4066A 525 Mbyte Hard Disk Drive Capacity Formatted: 525,000,000 Bytes Performance Seek Times Track to track: 2.6 ms Average: 10 ms Maximum: 25 ms...Rate: Hard Read Error Rate: Seek Error Rate: 10 in 1011 bits read 10 in 1013 bits read 10 in 107 seeks Model 712 Technical Reference Int.
Mass Storage 4-3 C (80 deg. F) Shock Operating: Non-operating: 2 G peak, 11 ms, 1/2 sinewave 10 G peak, 11 ms, 1/2 sinewave 20 G peak, 11 ms + 3 ms, 1/2 sinewave 26 ms ...: 0.5 G peak, 5 - 500 Hz 0.0001 G2/Hz, 5 - 500 Hz 0.2 inches pk-pk @ 5 - 30 Hz, 1.0 Gpk @ 30 - 500 Hz 0.015 G2/Hz, 5 - 500 Hz HP A4066A 525 Mbyte Hard Disk Drive Capacity Formatted: 525,000,000 Bytes Performance Seek Times Track to track: 2.6 ms Average: 10 ms Maximum: 25 ms...Rate: Hard Read Error Rate: Seek Error Rate: 10 in 1011 bits read 10 in 1013 bits read 10 in 107 seeks Model 712 Technical Reference Int.
hp 9000 series 700 model 712 technical reference manual (a2615-90602)
Page 52
...to 50,000 feet) Relative Humidity Operating: Non-operating: Max wetbulb temperature 10% to 90% non-condensing 10% to 158 deg. C (80 deg. F) Shock Operating: Non-operating: 2 G peak, 11 ms, 1/2 sinewave 10 G peak, 11 ms, 1/2 sinewave 20 G peak...5 - 400 Hz 0.2 inches pk-pk @ 5-30 Hz, 1.0 Gpk @ 30-400 Hz 0.015 G2/Hz, 5 - 500 Hz HP A4065A 260 Mbyte Hard Disk Drive Capacity Formatted: 270,000,000 Bytes Performance Seek Times Track to 55 deg. F) 24 deg. Environmental Requirements ...-40 to 131 deg. C (32 to 70 deg. C/hr (75 deg. Mass Storage Model 712 Technical Reference
...to 50,000 feet) Relative Humidity Operating: Non-operating: Max wetbulb temperature 10% to 90% non-condensing 10% to 158 deg. C (80 deg. F) Shock Operating: Non-operating: 2 G peak, 11 ms, 1/2 sinewave 10 G peak, 11 ms, 1/2 sinewave 20 G peak...5 - 400 Hz 0.2 inches pk-pk @ 5-30 Hz, 1.0 Gpk @ 30-400 Hz 0.015 G2/Hz, 5 - 500 Hz HP A4065A 260 Mbyte Hard Disk Drive Capacity Formatted: 270,000,000 Bytes Performance Seek Times Track to 55 deg. F) 24 deg. Environmental Requirements ...-40 to 131 deg. C (32 to 70 deg. C/hr (75 deg. Mass Storage Model 712 Technical Reference