HP ProLiant G6 Technology Overview
Page 2
...use of Thermal Logic technology. By uniting your compute capability and extend the life of each ProLiant G6 server and intelligently manages power to maximize productivity HP infrastructure and management tools can help you save time and money. Maximize energy savings and reduce ...decreases the number of highly efficient power supplies. Using logical servers, HP Insight Dynamics-VSE brings server blades and virtual machines together under a single management paradigm. Reduce operating expenses The HP Insight Control suite and HP Insight Control suite for each ProLiant G6 server and ...
...use of Thermal Logic technology. By uniting your compute capability and extend the life of each ProLiant G6 server and intelligently manages power to maximize productivity HP infrastructure and management tools can help you save time and money. Maximize energy savings and reduce ...decreases the number of highly efficient power supplies. Using logical servers, HP Insight Dynamics-VSE brings server blades and virtual machines together under a single management paradigm. Reduce operating expenses The HP Insight Control suite and HP Insight Control suite for each ProLiant G6 server and ...
ISS Technology Update Index
Page 4
.... Nothing herein should be liable for HP products and services are US registered trademarks of Microsoft Corporation. AMD and AMD Opteron are trademarks of Articles Jump to: A | B | C | D | E | F | G | H | I | K | L | M | N | O | P | Q | R | S | T | U | V | W | Z Article title Page Newsletter issue number T The transition from Megahertz to Gigatransfers 6 Volume 8, Number 4 Three--phase power distribution in HP ProLiant 2 G6 servers Volume 8, Number 7 W When to use Brocade SAN switches...
.... Nothing herein should be liable for HP products and services are US registered trademarks of Microsoft Corporation. AMD and AMD Opteron are trademarks of Articles Jump to: A | B | C | D | E | F | G | H | I | K | L | M | N | O | P | Q | R | S | T | U | V | W | Z Article title Page Newsletter issue number T The transition from Megahertz to Gigatransfers 6 Volume 8, Number 4 Three--phase power distribution in HP ProLiant 2 G6 servers Volume 8, Number 7 W When to use Brocade SAN switches...
ISS Technology Update Volume 8, Number 5
Page 5
...8213;Support and Documents‖ and enter the product name/number. ISS Technology Update Volume 8, Number 5 Accelerated iSCSI application examples Administrators can be downloaded from SAN'). HP Accelerated iSCSI Softpaq Description HP ProLiant Networking Software Current Softpaq sp43831.exe All firmware upgrades..., the DL385 G5p, DL385 G6, DL360 G6, and DL380 G6 ProLiant servers are required to download Softpaqs for all compatible multifunction server adapters. open -iscsi-2.0.7070.44e.src.rpm Should users want to download HP Accelerated iSCSI drivers for iSCSI ...
...8213;Support and Documents‖ and enter the product name/number. ISS Technology Update Volume 8, Number 5 Accelerated iSCSI application examples Administrators can be downloaded from SAN'). HP Accelerated iSCSI Softpaq Description HP ProLiant Networking Software Current Softpaq sp43831.exe All firmware upgrades..., the DL385 G5p, DL385 G6, DL360 G6, and DL380 G6 ProLiant servers are required to download Softpaqs for all compatible multifunction server adapters. open -iscsi-2.0.7070.44e.src.rpm Should users want to download HP Accelerated iSCSI drivers for iSCSI ...
ISS Technology Update Volume 8, Number 5
Page 7
...on the topics discussed in the HP ProLiant G6 servers prepares the way for these resources: Resource URL HP StorageWorks Modular Smart Arrays HP ProLiant Smart Array RAID controllers http://h18006.www1.hp.com/storage/disk_storage/msa_diskarrays/ index.html http://h18004.www1.hp.com/products/servers/proliantstorage/array controllers/index..... As a result, 6-Gb/s drives do not incur any performance penalty when mixed with 6-Gb/s SAS channels in this number of SAS drives. With 3-Gb/s drives and SAS channels, the four channel SAS port will provide definite performance benefits when used...
...on the topics discussed in the HP ProLiant G6 servers prepares the way for these resources: Resource URL HP StorageWorks Modular Smart Arrays HP ProLiant Smart Array RAID controllers http://h18006.www1.hp.com/storage/disk_storage/msa_diskarrays/ index.html http://h18004.www1.hp.com/products/servers/proliantstorage/array controllers/index..... As a result, 6-Gb/s drives do not incur any performance penalty when mixed with 6-Gb/s SAS channels in this number of SAS drives. With 3-Gb/s drives and SAS channels, the four channel SAS port will provide definite performance benefits when used...
ISS Technology Update Volume 8, Number 7
Page 6
..., a fully functional vSphere host can simply be pulled from SAN deployments are also possible. ISS Technology Update Volume 8, Number 7 Shared storage A third alternative would be to install the ESXi installable image on shared storage, which could be used to...range of this article, visit: Resource Virtualization technology communications HP ProLiant BL490c G6 Server series HP ProLiant BL495c G6 Server series URL http://h18004.www1.hp.com/products/servers/technology /whitepapers/virtualization/index.html http://h10010.www1.hp.com/wwpc/us/en/sm/WF25a/3 709945-3709945-3328410-...
..., a fully functional vSphere host can simply be pulled from SAN deployments are also possible. ISS Technology Update Volume 8, Number 7 Shared storage A third alternative would be to install the ESXi installable image on shared storage, which could be used to...range of this article, visit: Resource Virtualization technology communications HP ProLiant BL490c G6 Server series HP ProLiant BL495c G6 Server series URL http://h18004.www1.hp.com/products/servers/technology /whitepapers/virtualization/index.html http://h10010.www1.hp.com/wwpc/us/en/sm/WF25a/3 709945-3709945-3328410-...
ISS Technology Update, Volume 8, Number 3
Page 7
... Number 3 Meet the Expert-Wayne Vuong Wayne Vuong has been an Engineering Program Manager with performance through the Common Design effort. Wayne says that is phenomenal. Also, various hurdles kept appearing that it into Onboard Administrator reduce server power consumption by ProLiant G6 servers... (TAC), a professional social network that affected product decisions." As these design activities were finished, they can result in fifth-generation (G5) and G6 ProLiant servers, and led the Common Design team for Wayne because even at HP. He and his support of his manager, ...
... Number 3 Meet the Expert-Wayne Vuong Wayne Vuong has been an Engineering Program Manager with performance through the Common Design effort. Wayne says that is phenomenal. Also, various hurdles kept appearing that it into Onboard Administrator reduce server power consumption by ProLiant G6 servers... (TAC), a professional social network that affected product decisions." As these design activities were finished, they can result in fifth-generation (G5) and G6 ProLiant servers, and led the Common Design team for Wayne because even at HP. He and his support of his manager, ...
ISS Technology Update, Volume 8, Number 4
Page 5
...: an overview of system memory technologies, 8th Edition DDR3 Configuration Recommendations for HP ProLiant G6 Servers URL http://h20000.www2.hp.com/bc/docs/support/SupportManual/c 00256987/c00256987.pdf ftp://ftp.hp.com/pub/c-products/servers/options/Memory-ConfigRecommendations-for servers with memory capacity of 24 GB or ...frequency. Customers should consider using dual-rank 2-gigabyte DIMMs. UDIMMs are top priorities. ISS Technology Update Volume 8, Number 4 Unbuffered DDR-3 DIMMs are producing two types of DDR-3 SDRAM DIMMs: Registered DIMMs (RDIMMs) and Unbuffered DIMMs (UDIMMs).
...: an overview of system memory technologies, 8th Edition DDR3 Configuration Recommendations for HP ProLiant G6 Servers URL http://h20000.www2.hp.com/bc/docs/support/SupportManual/c 00256987/c00256987.pdf ftp://ftp.hp.com/pub/c-products/servers/options/Memory-ConfigRecommendations-for servers with memory capacity of 24 GB or ...frequency. Customers should consider using dual-rank 2-gigabyte DIMMs. UDIMMs are top priorities. ISS Technology Update Volume 8, Number 4 Unbuffered DDR-3 DIMMs are producing two types of DDR-3 SDRAM DIMMs: Registered DIMMs (RDIMMs) and Unbuffered DIMMs (UDIMMs).