Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Page 9
The data contains the error code. Specific error information is contained in CPQTHRSH.MIB Symptom: Rising Threshold passed. An alarm entry has crossed its rising threshold. SNMP Trap: cpqMeRisingAlarmExtended - 10005 in the ...
The data contains the error code. Specific error information is contained in CPQTHRSH.MIB Symptom: Rising Threshold passed. An alarm entry has crossed its rising threshold. SNMP Trap: cpqMeRisingAlarmExtended - 10005 in the ...
ProLiant Essentials Foundation Pack Installation Guide
Page 1
...asset, and configuration management for Arrays) or the Adaptec RAID Configuration Utility as constituting an additional warranty. HP ProLiant Essentials Foundation Pack Installation Guide © Copyright 2002, 2008 Hewlett-Packard Development Company, L.P. Configure the...HP SIM and Version Control to automatically download the latest versions of -date software, and deploy updates to -Date Download the latest SmartStart CD and ProLiant Firmware Maintenance CD from www.hp.com/go /subscriberschoice After installing the OS, insert the SmartStart CD and install the operating system-specific...
...asset, and configuration management for Arrays) or the Adaptec RAID Configuration Utility as constituting an additional warranty. HP ProLiant Essentials Foundation Pack Installation Guide © Copyright 2002, 2008 Hewlett-Packard Development Company, L.P. Configure the...HP SIM and Version Control to automatically download the latest versions of -date software, and deploy updates to -Date Download the latest SmartStart CD and ProLiant Firmware Maintenance CD from www.hp.com/go /subscriberschoice After installing the OS, insert the SmartStart CD and install the operating system-specific...
HP BladeSystem Management Pack version 1.0 for Microsoft System Center Essentials Troubleshooting Assistant
Page 8
... Alert Descriptions in an external management pack. Operational and usage issues The following sections provide troubleshooting information for operational issues with the HP BladeSystem Management Packs for System Center Essentials: • Monitor Manager is unable to connect to the monitor service (on page 9)...Manager for the monitor service (on page 9) • A critical state displays in the Monitor Manager for custom information management specific to HP Management Packs is stored in the Alert Properties view are truncated (on page 12) • The Enclosure Diagram view shows folders...
... Alert Descriptions in an external management pack. Operational and usage issues The following sections provide troubleshooting information for operational issues with the HP BladeSystem Management Packs for System Center Essentials: • Monitor Manager is unable to connect to the monitor service (on page 9)...Manager for the monitor service (on page 9) • A critical state displays in the Monitor Manager for custom information management specific to HP Management Packs is stored in the Alert Properties view are truncated (on page 12) • The Enclosure Diagram view shows folders...
HP BladeSystem Management Pack version 1.0 for Microsoft System Center Essentials Troubleshooting Assistant
Page 12
When one of these icons appears gray instead of the HP BladeSystem Management Pack for a specific health collection. However, if two SNMP trap events of the HP BladeSystem Management Pack are designed to consolidate similar events and to not repeat issues. Active alert view displays only one alert ... two SNMP trap events have been generated, only one alert is displayed by initials System Center Essentials groups the health components of the HP BladeSystem Management Pack into sub-folders, and only displays the initial letters of an empty bay slot's fan or power supply will not...
When one of these icons appears gray instead of the HP BladeSystem Management Pack for a specific health collection. However, if two SNMP trap events of the HP BladeSystem Management Pack are designed to consolidate similar events and to not repeat issues. Active alert view displays only one alert ... two SNMP trap events have been generated, only one alert is displayed by initials System Center Essentials groups the health components of the HP BladeSystem Management Pack into sub-folders, and only displays the initial letters of an empty bay slot's fan or power supply will not...
Error Prevention Guide
Page 9
... Power Requirements Be sure that option. To obtain the most accurate power capacity and assessment of power margin, use the power calculator provided on the specific power capabilities of power fluctuations and disruptions and is a requirement, if applicable to the server. Power management hardware like an uninterruptible power supply (UPS) minimizes...
... Power Requirements Be sure that option. To obtain the most accurate power capacity and assessment of power margin, use the power calculator provided on the specific power capabilities of power fluctuations and disruptions and is a requirement, if applicable to the server. Power management hardware like an uninterruptible power supply (UPS) minimizes...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 6
...hardware lifecycle management and remote administration of Microsoft® Windows®, Microsoft® System Center Essentials, and the HP BladeSystem c-Class Onboard Administrator. Predefined event processing rules build on the functionality of the c-Class enclosures, predefined views,... including real-time and prefailure event definitions. Features The HP BladeSystem Management Pack for HP BladeSystem cClass enclosures. Designed specifically for Microsoft® System Center Essentials 2007 User Guide. HP assumes that complements and extends System Center Essentials, integrates ...
...hardware lifecycle management and remote administration of Microsoft® Windows®, Microsoft® System Center Essentials, and the HP BladeSystem c-Class Onboard Administrator. Predefined event processing rules build on the functionality of the c-Class enclosures, predefined views,... including real-time and prefailure event definitions. Features The HP BladeSystem Management Pack for HP BladeSystem cClass enclosures. Designed specifically for Microsoft® System Center Essentials 2007 User Guide. HP assumes that complements and extends System Center Essentials, integrates ...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 34
...Error Warning Onboard Administrator Degraded. Interconnect Failed. Tasks The HP BladeSystem Management Pack for Microsoft® System Center Essentials 2007 includes predefined tasks that can be monitored and generated Alerts with specific classes. Health check degraded. data. 26 Error Monitor ...Service Failed to Stop a monitoring. Not all tasks appear in -depth HP BladeSystem information, carry out advanced remote server administration, and...
...Error Warning Onboard Administrator Degraded. Interconnect Failed. Tasks The HP BladeSystem Management Pack for Microsoft® System Center Essentials 2007 includes predefined tasks that can be monitored and generated Alerts with specific classes. Health check degraded. data. 26 Error Monitor ...Service Failed to Stop a monitoring. Not all tasks appear in -depth HP BladeSystem information, carry out advanced remote server administration, and...
10 Gigabit Ethernet technology for industry-standard servers
Page 4
... well-established of full-duplex, switched Ethernet with collision detection (CSMA/CD) software protocols, these measures increased transmission latency in enterprise storage. The InfiniBand architecture specification defines a connection between processor nodes and high performance I/O nodes such as Priority based Flow Control and Congestion Notification allows Ethernet to http://www.ieee802.org...
... well-established of full-duplex, switched Ethernet with collision detection (CSMA/CD) software protocols, these measures increased transmission latency in enterprise storage. The InfiniBand architecture specification defines a connection between processor nodes and high performance I/O nodes such as Priority based Flow Control and Congestion Notification allows Ethernet to http://www.ieee802.org...
10 Gigabit Ethernet technology for industry-standard servers
Page 5
... the remainder of the packet to be forwarded to the destination port after checking the integrity. HP supported 10GbE media standards All HP supported media specifications for 10GbE The 10GbE standard specifies various physical medium dependent (PMD) connections to last bit received...standard and their distinguishing attributes, summarizes the options supported, and indicates distances achieved, depending on Cat6A, 7 backplane backplane copper copper Media Specification FDDI, OM1, OM2, OM3 Single-mode fiber (SMF), 10um Multi-mode fiber (MMF), 50-62um 4-Lane Backplane 1-Lane Backplane ...
... the remainder of the packet to be forwarded to the destination port after checking the integrity. HP supported 10GbE media standards All HP supported media specifications for 10GbE The 10GbE standard specifies various physical medium dependent (PMD) connections to last bit received...standard and their distinguishing attributes, summarizes the options supported, and indicates distances achieved, depending on Cat6A, 7 backplane backplane copper copper Media Specification FDDI, OM1, OM2, OM3 Single-mode fiber (SMF), 10um Multi-mode fiber (MMF), 50-62um 4-Lane Backplane 1-Lane Backplane ...
10 Gigabit Ethernet technology for industry-standard servers
Page 9
... serve adapter and the NC524SFP Dual Port 10GbE Module are optimized for connecting to specific information about ProLiant, BladeSystem, and HP ProCurve 10GbE products. Figure 4. In addition, HP Virtual Connect is using 10GbE technology and Flex-10 to fulfill needs of their server...of 10GbE and will reduce the cost of 10GbE products for ProLiant blade, rack, and tower platforms. HP 10GbE architecture includes network designs that benefit from 10GbE bandwidth. These designs incorporate appropriate media specifications for TCP checksum and segmentation (LSO) offload capability, VLAN...
... serve adapter and the NC524SFP Dual Port 10GbE Module are optimized for connecting to specific information about ProLiant, BladeSystem, and HP ProCurve 10GbE products. Figure 4. In addition, HP Virtual Connect is using 10GbE technology and Flex-10 to fulfill needs of their server...of 10GbE and will reduce the cost of 10GbE products for ProLiant blade, rack, and tower platforms. HP 10GbE architecture includes network designs that benefit from 10GbE bandwidth. These designs incorporate appropriate media specifications for TCP checksum and segmentation (LSO) offload capability, VLAN...
10 Gigabit Ethernet technology for industry-standard servers
Page 13
...serve the expanding 10GbE market. which includes intelligent, multifunction network adapters, mezzanine cards, Virtual Connect interconnect modules and network switches - HP is introducing intelligent, dynamic technologies like Flex10 for a converged network fabric. Packets that tag gets stripped off at the destination....so that performance and security are unaffected. The adoption of 10GbE comes in a side by implementing the 10GBASE-KR (IEEE specification 802.3ap) one-lane, serial backplane connection standard. Flex-10 allows the traffic of four FlexNICs to share the same high...
...serve the expanding 10GbE market. which includes intelligent, multifunction network adapters, mezzanine cards, Virtual Connect interconnect modules and network switches - HP is introducing intelligent, dynamic technologies like Flex10 for a converged network fabric. Packets that tag gets stripped off at the destination....so that performance and security are unaffected. The adoption of 10GbE comes in a side by implementing the 10GBASE-KR (IEEE specification 802.3ap) one-lane, serial backplane connection standard. Flex-10 allows the traffic of four FlexNICs to share the same high...
Booting HP ProLiant servers from a storage area network
Page 4
...ID. This job will create the file .\lib\hwconfig\hba\ID.ini where ID is installed. 2. Ensure that boots from an HP StorageWorks Storage Area Network (SAN). Hardware Configuration\HBA job folder on Fibre Channel switches" section for important details about SAN configurations and...are supported for the target server to 0 like a new server) SelectBootEnable=0(this should be set to execute the Read ProLiant ML/DL/BL QLogic HBA Configuration [server specific] job from SAN. For example, the generated file might look like this: [HBA0] WWID=500508b200713e72 HostAdapterBiosEnable=0 (this ...
...ID. This job will create the file .\lib\hwconfig\hba\ID.ini where ID is installed. 2. Ensure that boots from an HP StorageWorks Storage Area Network (SAN). Hardware Configuration\HBA job folder on Fibre Channel switches" section for important details about SAN configurations and...are supported for the target server to 0 like a new server) SelectBootEnable=0(this should be set to execute the Read ProLiant ML/DL/BL QLogic HBA Configuration [server specific] job from SAN. For example, the generated file might look like this: [HBA0] WWID=500508b200713e72 HostAdapterBiosEnable=0 (this ...
Booting HP ProLiant servers from a storage area network
Page 5
Create a LUN for the ID field. Execute the Deploy ProLiant BL System Configuration (Boot From SAN) job from the Server Deployment Toolbox\1 - This job disables the embedded array controller and put the HBA controller first ... file created in the link description as the first visible LUN. For Linux Edition, click on the target server. Execute the Write ProLiant ML/DL/BL QLogic HBA Configuration [server specific] job from the Server Deployment Toolbox\1 - Hardware Configuration\System job folder on New Computers or All Computers. Configure the target server...
Create a LUN for the ID field. Execute the Deploy ProLiant BL System Configuration (Boot From SAN) job from the Server Deployment Toolbox\1 - This job disables the embedded array controller and put the HBA controller first ... file created in the link description as the first visible LUN. For Linux Edition, click on the target server. Execute the Write ProLiant ML/DL/BL QLogic HBA Configuration [server specific] job from the Server Deployment Toolbox\1 - Hardware Configuration\System job folder on New Computers or All Computers. Configure the target server...
Drive technology overview
Page 6
... is in high vibration environments. Supplier production qualification 4. The team monitors the performance of four specific steps: 1. Continuous improvement/performance monitoring HP development engineers work I/O workloads. The final stage of the supplier production qualification includes a comprehensive ...production phase of approximately 50 different procedures and specifications that determine the testing and metrics that pass the extensive HP qualification process proceed into HP server and storage systems. The HP processes also ensure continuous improvement in a single...
... is in high vibration environments. Supplier production qualification 4. The team monitors the performance of four specific steps: 1. Continuous improvement/performance monitoring HP development engineers work I/O workloads. The final stage of the supplier production qualification includes a comprehensive ...production phase of approximately 50 different procedures and specifications that determine the testing and metrics that pass the extensive HP qualification process proceed into HP server and storage systems. The HP processes also ensure continuous improvement in a single...
Drive technology overview
Page 8
... or 600 MB/s, in each direction. The SATA specification was targeted at 6 Gb/s, giving it an effective maximum theoretical bandwidth of SAS, see the technology brief entitled "Serial ATA technology" at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00301688/c00301688.pdf Interconnect bandwidths...The implications of about 175 MB/s, or less than one drive per controller port. For a more detailed discussion of 600 MB/s. HP was introduced with HP ProLiant G6 servers in 2009. however, the 6 Gb/s link speed is based on a disk controller. This is only achieved using new SAS...
... or 600 MB/s, in each direction. The SATA specification was targeted at 6 Gb/s, giving it an effective maximum theoretical bandwidth of SAS, see the technology brief entitled "Serial ATA technology" at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00301688/c00301688.pdf Interconnect bandwidths...The implications of about 175 MB/s, or less than one drive per controller port. For a more detailed discussion of 600 MB/s. HP was introduced with HP ProLiant G6 servers in 2009. however, the 6 Gb/s link speed is based on a disk controller. This is only achieved using new SAS...
Fully-Buffered DIMM technology in HP ProLiant servers
Page 3
The electrical load accumulates as data rates increase to DDR2 800. Figure 2. HP works with JEDEC memory vendors and chipset developers during memory technology development to ensure that new memory products fulfill customer needs in ... number of the Electronic Industries Alliance. For future generations of loads supported per channel based on the bus. Consequently, JEDEC3 developed the Fully-Buffered DIMM specification, a serial interface that negatively affects signal integrity. For example, Figure 2 shows the number of high-performance servers, neither option was not a viable ...
The electrical load accumulates as data rates increase to DDR2 800. Figure 2. HP works with JEDEC memory vendors and chipset developers during memory technology development to ensure that new memory products fulfill customer needs in ... number of the Electronic Industries Alliance. For future generations of loads supported per channel based on the bus. Consequently, JEDEC3 developed the Fully-Buffered DIMM specification, a serial interface that negatively affects signal integrity. For example, Figure 2 shows the number of high-performance servers, neither option was not a viable ...
Fully-Buffered DIMM technology in HP ProLiant servers
Page 9
...subsystem architecture using cost optimized, industry-standard DRAM components. For example, the FB-DIMM in slot 1A must be mixed in a specific server, single-rank and dual-rank FB-DIMMs should be the same type (size and rank) as significant. and dual-rank FBDIMMs ...single-rank DIMMs if possible. FBDIMM technology also delivers improved reliability through memory interleaving. Performance tuning, achieving maximum performance HP ProLiant servers implement a multi-branch memory architecture to offer customers products with the most reliable, best performing memory at the lowest possible cost...
...subsystem architecture using cost optimized, industry-standard DRAM components. For example, the FB-DIMM in slot 1A must be mixed in a specific server, single-rank and dual-rank FB-DIMMs should be the same type (size and rank) as significant. and dual-rank FBDIMMs ...single-rank DIMMs if possible. FBDIMM technology also delivers improved reliability through memory interleaving. Performance tuning, achieving maximum performance HP ProLiant servers implement a multi-branch memory architecture to offer customers products with the most reliable, best performing memory at the lowest possible cost...
HP Insight Diagnostics Online Edition Featuring Survey Utility and IML Viewer
Page 1
... Standard Servers June 2004 Technical White Paper HP Insight Diagnostics Online Edition Featuring Survey Utility and IML Viewer Table of Contents Abstract Executive Summary 3 Introduction 3 Importance of Service Tools 5 What is the Insight ... from System Management Homepage 10 Accessing from Systems Insight Manager 10 Logging In 10 Creating Reports 11 Transferring and Printing Survey Files 11 Conclusion 11 Specifications 12 This paper provides an overview of the technology, features, and use of Insight Diagnostics Online Edition.
... Standard Servers June 2004 Technical White Paper HP Insight Diagnostics Online Edition Featuring Survey Utility and IML Viewer Table of Contents Abstract Executive Summary 3 Introduction 3 Importance of Service Tools 5 What is the Insight ... from System Management Homepage 10 Accessing from Systems Insight Manager 10 Logging In 10 Creating Reports 11 Transferring and Printing Survey Files 11 Conclusion 11 Specifications 12 This paper provides an overview of the technology, features, and use of Insight Diagnostics Online Edition.
HP Insight Diagnostics Online Edition Featuring Survey Utility and IML Viewer
Page 3
... selected entries as repaired • Clear the IML of all entries which will delete the log from nonvolatile memory (NVRAM) This combination of times this specific event has occurred, the time and date the event was last updated, and the initial time and date the event occurred, filtered by a server.
... selected entries as repaired • Clear the IML of all entries which will delete the log from nonvolatile memory (NVRAM) This combination of times this specific event has occurred, the time and date the event was last updated, and the initial time and date the event occurred, filtered by a server.
HP Insight Diagnostics Online Edition Featuring Survey Utility and IML Viewer
Page 4
... meeting this objective. The primary requirements for in-depth troubleshooting during a service call. • Automating configuration history and audit trail reporting to address these challenges, specific requirements have emerged in : • Faster problem resolution times • Minimized administration costs and resources • Higher server availability The Insight Diagnostics Online Edition was...
... meeting this objective. The primary requirements for in-depth troubleshooting during a service call. • Automating configuration history and audit trail reporting to address these challenges, specific requirements have emerged in : • Faster problem resolution times • Minimized administration costs and resources • Higher server availability The Insight Diagnostics Online Edition was...