HP Power Capping and Dynamic Power Capping for ProLiant servers technology brief, 1st edition
Page 8
...individual power cap. ProLiant G5 servers ML350, ML370, DL360, DL365, DL380, and DL385 All c-Class BladeSystem servers Basic Power Capping also requires the following system firmware: System BIOS 2008.11.01 or later iLO 2 version 1.70 or later Onboard Administrator firmware version 2.32 or later (for HP ...in the group is 725 watts. Each of these numbers is 60 percent of the wattage between the minimum power and the power supply rating of the individual power caps equals the group cap. supported because Dynamic Power Capping can be selected within IPM, including Insight collections...
...individual power cap. ProLiant G5 servers ML350, ML370, DL360, DL365, DL380, and DL385 All c-Class BladeSystem servers Basic Power Capping also requires the following system firmware: System BIOS 2008.11.01 or later iLO 2 version 1.70 or later Onboard Administrator firmware version 2.32 or later (for HP ...in the group is 725 watts. Each of these numbers is 60 percent of the wattage between the minimum power and the power supply rating of the individual power caps equals the group cap. supported because Dynamic Power Capping can be selected within IPM, including Insight collections...
HP Power Capping and Dynamic Power Capping for ProLiant servers technology brief, 1st edition
Page 21
...in Table 6, capping to average with basic Power Capping almost doubles the number of servers that may cause an increase in latency during workload peaks. Provisioning the power to the total of the HP 2250W power supplies' specification requires delivering 7836 watts to the ...watts. Using Enclosure Dynamic Power Capping, an administrator can essentially cap the electrical provisioning required for 8 ProLiant DL580 G5 servers (based on HP Power Calculator) 3384 watts Maximum power consumption when capping to average 1900 watts Savings in power capacity 1484 watts Additional ...
...in Table 6, capping to average with basic Power Capping almost doubles the number of servers that may cause an increase in latency during workload peaks. Provisioning the power to the total of the HP 2250W power supplies' specification requires delivering 7836 watts to the ...watts. Using Enclosure Dynamic Power Capping, an administrator can essentially cap the electrical provisioning required for 8 ProLiant DL580 G5 servers (based on HP Power Calculator) 3384 watts Maximum power consumption when capping to average 1900 watts Savings in power capacity 1484 watts Additional ...
ISS Technology Update Index
Page 3
... servers gracefully with the HP ProLiant ML360 5 uninterruptible power supply solution Soft memory errors caused by natural phenomena 4 Spotlight: HP Microsoft Solutions Lab benefits customers, 5 partners, and resellers Volume 9, Number 1 Volume 9, Number 1 Volume 7, Number 9 January 2010 January 2010 October 2008 Volume 7, Number 10 December 2008 Volume 7, Number 6 June 2008 Volume 7, Number 6 June 2008 Volume 7, Number 6 June 2008 Volume 7, Number 7 Volume 7, Number 7 August 2008 August...
... servers gracefully with the HP ProLiant ML360 5 uninterruptible power supply solution Soft memory errors caused by natural phenomena 4 Spotlight: HP Microsoft Solutions Lab benefits customers, 5 partners, and resellers Volume 9, Number 1 Volume 9, Number 1 Volume 7, Number 9 January 2010 January 2010 October 2008 Volume 7, Number 10 December 2008 Volume 7, Number 6 June 2008 Volume 7, Number 6 June 2008 Volume 7, Number 6 June 2008 Volume 7, Number 7 Volume 7, Number 7 August 2008 August...
ISS Technology Update, Volume 8, Number 3
Page 7
...facilitates interaction between HP customers and ISS technologists. In fact, Wayne says that has been implemented in fifth-generation (G5) and G6 ProLiant servers, and led the Common Design team for G5 and midway into G6. ISS Technology Update Volume 8, Number 3 Meet the... such as fans, power supplies, and unpopulated I/O and memory slots. 7 Nevertheless, Wayne kept implementing workarounds to dynamically balance power efficiency with the same proven design virtually eliminates design errors that it into Onboard Administrator reduce server power consumption by their design...
...facilitates interaction between HP customers and ISS technologists. In fact, Wayne says that has been implemented in fifth-generation (G5) and G6 ProLiant servers, and led the Common Design team for G5 and midway into G6. ISS Technology Update Volume 8, Number 3 Meet the... such as fans, power supplies, and unpopulated I/O and memory slots. 7 Nevertheless, Wayne kept implementing workarounds to dynamically balance power efficiency with the same proven design virtually eliminates design errors that it into Onboard Administrator reduce server power consumption by their design...
ISS Technology Update, Volume 9 Number 1
Page 1
.../SupportManual/c019488 92/c01948892.pdf HP Power Supply Technology http://techcomm.cca.hp.com/whitepapers/2009/TC091110TB.pdf HP ProLiant 100-series Intel-based G6 server technology, 3rd edition http://techcomm.cca.hp.com/WhitePapers/2009/TC091203TB.pdf HP Smart Array Controller technology, 3rd edition http://techcomm.cca.hp.com/WhitePapers/2009/TC091204TB.pdf Using HP ProLiant Network Teaming Software with Microsoft...
.../SupportManual/c019488 92/c01948892.pdf HP Power Supply Technology http://techcomm.cca.hp.com/whitepapers/2009/TC091110TB.pdf HP ProLiant 100-series Intel-based G6 server technology, 3rd edition http://techcomm.cca.hp.com/WhitePapers/2009/TC091203TB.pdf HP Smart Array Controller technology, 3rd edition http://techcomm.cca.hp.com/WhitePapers/2009/TC091204TB.pdf Using HP ProLiant Network Teaming Software with Microsoft...