HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 24
..., record all boards, memory modules, fans, PCI and IPMI option cards, and non-hot-pluggable hard drives. Refer to illustrate procedural steps are properly grounded (earthed) before removal or installation. Non-hot-plug devices... Non-hot-pluggable devices require that all components operate properly. Removal and replacement procedures 24 Required tools You need the following tools to perform these figures are used in the server include the processor, all pertinent component information, including model and serial number, for the HP ProLiant ML150 G6...
..., record all boards, memory modules, fans, PCI and IPMI option cards, and non-hot-pluggable hard drives. Refer to illustrate procedural steps are properly grounded (earthed) before removal or installation. Non-hot-plug devices... Non-hot-pluggable devices require that all components operate properly. Removal and replacement procedures 24 Required tools You need the following tools to perform these figures are used in the server include the processor, all pertinent component information, including model and serial number, for the HP ProLiant ML150 G6...
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 42
...installed in processor socket 1. With two processors installed, the server supports boot functions through the processor installed in processor socket 2 and provides a processor failure message. The two LGA1366 processor sockets support the following sections for instructions on removing or replacing the processor, the memory...prevent possible server malfunction in 2P systems, ensure that both processors are the same type (series). Processor The HP ProLiant ML150 G6 Server supports single (1P)- Figure 3-18 LGA1366 processor sockets Item Description 1 Processor 1 socket 2 Processor ...
...installed in processor socket 1. With two processors installed, the server supports boot functions through the processor installed in processor socket 2 and provides a processor failure message. The two LGA1366 processor sockets support the following sections for instructions on removing or replacing the processor, the memory...prevent possible server malfunction in 2P systems, ensure that both processors are the same type (series). Processor The HP ProLiant ML150 G6 Server supports single (1P)- Figure 3-18 LGA1366 processor sockets Item Description 1 Processor 1 socket 2 Processor ...
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 47
... 12 CPU2_DIMM slot 1D Guidelines for installing memory modules Use the following guidelines when adding or replacing memory modules: • Use registered and un-buffered DDR3 ECC DIMM. • Supported DIMM capacities: 1GB, 2GB, 4GB DDR3 registered DIMM and 1GB, 2GB un- Removal and replacement procedures 47 Memory The HP ProLiant ML150 G6 server provides 12 DIMM slots...
... 12 CPU2_DIMM slot 1D Guidelines for installing memory modules Use the following guidelines when adding or replacing memory modules: • Use registered and un-buffered DDR3 ECC DIMM. • Supported DIMM capacities: 1GB, 2GB, 4GB DDR3 registered DIMM and 1GB, 2GB un- Removal and replacement procedures 47 Memory The HP ProLiant ML150 G6 server provides 12 DIMM slots...
HP ProLiant ML100 Series Server User Guide
Page 3
... G6 servers 23 Memory options (ML150 G6 servers) ...24 Memory subsystem architecture ...24 Single-, dual-, and quad-rank DIMMs 24 DIMM identification...25 Memory configurations ...25 General DIMM slot population guidelines 26 Installing DIMMs ...28 Expansion board options ...29 Installing a storage controller...32 Battery-backed write cache battery pack option 32 Installing the FBWC module and capacitor pack 35 HP...
... G6 servers 23 Memory options (ML150 G6 servers) ...24 Memory subsystem architecture ...24 Single-, dual-, and quad-rank DIMMs 24 DIMM identification...25 Memory configurations ...25 General DIMM slot population guidelines 26 Installing DIMMs ...28 Expansion board options ...29 Installing a storage controller...32 Battery-backed write cache battery pack option 32 Installing the FBWC module and capacitor pack 35 HP...
HP ProLiant ML100 Series Server User Guide
Page 21
... as shown in this section, the term "DIMM" is seated securely. 10. Memory subsystem architecture (ML110 G6 servers) The memory subsystem in the following DIMM speeds: • Single- All memory installed in this server supports UDIMMs. In this server is divided into the bay until ...it is used. Hardware options installation 21 Slide the media drive fully into channels. ...
... as shown in this section, the term "DIMM" is seated securely. 10. Memory subsystem architecture (ML110 G6 servers) The memory subsystem in the following DIMM speeds: • Single- All memory installed in this server supports UDIMMs. In this server is divided into the bay until ...it is used. Hardware options installation 21 Slide the media drive fully into channels. ...
HP ProLiant ML100 Series Server User Guide
Page 22
... architecture also enables the Mirrored Memory and Lockstep memory modes. and dual-rank DIMMs (ML110 G6 servers) To understand and configure memory protection modes properly, an understanding of memory chips that is similar to or reading from the memory. A quad-rank DIMM is... configuration requirements are reported by letter. DIMM identification (ML110 G6 servers) IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to populate for error reporting. DIMM slots in Advanced ECC mode. Hardware options installation 22 Channel Slot 1 C A 2 D B Slot number...
... architecture also enables the Mirrored Memory and Lockstep memory modes. and dual-rank DIMMs (ML110 G6 servers) To understand and configure memory protection modes properly, an understanding of memory chips that is similar to or reading from the memory. A quad-rank DIMM is... configuration requirements are reported by letter. DIMM identification (ML110 G6 servers) IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to populate for error reporting. DIMM slots in Advanced ECC mode. Hardware options installation 22 Channel Slot 1 C A 2 D B Slot number...
HP ProLiant ML100 Series Server User Guide
Page 23
...maximum of 8 GB using 2-GB dual-rank UDIMMs. General DIMM slot population guidelines (ML110 G6 servers) Observe the following illustration and table. Hardware options installation 23 Item Description 1 Size 2 Rank 3 Data width 4 Memory speed 5 DIMM type Definition - 1R = Single-rank 2R = Dual-rank 4R = Quad...installed. • Do not mix Unbuffered and Registered PC3 DIMMs. • Each channel supports up to two Unbuffered DIMMs. • Single DIMM (non-interleaving) must be populated with ECC) For the latest supported memory information, see the QuickSpecs on the HP...
...maximum of 8 GB using 2-GB dual-rank UDIMMs. General DIMM slot population guidelines (ML110 G6 servers) Observe the following illustration and table. Hardware options installation 23 Item Description 1 Size 2 Rank 3 Data width 4 Memory speed 5 DIMM type Definition - 1R = Single-rank 2R = Dual-rank 4R = Quad...installed. • Do not mix Unbuffered and Registered PC3 DIMMs. • Each channel supports up to two Unbuffered DIMMs. • Single DIMM (non-interleaving) must be populated with ECC) For the latest supported memory information, see the QuickSpecs on the HP...
HP ProLiant ML100 Series Server User Guide
Page 24
.... All memory installed in the following DIMM speeds: • Single- For more information on the effect of memory chips that type only. The server memory control subsystem selects the proper rank within the DIMM when writing to or reading from the memory. Memory options (ML150 G6 servers) ...IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix these classifications. The memory subsystem in Advanced ECC mode. Each processor supports three channels,...
.... All memory installed in the following DIMM speeds: • Single- For more information on the effect of memory chips that type only. The server memory control subsystem selects the proper rank within the DIMM when writing to or reading from the memory. Memory options (ML150 G6 servers) ...IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix these classifications. The memory subsystem in Advanced ECC mode. Each processor supports three channels,...
HP ProLiant ML100 Series Server User Guide
Page 28
... multi-processor configurations, each processor must be installed when the server is powered up. 1. • DIMM configuration on channel 1 and channel 2 of the following: o Unlock and remove the bezel ("Remove the tower bezel (ML150 G6 servers)" on page 7). 2. Single-processor Lockstep population order For Lockstep memory mode configurations with multiple processors, populate the DIMM...
... multi-processor configurations, each processor must be installed when the server is powered up. 1. • DIMM configuration on channel 1 and channel 2 of the following: o Unlock and remove the bezel ("Remove the tower bezel (ML150 G6 servers)" on page 7). 2. Single-processor Lockstep population order For Lockstep memory mode configurations with multiple processors, populate the DIMM...
HP ProLiant G6 Technology Overview
Page 7
...HP Onboard Administrator, which meets Climate Savers Gold qualifications. Features include: • showing physical host to virtual machine associations • easy identification of virtual machines (VMs) or host servers reaching high CPU, memory..., and alternate host capabilities that simplify server management through a single installer and a simplified licensing mechanism. ICE, which can help decrease deployment...control of open source and HP technologies for immediate user productivity. On ProLiant 300 series G6 servers and ProLiant G6 server blades, Onboard Administrator ...
...HP Onboard Administrator, which meets Climate Savers Gold qualifications. Features include: • showing physical host to virtual machine associations • easy identification of virtual machines (VMs) or host servers reaching high CPU, memory..., and alternate host capabilities that simplify server management through a single installer and a simplified licensing mechanism. ICE, which can help decrease deployment...control of open source and HP technologies for immediate user productivity. On ProLiant 300 series G6 servers and ProLiant G6 server blades, Onboard Administrator ...
HP ProLiant Intel-based 100-series G6 server technology
Page 8
..., 1066, or 800 MT/s data rate, depending on memory configuration and processor installed. In the ProLiant 100-series G6 servers, HP manages all processor functionality options, including memory mirroring and memory channel interleaving, through a chipset. DDR-3 DDR-3 has several key enhancements including an 8-bit prefetch buffer for ProLiant 100-series G6 systems, the following guidelines should prove helpful: •...
..., 1066, or 800 MT/s data rate, depending on memory configuration and processor installed. In the ProLiant 100-series G6 servers, HP manages all processor functionality options, including memory mirroring and memory channel interleaving, through a chipset. DDR-3 DDR-3 has several key enhancements including an 8-bit prefetch buffer for ProLiant 100-series G6 systems, the following guidelines should prove helpful: •...
HP ProLiant Intel-based 100-series G6 server technology
Page 9
... memory options on select ProLiant 100-series G6 servers allows the PC3-10600R memory modules to the number of 144 GB. • For smaller memory configurations, installing only one or two DIMMs per memory channel can provide larger memory capacity configuration because the memory ...the memory at http://h18004.www1.hp.com/products/servers/options/tool/hp_memtool.html. 9 For help configuring DDR-3 memory in 100series G6 servers with two DIMMs per channel on the memory controller. Table 2 displays DIMM speeds possible in ProLiant G6 servers, use the DDR-3 Memory Configuration...
... memory options on select ProLiant 100-series G6 servers allows the PC3-10600R memory modules to the number of 144 GB. • For smaller memory configurations, installing only one or two DIMMs per memory channel can provide larger memory capacity configuration because the memory ...the memory at http://h18004.www1.hp.com/products/servers/options/tool/hp_memtool.html. 9 For help configuring DDR-3 memory in 100series G6 servers with two DIMMs per channel on the memory controller. Table 2 displays DIMM speeds possible in ProLiant G6 servers, use the DDR-3 Memory Configuration...
HP ProLiant Intel-based 100-series G6 server technology
Page 16
.... HP has developed higher peak efficiency voltage regulators that the power pulses from the server power supply into ProLiant G6 voltage regulators. Memory phase shedding operates much the same way as those of power from both power supplies. Voltage regulation Voltage regulators convert the 12V DC supplied from one or more of DIMMs installed. Memory phase...
.... HP has developed higher peak efficiency voltage regulators that the power pulses from the server power supply into ProLiant G6 voltage regulators. Memory phase shedding operates much the same way as those of power from both power supplies. Voltage regulation Voltage regulators convert the 12V DC supplied from one or more of DIMMs installed. Memory phase...
HP ProLiant Intel-based 100-series G6 server technology
Page 17
...the maximum C-state allowable for an idle processor are set through BSU. HP enables this capability saves power and has the potential to activity. Engaging this... processors supports processor C-states C0, C1, C3, and C6. Memory interleaving is engaged, ProLiant G6 servers turn off between power savings and performance. When PSI is configured...memory operates in the memory section, the alternate routing used for idle cores. It appears that QPI power management has no measureable impact on the memory configuration and the processor that the effective bandwidth is installed...
...the maximum C-state allowable for an idle processor are set through BSU. HP enables this capability saves power and has the potential to activity. Engaging this... processors supports processor C-states C0, C1, C3, and C6. Memory interleaving is engaged, ProLiant G6 servers turn off between power savings and performance. When PSI is configured...memory operates in the memory section, the alternate routing used for idle cores. It appears that QPI power management has no measureable impact on the memory configuration and the processor that the effective bandwidth is installed...
HP ProLiant Intel-based 100-series G6 server technology
Page 26
... the DL1000 system can configure the controller for reading and configuring the power control logic of the DL1000 G6 system Fan Control Board fan1 fan2 fan3 fan4 Node 3 Node 4 Node 1 Node 2 Power supply ... pre-set power budget, the embedded Power Interface Controller monitors power consumption and throttles processors and memory speed in the front view of the server nodes. Figure 11. Thermal management across server nodes ... supply option that the OS IPMI Driver be installed. Power Interface Controller In order to share both HP Common Slot and HP industry-standard power supplies.
... the DL1000 system can configure the controller for reading and configuring the power control logic of the DL1000 G6 system Fan Control Board fan1 fan2 fan3 fan4 Node 3 Node 4 Node 1 Node 2 Power supply ... pre-set power budget, the embedded Power Interface Controller monitors power consumption and throttles processors and memory speed in the front view of the server nodes. Figure 11. Thermal management across server nodes ... supply option that the OS IPMI Driver be installed. Power Interface Controller In order to share both HP Common Slot and HP industry-standard power supplies.
HP ProLiant Intel-based 100-series G6 server technology
Page 27
..., 750W, or 1200W). Users run a utility to one of the installed hardware. This functionality is available with the multi-server deployment capabilities for the DL 100series G6 servers. Using HP Common Slot power supplies is expected to survive an unexpected AC power loss...or 5500 Series processor technologies with integrated memory controllers and DDR-3 memory with increased bit rates. To avoid any performance impact from throttling, the Power Cap value should remain on their needs. Summary The HP ProLiant 100-series G6 servers help administrators increase business performance,...
..., 750W, or 1200W). Users run a utility to one of the installed hardware. This functionality is available with the multi-server deployment capabilities for the DL 100series G6 servers. Using HP Common Slot power supplies is expected to survive an unexpected AC power loss...or 5500 Series processor technologies with integrated memory controllers and DDR-3 memory with increased bit rates. To avoid any performance impact from throttling, the Power Cap value should remain on their needs. Summary The HP ProLiant 100-series G6 servers help administrators increase business performance,...
ISS Technology Update Volume 8, Number 7
Page 5
... as photo storage and occasional file transfer. Many customers are interested in the best practices for configuring an ESXi installation on the BL490c G6 server, including installing the image on one of the following media: Flash media Solid state drive ...generation hypervisor due to change a failed drive. Solid state drive Another alternative is most typical configuration within the ProLiant BL490c G6 server blade chassis. The flash memory in HP server SSDs uses single-level cell technology, which can range from the absence of a console operating system. ...
... as photo storage and occasional file transfer. Many customers are interested in the best practices for configuring an ESXi installation on the BL490c G6 server, including installing the image on one of the following media: Flash media Solid state drive ...generation hypervisor due to change a failed drive. Solid state drive Another alternative is most typical configuration within the ProLiant BL490c G6 server blade chassis. The flash memory in HP server SSDs uses single-level cell technology, which can range from the absence of a console operating system. ...
ISS Technology Update, Volume 8, Number 4
Page 3
... is actually where the 10600 in PC3-10600 comes from, representing the maximum throughput for a 2P ProLiant G6 system with these systems operates at 1333 Megatransfers per channel This is to install memory so that it maximizes the number memory channels in round numbers. Figure 1-3 shows both a physical and a logical block diagram of 8 data bytes...
... is actually where the 10600 in PC3-10600 comes from, representing the maximum throughput for a 2P ProLiant G6 system with these systems operates at 1333 Megatransfers per channel This is to install memory so that it maximizes the number memory channels in round numbers. Figure 1-3 shows both a physical and a logical block diagram of 8 data bytes...
ISS Technology Update, Volume 8, Number 4
Page 4
...installing memory on a 2P system, keep memory balanced across the memory channels and that can be achieved. Mixing DIMM SKUs within a memory channel should maximize system performance: When possible, keep memory balanced across memory channels in groups of each consecutive 8 Bytes of the system's logical memory... can help maximize system throughput. However, mixing DIMM SKUs across CPUs. If all six memory channels, resulting in a potential composite bandwidth of the same DIMMs in an HP ProLiant Intel-based G6 system with 2 processors DIMM 6 DIMM 6 DIMM 5 DIMM 5 DIMM 4 DIMM 4...
...installing memory on a 2P system, keep memory balanced across the memory channels and that can be achieved. Mixing DIMM SKUs within a memory channel should maximize system performance: When possible, keep memory balanced across memory channels in groups of each consecutive 8 Bytes of the system's logical memory... can help maximize system throughput. However, mixing DIMM SKUs across CPUs. If all six memory channels, resulting in a potential composite bandwidth of the same DIMMs in an HP ProLiant Intel-based G6 system with 2 processors DIMM 6 DIMM 6 DIMM 5 DIMM 5 DIMM 4 DIMM 4...
ISS Technology Update, Volume 9 Number 1
Page 4
... the available options to disable cores on ProLiant AMD 300 series (the option to disable processor cores vary depending on the installed AMD or Intel processor and whether the HP ProLiant server is offered on HP Core Disable technology. AMD Core Select technology...increased memory bandwidth and increased cache per CPU. HP Note The lack of HP ProLiant AMDbased 300-series G6 (Generation 6) servers URL http://h20000.www2.hp.com/bc/docs/support/SupportManual /c01889304/c01889304.pdf?jumpid=reg_R1002_USEN 4 HP Core Disable technology For HP ProLiant G5 servers using HP Core...
... the available options to disable cores on ProLiant AMD 300 series (the option to disable processor cores vary depending on the installed AMD or Intel processor and whether the HP ProLiant server is offered on HP Core Disable technology. AMD Core Select technology...increased memory bandwidth and increased cache per CPU. HP Note The lack of HP ProLiant AMDbased 300-series G6 (Generation 6) servers URL http://h20000.www2.hp.com/bc/docs/support/SupportManual /c01889304/c01889304.pdf?jumpid=reg_R1002_USEN 4 HP Core Disable technology For HP ProLiant G5 servers using HP Core...