HP Power Capping and Dynamic Power Capping for ProLiant servers technology brief, 1st edition
Page 8
... individual power caps will remain in power consumption that server's minimum and maximum power consumption. Many ProLiant G5 servers are changed by the user through Insight Power Manager One of the most powerful uses of supporting Dynamic Power Capping once the appropriate BIOS and iLO ...version 1.70 or later Onboard Administrator firmware version 2.32 or later (for HP BladeSystem enclosures) At introduction, support for the servers until they are capable of power capping is available on ProLiant servers that is assigned an individual power cap. When working with group power...
... individual power caps will remain in power consumption that server's minimum and maximum power consumption. Many ProLiant G5 servers are changed by the user through Insight Power Manager One of the most powerful uses of supporting Dynamic Power Capping once the appropriate BIOS and iLO ...version 1.70 or later Onboard Administrator firmware version 2.32 or later (for HP BladeSystem enclosures) At introduction, support for the servers until they are capable of power capping is available on ProLiant servers that is assigned an individual power cap. When working with group power...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 10
... Pack (RDP) can be managed by HP Systems Insight Manager (HP SIM) if the management agents are not supported. Supported in the Fibre Channel configuration only. Table 2. ProLiant server platforms that support Windows Server 2008 Server platform ProLiant ML350 G4p ROM family ROM date (minimum) D19 07/16/07 ProLiant ML350 G5* D21 08/21/07 ProLiant ML370 G4 P50 07...
... Pack (RDP) can be managed by HP Systems Insight Manager (HP SIM) if the management agents are not supported. Supported in the Fibre Channel configuration only. Table 2. ProLiant server platforms that support Windows Server 2008 Server platform ProLiant ML350 G4p ROM family ROM date (minimum) D19 07/16/07 ProLiant ML350 G5* D21 08/21/07 ProLiant ML370 G4 P50 07...
ISS Technology Update Index
Page 3
... 1 online "double-conversion" technology and online "on HP BladeSystem 10 c7000 enclosures and their components Removing disabled servers from HP Systems Insight 8 Manager S Shut down servers gracefully with the HP ProLiant ML360 5 uninterruptible power supply solution Soft memory errors caused... of HP 6 Gb/s 6 SAS drives PUE and DCE-useful metrics for overall data center 6 efficiency Q Quick tip: Configuring a redundant domain controller 3 when using Fabric Manager software to 6 configure switches R Recommendations for differences in ProLiant 4 300 series G5 and G6...
... 1 online "double-conversion" technology and online "on HP BladeSystem 10 c7000 enclosures and their components Removing disabled servers from HP Systems Insight 8 Manager S Shut down servers gracefully with the HP ProLiant ML360 5 uninterruptible power supply solution Soft memory errors caused... of HP 6 Gb/s 6 SAS drives PUE and DCE-useful metrics for overall data center 6 efficiency Q Quick tip: Configuring a redundant domain controller 3 when using Fabric Manager software to 6 configure switches R Recommendations for differences in ProLiant 4 300 series G5 and G6...
ISS Technology Update Volume 8, Number 5
Page 1
... Microsoft® Windows Server® 2008 Foundation on HP ProLiant servers http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018223 81/c01822381.pdf HP Insight Management Agents architecture for Windows http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018172 servers, 1st edition... Xeon® 90/c01852590.pdf Technologies in HP ProLiant G5 c-Class Server Blades http://h20000.www2.hp.com/bc/docs/support/SupportManual/c011360 96/c01136096.pdf HP Virtual Connect technology for the HP BladeSystem c- http://h20000.www2.hp.com/bc/docs/support/SupportManual/c008141 Class,...
... Microsoft® Windows Server® 2008 Foundation on HP ProLiant servers http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018223 81/c01822381.pdf HP Insight Management Agents architecture for Windows http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018172 servers, 1st edition... Xeon® 90/c01852590.pdf Technologies in HP ProLiant G5 c-Class Server Blades http://h20000.www2.hp.com/bc/docs/support/SupportManual/c011360 96/c01136096.pdf HP Virtual Connect technology for the HP BladeSystem c- http://h20000.www2.hp.com/bc/docs/support/SupportManual/c008141 Class,...
ISS Technology Update Volume 8, Number 7
Page 1
...-V Server 2008 R2 on HP ProLiant servers HP ProLiant DL585 G5/G6 server technology The Intel processor roadmap for industry-standard servers, 10th Edition The AMD processor roadmap for industry-standard servers, 6th Edition HP BladeSystem c-Class SAN connectivity Implementing UPS power management applications with HP Systems Insight Manager, 3rd edition URL http://h20000.www2.hp.com/bc/docs/support/SupportManual...
...-V Server 2008 R2 on HP ProLiant servers HP ProLiant DL585 G5/G6 server technology The Intel processor roadmap for industry-standard servers, 10th Edition The AMD processor roadmap for industry-standard servers, 6th Edition HP BladeSystem c-Class SAN connectivity Implementing UPS power management applications with HP Systems Insight Manager, 3rd edition URL http://h20000.www2.hp.com/bc/docs/support/SupportManual...
ISS Technology Update, Volume 7 Number 1 - Newsletter
Page 11
...a non-redundant fansink for the entire system. Beginning with G5 Intel processor-based systems and G2 AMD processor-based systems, graceful shutdowns can be maintained. The shutdown is logged in Table 5-1. If Insight Agents are installed and configured appropriately, they will terminate POST ... continues to run until thermal sensors reach the hardware protection limit, at 1 The Integrated Management Log (IML) is installed. Failure behavior of models with redundant fans ProLiant DL and ML servers with an operational health driver implement graceful shutdowns 60 seconds after POST...
...a non-redundant fansink for the entire system. Beginning with G5 Intel processor-based systems and G2 AMD processor-based systems, graceful shutdowns can be maintained. The shutdown is logged in Table 5-1. If Insight Agents are installed and configured appropriately, they will terminate POST ... continues to run until thermal sensors reach the hardware protection limit, at 1 The Integrated Management Log (IML) is installed. Failure behavior of models with redundant fans ProLiant DL and ML servers with an operational health driver implement graceful shutdowns 60 seconds after POST...
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 5
...can be allocated to set within the OA or from the power management module within HP Insight Control Environment. The Dynamic Power Cap for the ProLiant DL 380 G5 server, ProLiant BL460c G1 server, and ProLiant BL460c G5 server. blades running lighter workloads will have their power caps increased....at the enclosure level, Dynamic Power Capping takes on workload intensity. The Onboard Administrator, working in conjunction with the iLO 2 management processor, will peak and subside at different times in 5 The first release of servers that enable more intense workloads will ...
...can be allocated to set within the OA or from the power management module within HP Insight Control Environment. The Dynamic Power Cap for the ProLiant DL 380 G5 server, ProLiant BL460c G1 server, and ProLiant BL460c G5 server. blades running lighter workloads will have their power caps increased....at the enclosure level, Dynamic Power Capping takes on workload intensity. The Onboard Administrator, working in conjunction with the iLO 2 management processor, will peak and subside at different times in 5 The first release of servers that enable more intense workloads will ...
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 9
... performance. Steps to the server's application duty cycle. When using the HP Power Calculator default settings for our DL380 G5 TCO benchmark configuration (see Appendix for your ProLiant rack-mount server. The following updates to ensure that aligns to Best ...Practices with caution as a calendar quarter. Based on actual peak power usage. 9 Use HP Power Calculator to establish the initial Dynamic Power Cap for each server IPM update applied to Insight Control Environment central management...
... performance. Steps to the server's application duty cycle. When using the HP Power Calculator default settings for our DL380 G5 TCO benchmark configuration (see Appendix for your ProLiant rack-mount server. The following updates to ensure that aligns to Best ...Practices with caution as a calendar quarter. Based on actual peak power usage. 9 Use HP Power Calculator to establish the initial Dynamic Power Cap for each server IPM update applied to Insight Control Environment central management...
Dynamic Power Capping TCO and Best Practices White Paper (WW edition)
Page 9
...Caps for rack-mount servers Setting Dynamic Power Caps for each server IPM update applied to Insight Control Environment central management server. • Next, download the latest version of HP Power Calculator from the following updates to ensure that aligns to observe power usage for rack...power usage. Please note that may have an adverse impact on the HP Power Calculator output for our ProLiant DL380 G5 configuration, we would set the initial Dynamic Power Cap at 450 Watts. • Using Insight Control Environment, observe peak power usage for a period of supported servers):...
...Caps for rack-mount servers Setting Dynamic Power Caps for each server IPM update applied to Insight Control Environment central management server. • Next, download the latest version of HP Power Calculator from the following updates to ensure that aligns to observe power usage for rack...power usage. Please note that may have an adverse impact on the HP Power Calculator output for our ProLiant DL380 G5 configuration, we would set the initial Dynamic Power Cap at 450 Watts. • Using Insight Control Environment, observe peak power usage for a period of supported servers):...
Technologies for HP ProLiant 100-series G5 (Generation 5) servers, 2nd edition
Page 10
...-effective manageability ProLiant 100-series servers support HP Lights-Out 100 (LO100) Remote Management. HP Rapid Deployment Pack The HP Rapid Deployment Pack (RDP) is plugged into an active power source. HP LO100... is fully accessible using a pre-defined script or a customer-supplied image • Verifies successful image deployment • Provides orientation on HP RDP is firmware that have been optimized to a specific server model (ML110 G5 or ML115 G5...
...-effective manageability ProLiant 100-series servers support HP Lights-Out 100 (LO100) Remote Management. HP Rapid Deployment Pack The HP Rapid Deployment Pack (RDP) is plugged into an active power source. HP LO100... is fully accessible using a pre-defined script or a customer-supplied image • Verifies successful image deployment • Provides orientation on HP RDP is firmware that have been optimized to a specific server model (ML110 G5 or ML115 G5...