Ethernet Card (PCIe) Installation Guide for HP Integrity Servers
Page 3
... systems, and required versions • Support Guides and Users Guides, including detailed maintenance and troubleshooting information Prerequisites Review the prerequisites below before performing any installation. • Review the card, technology, and driver documentation. See "Operating Systems Supported on HP Integrity systems". • Determine the slot in the System Administration section at: http://www.docs...
... systems, and required versions • Support Guides and Users Guides, including detailed maintenance and troubleshooting information Prerequisites Review the prerequisites below before performing any installation. • Review the card, technology, and driver documentation. See "Operating Systems Supported on HP Integrity systems". • Determine the slot in the System Administration section at: http://www.docs...
Ethernet Card (PCIe) Installation Guide for HP Integrity Servers
Page 4
...see the documentation for your version of "Installing the PCIe Card." To install the card, follow these steps: 1. Configuring a Card Using HP-UX on HP Integrity Systems To configure the card on the server (or slot if using CAT 5 or better LAN cable. 3. See "Installing the PCIe... Card". 2. To add new software, use the swinstall command. Review the installation procedures below before continuing the installation procedure to the server. 2....
...see the documentation for your version of "Installing the PCIe Card." To install the card, follow these steps: 1. Configuring a Card Using HP-UX on HP Integrity Systems To configure the card on the server (or slot if using CAT 5 or better LAN cable. 3. See "Installing the PCIe... Card". 2. To add new software, use the swinstall command. Review the installation procedures below before continuing the installation procedure to the server. 2....
FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linux and Windows Installation Guide
Page 17
...install the Windows SCSIPORT miniport driver and Storport miniport driver. • Prerequisites, page 17 • Installing the Windows drivers using the HP Smart Component This section describes how to install the Windows SCSIPORT miniport driver and Storport miniport driver. b. FC HBA section, click Download ...Channel Host Bus Adapters list on which the HBA will operate, and ensure that you have access to standard system documentation. • Review any restrictions or mandatory hotfixes that apply to your HBA appears. e. Save the Smart Component (cp00xxxx.exe) to update ...
...install the Windows SCSIPORT miniport driver and Storport miniport driver. • Prerequisites, page 17 • Installing the Windows drivers using the HP Smart Component This section describes how to install the Windows SCSIPORT miniport driver and Storport miniport driver. b. FC HBA section, click Download ...Channel Host Bus Adapters list on which the HBA will operate, and ensure that you have access to standard system documentation. • Review any restrictions or mandatory hotfixes that apply to your HBA appears. e. Save the Smart Component (cp00xxxx.exe) to update ...
FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linux and Windows Installation Guide
Page 22
... drivers verify the HBA's POST LED states. If there is a failure or a suspected failure, an error log entry is written to determine the HBA status. Review the miniport driver event log codes. Normal; Select Start > Programs > Administrative Tools > Event Viewer, or right-click My Computer and select Manage. 2. Check the POST...
... drivers verify the HBA's POST LED states. If there is a failure or a suspected failure, an error log entry is written to determine the HBA status. Review the miniport driver event log codes. Normal; Select Start > Programs > Administrative Tools > Event Viewer, or right-click My Computer and select Manage. 2. Check the POST...
FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linux and Windows Installation Guide
Page 23
... and keep the card in the log. Do not attempt to decode Storport miniport event log entries using the SCSIPORT miniport documentation, or to review fabric or driver events. You select the ID by the edges. Do not attempt to operate the HBA with the PCI device ID set ...to properly identify and control the HBA. The SCSIPORT and Storport miniport drivers each driver. Review event log information: • For the SCSIPORT miniport driver, see readme.txt. • For the Storport miniport driver, see ELXSTOR Error Log Codes.doc....
... and keep the card in the log. Do not attempt to decode Storport miniport event log entries using the SCSIPORT miniport documentation, or to review fabric or driver events. You select the ID by the edges. Do not attempt to operate the HBA with the PCI device ID set ...to properly identify and control the HBA. The SCSIPORT and Storport miniport drivers each driver. Review event log information: • For the SCSIPORT miniport driver, see readme.txt. • For the Storport miniport driver, see ELXSTOR Error Log Codes.doc....
Generic Site Preparation Guide, Fourth Edition
Page 30
...the sequence of events for sample customer information forms and site inspection checklists. - Final check is arranged with an HP representative to review the inspection checklist and to two days before installation - Site inspection and predelivery coordination meeting is made with the customer...8226; Site Preparation-Schedule with the customer as soon as possible after the order is placed. • Site Verification-Schedule with an HP site preparation specialist to resolve any last-minute problems. NOTE: Not all installations follow a schedule like the one to arrange an ...
...the sequence of events for sample customer information forms and site inspection checklists. - Final check is arranged with an HP representative to review the inspection checklist and to two days before installation - Site inspection and predelivery coordination meeting is made with the customer...8226; Site Preparation-Schedule with the customer as soon as possible after the order is placed. • Site Verification-Schedule with an HP site preparation specialist to resolve any last-minute problems. NOTE: Not all installations follow a schedule like the one to arrange an ...
HP Insight Manager WBEM Provider Events Reference
Page 11
... trap for any important events, then clear it cannot provide more details about the failure. WBEM EventID: 162. Recommended Action: Review the log for Critical or Fatal type E0 event from the target. The system will reboot after the interrupt processing is finished....TOC, or RESET. Probable Cause: An I /O device (or host bridge) detected a bus error. WBEM EventID: 172. Recommended Action: Contact HP Support for additional information. Probable Cause: A sensor reading in a normal configuration. Recommended Action: Read the system logs to replace the failed module....
... trap for any important events, then clear it cannot provide more details about the failure. WBEM EventID: 162. Recommended Action: Review the log for Critical or Fatal type E0 event from the target. The system will reboot after the interrupt processing is finished....TOC, or RESET. Probable Cause: An I /O device (or host bridge) detected a bus error. WBEM EventID: 172. Recommended Action: Contact HP Support for additional information. Probable Cause: A sensor reading in a normal configuration. Recommended Action: Read the system logs to replace the failed module....
HP Insight Manager WBEM Provider Events Reference
Page 21
...Memory error status invalid. WBEM ProviderName: FPL_IndicationProvider. Recommended Action: Contact HP support to NVM corruption. WBEM EventID: 332. Recommended Action: Update system board with current memory controller. Review the preceding events and refer to the users manual to handle..... WBEM EventID: 323. Error adding entry to troubleshoot the problem. Recommended Action: Upgrade to latest system firmware, or contact HP support to PDT. The DIMM distribution check was unable to a full PDT. Recommended action: Update PDC. WBEM ProviderName: FPL_IndicationProvider...
...Memory error status invalid. WBEM ProviderName: FPL_IndicationProvider. Recommended Action: Contact HP support to NVM corruption. WBEM EventID: 332. Recommended Action: Update system board with current memory controller. Review the preceding events and refer to the users manual to handle..... WBEM EventID: 323. Error adding entry to troubleshoot the problem. Recommended Action: Upgrade to latest system firmware, or contact HP support to PDT. The DIMM distribution check was unable to a full PDT. Recommended action: Update PDC. WBEM ProviderName: FPL_IndicationProvider...
HP Insight Manager WBEM Provider Events Reference
Page 25
... 5458 Error 5459 Error 5464 Error 5467 Warning 5468 Warning 5473 Error Event Description Memory fetch timeout. Probable Cause: LBA firmware initialization failed Recommended Action: Review additional error logs to determine exact cause of failure. LBA encountered an uncorrectable parity error. WBEM ProviderName: FPL_IndicationProvider. WBEM EventID: 393. WBEM EventID: 394...
... 5458 Error 5459 Error 5464 Error 5467 Warning 5468 Warning 5473 Error Event Description Memory fetch timeout. Probable Cause: LBA firmware initialization failed Recommended Action: Review additional error logs to determine exact cause of failure. LBA encountered an uncorrectable parity error. WBEM ProviderName: FPL_IndicationProvider. WBEM EventID: 393. WBEM EventID: 394...
HP Insight Manager WBEM Provider Events Reference
Page 31
...MCA to be taken further. WBEM EventID: 444. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. MC_RENDEZVOUS: Rendezvous vector out of MCA. MC_RENDEZVOUS: No MC monarch. Recommended Action: OS or Software...ProviderName: FPL_IndicationProvider. MC_RENDEZVOUS: Get PAL features failed. WBEM EventID: 442. WBEM EventID: 448. WBEM ProviderName: FPL_IndicationProvider. Recommended Action: Review error logs to log or clear I /O error log/clear error. Probable Cause: SFW failed to global MCA. Recommended Action:...
...MCA to be taken further. WBEM EventID: 444. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. MC_RENDEZVOUS: Rendezvous vector out of MCA. MC_RENDEZVOUS: No MC monarch. Recommended Action: OS or Software...ProviderName: FPL_IndicationProvider. MC_RENDEZVOUS: Get PAL features failed. WBEM EventID: 442. WBEM EventID: 448. WBEM ProviderName: FPL_IndicationProvider. Recommended Action: Review error logs to log or clear I /O error log/clear error. Probable Cause: SFW failed to global MCA. Recommended Action:...
HP Insight Manager WBEM Provider Events Reference
Page 64
... Cause: PDH battery power is corrupt. WBEM ProviderName: FPL_IndicationProvider. WBEM EventID: 1766. WBEM EventID: 1767. Recommended Action: Contact HP Support to confirm the CPUs, CC, and cell board are functioning properly. WBEM EventID: 942. Probable Cause: PDC bug. ...WBEM ProviderName: FPL_IndicationProvider. WBEM ProviderName: FPL_IndicationProvider. Failed to check for PDC upgrade. WBEM EventID: 937. Recommended Action: PDC Reviewed alert level for fabric problem. WBEM ProviderName: FPL_IndicationProvider. PDHC has detected the PDH battery low warning. WBEM EventID: 1037...
... Cause: PDH battery power is corrupt. WBEM ProviderName: FPL_IndicationProvider. WBEM EventID: 1766. WBEM EventID: 1767. Recommended Action: Contact HP Support to confirm the CPUs, CC, and cell board are functioning properly. WBEM EventID: 942. Probable Cause: PDC bug. ...WBEM ProviderName: FPL_IndicationProvider. WBEM ProviderName: FPL_IndicationProvider. Failed to check for PDC upgrade. WBEM EventID: 937. Recommended Action: PDC Reviewed alert level for fabric problem. WBEM ProviderName: FPL_IndicationProvider. PDHC has detected the PDH battery low warning. WBEM EventID: 1037...
HP Insight Manager WBEM Provider Events Reference
Page 104
...HP supported DIMMs installed. 104 WBEM Provider Event Tables Recommended Action: More fans may be needed for additional related events. WBEM EventID: 7011. WBEM ProviderName: FPL_IndicationProvider. WBEM EventID: 7014. Recommended Action: Make sure to service a power-on request. WBEM EventID: 6992. Review... network has enough bandwidth and that emitted the event. Recommended Action: Try installing SVB in an improper location. Review the installation documentation for any requests that cannot be left off due to fans or other components. Probable Cause:...
...HP supported DIMMs installed. 104 WBEM Provider Event Tables Recommended Action: More fans may be needed for additional related events. WBEM EventID: 7011. WBEM ProviderName: FPL_IndicationProvider. WBEM EventID: 7014. Recommended Action: Make sure to service a power-on request. WBEM EventID: 6992. Review... network has enough bandwidth and that emitted the event. Recommended Action: Try installing SVB in an improper location. Review the installation documentation for any requests that cannot be left off due to fans or other components. Probable Cause:...
Windows Integrity Management Agents Reference
Page 10
...a possible problem Probable Cause: The power supply fan(s) is not properly seated in system 4. Recommended Action: Continue to monitor unit and contact HP support to clear the problem. 5. BMC entering special mode Probable Cause: BMC entering special mode. Recommended Action: The Special Mode must be ... and contact the vendor of that processors are seated properly in reset or is slowing Recommended Action: Check power supply fan(s). Recommended Action: Review the log for events that would have caused an INIT, TOC, or RESET. SNMP Trap: SystemHW - 733 in HPIFP02TRAP.MIB. hard ...
...a possible problem Probable Cause: The power supply fan(s) is not properly seated in system 4. Recommended Action: Continue to monitor unit and contact HP support to clear the problem. 5. BMC entering special mode Probable Cause: BMC entering special mode. Recommended Action: The Special Mode must be ... and contact the vendor of that processors are seated properly in reset or is slowing Recommended Action: Check power supply fan(s). Recommended Action: Review the log for events that would have caused an INIT, TOC, or RESET. SNMP Trap: SystemHW - 733 in HPIFP02TRAP.MIB. hard ...
Windows Integrity Management Agents Reference
Page 20
... (multiple-bit) ECC error in DIMM Probable Cause: Multiple bit error in DIMM Recommended Action: Contact HP Support personnel to troubleshoot the problem SNMP Trap: hpevtMemMbeInRank - 5204 in HPIFPTRAP.MIB. 20 Management Agents Event Tables Review the preceding events and refer to the users manual to troubleshoot the problem. SNMP Trap: hpevtMemExtFatalLoadOrdErr...
... (multiple-bit) ECC error in DIMM Probable Cause: Multiple bit error in DIMM Recommended Action: Contact HP Support personnel to troubleshoot the problem SNMP Trap: hpevtMemMbeInRank - 5204 in HPIFPTRAP.MIB. 20 Management Agents Event Tables Review the preceding events and refer to the users manual to troubleshoot the problem. SNMP Trap: hpevtMemExtFatalLoadOrdErr...
Windows Integrity Management Agents Reference
Page 24
...: No action required, information only. SNMP Trap: hpevtIoSbaFatalDataParityErr - 5442 in the PCI slot. Recommended Action: Replace I/O chassis. Probable Cause: LBA firmware initialization failed Recommended Action: Review additional error logs to REO parity error on command, rope will vary. Recommended Action: Replace/repair faulty hardware. uncorrectable error discovered on SBA interface. SNMP...
...: No action required, information only. SNMP Trap: hpevtIoSbaFatalDataParityErr - 5442 in the PCI slot. Recommended Action: Replace I/O chassis. Probable Cause: LBA firmware initialization failed Recommended Action: Review additional error logs to REO parity error on command, rope will vary. Recommended Action: Replace/repair faulty hardware. uncorrectable error discovered on SBA interface. SNMP...
Windows Integrity Management Agents Reference
Page 30
...MCA. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. SNMP Trap: hpevtMcPalGetFeatFail - 5657 in HPIFPTRAP.MIB. 30 Management Agents Event Tables Recommended Action: Review error logs to not make the SAL_MC_RENDEZVOUS when there is a specified... BINIT escalation not supported by PAL Probable Cause: Cannot escalate an MCA to re-register vector, if problem persists contact your HP representative for support. If exactly 50% have rendezvoused, and there are rendezvoused, don't boot. SNMP Trap: hpevtMcPalCantEscalateToBerr - 5655...
...MCA. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. SNMP Trap: hpevtMcPalGetFeatFail - 5657 in HPIFPTRAP.MIB. 30 Management Agents Event Tables Recommended Action: Review error logs to not make the SAL_MC_RENDEZVOUS when there is a specified... BINIT escalation not supported by PAL Probable Cause: Cannot escalate an MCA to re-register vector, if problem persists contact your HP representative for support. If exactly 50% have rendezvoused, and there are rendezvoused, don't boot. SNMP Trap: hpevtMcPalCantEscalateToBerr - 5655...
Windows Integrity Management Agents Reference
Page 62
...in HPIFPTRAP.MIB. 9433 Warning Failed to disable the XIN link during a failed link init Probable Cause: Have your HP Support Representative check the Coherency Controller SNMP Trap: hpevtFabricCc2CcLinkDisableErr - 9428 in HPIFPTRAP.MIB. 9418 Warning Power has been removed ... fault has occurred. Probable Cause: A power source has been removed from disk. Recommended Action: PDC Reviewed alert level for deconfiguration. Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board, Cell Power Board and PDH Daughtercard. SNMP Trap: hpevtPdhcDillonResetFailed -...
...in HPIFPTRAP.MIB. 9433 Warning Failed to disable the XIN link during a failed link init Probable Cause: Have your HP Support Representative check the Coherency Controller SNMP Trap: hpevtFabricCc2CcLinkDisableErr - 9428 in HPIFPTRAP.MIB. 9418 Warning Power has been removed ... fault has occurred. Probable Cause: A power source has been removed from disk. Recommended Action: PDC Reviewed alert level for deconfiguration. Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board, Cell Power Board and PDH Daughtercard. SNMP Trap: hpevtPdhcDillonResetFailed -...
Windows Integrity Management Agents Reference
Page 102
If assistance is required, notify the Call Center. Review the installation documentation for additional information. Review the installation documentation for additional information. SNMP Trap: hpevtbldeInstViolateEnclre - 12401 in HPIFPTRAP.MIB. 102 Management Agents Event ... Action: Reset cell that the target has suficient resources. Recommended Action: Try issuing the requests after subsequent requests, please contact the HP representative. If the problem exists even after some time. Recommended Action: Try installing SVB in HPIFPTRAP.MIB. 12547 Error The migration source...
If assistance is required, notify the Call Center. Review the installation documentation for additional information. Review the installation documentation for additional information. SNMP Trap: hpevtbldeInstViolateEnclre - 12401 in HPIFPTRAP.MIB. 102 Management Agents Event ... Action: Reset cell that the target has suficient resources. Recommended Action: Try issuing the requests after subsequent requests, please contact the HP representative. If the problem exists even after some time. Recommended Action: Try installing SVB in HPIFPTRAP.MIB. 12547 Error The migration source...
Cluster Installation and Configuration Guide - Windows Server 2008 and Windows Server 2008 R2
Page 24
... summary statement (by clicking View Report) for example, C:\Windows). For Microsoft discussions of the tests after you to review the details. To view Help topics about whether the cluster is considered a supported configuration. After prompting you close the wizard, see : • http://technet.microsoft....
... summary statement (by clicking View Report) for example, C:\Windows). For Microsoft discussions of the tests after you to review the details. To view Help topics about whether the cluster is considered a supported configuration. After prompting you close the wizard, see : • http://technet.microsoft....