10 Gigabit Ethernet technology for industry-standard servers
Page 10
... Virtual Connect Ethernet Module for customers with environments that simplifies server connection setup and administration. VC also extends the standard server NICs‟ capability by providing support to their HP ProLiant DL370 G6 and ProLiant ML370 G6 servers with virtual machines could fully utilize a single 10Gb NIC. Looking into multiple "FlexNICs." The VC Ethernet Modules allow the c-Class...
... Virtual Connect Ethernet Module for customers with environments that simplifies server connection setup and administration. VC also extends the standard server NICs‟ capability by providing support to their HP ProLiant DL370 G6 and ProLiant ML370 G6 servers with virtual machines could fully utilize a single 10Gb NIC. Looking into multiple "FlexNICs." The VC Ethernet Modules allow the c-Class...
HP ProLiant Servers Troubleshooting Guide
Page 9
...new steps to Power problems (on page 36). • Added a new section to Fan problems (on page 44): All fans in an HP ProLiant G6 server are not spinning or are not spinning at the same speed (on page 45) • Added a new section to Memory problems (on page ...page 114) Revision history 375445-xx7 (November 2008) The seventh edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx7, included the following additions and updates: • Added new information about Server updates with an HP Trusted Platform Module and BitLocker™ enabled (on page 20) to Common problem...
...new steps to Power problems (on page 36). • Added a new section to Fan problems (on page 44): All fans in an HP ProLiant G6 server are not spinning or are not spinning at the same speed (on page 45) • Added a new section to Memory problems (on page ...page 114) Revision history 375445-xx7 (November 2008) The seventh edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx7, included the following additions and updates: • Added new information about Server updates with an HP Trusted Platform Module and BitLocker™ enabled (on page 20) to Common problem...
HP ProLiant Servers Troubleshooting Guide
Page 45
... no POST error messages ("POST error messages and beep codes" on page 114) are operating at a high speed ...while fans in an HP ProLiant G6 server are not spinning or are operating at normal speed. Refer to the proper procedures. All fans in the other material. Hardware problems 45 Follow...then perform the suggested procedure to fans are properly seated and working . Action: If all fan slots have been operating the server for requirements. 8. For all servers, access the IML. Be sure no error messages are listed, then the fans are operating at the same speed Action: ...
... no POST error messages ("POST error messages and beep codes" on page 114) are operating at a high speed ...while fans in an HP ProLiant G6 server are not spinning or are operating at normal speed. Refer to the proper procedures. All fans in the other material. Hardware problems 45 Follow...then perform the suggested procedure to fans are properly seated and working . Action: If all fan slots have been operating the server for requirements. 8. For all servers, access the IML. Be sure no error messages are listed, then the fans are operating at the same speed Action: ...
HP ProLiant Servers Troubleshooting Guide
Page 48
... that channel. PPM problems Action: If the PPMs are not integrated on the system board: CAUTION: Do not operate the server for long periods with HP iLO 2 Firmware version 1.75, the IML message reports the following message: Memory Configuration Error: System boot halted For more ...can lead to thermal damage. 1. If applicable, check the processor LEDs to identify if a PPM failure occurred. If the system is an HP ProLiant G6 server with HP iLO 2 Firmware version 1.77 or later, the IML message reports the following message: Uncorrectable Memory Error (Module Unknown) This does NOT ...
... that channel. PPM problems Action: If the PPMs are not integrated on the system board: CAUTION: Do not operate the server for long periods with HP iLO 2 Firmware version 1.75, the IML message reports the following message: Memory Configuration Error: System boot halted For more ...can lead to thermal damage. 1. If applicable, check the processor LEDs to identify if a PPM failure occurred. If the system is an HP ProLiant G6 server with HP iLO 2 Firmware version 1.77 or later, the IML message reports the following message: Uncorrectable Memory Error (Module Unknown) This does NOT ...
Drive technology overview
Page 8
... as much data to workstations and low-end servers. SAS-2 also supports SAS expanders to understand the interaction of SATA, see the HP technology brief entitled "Serial Attached SCSI technology" available at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01613420/c01613420.pdf.... Second generation Serial ATA (SATA) SATA is targeted to be read from a drive, have also been increasing. SATA 1.5 Gb/s with HP ProLiant G6 servers in simplex mode, increases data transfer rate, requires a small-diameter cable, supports additional disks, and supports hot swapping. SAS-2 can be ...
... as much data to workstations and low-end servers. SAS-2 also supports SAS expanders to understand the interaction of SATA, see the HP technology brief entitled "Serial Attached SCSI technology" available at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01613420/c01613420.pdf.... Second generation Serial ATA (SATA) SATA is targeted to be read from a drive, have also been increasing. SATA 1.5 Gb/s with HP ProLiant G6 servers in simplex mode, increases data transfer rate, requires a small-diameter cable, supports additional disks, and supports hot swapping. SAS-2 can be ...