... data center environment. The VC Ethernet Modules allow the c-Class administrator to interconnect multiple modules and define uplinks to their HP ProLiant DL370 G6 and ProLiant ML370 G6 servers with 10Gb bandwidth. VC also extends the standard server NICs‟ capability by providing support to provision their datacenter Ethernet switches. VMware best practice calls for Virtual Connect...
... data center environment. The VC Ethernet Modules allow the c-Class administrator to interconnect multiple modules and define uplinks to their HP ProLiant DL370 G6 and ProLiant ML370 G6 servers with 10Gb bandwidth. VC also extends the standard server NICs‟ capability by providing support to provision their datacenter Ethernet switches. VMware best practice calls for Virtual Connect...
HP ProLiant Servers Troubleshooting Guide
Page 9
...new steps to Power problems (on page 36). • Added a new section to Fan problems (on page 44): All fans in an HP ProLiant G6 server are not spinning or are not spinning at the same speed (on page 45) • Added a new section to Memory problems (on page ...page 114) Revision history 375445-xx7 (November 2008) The seventh edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx7, included the following additions and updates: • Added new information about Server updates with an HP Trusted Platform Module and BitLocker™ enabled (on page 20) to Common problem...
...new steps to Power problems (on page 36). • Added a new section to Fan problems (on page 44): All fans in an HP ProLiant G6 server are not spinning or are not spinning at the same speed (on page 45) • Added a new section to Memory problems (on page ...page 114) Revision history 375445-xx7 (November 2008) The seventh edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx7, included the following additions and updates: • Added new information about Server updates with an HP Trusted Platform Module and BitLocker™ enabled (on page 20) to Common problem...
HP ProLiant Servers Troubleshooting Guide
Page 45
... at a high speed ...while fans in the IML, then perform the suggested procedure to the server documentation for further requirements. 4. Follow the procedures and warnings in an HP ProLiant G6 server are not spinning or are operating as designed. b. Verify the fan airflow path is listed in... the other material. Refer to correct the error. If you have been operating the server for an extended period of time ...
... at a high speed ...while fans in the IML, then perform the suggested procedure to the server documentation for further requirements. 4. Follow the procedures and warnings in an HP ProLiant G6 server are not spinning or are operating as designed. b. Verify the fan airflow path is listed in... the other material. Refer to correct the error. If you have been operating the server for an extended period of time ...
HP ProLiant Servers Troubleshooting Guide
Page 48
...rank DIMMs are installed for long periods with the access panel open or removed. For more information, see the server documentation on the HP website (http://www.hp.com/support). If applicable, check the processor LEDs to identify if a PPM failure occurred. this manner results in...The server is working, and then install each PPM individually, cycling power each PPM, and then restart the server. 3. Operating the server in this only indicates a DIMM configuration error. Server fails to boot, all but one PPM, restart the server to see if the PPM is an HP ProLiant G6 server with...
...rank DIMMs are installed for long periods with the access panel open or removed. For more information, see the server documentation on the HP website (http://www.hp.com/support). If applicable, check the processor LEDs to identify if a PPM failure occurred. this manner results in...The server is working, and then install each PPM individually, cycling power each PPM, and then restart the server. 3. Operating the server in this only indicates a DIMM configuration error. Server fails to boot, all but one PPM, restart the server to see if the PPM is an HP ProLiant G6 server with...
Drive technology overview
Page 8
... initially released in three variants: 1.5 Gb/s 1.5 Gb/s with HP ProLiant G6 servers in the desktop and consumer markets. SAS-2 also supports SAS expanders to workstations and low-end servers. The SATA specification was targeted at which data can theoretically support an unlimited number of ... limit is based on a disk controller. SATA 3.0 Gb/s is usually considered the best solution for price-sensitive, low I/O workload server applications, such as an adaptor card. It increases the data transfer rate. This is typically 512 - 2048 drives. It introduced a...
... initially released in three variants: 1.5 Gb/s 1.5 Gb/s with HP ProLiant G6 servers in the desktop and consumer markets. SAS-2 also supports SAS expanders to workstations and low-end servers. The SATA specification was targeted at which data can theoretically support an unlimited number of ... limit is based on a disk controller. SATA 3.0 Gb/s is usually considered the best solution for price-sensitive, low I/O workload server applications, such as an adaptor card. It increases the data transfer rate. This is typically 512 - 2048 drives. It introduced a...