Hayward UCL Standard Switched Color Spa 12V 50 Support and Manuals
Get Help and Manuals for this Hayward item
This item is in your list!
View All Support Options Below
Free Hayward UCL Standard Switched Color Spa 12V 50 manuals!
Problems with Hayward UCL Standard Switched Color Spa 12V 50?
Ask a Question
Free Hayward UCL Standard Switched Color Spa 12V 50 manuals!
Problems with Hayward UCL Standard Switched Color Spa 12V 50?
Ask a Question
Popular Hayward UCL Standard Switched Color Spa 12V 50 Manual Pages
ColorLogic-CrystaLogic-Installation-Operation-Manual-092467RevG - Page 2
...safety listed Pool / Spa junction box or junction box trans- former system.
The luminaire is not damaged, cut or spliced except as noted below the normal water level of company Date
LEAVE THESE INSTRUCTIONS WITH PROPERTY OWNER
2
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Disconnect electrical power before installing or servicing this equipment. INSTALLATION DEPTH REQUIREMENT: Except...
ColorLogic-CrystaLogic-Installation-Operation-Manual-092467RevG - Page 3
... up to the top of the lens.
GIVE THESE INSTRUCTIONS TO POOL/SPA OWNER AFTER INSTALLATION
Model LSLxxxxxxx LPLxxxxxxx LPWxxxxxxx
Equivalent Brightness 100W 300W 500W
Lumens 1000 3250 4900
3 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS In stand-alone mode, Universal ColorLogic lights offer 17 different programs; 10 fixed colors, and 7 color shows. 4.
Installation of light and niche must be...
ColorLogic-CrystaLogic-Installation-Operation-Manual-092467RevG - Page 4
...living spaces.
4 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
In some cases, a voltage greater than 4 inches (10 cm) below . The light fixture must be installed in a wall or on performance. To prevent performance problems, verify the transformer is required due to consider the direction of Hayward niches, see installation instructions provided with Local and NEC codes. Be sure to...
ColorLogic-CrystaLogic-Installation-Operation-Manual-092467RevG - Page 5
... (20 cm) above the ground, whichever is greater. If using a wallmount low voltage transformer, a junction box should be installed to make the connection to the power supply, switch panel, pool/spa controller, etc.
5 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Install Junction Box or Junction Box Transformer
When using more information. Additional conduit should be run from the...
ColorLogic-CrystaLogic-Installation-Operation-Manual-092467RevG - Page 9
...specifications and instructions for low-voltage swimming pool and spa lights (Hayward LTBUY11300, Intermatic® model PX100/ PX300, or equivalent). Use wire nuts to connect the field-installed wiring to the power supply. Install...
9 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Up to four Universal ColorLogic/CrystaLogic LED lights (three pool lights max.) can be installed which is agency ...
ColorLogic-CrystaLogic-Installation-Operation-Manual-092467RevG - Page 10
... junction box transformer to fit into various manufacturer's junction boxes. Install Wiring using a Hayward Junction Box Transformer
Hayward offers pool/spa light transformers designed to the pool/spa controller or switch box. Run conduit from pool controller or switch
10 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS These transformers are designed to the ground terminal connections inside the...
ColorLogic-CrystaLogic-Installation-Operation-Manual-092467RevG - Page 11
...for Pool Light 1
Twist Lock Latch
1
Tab Extender
1
ITEM 1 2
Spa Light Parts
PART NUMBER
DESCRIPTION
LQ(x)UY1000
Spa Trim Rings
SPX0800Z1
Metal Light Screw Kit
QTY 1 1
11 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS An LKBUN1000 is designed to the LKBUN1000 installation manual for mounting and wiring instructions.
Together, these components allow the user to be programmed for...
ColorLogic-CrystaLogic-Installation-Operation-Manual-092467RevG - Page 13
...synchronization, all display the same colors and shows at the same time. When the lights come on to white for 15 seconds for programs and operation instructions.
13 UUSSEE OONNLLYY HHAAYYWWAARRDD ...same switch. Once installed, all lights should enter program #1, and be networked, refer to the AQL-COLOR-MODHV ColorLogic Network module for quick clear view of Hayward Pro Logic PS pool/spa ...
ColorLogic-CrystaLogic-Installation-Operation-Manual-092467RevG - Page 14
... for service: PROBLEM: Universal ColorLogic Light will not advance to transformer and then light. Temporarily switch to re-synchronize the lights. SOLUTION2: Make sure that you have a problem with your Hayward Universal ColorLogic/CrystaLogic light, please try the following tips before calling for at least 1 second before turning it is in these instructions to a cooler color (Deep...
Replacing 120V Pool Spa Light With UCL Light Instructions - Page 1
... kit part numbers. Pre-Installation Checklist Existing pool or spa light operates on 120 volts There is a dedicated electrical junction box for the pool/spa light (see Step 1) A suitable transformer has been aquired (refer to compatibility table in manual) If replacing a SwimQuip® light, the tab on electrical wiring and understand electric code requirements and wiring methods
Installation...
Replacing 120V Pool Spa Light With UCL Light Instructions - Page 2
...manual for placing the light on the deck if pool servicing ever requires light removal. Hayward is in the light being inadequately fastened.
Refer to the junction box transformer, install...READ SAFETY INSTRUCTIONS AND COMPLETE SAFETY CHECKLIST INSIDE FRONT COVER OF MANUAL
Hayward (R) is a registered trademark ColorLogic (TM) and CrystaLogic (TM) is not interrupted when installing the new ...
Universal ColorLogic and CrystaLogic Installers/Inspectors Sheet - Page 1
... Engineer at 888-429-9273.
For all other product installation or usage assistance, contact Hayward Technical Support at 888-898-9674. The complete UL Listed ColorLogic System:
Non-conductive, 2 Wire, Sealed, 12V, nonmetallic with the Hayward nonmetallic forming shells (niches) listed below, the 2011 National Electric Code (NEC) provides an exception to the porosity of concrete...
Replacing 12V Pool Spa Light With UCL Light Instructions - Page 1
... electrical wiring and understand electric code requirements and wiring methods
Installation Preparation Read the entire Universal ColorLogic/CrystaLogic manual Read this Guide ONLY if your current light is compatible with Universal ColorLogicTM or CrystaLogicTM
Before you begin
Use this entire Guide
Remove power to the existing pool or spa light at the service panel! STEP 4: Tape Cord...
Replacing 12V Pool Spa Light With UCL Light Instructions - Page 2
... the manual for instructions when using a Hayward Pro Logic controller, an LKBUN1000 coupler must also be adequate for placing the light on the deck if pool servicing ever requires light removal. Plastic gunite type niches will be controlled by Hayward are the property of Hayward Pool Products, Inc. © 2012 Hayward Pool Products, Inc.
Failure to install the...
Universal ColorLogic and CrystaLogic Troubleshooting Guide - Page 5
...
Compatibility
• The AQL-COLOR-MODHV is used with software version 4.10 or greater and whose enclosures provide a cutout for installation. Note: To maximize the ...color, speed, motion and brightness of pre-set light shows in compatible Hayward network lights. Note: an additional relay and network couplers will only operate with Generation 4 or later Hayward ColorLogic 120VAC pool/spa...
Hayward UCL Standard Switched Color Spa 12V 50 Reviews
Do you have an experience with the Hayward UCL Standard Switched Color Spa 12V 50 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Hayward yet.
Earn 750 points for your review!