Owners Manual
Page 3
... Instructions 4 Installation Instructions Location 6 Water piping 7 Electrical 7 Bonding 8 Bonding and plumbing step-by-step instructions 8 Using an External Controller 10 Electrical Connections 11 Wiring Diagram 12 Service Analyzer Control 13 Operation 14 Caring for your Pool Heater 15 Initial Startup 16 Meaning of Display Codes 17 Troubleshooting 18 Requesting Assistance or Service 20 Maintenance 21 Winterizing 21 Hayward® Heat Pump Pool Heater Limited Warranty 22 International Warranty 23 Notes 24 Warranty Card Registration 25 OWNER'S MANUAL
... Instructions 4 Installation Instructions Location 6 Water piping 7 Electrical 7 Bonding 8 Bonding and plumbing step-by-step instructions 8 Using an External Controller 10 Electrical Connections 11 Wiring Diagram 12 Service Analyzer Control 13 Operation 14 Caring for your Pool Heater 15 Initial Startup 16 Meaning of Display Codes 17 Troubleshooting 18 Requesting Assistance or Service 20 Maintenance 21 Winterizing 21 Hayward® Heat Pump Pool Heater Limited Warranty 22 International Warranty 23 Notes 24 Warranty Card Registration 25 OWNER'S MANUAL
Owners Manual
Page 4
... run the heat pump for up to operate for pool heating. This will still heat the pool far more economically than desired pool temperature. As with all industry standards. During warmer weather, the pool cover may be used if night temperatures are 15°F less than other types of pool heaters, such as gas or oil-fired, the SUMMIT pool heat pump has a lower heating capacity on a BTU/hr basis. Therefore, it needs...
... run the heat pump for up to operate for pool heating. This will still heat the pool far more economically than desired pool temperature. As with all industry standards. During warmer weather, the pool cover may be used if night temperatures are 15°F less than other types of pool heaters, such as gas or oil-fired, the SUMMIT pool heat pump has a lower heating capacity on a BTU/hr basis. Therefore, it needs...
Owners Manual
Page 7
... the unit's main ! Proper pool chemistry is open or removed. OWNER'S MANUAL 5 power whenever the access panel is vital to the life of your pool chemistry checked often by an independent pool store. Pay particular attention to the local electrical codes. CAUTION All electrical connections must be done by the manufacturer), while respecting the minimal clearances needed for proper operation and heating. Always install the machine outdoors (unless...
... the unit's main ! Proper pool chemistry is open or removed. OWNER'S MANUAL 5 power whenever the access panel is vital to the life of your pool chemistry checked often by an independent pool store. Pay particular attention to the local electrical codes. CAUTION All electrical connections must be done by the manufacturer), while respecting the minimal clearances needed for proper operation and heating. Always install the machine outdoors (unless...
Owners Manual
Page 8
... your heat pump. Recirculation of cold discharged air back into the building. However, do not forget to a minimum while providing for service and maintenance. The use of 90 degree bends and short radius elbows in a fully enclosed area, such as allowing adequate access for maximum efficiency of operation, as well as a shed, garage, etc. The base should...
... your heat pump. Recirculation of cold discharged air back into the building. However, do not forget to a minimum while providing for service and maintenance. The use of 90 degree bends and short radius elbows in a fully enclosed area, such as allowing adequate access for maximum efficiency of operation, as well as a shed, garage, etc. The base should...
Owners Manual
Page 9
... water circulation for several days, high chlorine gas could cause excessive corrosion. Electrical ! Note: Certain installations have valves which isolate the heat pump from the water circuit. CAUTION The wiring of the heater to minimize harm to the pool equipment. Check the heat pump data label for leaks. Automated chlorine distribution systems, if used, must be used. A properly-sized breaker and copper wire must always be sure that the pool water is drained out of excessive pump head pressure. Water...
... water circulation for several days, high chlorine gas could cause excessive corrosion. Electrical ! Note: Certain installations have valves which isolate the heat pump from the water circuit. CAUTION The wiring of the heater to minimize harm to the pool equipment. Check the heat pump data label for leaks. Automated chlorine distribution systems, if used, must be used. A properly-sized breaker and copper wire must always be sure that the pool water is drained out of excessive pump head pressure. Water...
Owners Manual
Page 10
... bypass plumbing) 8 OWNER'S MANUAL This includes the metal framework of the pool, the light, the pump, the filter (if made out of the heat pump. 3. In these cases, a 6 to balance the water flow. Bonding ! All electric and metal components must be bonded to the copper rod. Any kind of automatic chlorine distribution system must then be installed after or downstream of metal), the heater...
... bypass plumbing) 8 OWNER'S MANUAL This includes the metal framework of the pool, the light, the pump, the filter (if made out of the heat pump. 3. In these cases, a 6 to balance the water flow. Bonding ! All electric and metal components must be bonded to the copper rod. Any kind of automatic chlorine distribution system must then be installed after or downstream of metal), the heater...
Owners Manual
Page 12
... open ) Spa (closed contact puts the board in SPA mode. Using an External Controller To connect the electronic board in order to the NO switch terminals (see FIG. 4). • You can now control the operating mode by using an external switch, follow these steps : • Turn on the heat pump. • Set POOL mode to OFF. • Set SPA mode to the desired temperature. • Access the setup menu. • Select mode E (external) on the P_S menu. • Run two J7 (P_S) terminal wires...
... open ) Spa (closed contact puts the board in SPA mode. Using an External Controller To connect the electronic board in order to the NO switch terminals (see FIG. 4). • You can now control the operating mode by using an external switch, follow these steps : • Turn on the heat pump. • Set POOL mode to OFF. • Set SPA mode to the desired temperature. • Access the setup menu. • Select mode E (external) on the P_S menu. • Run two J7 (P_S) terminal wires...
Owners Manual
Page 13
.... Power requirements 240 V, 1 PH, 60 Hz Look at the name plate located on the left or the right side of the front panel, then slide the electric cable through the knock out located on the heat pump to your local electrical code for additional wiring requirements. Fig. 5 L1 L2 Ground OWNER'S MANUAL 11 The electrical diagram is located on the lid of the pool heater...
.... Power requirements 240 V, 1 PH, 60 Hz Look at the name plate located on the left or the right side of the front panel, then slide the electric cable through the knock out located on the heat pump to your local electrical code for additional wiring requirements. Fig. 5 L1 L2 Ground OWNER'S MANUAL 11 The electrical diagram is located on the lid of the pool heater...
Owners Manual
Page 14
OWNER'S MANUAL 12 HPEC-003 Control Board Water sensor Defrost sensor High pressure switch Closed = OK Opened = high pressure Low pressure switch Closed = OK Opened = low pressure Flow switch Closed = flow Opened = no flow WS DS HP HP LP LP FLO FLO Black Black Light Blue Light Blue Purple Purple COMPRESSOR COMPRESSOR FAN FAN Black Brown Brown FAN CAP CAP S COMPRESSOR R C Yellow Yellow HGD H/C 24 VAC PS Yellow 24 Vac Red Brown Remote switch Pool (opened) Spa (closed) Black Blue 24 Vac transformer Orange (240 Vac) or Red...
OWNER'S MANUAL 12 HPEC-003 Control Board Water sensor Defrost sensor High pressure switch Closed = OK Opened = high pressure Low pressure switch Closed = OK Opened = low pressure Flow switch Closed = flow Opened = no flow WS DS HP HP LP LP FLO FLO Black Black Light Blue Light Blue Purple Purple COMPRESSOR COMPRESSOR FAN FAN Black Brown Brown FAN CAP CAP S COMPRESSOR R C Yellow Yellow HGD H/C 24 VAC PS Yellow 24 Vac Red Brown Remote switch Pool (opened) Spa (closed) Black Blue 24 Vac transformer Orange (240 Vac) or Red...
Owners Manual
Page 16
... pool water temperature in memory: one of the arrow keys, you have chosen. 14 OWNER'S MANUAL To select the pool or spa mode The unit can keep two temperature settings in the mode that you can switch to POL or SPA. The lights on the right side of the arrow keys, you see F_C and by pressing one degree at a time. Operation To increase the temperature...
... pool water temperature in memory: one of the arrow keys, you have chosen. 14 OWNER'S MANUAL To select the pool or spa mode The unit can keep two temperature settings in the mode that you can switch to POL or SPA. The lights on the right side of the arrow keys, you see F_C and by pressing one degree at a time. Operation To increase the temperature...
Owners Manual
Page 18
... water dripping from the holes at the base of the unit. Also make sure that the water circulates freely and that the breaker is important to 4-minute delay. The compressor will need to run 24 hours a day. When the compressor is just condensation. 16 OWNER'S MANUAL Initial Startup ? IMPORTANT Before starting the pool heater for the unit to set the water temperature you will start...
... water dripping from the holes at the base of the unit. Also make sure that the water circulates freely and that the breaker is important to 4-minute delay. The compressor will need to run 24 hours a day. When the compressor is just condensation. 16 OWNER'S MANUAL Initial Startup ? IMPORTANT Before starting the pool heater for the unit to set the water temperature you will start...
Owners Manual
Page 19
... low pressure control. OWNER'S MANUAL 17 Backwash filter and/or heater. The filter is normal operation when outside temperatures are cold. Water pressure switch must be open or defective. The digital display will show HP3 after 3 LP faults and shut down your heater. Pc Water temperature probe is not, the probe may be defective. If it is not, the probe may be adjusted or it is short circuited...
... low pressure control. OWNER'S MANUAL 17 Backwash filter and/or heater. The filter is normal operation when outside temperatures are cold. Water pressure switch must be open or defective. The digital display will show HP3 after 3 LP faults and shut down your heater. Pc Water temperature probe is not, the probe may be defective. If it is not, the probe may be adjusted or it is short circuited...
Owners Manual
Page 20
... a few minutes after the display stops indicating FS. 18 OWNER'S MANUAL Main breaker is reached. The unit is not. Pool pump is not running , but the compressor is on . Turn the pool pump on defrost cycle. Backwash and clean filter. The fan is not running. Raise temperature set to OFF. Desired water temperature is tripped. Heat pump control set point above 60°F (15°C). Troubleshooting The pool heater is running . The compressor will...
... a few minutes after the display stops indicating FS. 18 OWNER'S MANUAL Main breaker is reached. The unit is not. Pool pump is not running , but the compressor is on . Turn the pool pump on defrost cycle. Backwash and clean filter. The fan is not running. Raise temperature set to OFF. Desired water temperature is tripped. Heat pump control set point above 60°F (15°C). Troubleshooting The pool heater is running . The compressor will...
Owners Manual
Page 21
... running. While your heat pump's power supply by running tap water over 5 hours. Evaporator restricted due to see "Location", p.6). OWNER'S MANUAL 19 Restricted water flow. Heat loss is too much for service. Adjust water flow. Clean it can . Ask your electrician to apply. Evaporator is in the unit's service box. Do not use pressurized water as you must stop the heater and leave the pool pump running for the warranty...
... running. While your heat pump's power supply by running tap water over 5 hours. Evaporator restricted due to see "Location", p.6). OWNER'S MANUAL 19 Restricted water flow. Heat loss is too much for service. Adjust water flow. Clean it can . Ask your electrician to apply. Evaporator is in the unit's service box. Do not use pressurized water as you must stop the heater and leave the pool pump running for the warranty...
Owners Manual
Page 22
This information will assure you warranty service. 20 OWNER'S MANUAL CANADA: 1 888 238-7665 USA: 1 908 355-7995 When asking for assistance or service, please check the "Troubleshooting" (pp. 18-19) and "Warranty" (pp. 22-23) sections or call . Proof of purchase will help , follow the instructions below. Warranty may save you still need help us respond properly to your request. It...
This information will assure you warranty service. 20 OWNER'S MANUAL CANADA: 1 888 238-7665 USA: 1 908 355-7995 When asking for assistance or service, please check the "Troubleshooting" (pp. 18-19) and "Warranty" (pp. 22-23) sections or call . Proof of purchase will help , follow the instructions below. Warranty may save you still need help us respond properly to your request. It...
Owners Manual
Page 23
... small aluminum fins. The next step is recommended to cover the heat pump to disconnect the IN and OUT water connections. A protective winter cover is out. OWNER'S MANUAL 21 The cleaning of the plastic cabinet can be drained of a brush and soap. You will have previously been drained. You can accumulate on the evaporator. Then the unit must turn the breaker off.
... small aluminum fins. The next step is recommended to cover the heat pump to disconnect the IN and OUT water connections. A protective winter cover is out. OWNER'S MANUAL 21 The cleaning of the plastic cabinet can be drained of a brush and soap. You will have previously been drained. You can accumulate on the evaporator. Then the unit must turn the breaker off.
Owners Manual
Page 24
HAYWARD will be repaired or replaced and returned transportation charges prepaid, by best and most economical means. 22 OWNER'S MANUAL This warranty applies to erroneous operational reports, external valve position, or electrical service. All parts returned under terms of this warranty must be approved by any HAYWARD part that apply to this warranty due to improper pool chemistry. The compressor component has a five (5) year limited warranty with parts and labor...
HAYWARD will be repaired or replaced and returned transportation charges prepaid, by best and most economical means. 22 OWNER'S MANUAL This warranty applies to erroneous operational reports, external valve position, or electrical service. All parts returned under terms of this warranty must be approved by any HAYWARD part that apply to this warranty due to improper pool chemistry. The compressor component has a five (5) year limited warranty with parts and labor...
Owners Manual
Page 25
... if the product is installed according to units shipped after October 1, 2008 Hayward Pool Products, Inc. 620 Division Street Elizabeth, NJ 07207 OWNER'S MANUAL 23 The compressor is warranted to be free of defects in corrosive environments or atmospheres, conditions beyond the normal intended use of the unit, or acts of God. International Warranty The HAYWARD heat pump pool heater is warranted for...
... if the product is installed according to units shipped after October 1, 2008 Hayward Pool Products, Inc. 620 Division Street Elizabeth, NJ 07207 OWNER'S MANUAL 23 The compressor is warranted to be free of defects in corrosive environments or atmospheres, conditions beyond the normal intended use of the unit, or acts of God. International Warranty The HAYWARD heat pump pool heater is warranted for...
Parts Guide
Page 2
... 18 SIDE PANEL 24 CONTACTOR 27 CONTROL BOARD ASSEMBLY 25 WATER PRESSURE SWITCH 26 TRANSFORMER 23 COMPRESSOR CAPACITOR 7 BENT COIL with GUARD 9 COMPRESSOR 10 CONDENSER 4 FAN MOTOR 2 FAN GUARD 14 ISOLATION KIT 15 ACOUSTICAP 21 TXV ASSEMBLY 29 WATER SENSOR COMPRESSOR ELECT. PLUG(NS) 22 FAN RUN CAPACITOR 28 DEFROST (COIL) SENSOR 5 FAN BLADE 30 LP SWITCH 31 HP SWITCH 11 FILTER DRIER 12 COUPLING PANEL LOCK BOX (NS) SUMMIT HEAT PUMP PARTS EnergyTherm by Summit 5 6 SMX309077021...
... 18 SIDE PANEL 24 CONTACTOR 27 CONTROL BOARD ASSEMBLY 25 WATER PRESSURE SWITCH 26 TRANSFORMER 23 COMPRESSOR CAPACITOR 7 BENT COIL with GUARD 9 COMPRESSOR 10 CONDENSER 4 FAN MOTOR 2 FAN GUARD 14 ISOLATION KIT 15 ACOUSTICAP 21 TXV ASSEMBLY 29 WATER SENSOR COMPRESSOR ELECT. PLUG(NS) 22 FAN RUN CAPACITOR 28 DEFROST (COIL) SENSOR 5 FAN BLADE 30 LP SWITCH 31 HP SWITCH 11 FILTER DRIER 12 COUPLING PANEL LOCK BOX (NS) SUMMIT HEAT PUMP PARTS EnergyTherm by Summit 5 6 SMX309077021...
Parts Guide
Page 3
...HPX11024259 HPX11024258 SMX10024283 SMX306000042 PLUG SUMMIT HEAT PUMP PARTS EasyTemp by Hayward HCB50TA(Canada only) ...Hayward branded (not Heat Pro) HP50TA uses same parts as SUM25TA and will be available in the U.S. 47 Part Description 2 FAN GUARD 3 FAN TOP FAN MOTOR 5 FAN BLADE 7 BENT COIL with GUARD 9 COMPRESSOR 10 CONDENSER 11 FILTER DRIER 12 COUPLING 18 SIDE PANEL 21 TXV ASSEMBLY 22 FAN RUN CAPACITOR 23 COMPRESSOR CAPACITOR 24 CONTACTOR 25 WATER PRESSURE SWITCH 26 TRANSFORMER 27 CONTROL BOARD ASSEMBLY 28 DEFROST (COIL) SENSOR 29 WATER SENSOR...
...HPX11024259 HPX11024258 SMX10024283 SMX306000042 PLUG SUMMIT HEAT PUMP PARTS EasyTemp by Hayward HCB50TA(Canada only) ...Hayward branded (not Heat Pro) HP50TA uses same parts as SUM25TA and will be available in the U.S. 47 Part Description 2 FAN GUARD 3 FAN TOP FAN MOTOR 5 FAN BLADE 7 BENT COIL with GUARD 9 COMPRESSOR 10 CONDENSER 11 FILTER DRIER 12 COUPLING 18 SIDE PANEL 21 TXV ASSEMBLY 22 FAN RUN CAPACITOR 23 COMPRESSOR CAPACITOR 24 CONTACTOR 25 WATER PRESSURE SWITCH 26 TRANSFORMER 27 CONTROL BOARD ASSEMBLY 28 DEFROST (COIL) SENSOR 29 WATER SENSOR...