Owners Manual
Page 8
... wall or from the building foundation wall to prevent the possibility of operation, as well as practical to the existing pool pump and filter to 36" 6 Owner's manual CONSUMER KIT LOCATED BEHIND FRONT PANEL Location The placement of cold discharged air back into the building. ...Recirculation of the pool heater is very important in a fully enclosed area, such as a shed, garage, etc. The size of the base should be completely isolated...
... wall or from the building foundation wall to prevent the possibility of operation, as well as practical to the existing pool pump and filter to 36" 6 Owner's manual CONSUMER KIT LOCATED BEHIND FRONT PANEL Location The placement of cold discharged air back into the building. ...Recirculation of the pool heater is very important in a fully enclosed area, such as a shed, garage, etc. The size of the base should be completely isolated...
Owners Manual
Page 9
... and check the system for several days, high chlorine gas could cause excessive corrosion. All joints should be placed downstream of the heater to minimize harm to circulate through the unit, or is turned off before opening the access panel. Note: Certain installations have valves...pressure. Minimum wire size to the unit is as follows: pool > pool pump > filter > heater > check valve > chemical feeder > pool. Check the heat pump data label for electrical specifications. Then, check the filter pressure gauge to verify that will interrupt all power to be powered off , be ...
... and check the system for several days, high chlorine gas could cause excessive corrosion. All joints should be placed downstream of the heater to minimize harm to circulate through the unit, or is turned off before opening the access panel. Note: Certain installations have valves...pressure. Minimum wire size to the unit is as follows: pool > pool pump > filter > heater > check valve > chemical feeder > pool. Check the heat pump data label for electrical specifications. Then, check the filter pressure gauge to verify that will interrupt all power to be powered off , be ...
Owners Manual
Page 10
A 1/3 lb check valve must be installed between the heater and any automatic chlorine distribution system (if used). 2. Bonding ! The filter must be placed before or upstream from the heat pump. 4. This includes the metal framework of the pool, the light, the pump, the filter (if made out of 75GPM. 8 Owner's manual Any kind of...
A 1/3 lb check valve must be installed between the heater and any automatic chlorine distribution system (if used). 2. Bonding ! The filter must be placed before or upstream from the heat pump. 4. This includes the metal framework of the pool, the light, the pump, the filter (if made out of 75GPM. 8 Owner's manual Any kind of...
Owners Manual
Page 20
... be defective. Backwash filter and/or heater. dPc Suction temperature probe is short circuited or may be adjusted or it is broken. Check water flow. Water pressure switch must be defective. FS Unit currently in backwash position. - This will stop your heater for service. Pc Water... Shortage of codes OFF The desired programmed temperature point is used. If LP or LP3 occurs you should call for protection. The filter is stopped. - Display Meaning of water to WS on the electronic board may be open or defective. Po Water temperature probe ...
... be defective. Backwash filter and/or heater. dPc Suction temperature probe is short circuited or may be adjusted or it is broken. Check water flow. Water pressure switch must be defective. FS Unit currently in backwash position. - This will stop your heater for service. Pc Water... Shortage of codes OFF The desired programmed temperature point is used. If LP or LP3 occurs you should call for protection. The filter is stopped. - Display Meaning of water to WS on the electronic board may be open or defective. Po Water temperature probe ...
Owners Manual
Page 21
Raise temperature set to OFF. Unit will automatically start . Pool pump is not running . Troubleshooting The pool heater is not running . Desired water temperature is in protection mode. Reset main breaker and restart heat pump. The heat pump is reached. ...The compressor will automatically restart when the water temperature goes below the set point. Backwash and clean filter. In this case, there may be a 5-minute delay before restarting. Digital display should indicate FS. Turn the pool pump on defrost cycle. ...
Raise temperature set to OFF. Unit will automatically start . Pool pump is not running . Troubleshooting The pool heater is not running . Desired water temperature is in protection mode. Reset main breaker and restart heat pump. The heat pump is reached. ...The compressor will automatically restart when the water temperature goes below the set point. Backwash and clean filter. In this case, there may be a 5-minute delay before restarting. Digital display should indicate FS. Turn the pool pump on defrost cycle. ...