Owners Manual
Page 3
...-step instructions 8 Installation in Combination with Solar or Gas Heaters 10 Using an External Controller 11 Electrical Connections 12 Wiring Diagram 13 Service Analyzer Control 14 Operation 15 Caring for your Pool Heater 16 Initial Startup 17 Meaning of Display Codes 18 Troubleshooting ...19 Requesting Assistance or Service 21 Maintenance 22 Winterizing 22 Hayward® Heat Pump Pool Heater Limited Warranty 23 ...
...-step instructions 8 Installation in Combination with Solar or Gas Heaters 10 Using an External Controller 11 Electrical Connections 12 Wiring Diagram 13 Service Analyzer Control 14 Operation 15 Caring for your Pool Heater 16 Initial Startup 17 Meaning of Display Codes 18 Troubleshooting ...19 Requesting Assistance or Service 21 Maintenance 22 Winterizing 22 Hayward® Heat Pump Pool Heater Limited Warranty 23 ...
Owners Manual
Page 13
...mode: • Open contact = POOL mode • Closed contact = SPA mode Control using a switch To control the board using this menu. Therefore, a board set to OFF in POOL mode and to the NO switch terminals (see FIG. 4). • You can now control the operating mode by using an external switch, follow these steps... mode E (external) on the P_S menu. • Run two J7 (P_S) terminal wires from the HPEC-003 board to 80 degrees in SPA mode can be controlled with an external switch to heat up to control it remotely, use the P_S terminals on the right side of the board. Using an External...
...mode: • Open contact = POOL mode • Closed contact = SPA mode Control using a switch To control the board using this menu. Therefore, a board set to OFF in POOL mode and to the NO switch terminals (see FIG. 4). • You can now control the operating mode by using an external switch, follow these steps... mode E (external) on the P_S menu. • Run two J7 (P_S) terminal wires from the HPEC-003 board to 80 degrees in SPA mode can be controlled with an external switch to heat up to control it remotely, use the P_S terminals on the right side of the board. Using an External...
Owners Manual
Page 14
...code for additional wiring requirements. Power requirements 240 V, 1 PH, 60 Hz Look at the name plate located on the lid of the control box as well as in the control box. To connect the electricity, you must unscrew the five screws of the front panel, then slide the electric cable through the... knock out located on the left or the right side of the pool heater should be performed by a certified electrician. Fig. 5 L1 L2 ...
...code for additional wiring requirements. Power requirements 240 V, 1 PH, 60 Hz Look at the name plate located on the lid of the control box as well as in the control box. To connect the electricity, you must unscrew the five screws of the front panel, then slide the electric cable through the... knock out located on the left or the right side of the pool heater should be performed by a certified electrician. Fig. 5 L1 L2 ...
Owners Manual
Page 15
13 Owner's manual HPEC-003 Control Board Water sensor Defrost sensor High pressure switch Closed = OK Opened = high pressure Low pressure switch Closed = OK Opened = low pressure Flow switch Closed = flow ... COMPRESSOR FAN FAN Black Brown Brown FAN CAP CAP S COMPRESSOR R C Yellow Yellow HGD H/C 24 VAC PS Yellow 24 Vac Red Brown Remote switch Pool (opened) Spa (closed) Black Blue 24 Vac transformer Orange (240 Vac) or Red (208 Vac) 24 Vac compressor contactor L1 L2 Ground 208 / 230 Vac, 60 Hz...
13 Owner's manual HPEC-003 Control Board Water sensor Defrost sensor High pressure switch Closed = OK Opened = high pressure Low pressure switch Closed = OK Opened = low pressure Flow switch Closed = flow ... COMPRESSOR FAN FAN Black Brown Brown FAN CAP CAP S COMPRESSOR R C Yellow Yellow HGD H/C 24 VAC PS Yellow 24 Vac Red Brown Remote switch Pool (opened) Spa (closed) Black Blue 24 Vac transformer Orange (240 Vac) or Red (208 Vac) 24 Vac compressor contactor L1 L2 Ground 208 / 230 Vac, 60 Hz...
Owners Manual
Page 16
Celsius or Fahrenheit mode Temperature and parameter display Access to parameters Heating mode Compressor ( ) or fan ( ) running Heating mode To raise the desired temperature or to change parameters 14 Owner's manual Service Analyzer Control The control panel is factory set to change parameters To lower the desired temperature or to display the temperature in Fahrenheit degrees.
Celsius or Fahrenheit mode Temperature and parameter display Access to parameters Heating mode Compressor ( ) or fan ( ) running Heating mode To raise the desired temperature or to change parameters 14 Owner's manual Service Analyzer Control The control panel is factory set to change parameters To lower the desired temperature or to display the temperature in Fahrenheit degrees.
Owners Manual
Page 19
... pump is in the ON position. Also make sure that the water circulates freely and that the breaker is activited. IMPORTANT Before starting the pool heater for the unit to see "Service Analyzer Control," p. 13) should be lit.
... pump is in the ON position. Also make sure that the water circulates freely and that the breaker is activited. IMPORTANT Before starting the pool heater for the unit to see "Service Analyzer Control," p. 13) should be lit.
Owners Manual
Page 20
...be defective. Backwash filter and/or heater. The unit will stop your heater for protection. Po Water temperature probe connected to the unit or faulty high pressure control. Shortage of water to DS on the digital display of your pool heater. dPc Suction temperature probe is short... in backwash position. - LP & LP3 Shortage of refrigerant gas in the unit or faulty low pressure control. The digital display will show HP3 after 3 LP faults and shut down your heater. FLo Possible causes: - dPo Suction temperature probe connected to pool pump. - The filter pump is ...
...be defective. Backwash filter and/or heater. The unit will stop your heater for protection. Po Water temperature probe connected to the unit or faulty high pressure control. Shortage of water to DS on the digital display of your pool heater. dPc Suction temperature probe is short... in backwash position. - LP & LP3 Shortage of refrigerant gas in the unit or faulty low pressure control. The digital display will show HP3 after 3 LP faults and shut down your heater. FLo Possible causes: - dPo Suction temperature probe connected to pool pump. - The filter pump is ...
Owners Manual
Page 21
Main breaker is on . The heater is displaying "flo" and it will automatically restart when the water temperature goes below the set point. Turn the pool pump on defrost cycle. Backwash ... compressor will automatically start . Raise temperature set to OFF. Reset main breaker and restart heat pump. Desired water temperature is in protection mode. Heat pump control set point above 60°F (15°C). Filter is not running. Owner's manual 19 Troubleshooting The pool...
Main breaker is on . The heater is displaying "flo" and it will automatically restart when the water temperature goes below the set point. Turn the pool pump on defrost cycle. Backwash ... compressor will automatically start . Raise temperature set to OFF. Reset main breaker and restart heat pump. Desired water temperature is in protection mode. Heat pump control set point above 60°F (15°C). Filter is not running. Owner's manual 19 Troubleshooting The pool...