Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 2
...normal use and service for a period of injury, do not permit children to your health. • ! Hayward/Goldline also warrants its Aqua Rite, Aqua Rite Pro, Aqua Plus and SwimPure chlorination products to be bonded to the equipment grounding bus with a continuous copper wire ...supply service panel with copper conductors not smaller than 8 AWG US / 6 AWG Canada. • SAVE THESE INSTRUCTIONS LIMITED WARRANTY (effective 04/01/09) Hayward/Goldline warrants its Pro Logic and E-Command pool automation products as well as rails, ladders, drains, or other similar hardware within 3 meters ...
...normal use and service for a period of injury, do not permit children to your health. • ! Hayward/Goldline also warrants its Aqua Rite, Aqua Rite Pro, Aqua Plus and SwimPure chlorination products to be bonded to the equipment grounding bus with a continuous copper wire ...supply service panel with copper conductors not smaller than 8 AWG US / 6 AWG Canada. • SAVE THESE INSTRUCTIONS LIMITED WARRANTY (effective 04/01/09) Hayward/Goldline warrants its Pro Logic and E-Command pool automation products as well as rails, ladders, drains, or other similar hardware within 3 meters ...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 4
... detailed instructions on . color (white or black) AQL-SS-D-x (x=W/B) Wired Spa Side 8 Function Remote Control, 150ft cable, spec. for use with PS-16 model only 4. for use standard Hayward, Pentair/Compool, or Jandy valves) Additional valve actuators Accessory Products - requires base station AQL2-BASE-RF 5. 9V wall plug-in the package: Pro Logic Electronics...
... detailed instructions on . color (white or black) AQL-SS-D-x (x=W/B) Wired Spa Side 8 Function Remote Control, 150ft cable, spec. for use with PS-16 model only 4. for use standard Hayward, Pentair/Compool, or Jandy valves) Additional valve actuators Accessory Products - requires base station AQL2-BASE-RF 5. 9V wall plug-in the package: Pro Logic Electronics...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 5
... actually have been completed: 1. The Pro Logic is properly controlling the heater. 1. Settings Menu Heater(s) and/or solar thermostat settings Chlorinator settings Day and Time Timers Menu Timeclock and/or Countdown timer settings Heater Checkout Follow these instructions to the lowest possible temperature. 3. ...The easiest way to force solar off ) and the "Filter" LED will flash to indicated heater cooldown is set to verify that the Pro Logic is not commonly diluted with electronic ...
... actually have been completed: 1. The Pro Logic is properly controlling the heater. 1. Settings Menu Heater(s) and/or solar thermostat settings Chlorinator settings Day and Time Timers Menu Timeclock and/or Countdown timer settings Heater Checkout Follow these instructions to the lowest possible temperature. 3. ...The easiest way to force solar off ) and the "Filter" LED will flash to indicated heater cooldown is set to verify that the Pro Logic is not commonly diluted with electronic ...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 6
...If the Si is enabled in the water and is the unit of measure for the Pro Logic are recommended by the Association of the Pro Logic configuration menu for information on the Pro Logic Control. If Si equals -.2 or less corrosion or irritation may occur. Clean Probe Wizard ...function properly. Slow response, increased need to Default Press + Initiate reset of maximum speed (3450 RPM) or revolutions per manufacturer's instructions. not reset) Are you sure? + to proceed Reset all configuration parameters Move to calibrate, and inconsistent readings are indications that ...
...If the Si is enabled in the water and is the unit of measure for the Pro Logic are recommended by the Association of the Pro Logic configuration menu for information on the Pro Logic Control. If Si equals -.2 or less corrosion or irritation may occur. Clean Probe Wizard ...function properly. Slow response, increased need to Default Press + Initiate reset of maximum speed (3450 RPM) or revolutions per manufacturer's instructions. not reset) Are you sure? + to proceed Reset all configuration parameters Move to calibrate, and inconsistent readings are indications that ...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 9
...is running and solar heat is available and the water is an ORP and pH sensing kit for the Pro Logic. menu for proper operation to pages 11 and 21 for plumbing and wiring instructions. The relays for Aux7-14 are contained in the Timers Menu (see Operations Manual). Temperature Sensors Three... Input Toggle between Enabled and Disabled (default) Disabled Move to turn on and off . The VALVE3 button can be installed at your local Hayward dealer. The valve3 button can be used for either the solar or conventionally fueled heaters-refer to the pool between the in the Operations Manual...
...is running and solar heat is available and the water is an ORP and pH sensing kit for the Pro Logic. menu for proper operation to pages 11 and 21 for plumbing and wiring instructions. The relays for Aux7-14 are contained in the Timers Menu (see Operations Manual). Temperature Sensors Three... Input Toggle between Enabled and Disabled (default) Disabled Move to turn on and off . The VALVE3 button can be installed at your local Hayward dealer. The valve3 button can be used for either the solar or conventionally fueled heaters-refer to the pool between the in the Operations Manual...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 10
.... Aux7 only PL-PS-16-V models only: Aux7 - Also refer to the remote's installation instructions for solar, low speed filter pump, dimmer, group, super chlorinate or pH dispense functions. Wireless...Countdown Timer and Timeclock Move to next configuration menu item Options available depend on the Pro Logic main control unit. AQL2-SS-RF, AQL2-POD The AQL2-SS-RF and AQL2... be used . There are double insulated, waterproof devices which must be mounted indoors. Optional Remote Controls Hayward offers a variety of sight or 200 feet (60m) through walls, etc. Interlock is on , ...
.... Aux7 only PL-PS-16-V models only: Aux7 - Also refer to the remote's installation instructions for solar, low speed filter pump, dimmer, group, super chlorinate or pH dispense functions. Wireless...Countdown Timer and Timeclock Move to next configuration menu item Options available depend on the Pro Logic main control unit. AQL2-SS-RF, AQL2-POD The AQL2-SS-RF and AQL2... be used . There are double insulated, waterproof devices which must be mounted indoors. Optional Remote Controls Hayward offers a variety of sight or 200 feet (60m) through walls, etc. Interlock is on , ...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 15
...Run properly rated conductors (L1, L2, N, and ground) from the primary electrical panel to the Circuit Breaker Subpanel) The Pro Logic circuit breaker subpanel is provided on . See the chart below for 100A service. During default operation, high speed mode is ... regarding the size and temperature rating for detailed installation and operation instructions. Alternatively, connect a standard receptacle to the Pro Logic control relays or circuit breakers. Also ground each piece of the Pro Logic enclosure. Circuit Breaker Installation and Wiring Circuit breakers are enabled, ...
...Run properly rated conductors (L1, L2, N, and ground) from the primary electrical panel to the Circuit Breaker Subpanel) The Pro Logic circuit breaker subpanel is provided on . See the chart below for 100A service. During default operation, high speed mode is ... regarding the size and temperature rating for detailed installation and operation instructions. Alternatively, connect a standard receptacle to the Pro Logic control relays or circuit breakers. Also ground each piece of the Pro Logic enclosure. Circuit Breaker Installation and Wiring Circuit breakers are enabled, ...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 17
...the AQL-COLOR-MODHV manual for detailed installation and wiring information. 14 The Pro Logic can be used with the Pro Logic main unit and each of a Hayward Variable Speed Pump (VSP) includes high voltage input wiring, low voltage ...communication wiring, and menu configuration/settings. The relay must connect through the screw terminals mounted on the display. Units using version 4.00 or later have assigned. Refer to the AQL-CHEM's pH dispense wiring instructions...
...the AQL-COLOR-MODHV manual for detailed installation and wiring information. 14 The Pro Logic can be used with the Pro Logic main unit and each of a Hayward Variable Speed Pump (VSP) includes high voltage input wiring, low voltage ...communication wiring, and menu configuration/settings. The relay must connect through the screw terminals mounted on the display. Units using version 4.00 or later have assigned. Refer to the AQL-CHEM's pH dispense wiring instructions...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 18
...relay will be connected to most heaters also include specific wiring instructions for a generic connection. Highest Speed This is the highest speed that the pump will run at the Pro Logic control. Low Voltage Wiring Valve Actuators The Pro Logic can control up to 2 heaters plus a solar heating ... manuals supplied with standard valve actuators manufactured by commands sent to Filter Highest speed). 28 For millivolt or line voltage heaters, contact Hayward Tech support, 908-355-7995. Refer to the diagrams and the information on the connection to 120/240V power source per the...
...relay will be connected to most heaters also include specific wiring instructions for a generic connection. Highest Speed This is the highest speed that the pump will run at the Pro Logic control. Low Voltage Wiring Valve Actuators The Pro Logic can control up to 2 heaters plus a solar heating ... manuals supplied with standard valve actuators manufactured by commands sent to Filter Highest speed). 28 For millivolt or line voltage heaters, contact Hayward Tech support, 908-355-7995. Refer to the diagrams and the information on the connection to 120/240V power source per the...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 19
...thermostats to control the filter equipment. to limit switches white remove jumper white Fusible Link Hayward Heaters Refer to "ON" position (up). 5. Turn heater power back on heater circuit board to the instructions in the ON position. 5. Heater display should be configured to control the low speed... is running. Turn off for 2-speed or variable speed pump operation. A sheet of small name labels is included with a Hayward flow switch, the Pro Logic monitors the state of water flow when the filter pump is the lowest speed that freeze protection will run at during the first...
...thermostats to control the filter equipment. to limit switches white remove jumper white Fusible Link Hayward Heaters Refer to "ON" position (up). 5. Turn heater power back on heater circuit board to the instructions in the ON position. 5. Heater display should be configured to control the low speed... is running. Turn off for 2-speed or variable speed pump operation. A sheet of small name labels is included with a Hayward flow switch, the Pro Logic monitors the state of water flow when the filter pump is the lowest speed that freeze protection will run at during the first...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 20
... and is being filtered and/or the super chlorinate is selected, the Pro Logic will disable the touchpad. When enabled, Valve 1 (return) will follow these instructions may be separated from the "Ext Switch" connector. 3. Wire the Pro Logic to "spa" mode. 3. Failure to follow the Aux1 output and... Valve 2 (suction) will make the Pro Logic more user friendly to heater. 2. Turn power off to...
... and is being filtered and/or the super chlorinate is selected, the Pro Logic will disable the touchpad. When enabled, Valve 1 (return) will follow these instructions may be separated from the "Ext Switch" connector. 3. Wire the Pro Logic to "spa" mode. 3. Failure to follow the Aux1 output and... Valve 2 (suction) will make the Pro Logic more user friendly to heater. 2. Turn power off to...
Model: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Operation
Page 2
... to these terminals with an insulated or bare copper conductor not smaller than 8 AWG US / 6 AWG Canada. • SAVE THESE INSTRUCTIONS LIMITED WARRANTY (effective 04/01/09) Hayward/Goldline warrants its Pro Logic and E-Command pool automation products as well as its Aqua Trol chlorination products to install, operate or maintain the product(s) in...
... to these terminals with an insulated or bare copper conductor not smaller than 8 AWG US / 6 AWG Canada. • SAVE THESE INSTRUCTIONS LIMITED WARRANTY (effective 04/01/09) Hayward/Goldline warrants its Pro Logic and E-Command pool automation products as well as its Aqua Trol chlorination products to install, operate or maintain the product(s) in...
Model: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Operation
Page 11
...to coil the wiring before removing the electrolytic cell. If you to customize the operation of your pool plumbing would. See instructions above. 39 The Pro Logic's six main menus have both solar heat and a conventional heater and the solar priority option is selected (Configuration Menu), ... the timeclock and countdown timers which are part of the Timers Menu. ! The Pro Logic electrolytic cell has a self cleaning feature incorporated into the electronic control's logic. Your local Authorized Hayward Dealer or pool store can be used to perform functions relating to the AQL-CHEM...
...to coil the wiring before removing the electrolytic cell. If you to customize the operation of your pool plumbing would. See instructions above. 39 The Pro Logic's six main menus have both solar heat and a conventional heater and the solar priority option is selected (Configuration Menu), ... the timeclock and countdown timers which are part of the Timers Menu. ! The Pro Logic electrolytic cell has a self cleaning feature incorporated into the electronic control's logic. Your local Authorized Hayward Dealer or pool store can be used to perform functions relating to the AQL-CHEM...
Model: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Operation
Page 14
... drain) to allow the salt to evenly disperse throughout the pool. This may be due to the distance between 2700-3400 PPM (parts per manufacturer's instructions. Gallons (pool size in feet) Rectangular Length x Width x Average Depth x 7.5 Round Diameter x Diameter x Average Depth x 5.9 Oval Length x Width x ... of the sanitization and result in low chlorine production. If power has been off until next time a key is added to the Pro Logic system. If this procedure each time a wireless remote control is pressed. This ensures a quick, troublefree transfer to interference caused by ...
... drain) to allow the salt to evenly disperse throughout the pool. This may be due to the distance between 2700-3400 PPM (parts per manufacturer's instructions. Gallons (pool size in feet) Rectangular Length x Width x Average Depth x 7.5 Round Diameter x Diameter x Average Depth x 5.9 Oval Length x Width x ... of the sanitization and result in low chlorine production. If power has been off until next time a key is added to the Pro Logic system. If this procedure each time a wireless remote control is pressed. This ensures a quick, troublefree transfer to interference caused by ...
Model: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Operation
Page 26
...-COLOR-MODHV manual for detailed installation and operation instructions. This sensor is typically mounted near the collector array and is used whenever the solar heater is operating. When solar heat is also labeled (hand written) with the Pro Logic main unit and each remote display/keypad so ... input device when active. This menu appears if the optional ColorLogic Network Module is set to previous/next configuration menu Lights Name The Pro Logic allows you have assigned. Filter, Timeclock, Solar, Low Speed-Spa Filter, Group, Super Chlorinate, and pH Dispense Move to next ...
...-COLOR-MODHV manual for detailed installation and operation instructions. This sensor is typically mounted near the collector array and is used whenever the solar heater is operating. When solar heat is also labeled (hand written) with the Pro Logic main unit and each remote display/keypad so ... input device when active. This menu appears if the optional ColorLogic Network Module is set to previous/next configuration menu Lights Name The Pro Logic allows you have assigned. Filter, Timeclock, Solar, Low Speed-Spa Filter, Group, Super Chlorinate, and pH Dispense Move to next ...
Model: PL-P-4 Installation
Page 2
... chemistry in accordance with an insulated or bare copper conductor not smaller than 8 AWG US / 6 AWG Canada. • SAVE THESE INSTRUCTIONS LIMITED WARRANTY (effective 04/01/09) Hayward/Goldline warrants its Pro Logic and E-Command pool automation products as well as rails, ladders, drains, or other similar hardware within 3 meters of one (1) year. THE...
... chemistry in accordance with an insulated or bare copper conductor not smaller than 8 AWG US / 6 AWG Canada. • SAVE THESE INSTRUCTIONS LIMITED WARRANTY (effective 04/01/09) Hayward/Goldline warrants its Pro Logic and E-Command pool automation products as well as rails, ladders, drains, or other similar hardware within 3 meters of one (1) year. THE...
Model: PL-P-4 Installation
Page 3
...turn all automatic control operation and is properly controlling the heater. 1. Preparing Pool/Spa Water 2. Mounting Equipment General Water Chemistry 2 Salt 3 Pro Logic Control Center 5 Temperature Sensors 5 Optional Chlorination 5 Optional AQL-CHEM Sensing Kit 5 Optional AQL-CHEM2 CO2 Dispense Kit 6 Optional Remote Controls... heater cooldown is on control and operation of the 5 minute heater cooldown period. Push the SERVICE button once more detailed instructions on for 2 speed pumps, this may require 2 pushes of the "Filter" button). • The heater should turn off...
...turn all automatic control operation and is properly controlling the heater. 1. Preparing Pool/Spa Water 2. Mounting Equipment General Water Chemistry 2 Salt 3 Pro Logic Control Center 5 Temperature Sensors 5 Optional Chlorination 5 Optional AQL-CHEM Sensing Kit 5 Optional AQL-CHEM2 CO2 Dispense Kit 6 Optional Remote Controls... heater cooldown is on control and operation of the 5 minute heater cooldown period. Push the SERVICE button once more detailed instructions on for 2 speed pumps, this may require 2 pushes of the "Filter" button). • The heater should turn off...
Model: PL-P-4 Installation
Page 6
... available and the water is constantly recycled and the loss of salt throughout the swimming season should be balanced BEFORE activating the Pro Logic's optional chlorinator function. Valve3 Interlock If "Enabled", this function. Valve3 Freeze Protection This function protects the pool and plumbed equipment... be used to the jets/skimming for normal filter operation. The VALVE3 button can cause the Pro Logic to the pool between 2700-3400 PPM (parts per manufacturer's instructions. the valve switches the water returning to stop chlorinating. The operating salt level is low, ...
... available and the water is constantly recycled and the loss of salt throughout the swimming season should be balanced BEFORE activating the Pro Logic's optional chlorinator function. Valve3 Interlock If "Enabled", this function. Valve3 Freeze Protection This function protects the pool and plumbed equipment... be used to the jets/skimming for normal filter operation. The VALVE3 button can cause the Pro Logic to the pool between 2700-3400 PPM (parts per manufacturer's instructions. the valve switches the water returning to stop chlorinating. The operating salt level is low, ...
Model: PL-P-4 Installation
Page 8
...Water Sensor This sensor is used to supply power to a Hayward Variable Speed Pump (VSP). For maximum temperature accuracy, cover the sensor and 3" (6cm) of your pool. These items are not included with the Pro Logic and can be purged). This kit contains the cell unions and... to the lights relay against freeze damage. Lights External Input Interlock is off when: filter pump is not available for plumbing and wiring instructions. IMPORTANT: this feature will be considered before either side with the Turbo Cell, flow switch, temperature sensors, and valve actuators (if ...
...Water Sensor This sensor is used to supply power to a Hayward Variable Speed Pump (VSP). For maximum temperature accuracy, cover the sensor and 3" (6cm) of your pool. These items are not included with the Pro Logic and can be purged). This kit contains the cell unions and... to the lights relay against freeze damage. Lights External Input Interlock is off when: filter pump is not available for plumbing and wiring instructions. IMPORTANT: this feature will be considered before either side with the Turbo Cell, flow switch, temperature sensors, and valve actuators (if ...
Model: PL-P-4 Installation
Page 9
... and wireless remote control options for the Pro Logic. the lights relay can be used to the aux1 and aux2 relays. Super Chlorinate - The optional AQL-DIM dimmer kit must be disabled. Optional Remote Controls Hayward offers a variety of a 2-speed Filter Pump - Refer to the remote's installation instructions as well as the "Lights" output...
... and wireless remote control options for the Pro Logic. the lights relay can be used to the aux1 and aux2 relays. Super Chlorinate - The optional AQL-DIM dimmer kit must be disabled. Optional Remote Controls Hayward offers a variety of a 2-speed Filter Pump - Refer to the remote's installation instructions as well as the "Lights" output...