Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 1
Pro Logic Automation and Chlorination Installation Manual for models PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-8-V PL-PS-16-V www.haywardnet.com
Pro Logic Automation and Chlorination Installation Manual for models PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-8-V PL-PS-16-V www.haywardnet.com
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 3
System Startup and Checkout 7. Warranty Before You Begin 1 Installation Steps 2 General Water Chemistry 3 Salt 4 Pro Logic Control Center 5 PS-16 Expansion Unit 6 Temperature Sensors 6 Optional Chlorination Function 6 Optional AQL-CHEM ORP and pH Sensing Kit 6 Optional AQL-COLOR-MODHV ... Cell 11 Flow Switch 11 Main Service 12 Grounding and Bonding 12 Circuit Breaker Installation and Wiring 12 General Purpose Outlet 12 Pro Logic Control Power 13 High Voltage Pool Equipment 13 Low Voltage Wiring 15 Group Function 22 Configuration Menus 24 Maintenance Menu 40 Before...
System Startup and Checkout 7. Warranty Before You Begin 1 Installation Steps 2 General Water Chemistry 3 Salt 4 Pro Logic Control Center 5 PS-16 Expansion Unit 6 Temperature Sensors 6 Optional Chlorination Function 6 Optional AQL-CHEM ORP and pH Sensing Kit 6 Optional AQL-COLOR-MODHV ... Cell 11 Flow Switch 11 Main Service 12 Grounding and Bonding 12 Circuit Breaker Installation and Wiring 12 General Purpose Outlet 12 Pro Logic Control Power 13 High Voltage Pool Equipment 13 Low Voltage Wiring 15 Group Function 22 Configuration Menus 24 Maintenance Menu 40 Before...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 4
... AQL2-BASE-RF 5. 9V wall plug-in the package: Pro Logic Electronics Unit (3) Temperature sensors with 15 ft. (5m) cable, hose clamp Pro Logic Expansion Unit (PS-16 only) What's NOT Included Some of Pro Logic) Mounting hardware (screws, etc.) for mounting Pro Logic and remote display/keypad Valves (use standard Hayward, Pentair/Compool, or Jandy valves) Additional valve actuators...
... AQL2-BASE-RF 5. 9V wall plug-in the package: Pro Logic Electronics Unit (3) Temperature sensors with 15 ft. (5m) cable, hose clamp Pro Logic Expansion Unit (PS-16 only) What's NOT Included Some of Pro Logic) Mounting hardware (screws, etc.) for mounting Pro Logic and remote display/keypad Valves (use standard Hayward, Pentair/Compool, or Jandy valves) Additional valve actuators...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 9
...burrs. 2. Refer to the AQL-COLOR-MODHV for the Pro Logic. Refer to the AQL-CHEM manual for plumbing and wiring instructions. Valve outputs 7-10, in the Pro Logic Control Center. An additional supplied sensor can be installed at your local Hayward dealer. Drill a 3/8" (10mm) diameter hole in ...Kit The AQL-CHEM is installed in the PS-16 Expansion Unit. Optional AQL-COLOR-MODHV ColorLogic Network Module Using the optional AQL-COLOR-MODHV network module, the Pro Logic can fully control the color, speed, motion and brightness of Hayward ColorLogic Generation 4 pool and spa lights as...
...burrs. 2. Refer to the AQL-COLOR-MODHV for the Pro Logic. Refer to the AQL-CHEM manual for plumbing and wiring instructions. Valve outputs 7-10, in the Pro Logic Control Center. An additional supplied sensor can be installed at your local Hayward dealer. Drill a 3/8" (10mm) diameter hole in ...Kit The AQL-CHEM is installed in the PS-16 Expansion Unit. Optional AQL-COLOR-MODHV ColorLogic Network Module Using the optional AQL-COLOR-MODHV network module, the Pro Logic can fully control the color, speed, motion and brightness of Hayward ColorLogic Generation 4 pool and spa lights as...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 10
... wireless remote controls. Optional Remote Controls Hayward offers a variety of outputs on the remote ("4", "8" or "16") must be mounted indoors or in a weather protected area (rain should never hit the unit). AQL2-Wx-PS-x (x=4,8, or 16) The AQL2-Wx-PS-x is 400 feet (120m) line of the Pro Logic main control unit, insert the base...
... wireless remote controls. Optional Remote Controls Hayward offers a variety of outputs on the remote ("4", "8" or "16") must be mounted indoors or in a weather protected area (rain should never hit the unit). AQL2-Wx-PS-x (x=4,8, or 16) The AQL2-Wx-PS-x is 400 feet (120m) line of the Pro Logic main control unit, insert the base...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 15
...pH Dispense Output Subpanel Ground Bus Bar Ground Bus Bar N L2 L1 Bonding Lug(s) Expansion Unit (AQL-PS-16 only) Bonding Lug(s) The Pro Logic Control Center and PS-16 Expansion Unit require both high and low voltage connections. Also ground each piece of suitable circuit breakers...Local" Display 8 High Voltage Relays for PS-8, PS-16 (4 relays for Canada) wire. Low voltage connections will be used. Run properly rated conductors (L1, L2, N, and ground) from the primary electrical panel to the Circuit Breaker Subpanel) The Pro Logic circuit breaker subpanel is provided on the ...
...pH Dispense Output Subpanel Ground Bus Bar Ground Bus Bar N L2 L1 Bonding Lug(s) Expansion Unit (AQL-PS-16 only) Bonding Lug(s) The Pro Logic Control Center and PS-16 Expansion Unit require both high and low voltage connections. Also ground each piece of suitable circuit breakers...Local" Display 8 High Voltage Relays for PS-8, PS-16 (4 relays for Canada) wire. Low voltage connections will be used. Run properly rated conductors (L1, L2, N, and ground) from the primary electrical panel to the Circuit Breaker Subpanel) The Pro Logic circuit breaker subpanel is provided on the ...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 18
... connectors. The "xx" indicates the valve type from the 2 choices below . For millivolt or line voltage heaters, contact Hayward Tech support, 908-355-7995. The Pro Logic provides a set of low voltage dry contacts that contains a valve, actuator, and extra temperature sensor. Kill Switch Thermostat Heater... and the information on the heater to the maximum (hottest) setting. Wire the Pro Logic dry contact heater output per the instructions in -floor cleaner, etc.). Valve3 and Valve4 (Valves3, 4, 7-10 for PS-16) are dedicated to the heater. 2. Refer to 120/240V power source per...
... connectors. The "xx" indicates the valve type from the 2 choices below . For millivolt or line voltage heaters, contact Hayward Tech support, 908-355-7995. The Pro Logic provides a set of low voltage dry contacts that contains a valve, actuator, and extra temperature sensor. Kill Switch Thermostat Heater... and the information on the heater to the maximum (hottest) setting. Wire the Pro Logic dry contact heater output per the instructions in -floor cleaner, etc.). Valve3 and Valve4 (Valves3, 4, 7-10 for PS-16) are dedicated to the heater. 2. Refer to 120/240V power source per...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 23
Refer to 2, etc. Note that the terminals on the main PCB in the Pro Logic control unit. Connect screw terminals "1" to "1", "2" to the Pro Logic Control Center as shown below . PS-16 Expansion Unit 1 2 3 4 Pro Logic Control Center 20 Base Station Plug in the connector from the AQL-CHEM into the "Wireless" connector on the main PCB in...
Refer to 2, etc. Note that the terminals on the main PCB in the Pro Logic control unit. Connect screw terminals "1" to "1", "2" to the Pro Logic Control Center as shown below . PS-16 Expansion Unit 1 2 3 4 Pro Logic Control Center 20 Base Station Plug in the connector from the AQL-CHEM into the "Wireless" connector on the main PCB in...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 26
... will not be programmed to Super Chlorinate the pool or spa while running , go to the PL-PS-4 with each function. The PL-PS-8-V is running a group command. For example, if the Pro Logic is configured for a single heater, "Heater2" will continue until the preset time expires (see Timers Menu...Settings menu and press the +/- Changing the speed setting while the group is activated. The next time the group is activated. PS-8 and PS-16 Virtual Models Pro Logic Virtual models are made at that you do not wish to the normal speed setting. Also, under the Lights menu, the ...
... will not be programmed to Super Chlorinate the pool or spa while running , go to the PL-PS-4 with each function. The PL-PS-8-V is running a group command. For example, if the Pro Logic is configured for a single heater, "Heater2" will continue until the preset time expires (see Timers Menu...Settings menu and press the +/- Changing the speed setting while the group is activated. The next time the group is activated. PS-8 and PS-16 Virtual Models Pro Logic Virtual models are made at that you do not wish to the normal speed setting. Also, under the Lights menu, the ...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 37
menu to control an automatic pool cover. PS-8: Aux1 through Aux14. WARNING: Do not use as a help to assign any one of a number of names (e.g. Aux1 Name The Pro Logic allows you have assigned. At this system at a later date. 34 This is also labeled (hand written) with ...to standard Aux1 Pump Spd Select Settings Menu (default) or desired pump speed (Filter Lowest to Highest) Settings Menu Move to use the Pro Logic to enable freeze protection for normal filter operation. Filter, Timeclock, Solar, Low Speed-Spa Filter, Group, Super Chlorinate, and pH Dispense Move...
menu to control an automatic pool cover. PS-8: Aux1 through Aux14. WARNING: Do not use as a help to assign any one of a number of names (e.g. Aux1 Name The Pro Logic allows you have assigned. At this system at a later date. 34 This is also labeled (hand written) with ...to standard Aux1 Pump Spd Select Settings Menu (default) or desired pump speed (Filter Lowest to Highest) Settings Menu Move to use the Pro Logic to enable freeze protection for normal filter operation. Filter, Timeclock, Solar, Low Speed-Spa Filter, Group, Super Chlorinate, and pH Dispense Move...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 39
...be aware that the most recent Group function that is enabled and the AIR temperature sensor falls below the selected freeze protection temperature, the Pro Logic will be initiated (Manual On/Off, Countdown Timer, or Timeclock) and the second menu selects the desired functions and their respective control ...Super Chlorinate, Group and Manual On/Off Move to next configuration menu item Options available depend on the function that is active. Aux7 only PL-PS-16-V models only: Aux7 - menu to page 22 for solar, low speed filter pump, dimmer, group, super chlorinate, or pH dispense...
...be aware that the most recent Group function that is enabled and the AIR temperature sensor falls below the selected freeze protection temperature, the Pro Logic will be initiated (Manual On/Off, Countdown Timer, or Timeclock) and the second menu selects the desired functions and their respective control ...Super Chlorinate, Group and Manual On/Off Move to next configuration menu item Options available depend on the function that is active. Aux7 only PL-PS-16-V models only: Aux7 - menu to page 22 for solar, low speed filter pump, dimmer, group, super chlorinate, or pH dispense...
Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installation
Page 40
For PS-16, see aux logic on and off when the VALVE3 button is used to each of the hour. ...item for Valve3 and Valve4 are identical. the valve turns on when the VALVE3 button is included with the Pro Logic main unit and each clock hour and then switch to implement either the Heater2 function or the Valve4 function... the function that the "Valve3" (and "Valve4") pushbutton can also be used to previous/next configuration menu Valve3 Name The Pro Logic allows you have assigned. A sheet of names (e.g. Valve3 Function Manual On/Off (default) - Solar heating must be used...
For PS-16, see aux logic on and off when the VALVE3 button is used to each of the hour. ...item for Valve3 and Valve4 are identical. the valve turns on when the VALVE3 button is included with the Pro Logic main unit and each clock hour and then switch to implement either the Heater2 function or the Valve4 function... the function that the "Valve3" (and "Valve4") pushbutton can also be used to previous/next configuration menu Valve3 Name The Pro Logic allows you have assigned. A sheet of names (e.g. Valve3 Function Manual On/Off (default) - Solar heating must be used...
Model: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Operation
Page 1
Pro Logic Automation and Chlorination Operation Manual for models PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-8-V PL-PS-16-V www.hayward.com
Pro Logic Automation and Chlorination Operation Manual for models PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-8-V PL-PS-16-V www.hayward.com
Model: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Operation
Page 4
... (typically located near the pool equipment) or at a display/keypad which is important to completely read through this manual. System Overview The Hayward Pro Logic is a multifunction pool controller used with PS-16 only) 240 VAC Power OUTPUT 120/240V Aux (8) Relays General Purpose 24V Valve Valves (4) Actuators Circuit Breaker Subpanel NOTE: This manual...
... (typically located near the pool equipment) or at a display/keypad which is important to completely read through this manual. System Overview The Hayward Pro Logic is a multifunction pool controller used with PS-16 only) 240 VAC Power OUTPUT 120/240V Aux (8) Relays General Purpose 24V Valve Valves (4) Actuators Circuit Breaker Subpanel NOTE: This manual...
Model: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Operation
Page 7
... turn on again (either manually or automatically), the dimmer output level will be in Hayward Generation 4 or later ColorLogic pool and spa lights. Two Speed Spa Filter Pump: If... and Aux Outputs Standard Relay: Manual operation of all relays (LIGHTS, AUX1 and AUX2 for a PS-8 model, or LIGHTS, AUX1 - ColorLogic Relay: This selection will only appear if an optional ColorLogic...the AIR temperature sensor falls below the preset freeze protection temperature (see Filter Configuration), the Pro Logic will turn on the filter pump to circulate the water. Dimmer Relay: If Lights or...
... turn on again (either manually or automatically), the dimmer output level will be in Hayward Generation 4 or later ColorLogic pool and spa lights. Two Speed Spa Filter Pump: If... and Aux Outputs Standard Relay: Manual operation of all relays (LIGHTS, AUX1 and AUX2 for a PS-8 model, or LIGHTS, AUX1 - ColorLogic Relay: This selection will only appear if an optional ColorLogic...the AIR temperature sensor falls below the preset freeze protection temperature (see Filter Configuration), the Pro Logic will turn on the filter pump to circulate the water. Dimmer Relay: If Lights or...
Model: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Operation
Page 13
... spillover operation. If the filter pump is running due to select custom colors and lightshows for "pool only" or "pool and spa". For PS models using dual equipment, this time. If the filter pump is running , the water temperature, and the amount of salt in 5% increments....Sensing (see AQL-CHEM manual). Pool Chlorinator 60% Adjust the desired chlorinator output for variable speed operation Move to the pool, activate the Pro Logic Super Chlorinate function. Pool Low Speed 50% Adjust the desired low speed for pool (0,1,2,3...9,10,15,20...95,100%) Move to previous/...
... spillover operation. If the filter pump is running due to select custom colors and lightshows for "pool only" or "pool and spa". For PS models using dual equipment, this time. If the filter pump is running , the water temperature, and the amount of salt in 5% increments....Sensing (see AQL-CHEM manual). Pool Chlorinator 60% Adjust the desired chlorinator output for variable speed operation Move to the pool, activate the Pro Logic Super Chlorinate function. Pool Low Speed 50% Adjust the desired low speed for pool (0,1,2,3...9,10,15,20...95,100%) Move to previous/...
Model: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Operation
Page 17
...number timeclock/speed has priority. If there is an overlap in any of the programmed low speed time period. Aux6 configurations are identical. For PS-16 models, Aux1 - The Aux1 output will turn on time- SSeptaDFailytearndT1Ti-malel W8ed:3n0eAsdtaoy 41:00:03P7P or Spa Filter T1-wkend 8:30A... cleaner) can only be because of time when the pump will run at the speed selected for speed1 in the pool-only position-the Pro Logic will run at the designated times. For one speed spa pumps, this programmed time period. These include manual operation, spa operation, or ...
...number timeclock/speed has priority. If there is an overlap in any of the programmed low speed time period. Aux6 configurations are identical. For PS-16 models, Aux1 - The Aux1 output will turn on time- SSeptaDFailytearndT1Ti-malel W8ed:3n0eAsdtaoy 41:00:03P7P or Spa Filter T1-wkend 8:30A... cleaner) can only be because of time when the pump will run at the speed selected for speed1 in the pool-only position-the Pro Logic will run at the designated times. For one speed spa pumps, this programmed time period. These include manual operation, spa operation, or ...
Model: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Operation
Page 20
...running will return to the information below. To change the speed setting while the group is activated. PS-8 and PS-16 Virtual Models Pro Logic Virtual models are similar to standard PS models, but offer additional auxiliary outputs with 4 additional Aux outputs. Refer to the following pages for... or spa while running group commands. The PL-PS-8-V is similar to the PL-PS-4 with limited functionality. The PL-PS-16-V is similar to the PL-PS-8 with 8 additional outputs. Chlor. When the chlorinator is enabled, the Pro Logic will change Chlorinator Enabled Display Salt Cell Type T-...
...running will return to the information below. To change the speed setting while the group is activated. PS-8 and PS-16 Virtual Models Pro Logic Virtual models are similar to standard PS models, but offer additional auxiliary outputs with 4 additional Aux outputs. Refer to the following pages for... or spa while running group commands. The PL-PS-8-V is similar to the PL-PS-4 with limited functionality. The PL-PS-16-V is similar to the PL-PS-8 with 8 additional outputs. Chlor. When the chlorinator is enabled, the Pro Logic will change Chlorinator Enabled Display Salt Cell Type T-...
Model: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Operation
Page 29
... equipment that for the PS-16, Valves7, 8, 9 and 10 are the same as the spa filter. Also note that is wired to each of the lights relay during freeze--see the "Filter Pump Config." PS-16: Aux1 through Aux6. WARNING: Do not use the Pro Logic to use as shown ...below the selected freeze temperature threshold, the Pro Logic will energize the lights relay. Filter, Timeclock, Solar, Low Speed-Spa Filter, Group...
... equipment that for the PS-16, Valves7, 8, 9 and 10 are the same as the spa filter. Also note that is wired to each of the lights relay during freeze--see the "Filter Pump Config." PS-16: Aux1 through Aux6. WARNING: Do not use the Pro Logic to use as shown ...below the selected freeze temperature threshold, the Pro Logic will energize the lights relay. Filter, Timeclock, Solar, Low Speed-Spa Filter, Group...
Model: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Operation
Page 31
...Aux1 External Input Interlock When Aux1 External Input Interlock is enabled, the Aux1 output will override any previous Group function. PL-PS-8-V models only: Aux3 - Aux7 only PL-PS-16-V models only: Aux7 - Aux14 only Aux7 Config. + to view/change Aux7 Name Cleaner Aux7 Relay Standard Aux7 ... the speed of the "Aux1" button. This is enabled and the AIR temperature sensor falls below the selected freeze protection temperature, the Pro Logic will be assigned to enable freeze protection for the main circulation system. IMPORTANT: this only enables operation of the filter pump when the...
...Aux1 External Input Interlock When Aux1 External Input Interlock is enabled, the Aux1 output will override any previous Group function. PL-PS-8-V models only: Aux3 - Aux7 only PL-PS-16-V models only: Aux7 - Aux14 only Aux7 Config. + to view/change Aux7 Name Cleaner Aux7 Relay Standard Aux7 ... the speed of the "Aux1" button. This is enabled and the AIR temperature sensor falls below the selected freeze protection temperature, the Pro Logic will be assigned to enable freeze protection for the main circulation system. IMPORTANT: this only enables operation of the filter pump when the...