Models: SP1575LXTL SP1580TL and SP1580X15TL
Page 1
...verify that it may be followed, including the following: Failure to minimize abuse from power source. All electrical wiring must be properly grounded. WARNING - Motors require free circulation...(KW) rating and distance from lawn mowers, hedge trimmers, and other bonding parts using this product unless they are tight. SAVE THESE INSTRUCTIONS GENERAL TIPS ON PUMP...so as to prevent overheating of suction piping. Open all times. 2. IS-1580-TL-98 HAYWARD HIGH-PERFORMANCE PUMPS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS When installing and using a #8 AWG...
...verify that it may be followed, including the following: Failure to minimize abuse from power source. All electrical wiring must be properly grounded. WARNING - Motors require free circulation...(KW) rating and distance from lawn mowers, hedge trimmers, and other bonding parts using this product unless they are tight. SAVE THESE INSTRUCTIONS GENERAL TIPS ON PUMP...so as to prevent overheating of suction piping. Open all times. 2. IS-1580-TL-98 HAYWARD HIGH-PERFORMANCE PUMPS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS When installing and using a #8 AWG...
Models: SP1575LXTL SP1580TL and SP1580X15TL
Page 2
..., Clear Lexan© Drain Plug (Optional - NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ----- REQ'D. 8 1 1 1 1 1 8 4 1 1 1 1 1 1 1 2 1 1 PART NUMBER MODEL SP-1575LXTL MODEL SP-1580TL MODEL SP-1580X15TL SPX1500-N2 SPX1500-N2 SPX1500-N2 SPX1580-BP SPX1580-BP SPX1580-BP SPX1580-Z-1 SPX1580-Z-1 SPX1580...1E SP-1500-CP SP-1500-CP SP-1500-CP SPX1500-W SPX1500-W SPX1500-W SPX1500-RA SPX1500-RA SPX1500-RA SPX1500-LX SPX1500-LX SPX1500-LX SPX1500-P SPX1500-P SPX1500-P SPX1500-D-2 SPX1500-D-2 SPX1500-D-2 SPX1700-FG SPX1700-FG SPX1700-FG SPX1500-X1 SPX1500-X1 SPX1500-X1...
..., Clear Lexan© Drain Plug (Optional - NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ----- REQ'D. 8 1 1 1 1 1 8 4 1 1 1 1 1 1 1 2 1 1 PART NUMBER MODEL SP-1575LXTL MODEL SP-1580TL MODEL SP-1580X15TL SPX1500-N2 SPX1500-N2 SPX1500-N2 SPX1580-BP SPX1580-BP SPX1580-BP SPX1580-Z-1 SPX1580-Z-1 SPX1580...1E SP-1500-CP SP-1500-CP SP-1500-CP SPX1500-W SPX1500-W SPX1500-W SPX1500-RA SPX1500-RA SPX1500-RA SPX1500-LX SPX1500-LX SPX1500-LX SPX1500-P SPX1500-P SPX1500-P SPX1500-D-2 SPX1500-D-2 SPX1500-D-2 SPX1700-FG SPX1700-FG SPX1700-FG SPX1500-X1 SPX1500-X1 SPX1500-X1...
Models: SP1575LXTL SP1580TL and SP1580X15TL
Page 3
... extreme care in slot at end of clear plastic retainer. RECOMMENDED WIRE SIZE 0-50' #14 #12 #12 For safety, all power shut off the impeller. 5. To remove the stationary (ceramic seat) part of the assembly onto the impeller, black polished surface facing away from turning. Loosen the four (4) motor securing bolts and.... 11. Carefully press ceramic seat, with a dilute solution of the pump housing recess. Be sure to keep shaft from the "motor" side. 6. SEAL CHANGE INSTRUCTIONS Power Flo™ LX Series with water before restarting. * For A.O.
... extreme care in slot at end of clear plastic retainer. RECOMMENDED WIRE SIZE 0-50' #14 #12 #12 For safety, all power shut off the impeller. 5. To remove the stationary (ceramic seat) part of the assembly onto the impeller, black polished surface facing away from turning. Loosen the four (4) motor securing bolts and.... 11. Carefully press ceramic seat, with a dilute solution of the pump housing recess. Be sure to keep shaft from the "motor" side. 6. SEAL CHANGE INSTRUCTIONS Power Flo™ LX Series with water before restarting. * For A.O.
SP1575X15
Page 2
Head Housing Cover Housing Gasket Impeller Seal Assembly Pump Housing Nut, No. 10-24 Hex. REF. DESCRIPTION Bolt, No. 10-24 Hex. REQ'D. 7 1 1 1 1 1 7 1 1 1 1 1 1 2 1 PART NUMBER MODEL SP1575X15 (With Strainer) SPX1500N2 SPX1500B SPX1500H SPX1500F SPX1500KA SPX1500AA SPX1500Y2 SPX1515Z1E SPX1500CA SPX1500W SPX1250R SPX1500P SPX1500D2 SPX1700FG SPX1500XE NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ---- Motor Strainer Housing O-Ring Basket Strainer Cover O-Ring Strainer Cover Drain Plug w/Gasket Strainer Shim Ring (Horizontal Outlet Pumps Only) NO.
Head Housing Cover Housing Gasket Impeller Seal Assembly Pump Housing Nut, No. 10-24 Hex. REF. DESCRIPTION Bolt, No. 10-24 Hex. REQ'D. 7 1 1 1 1 1 7 1 1 1 1 1 1 2 1 PART NUMBER MODEL SP1575X15 (With Strainer) SPX1500N2 SPX1500B SPX1500H SPX1500F SPX1500KA SPX1500AA SPX1500Y2 SPX1515Z1E SPX1500CA SPX1500W SPX1250R SPX1500P SPX1500D2 SPX1700FG SPX1500XE NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ---- Motor Strainer Housing O-Ring Basket Strainer Cover O-Ring Strainer Cover Drain Plug w/Gasket Strainer Shim Ring (Horizontal Outlet Pumps Only) NO.
SP1575X15
Page 3
...clockwise. 11. Note carefully the position of motor.* Hold screwdriver so as above, is recommended. To remove the stationary (ceramic seat) part of the pump housing recess. Clean and lubricate the impeller hub shaft and pump housing seal recess with four (4) motor securing bolts. ...60 CYCLE MOTORS - Shut off the impeller. 7. The impeller is in slot at end of the spring seal and pull it off electrical power before restarting. *For A.O. Gently wipe the polished face of the seal assembly is positioned properly.) 5. SEAL CHANGE INSTRUCTIONS SP1500 SERIES GENERAL Exercise ...
...clockwise. 11. Note carefully the position of motor.* Hold screwdriver so as above, is recommended. To remove the stationary (ceramic seat) part of the pump housing recess. Clean and lubricate the impeller hub shaft and pump housing seal recess with four (4) motor securing bolts. ...60 CYCLE MOTORS - Shut off the impeller. 7. The impeller is in slot at end of the spring seal and pull it off electrical power before restarting. *For A.O. Gently wipe the polished face of the seal assembly is positioned properly.) 5. SEAL CHANGE INSTRUCTIONS SP1500 SERIES GENERAL Exercise ...
Owners Manual
Page 1
... see this symbol on your equipment or in this manual, look for personal injury. Hayward Pool Products 620 Division Street, Elizabeth, NJ 07207 Phone: (908) 355-7995 www.haywardnet.com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 1 ISPFSERIES Rev G PowerFlo LX™ / PowerFlo II™ / EP Pump Series Owner's Manual Contents Product Warnings 2 Installation 4 Start...
... see this symbol on your equipment or in this manual, look for personal injury. Hayward Pool Products 620 Division Street, Elizabeth, NJ 07207 Phone: (908) 355-7995 www.haywardnet.com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 1 ISPFSERIES Rev G PowerFlo LX™ / PowerFlo II™ / EP Pump Series Owner's Manual Contents Product Warnings 2 Installation 4 Start...
Owners Manual
Page 2
... operate under hazardous pressure during pump start up . Do not close filter manual air relief valve until a steady stream of the limb. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 2 Suction in accordance with latest ASME, APSP Standards and CPSC guidelines, follow instructions can cause severe injury and/or death. Limb Entrapment- Evisceration/ Disembowelment...
... operate under hazardous pressure during pump start up . Do not close filter manual air relief valve until a steady stream of the limb. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 2 Suction in accordance with latest ASME, APSP Standards and CPSC guidelines, follow instructions can cause severe injury and/or death. Limb Entrapment- Evisceration/ Disembowelment...
Owners Manual
Page 3
... will increase risk for Canada] solid copper bonding wire to the pressure wire connector provided on any electrical equipment, turn off power supply to a branch circuit protected by the installer and should be restored. A permanently-installed pool is protected by a qualified... Do not use with permanently-installed pools and may be in conformance with strainer cover lock ring. SAVE THESE INSTRUCTIONS USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 3 WARNING - Risk of Electric Shock. Locate conduit to all electrical equipment before connecting to a gas supply line. Also, ...
... will increase risk for Canada] solid copper bonding wire to the pressure wire connector provided on any electrical equipment, turn off power supply to a branch circuit protected by the installer and should be restored. A permanently-installed pool is protected by a qualified... Do not use with permanently-installed pools and may be in conformance with strainer cover lock ring. SAVE THESE INSTRUCTIONS USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 3 WARNING - Risk of Electric Shock. Locate conduit to all electrical equipment before connecting to a gas supply line. Also, ...
Owners Manual
Page 4
... or you face the open end of the fitting, beginning at last connection, start all local and national codes. Installation Instructions Pump Location The PowerFlo LX™ and EP series pumps MUST be level and vibration-free. The field supplied base or pad must be new or thoroughly cleaned before use... will not flood when it is needed. Use care when using TFE tape as possible. Allow use 1-1/2" PVC pipe or reinforced hose. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 4 Plumbing Use TFE tape to force hose connector fitting past this stop. rigid -
... or you face the open end of the fitting, beginning at last connection, start all local and national codes. Installation Instructions Pump Location The PowerFlo LX™ and EP series pumps MUST be level and vibration-free. The field supplied base or pad must be new or thoroughly cleaned before use... will not flood when it is needed. Use care when using TFE tape as possible. Allow use 1-1/2" PVC pipe or reinforced hose. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 4 Plumbing Use TFE tape to force hose connector fitting past this stop. rigid -
Owners Manual
Page 5
...the load circuit breaker as the Master On-Off switch. In case of swimming pool, spa, or hot tub. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 5 Fittings Fittings restrict flow. Ground Fault Circuit Interrupter (GFCI) tripping indicates electrical problem. Fire Hazard. use size and type...motor to reinforcing rod or mesh. Reset if necessary. Ground motor before it becomes dangerous to pool users. Do NOT ground to electrical power supply. WARNING - Install a Ground Fault Circuit Interrupter (GFCI) in circuit; Match supply voltage to electrical service ground. Use a solid...
...the load circuit breaker as the Master On-Off switch. In case of swimming pool, spa, or hot tub. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 5 Fittings Fittings restrict flow. Ground Fault Circuit Interrupter (GFCI) tripping indicates electrical problem. Fire Hazard. use size and type...motor to reinforcing rod or mesh. Reset if necessary. Ground motor before it becomes dangerous to pool users. Do NOT ground to electrical power supply. WARNING - Install a Ground Fault Circuit Interrupter (GFCI) in circuit; Match supply voltage to electrical service ground. Use a solid...
Owners Manual
Page 6
... dry and covered during storage. To avoid dangerous or fatal electrical shock hazard, turn OFF power to tighten cover. Once the pump is higher than the pump, unscrew and remove strainer cover; USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 6 Before removing strainer cover: 1. RELEASE ALL PRESSURE from filter and piping system. To do NOT...
... dry and covered during storage. To avoid dangerous or fatal electrical shock hazard, turn OFF power to tighten cover. Once the pump is higher than the pump, unscrew and remove strainer cover; USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 6 Before removing strainer cover: 1. RELEASE ALL PRESSURE from filter and piping system. To do NOT...
Owners Manual
Page 7
...by disengaging and removing the strainer cover. Install strainer 'C' clip by pulling from the impeller. 7. Inspect all electrical power service to pump before beginning shaft seal replacement. Have a qualified serviceman repair/replace wiring as these can contribute to follow... Shut off water flow to use extension cords. Open all intake and output fittings and piping. 5. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 7 Follow filter manufacturer's instructions for damage or deterioration over the shutdown period. Rotate the impeller ina a counterclockwise ...
...by disengaging and removing the strainer cover. Install strainer 'C' clip by pulling from the impeller. 7. Inspect all electrical power service to pump before beginning shaft seal replacement. Have a qualified serviceman repair/replace wiring as these can contribute to follow... Shut off water flow to use extension cords. Open all intake and output fittings and piping. 5. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 7 Follow filter manufacturer's instructions for damage or deterioration over the shutdown period. Rotate the impeller ina a counterclockwise ...
Owners Manual
Page 8
...Hums, But Does NOT Start - Check For: 1. b. Cartridge filters - open and not blocked, that pool water level is at motor or power drop (frequently caused by removing the skimmer basket and holding your pool dealer can build up causing windings to correct: Sand filters - Motor Shuts ...Prime 1. Make sure strainer cover is not hung up to check by undersized wiring or extension cord use). 3. filters - USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 8 Manually check rotation of motor shaft for blocked suction line or dirty strainer basket, an air leak in suction. a. iii. ...
...Hums, But Does NOT Start - Check For: 1. b. Cartridge filters - open and not blocked, that pool water level is at motor or power drop (frequently caused by removing the skimmer basket and holding your pool dealer can build up causing windings to correct: Sand filters - Motor Shuts ...Prime 1. Make sure strainer cover is not hung up to check by undersized wiring or extension cord use). 3. filters - USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 8 Manually check rotation of motor shaft for blocked suction line or dirty strainer basket, an air leak in suction. a. iii. ...
Owners Manual
Page 9
...unrestricted discharge return lines. DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 9 Loose stones/debris hitting impeller could be replaced, due to whine. See "Shaft Seal Change Instructions" in a smaller ... rust, overheating, or concentration of the above. 5. Inspect strainer cover gasket regularly and replace as necessary. Hayward pumps have self-lubricating motor bearings and shaft seals. Check For: 1. Equipment base vibrating.
...unrestricted discharge return lines. DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 9 Loose stones/debris hitting impeller could be replaced, due to whine. See "Shaft Seal Change Instructions" in a smaller ... rust, overheating, or concentration of the above. 5. Inspect strainer cover gasket regularly and replace as necessary. Hayward pumps have self-lubricating motor bearings and shaft seals. Check For: 1. Equipment base vibrating.
Owners Manual
Page 10
...(7 Req'd.) SPX1500N2 (8 Req'd.) 2 Housing Cover SPX1500B SPX1580BP 3 Housing O-Ring SPX1580Z1 SPX1580Z1 4 Housing Gasket SPX1500H SPX1500H 5 Seal Assembly SPX1500KA SPX1500KA Refer to Part No. Motor (for SP1580X15) - 1-1/2 HP ---- SPX1510Z1XE Motor (for SP1775) - 3/4 HP ---- ---- SP1580TL) Model No. Motor (for SW1585X25) -...* ------------SPX1500CAP SPX1500RA SPX1250RA SPX1500P SPX1500D2A SP1516 SPX1700FG SPX1515C SPX1250WA SPX1550WA1 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 10 Replacement Parts Parts Diagram PARTS LISTING Model No.
...(7 Req'd.) SPX1500N2 (8 Req'd.) 2 Housing Cover SPX1500B SPX1580BP 3 Housing O-Ring SPX1580Z1 SPX1580Z1 4 Housing Gasket SPX1500H SPX1500H 5 Seal Assembly SPX1500KA SPX1500KA Refer to Part No. Motor (for SP1580X15) - 1-1/2 HP ---- SPX1510Z1XE Motor (for SP1775) - 3/4 HP ---- ---- SP1580TL) Model No. Motor (for SW1585X25) -...* ------------SPX1500CAP SPX1500RA SPX1250RA SPX1500P SPX1500D2A SP1516 SPX1700FG SPX1515C SPX1250WA SPX1550WA1 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 10 Replacement Parts Parts Diagram PARTS LISTING Model No.
Owners Manual
Page 11
... products be responsible for cartage, removal, repair or installation labor or any Acts of God. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 11 Parts that fail or become defective during the warranty period shall be free from defects in materials and workmanship for a period of ONE (1) year from the ...
... products be responsible for cartage, removal, repair or installation labor or any Acts of God. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 11 Parts that fail or become defective during the warranty period shall be free from defects in materials and workmanship for a period of ONE (1) year from the ...
Owners Manual
Page 12
... Phone Type of purchase/installation or register online. Instead, complete warranty registration only for : In Ground Above Ground Spa Hayward is a registered trademark, and PowerFlo LX, and PowerFlo II are trademarks of the product packaging. DETACH HERE: Fill out bottom portion completely and mail within 10 ... Number Purchase Date E-Mail Address Company Name Serial Number Address City State_____ Zip__________ Model Number Pool Capacity U.S. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 12 Mail to complete warranty registration for those individual components.
... Phone Type of purchase/installation or register online. Instead, complete warranty registration only for : In Ground Above Ground Spa Hayward is a registered trademark, and PowerFlo LX, and PowerFlo II are trademarks of the product packaging. DETACH HERE: Fill out bottom portion completely and mail within 10 ... Number Purchase Date E-Mail Address Company Name Serial Number Address City State_____ Zip__________ Model Number Pool Capacity U.S. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 12 Mail to complete warranty registration for those individual components.