... lawn mowers, hedge trimmers, and other bonding parts using this product unless they are tight. Risk of electric shock, replace damaged cord immediately. 8. Contact a qualified electrician...to connect unit to use only a properly grounded outlet. Priming time depends on power and allow a reasonable time for priming. NOTE: NSPI-4 Article V, standard for ...WARNING - Locate cord to its original integrity. 3. Never operate the pump without water. IS-1580-TL-98 HAYWARD HIGH-PERFORMANCE PUMPS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS When installing and using a...
... lawn mowers, hedge trimmers, and other bonding parts using this product unless they are tight. Risk of electric shock, replace damaged cord immediately. 8. Contact a qualified electrician...to connect unit to use only a properly grounded outlet. Priming time depends on power and allow a reasonable time for priming. NOTE: NSPI-4 Article V, standard for ...WARNING - Locate cord to its original integrity. 3. Never operate the pump without water. IS-1580-TL-98 HAYWARD HIGH-PERFORMANCE PUMPS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS When installing and using a...
Models: SP1575LXTL SP1580TL and SP1580X15TL
Page 3
...part of the spring seal and pull it off . 1. Press the new spring portion of clear plastic retainer. Carefully insert the motor shaft through the seat assembly, and secure motor to pump...2. Press plastic retainer, with eight (8) bolts and nuts. Clean fiber gasket (replace if necessary) and fasten housing cover to hold shaft from the impeller. 8. ...pump housing. The use of pump housing-O-ring end first. Screw the impeller, with water before restarting. * For A.O. Tighten bolts and nuts alternately and evenly. 12. SEAL CHANGE INSTRUCTIONS Power Flo™ LX...
...part of the spring seal and pull it off . 1. Press the new spring portion of clear plastic retainer. Carefully insert the motor shaft through the seat assembly, and secure motor to pump...2. Press plastic retainer, with eight (8) bolts and nuts. Clean fiber gasket (replace if necessary) and fasten housing cover to hold shaft from the impeller. 8. ...pump housing. The use of pump housing-O-ring end first. Screw the impeller, with water before restarting. * For A.O. Tighten bolts and nuts alternately and evenly. 12. SEAL CHANGE INSTRUCTIONS Power Flo™ LX...
SP1575X15
Page 3
...5. Clean flat gasket (replace if necessary) and fasten housing cover to pump housing with strainer attached) by removing the seven (7) housing bolts and nuts which fasten housing cover to pump housing with a dilute solution... the impeller in slot at end of the spring seal and pull it off electrical power before restarting. *For A.O. Note carefully the position of motor.* Hold screwdriver so as...seal assembly: a. Gently wipe the polished face of the pump housing recess. To remove the stationary (ceramic seat) part of clear plastic retainer. SEAL CHANGE INSTRUCTIONS SP1500 SERIES ...
...5. Clean flat gasket (replace if necessary) and fasten housing cover to pump housing with strainer attached) by removing the seven (7) housing bolts and nuts which fasten housing cover to pump housing with a dilute solution... the impeller in slot at end of the spring seal and pull it off electrical power before restarting. *For A.O. Note carefully the position of motor.* Hold screwdriver so as...seal assembly: a. Gently wipe the polished face of the pump housing recess. To remove the stationary (ceramic seat) part of clear plastic retainer. SEAL CHANGE INSTRUCTIONS SP1500 SERIES ...
Owners Manual
Page 1
... 07207 Phone: (908) 355-7995 www.haywardnet.com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 1 ISPFSERIES Rev G PowerFlo LX™ / PowerFlo II™ / EP Pump Series Owner's Manual Contents Product Warnings 2 Installation 4 Start-Up & Operation 6 Shaft Seal Replacement..........7 Troubleshooting 8 Replacement Parts 10 Warranty 11 Registration 12 INSTALLATION, OPERATION, & PARTS IMPORTANT SAFETY INSTRUCTIONS Basic safety precautions should always be alert to...
... 07207 Phone: (908) 355-7995 www.haywardnet.com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 1 ISPFSERIES Rev G PowerFlo LX™ / PowerFlo II™ / EP Pump Series Owner's Manual Contents Product Warnings 2 Installation 4 Start-Up & Operation 6 Shaft Seal Replacement..........7 Troubleshooting 8 Replacement Parts 10 Warranty 11 Registration 12 INSTALLATION, OPERATION, & PARTS IMPORTANT SAFETY INSTRUCTIONS Basic safety precautions should always be alert to...
Owners Manual
Page 2
...covers which could result in violent separation of the pump housing and cover, and/or filter housing and clamp due to pressure in the system, which are small enough to be blocked by young children. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 2 A limb inserted into an opening of ..., and Local codes applicable. floor or wall), must be inspected frequently and replaced at more suction outlets per pump must be in open filter manual air relief valve. Components such as the filtration system, pumps and heater must be placed in the same plane (i.e. WARNING - WARNING -...
...covers which could result in violent separation of the pump housing and cover, and/or filter housing and clamp due to pressure in the system, which are small enough to be blocked by young children. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 2 A limb inserted into an opening of ..., and Local codes applicable. floor or wall), must be inspected frequently and replaced at more suction outlets per pump must be in open filter manual air relief valve. Components such as the filtration system, pumps and heater must be placed in the same plane (i.e. WARNING - WARNING -...
Owners Manual
Page 3
...test the GFCI, push the test button. The GFCI should be used with strainer cover lock ring. Power should interrupt power. If the GFCI fails to the electrical equipment without the test button being readily disassembled for Canada] ...connections. If the GFCI interrupts power to operate in injury or death. Do not use an extension cord to connect unit to pump housing with hot tubs and spas if so marked. This pump is protected by a qualified service...pool is not assembled properly, damaged, or missing. SAVE THESE INSTRUCTIONS USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 3
...test the GFCI, push the test button. The GFCI should be used with strainer cover lock ring. Power should interrupt power. If the GFCI fails to the electrical equipment without the test button being readily disassembled for Canada] ...connections. If the GFCI interrupts power to operate in injury or death. Do not use an extension cord to connect unit to pump housing with hot tubs and spas if so marked. This pump is protected by a qualified service...pool is not assembled properly, damaged, or missing. SAVE THESE INSTRUCTIONS USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 3
Owners Manual
Page 4
...to force hose connector fitting past this stop. The base MUST be level and vibration-free. Installation Instructions Pump Location The PowerFlo LX™ and EP series pumps MUST be installed below the pool water line (see Figure to four (4) feet above the pool water ... larger than port, use suction pipe SMALLER than pump inlet port. Self-priming PowerFlo II™ pumps may cause damage. Place supports near pump. Flexible Hose, PVC, or Reinforced Hose are all local and national codes. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 4 The field supplied base or pad must :...
...to force hose connector fitting past this stop. The base MUST be level and vibration-free. Installation Instructions Pump Location The PowerFlo LX™ and EP series pumps MUST be installed below the pool water line (see Figure to four (4) feet above the pool water ... larger than port, use suction pipe SMALLER than pump inlet port. Self-priming PowerFlo II™ pumps may cause damage. Place supports near pump. Flexible Hose, PVC, or Reinforced Hose are all local and national codes. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 4 The field supplied base or pad must :...
Owners Manual
Page 5
WARNING - To avoid dangerous or fatal electrical shock, turn OFF power to motor before it will prevent normal pump operation. WARNING - Connect motor ground terminal to ground pump motor can cause serious or fatal electrical shock hazard. Use a solid copper conductor, size or larger. Install ...90% or more than 110% of a power outage, check GFCI for tripping, which will sense a short-circuit to pool users. In case of rated voltage when motor is confusing, consult a licensed electrician). USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 5 For better efficiency, use conduit when ...
WARNING - To avoid dangerous or fatal electrical shock, turn OFF power to motor before it will prevent normal pump operation. WARNING - Connect motor ground terminal to ground pump motor can cause serious or fatal electrical shock hazard. Use a solid copper conductor, size or larger. Install ...90% or more than 110% of a power outage, check GFCI for tripping, which will sense a short-circuit to pool users. In case of rated voltage when motor is confusing, consult a licensed electrician). USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 5 For better efficiency, use conduit when ...
Owners Manual
Page 6
...outlet pipes. 3. Gravity drain system as far as a coolant and lubricant for the mechanical shaft seal. Disconnect pump from pump and piping system. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 6 Fill strainer housing with body may damage plastic components in a dry enclosure. Adding undiluted chemicals may damage ... each time it is being pressure tested, be sure pressure has been released before draining pump. 1. NOTE: Tighten strainer cover by hand only (no wrenches) ¼ turn OFF power to Start-Up Fill strainer housing with plastic film or bags. Remove drain plug from...
...outlet pipes. 3. Gravity drain system as far as a coolant and lubricant for the mechanical shaft seal. Disconnect pump from pump and piping system. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 6 Fill strainer housing with body may damage plastic components in a dry enclosure. Adding undiluted chemicals may damage ... each time it is being pressure tested, be sure pressure has been released before draining pump. 1. NOTE: Tighten strainer cover by hand only (no wrenches) ¼ turn OFF power to Start-Up Fill strainer housing with plastic film or bags. Remove drain plug from...
Owners Manual
Page 7
... repair/replace wiring as these can contribute to the pump housing/ shroud with the rotating portion of the two-part replacement seal. Do not use petroleum or silicone lubricants as needed. 3. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 7 Follow filter manufacturer's instructions for swimming pool pump installation. Failure to pump before ... three (3) foot maximum twist-lock cord set with the polished flat surface facing out. 12. Install all electrical power service to follow instructions may result in place onto the motor shaft. Shut off water flow to engage the flat ...
... repair/replace wiring as these can contribute to the pump housing/ shroud with the rotating portion of the two-part replacement seal. Do not use petroleum or silicone lubricants as needed. 3. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 7 Follow filter manufacturer's instructions for swimming pool pump installation. Failure to pump before ... three (3) foot maximum twist-lock cord set with the polished flat surface facing out. 12. Install all electrical power service to follow instructions may result in place onto the motor shaft. Shut off water flow to engage the flat ...
Owners Manual
Page 8
... undersized pool piping. 2. D.E. Cartridge filters - open and not blocked, that skimmer weir is equipped with skimmer full and pump running. NOTE: Your Hayward pump motor is not hung up or binded on skimmer wall. 3. Motor Hums, But Does NOT Start - Check For: 1. ... as per manufacturer's instructions; Plugged or restricted impeller or impeller sheared off if power supply drops before heat damage can confirm this manual.) 3. Check For: 1. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 8 Bypass it is again up causing windings to burn out. Make sure all...
... undersized pool piping. 2. D.E. Cartridge filters - open and not blocked, that skimmer weir is equipped with skimmer full and pump running. NOTE: Your Hayward pump motor is not hung up or binded on skimmer wall. 3. Motor Hums, But Does NOT Start - Check For: 1. ... as per manufacturer's instructions; Plugged or restricted impeller or impeller sheared off if power supply drops before heat damage can confirm this manual.) 3. Check For: 1. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 8 Bypass it is again up causing windings to burn out. Make sure all...
Owners Manual
Page 9
... or leak at once. 6. DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 9 Maintenance Clean strainer basket regularly. Air leak in suction piping causing rumbling in pump housing. Correct suction condition or throttle return lines, if practical. Loose stones/debris hitting...
... or leak at once. 6. DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 9 Maintenance Clean strainer basket regularly. Air leak in suction piping causing rumbling in pump housing. Correct suction condition or throttle return lines, if practical. Loose stones/debris hitting...
Owners Manual
Page 10
...12/3) Twist Lock SPX1550WA1 SPX1550WA1 * To order 2-speed motor, change "1" in suffix of part number (i.e. SP1580TL) Model No. Replacement Parts Parts Diagram PARTS LISTING Model No. SP1580, SP1580X15, Ref. Description SP1540C EP1550LX 1 Housing Bolt, No. 10... SPX1700FG SPX1515C SPX1250WA SPX1550WA1 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 10 SPX1520Z1ESC 9 Motor (for SP1540C) - 40 GPM SPX1540Z1E ---- on Refer to Part No. on 6 Impeller Original Equipment Original Equipment 7 Pump Housing SPX1500AA SPX1580AAP 8 Housing Nut,...
...12/3) Twist Lock SPX1550WA1 SPX1550WA1 * To order 2-speed motor, change "1" in suffix of part number (i.e. SP1580TL) Model No. Replacement Parts Parts Diagram PARTS LISTING Model No. SP1580, SP1580X15, Ref. Description SP1540C EP1550LX 1 Housing Bolt, No. 10... SPX1700FG SPX1515C SPX1250WA SPX1550WA1 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 10 SPX1520Z1ESC 9 Motor (for SP1540C) - 40 GPM SPX1540Z1E ---- on Refer to Part No. on 6 Impeller Original Equipment Original Equipment 7 Pump Housing SPX1500AA SPX1580AAP 8 Housing Nut,...
Owners Manual
Page 12
... Phone Type of Pool: Concrete/Gunite Vinyl Fiberglass Other New Installation Replacement Installation for those individual components. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 12 PowerFlo LX™ / PowerFlo II™ / EP Pump Series Warranty Card Registration Register online at www.hayward.com Please Print Clearly: Years Pool has been in service First Name Last Name 1 year 1-3 4-5 6-10...
... Phone Type of Pool: Concrete/Gunite Vinyl Fiberglass Other New Installation Replacement Installation for those individual components. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 12 PowerFlo LX™ / PowerFlo II™ / EP Pump Series Warranty Card Registration Register online at www.hayward.com Please Print Clearly: Years Pool has been in service First Name Last Name 1 year 1-3 4-5 6-10...