Configuration Menu Locked Configuration Menu press > to next item Time: Th 1:27PM + change or > skip Set Day and Time Thursday 1:27p Speed Selection rpm MAX allowed speed 3450 (600-3450rpm) MIN allowed speed 600 (600-3450rpm) Set max-speed Prime Period: Auto Sense Remote Control Mode Standalone/Hayward Set COMM Bus Address Pool Filter to adjust, > go to enter Use + / -
EcoStar C Digital Control Interface Manual IS3400VSPC - Page 1

... to set selected password character Move to next password character Note: When password protection is not confirmed correctly, then the user will respond to any of time from the pool control. Password Protection Disabled Buttons Used + Comments Use to enable or disable password protection Move to EcoStar Pump Owner's Guide (IS3400VSP) for all commands being controlled by a Hayward...
Technical Guide - Page 12

... not compatible) v2.80 or higher 2 3 Figure 22 4 Note: Wire from 4 on 7 EcoStar is data connected to a Hayward/Goldline control, voltage needs to point. Installation-Hayward/Goldline Controls (Compatible software shown below) 1. Wire 7 on the pump to 2 on the controller, 8 on the pump to 3 on the controller and 1 on the pump to 4 to 1 on Remote display to the...
Technical Guide - Page 18

Press the button (fig 32) to the pump, the pump model will have default setting of 1750 RPM (50%), 7 days a week from 12:00 am - 11:45 pm. 2. When power is changed or set as shown to unlock and enter the Configuration menu (fig 33). Timer 1 will display, then the following screens (fig 31 & 32). Fig...
Technical Guide - Page 19

Press the button to enter the Configuration Menu (fig 34). 5. Programming-Configuration 4. Fig 34 Fig 35 Page 17 On the next screen you will tell you how to use the & buttons to adjust, and the to go to the next item (fig 35). On the next screen it will be asked to press the button to continue.
Technical Guide - Page 23

... controls including third party models) (fig 43 & 44). Use the & buttons to continue. 12. You will now see the max-speed Prime period. Press & buttons for Auto Sense (3000 RPM), or a 3 min (max set speed) prime period (fig 42).This function only works in Standalone and Relay Control modes. Press the button to continue . Programming-Configuration...
Technical Guide - Page 26

... time clock perimeters. If yes, press and confirm on setting password protection. If no, press the button to continue. Otherwise continue with this point you have an HCP3400VSP or HCP3400VSPVR commercial EcoStar please refer to page 39 for directions on the next screen. Programming-Configuration If you will be the next to program. At...
Technical Guide - Page 27

... bus address needs to be changed as relays on control connected pumps. Press the button until you see the Timers Menu (fig 51). Programming-Timers Stand alone/Hayward Stand alone: Both times and speeds need to be set as needed. . Relay Control Only requires that speed be set in Configuration. 1. Press the button to run the pump if the...
Technical Guide - Page 42

... on the pump, or by resetting all parameters in the Configuration menu. Models HCP3400VSP and HCP3400VSPVR Page 40 Resume configuration on page 24 System Locked Password: 0____ Figure 80 Figure 81 Figure 82 Note: If the password has been changed it may be asked to confirm the password. When you press any key other than the Stop...
Technical Guide - Page 44

... (page 36). Clear all debris from lead to ground. Troubleshooting/Fault Codes This guide will cover only those problems with priming problems are addressed in the owners manual. PFC Circuit Hi Drive Error! Check incoming line voltage (page 4) and verify that the internal components of 230 VAC. Code/Fault Indications Drive Error! Check fan and shroud for issues. All other pump...
Technical Guide - Page 45

... (page 4) and verify that it is correct and error still occurs, replace drive. Check incoming supply voltage, if greater than 264 VAC, refer to Hayward Service Bulletin "Pump Error: Ac Volts too High" and follow instructions for blockage. Check fan and shroud for registry change , replace drive. If error still occurs, replace drive. Indicates that the heatsink on the bottom of...
Technical Guide - Page 46

... and drive. If any of these readings are connected correctly (page 10). Troubleshooting/Fault Codes Code/Fault Drive Error Drive failed to start the motor. If no continuity. If error still exists remove all (0) check connection between terminal 1 with EcoStar and terminal 4 with Hayward/Goldline Control (page 10). If pump is displayed. There should be sure motor shaft...
Technical Guide - Page 48

... Clemmons Tech Service for isolator. It travels on the comm. If the values are correct, replace the drive. Control reads "Pool bridge comm" This indicates interference on the comm. This is connected to a GL/Hayward control. The breaker is tripping. Page 46 If not, replace motor. Check input wiring and breaker. Troubleshooting/Fault Codes Code/Fault Indications Warning...
Technical Guide - Page 49

... are on control display. Troubleshooting/Fault Codes Code/Fault Indications EcoStar is connected and configured to operate with the settings in the control (page 20) EcoStar reverts to Standalone mode even when properly connected to the GL/Hayward control. Check comm. Be sure EcoStar is configured for relay control (page 10) . No error on the EcoStar comm. EcoStar is set to...
Technical Guide - Page 50

... Menu button is actually for relay control. The EcoStar is causing other equipment from the control are connected in the EcoStar does not work . Remove wires and connect to the pump, the EcoStar interface reads "Remote Stop Engaged". If problem persists, purchase (2) model XPF 20A 3-wire noise filters through X-10 website. This is connected and operating via the GL/Hayward...

Hayward EcoStar C Reviews

Do you have an experience with the Hayward EcoStar C that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Hayward yet.

Popular Hayward EcoStar C Search Terms

The following terms are frequently used to search for Hayward EcoStar C support:

Ask a New Question
Use the box below to post a new question about Hayward EcoStar C.
Manuals / Documents
Download any of our Hayward EcoStar C manuals for free!

We have the following 3 documents available for the Hayward EcoStar C:
  • Technical Guide
  • EcoStar® Manual
  • EcoStar C Digital Control Interface Manual IS3400VSPC

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward EcoStar C manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward EcoStar C user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.