CAT 2000
Page 1
CAT 2000 AUTOMATED CONTROLLER OWNER'S MANUAL INSTALLATION OPERATION MAINTENANCE SPECIFICATIONS
CAT 2000 AUTOMATED CONTROLLER OWNER'S MANUAL INSTALLATION OPERATION MAINTENANCE SPECIFICATIONS
CAT 2000
Page 2
... to eliminate pressure from the CAT 2000 line of chemical automation. Physically, installation of the controller. Any swimming pool contractor or maintenance engineer should provide you have selected from the system. ALL RIGHTS RESERVED All CAT controllers incorporate state of the art .... As is the case when installing any questions pertaining to perform the installation. CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC. Remember that your new CAT controller is familiar with Health Department operating standards, chemical cost savings, and many years of reliable operation....
... to eliminate pressure from the CAT 2000 line of chemical automation. Physically, installation of the controller. Any swimming pool contractor or maintenance engineer should provide you have selected from the system. ALL RIGHTS RESERVED All CAT controllers incorporate state of the art .... As is the case when installing any questions pertaining to perform the installation. CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC. Remember that your new CAT controller is familiar with Health Department operating standards, chemical cost savings, and many years of reliable operation....
CAT 2000
Page 4
... pH and sanitizer activity, constantly adjusting the feeding of chemical levels twenty-four hours a day, compliance with the CAT 2000 controller. MANUAL -VS- SECTION 1. CAT AUTOMATED CONTROL CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC. CHEMICAL AUTOMATION WITH THE CAT 2000 A pool operator typically checks and adjusts pool or spa water chemistry hourly at best. ALL RIGHTS RESERVED The results...
... pH and sanitizer activity, constantly adjusting the feeding of chemical levels twenty-four hours a day, compliance with the CAT 2000 controller. MANUAL -VS- SECTION 1. CAT AUTOMATED CONTROL CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC. CHEMICAL AUTOMATION WITH THE CAT 2000 A pool operator typically checks and adjusts pool or spa water chemistry hourly at best. ALL RIGHTS RESERVED The results...
CAT 2000
Page 5
... The Professional-Series ORP Sensor samples water from the filtration system and sends signals to maintain ORP at 650 millivolts. The CAT 2000 controller unit also features an internal micro-computer for unsurpassed accuracy, adaptability, and ease of equipment, and damage to manually feed or... sanitizer activity (chlorine, bromine, ozone, etc.) and bacteriological water quality rather than an expression of chemical residual levels. The CAT 2000 controller unit scans and interprets the signals from the pH and ORP probes, displays water quality readings in digital format, and activates ...
... The Professional-Series ORP Sensor samples water from the filtration system and sends signals to maintain ORP at 650 millivolts. The CAT 2000 controller unit also features an internal micro-computer for unsurpassed accuracy, adaptability, and ease of equipment, and damage to manually feed or... sanitizer activity (chlorine, bromine, ozone, etc.) and bacteriological water quality rather than an expression of chemical residual levels. The CAT 2000 controller unit scans and interprets the signals from the pH and ORP probes, displays water quality readings in digital format, and activates ...
CAT 2000
Page 6
... protected by a ground-fault circuit interrupter (GFI). Connect controller only to installation. 2. CAT Controllers recommends installation to damage by a licensed electrician. 3. WARNING - Never operate a controller without functional flow protection. 5. Always read and become familiar...receptacle. Always mount controller in a safe area not subject to a dedicated GFI circuit breaker performed by moving objects. Caution: The automatic controller should be replaced immediately to the controller. 6. WARNING - WARNING - CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC. ...
... protected by a ground-fault circuit interrupter (GFI). Connect controller only to installation. 2. CAT Controllers recommends installation to damage by a licensed electrician. 3. WARNING - Never operate a controller without functional flow protection. 5. Always read and become familiar...receptacle. Always mount controller in a safe area not subject to a dedicated GFI circuit breaker performed by moving objects. Caution: The automatic controller should be replaced immediately to the controller. 6. WARNING - WARNING - CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC. ...
CAT 2000
Page 7
Do not use a razor or sharp instrument to Connect Sensors) (2) Sensor Storage Containers (1) CAT 2000 Owner's Manual The CAT 2000 Pro-Pack includes the following additional items: (1) PVC Backboard with Mounting Holes and Stainless Hardware (1) Machined Acrylic Flow Cell assembled with..., please confirm that items listed above have been included. Enclosed in the packaging you should find all of the following: (1) CAT 2000 Water Chemistry Controller (1) Professional Series pH Sensor with 24" Cable and BNC Connector (1) Professional Series ORP Sensor with 24" Cable and BNC Connector...
Do not use a razor or sharp instrument to Connect Sensors) (2) Sensor Storage Containers (1) CAT 2000 Owner's Manual The CAT 2000 Pro-Pack includes the following additional items: (1) PVC Backboard with Mounting Holes and Stainless Hardware (1) Machined Acrylic Flow Cell assembled with..., please confirm that items listed above have been included. Enclosed in the packaging you should find all of the following: (1) CAT 2000 Water Chemistry Controller (1) Professional Series pH Sensor with 24" Cable and BNC Connector (1) Professional Series ORP Sensor with 24" Cable and BNC Connector...
CAT 2000
Page 8
...a location just down-stream of flex tubing and insert into flow cell. CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC. INSTALLATION PROCEDURES The key to a successful flow cell installation is required to ...pressure from corrosive materials and physical hazards. 3. Located a minimum of 30'. D. Securely mount Controller or PVC Backboard on vertical wall. 4. Install a tubing connector, and run flex tubing to.... 6. ALL RIGHTS RESERVED A pressure differential is in the plumbing. We recommend using a CAT Flowcell and fittings to pool or spa operator. Drill and tap a 1/4" NPT port at...
...a location just down-stream of flex tubing and insert into flow cell. CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC. INSTALLATION PROCEDURES The key to a successful flow cell installation is required to ...pressure from corrosive materials and physical hazards. 3. Located a minimum of 30'. D. Securely mount Controller or PVC Backboard on vertical wall. 4. Install a tubing connector, and run flex tubing to.... 6. ALL RIGHTS RESERVED A pressure differential is in the plumbing. We recommend using a CAT Flowcell and fittings to pool or spa operator. Drill and tap a 1/4" NPT port at...
CAT 2000
Page 9
... Flow ALL CHEMICALS MUST BE INJECTED DOWN STREAM FROM HEATER & FLOW CELL Pressure Differential Connect chemical feeders to the controller unit as labeled. 12. CAT 2000 INSTALLATION DIAGRAM WITH FLOWCELL pH Sensor CAT 2000 ORP Sensor CAT 2000 CONTROLLER Chemical Pump Influent (to Return Line) Main Drain and Skimmer SUCTION LINE Flow Sample Stream Effluent (to be used...
... Flow ALL CHEMICALS MUST BE INJECTED DOWN STREAM FROM HEATER & FLOW CELL Pressure Differential Connect chemical feeders to the controller unit as labeled. 12. CAT 2000 INSTALLATION DIAGRAM WITH FLOWCELL pH Sensor CAT 2000 ORP Sensor CAT 2000 CONTROLLER Chemical Pump Influent (to Return Line) Main Drain and Skimmer SUCTION LINE Flow Sample Stream Effluent (to be used...
CAT 2000
Page 10
... Select a convenient mounting location for a typical bypass diagram. 1. Facilitates unobstructed bypass line plumbing. Securely mount the CAT 2000 controller on bypass inlet and effluent immediately adjacent to pool or spa operator. Install flow meter (optional) immediately downstream from...vertical wall. 4. SECTION 6. CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC. Located a minimum of a CAT Flowcell and Rotary Flow Sensor for plumbing with flexible tubing and Tru-seal connectors. The CAT Flowcell provides a controlled flow to accommodate ½" NPT Professional Series pH...
... Select a convenient mounting location for a typical bypass diagram. 1. Facilitates unobstructed bypass line plumbing. Securely mount the CAT 2000 controller on bypass inlet and effluent immediately adjacent to pool or spa operator. Install flow meter (optional) immediately downstream from...vertical wall. 4. SECTION 6. CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC. Located a minimum of a CAT Flowcell and Rotary Flow Sensor for plumbing with flexible tubing and Tru-seal connectors. The CAT Flowcell provides a controlled flow to accommodate ½" NPT Professional Series pH...
CAT 2000
Page 11
...;" tee fittings. Label and support all new piping. Connect chemical feeders to the controller unit as labeled. 16. CAT 2000 INSTALLATION DIAGRAM WITH BYPASS LINE CAT 2000 CAT 2000 CONTROLLER Chemical Pump pH Sensor Sensor Adaptor ORP Sensor Sensor Adaptor Chemical Pump CAT CO2 or pH Control Solenoid Flow Cell / Flow Sensor Bypass Line (Plumbed On-Site) Flow Flow Flow...
...;" tee fittings. Label and support all new piping. Connect chemical feeders to the controller unit as labeled. 16. CAT 2000 INSTALLATION DIAGRAM WITH BYPASS LINE CAT 2000 CAT 2000 CONTROLLER Chemical Pump pH Sensor Sensor Adaptor ORP Sensor Sensor Adaptor Chemical Pump CAT CO2 or pH Control Solenoid Flow Cell / Flow Sensor Bypass Line (Plumbed On-Site) Flow Flow Flow...
CAT 2000
Page 12
...that your local or State Health Department. All CAT water quality controllers maintain sanitizer levels (chlorine, bromine, ozone, etc.) based on and setting up the CAT 2000. CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC. CAT strongly recommends establishing desired pH, sanitizer residual, ... 400 The above table indicates generally accepted guidelines. Always maintain water chemistry according to standards set by your new controller has been physically installed, water chemistry should be changed periodically as pH, cyanuric acid concentration and total dissolved solids...
...that your local or State Health Department. All CAT water quality controllers maintain sanitizer levels (chlorine, bromine, ozone, etc.) based on and setting up the CAT 2000. CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC. CAT strongly recommends establishing desired pH, sanitizer residual, ... 400 The above table indicates generally accepted guidelines. Always maintain water chemistry according to standards set by your new controller has been physically installed, water chemistry should be changed periodically as pH, cyanuric acid concentration and total dissolved solids...
CAT 2000
Page 13
...select A for acid feed or B for base feed. Press the Enter key to set the CAT 2000 to normal operating mode. To match manual water testing results or compensate for controller unit button designations. As the unit powers on, the digital pH readout will automatically return to operate... maintain pH and sanitizer levels. To switch the controller between acid feed and base feed modes, perform the following steps. 1. Please refer to enter advanced setup mode. 2. Selecting Acid or Base Feed The CAT 2000 is preset from the CAT 2000 are ready to set your manual pH test reading...
...select A for acid feed or B for base feed. Press the Enter key to set the CAT 2000 to normal operating mode. To match manual water testing results or compensate for controller unit button designations. As the unit powers on, the digital pH readout will automatically return to operate... maintain pH and sanitizer levels. To switch the controller between acid feed and base feed modes, perform the following steps. 1. Please refer to enter advanced setup mode. 2. Selecting Acid or Base Feed The CAT 2000 is preset from the CAT 2000 are ready to set your manual pH test reading...
CAT 2000
Page 14
...: 1. ALL RIGHTS RESERVED The ORP setpoint should be changed as needed to maintain. 2. Changing the ORP Setpoint The CAT 2000 is illuminated. Changing the pH Setpoint The CAT 2000 is illuminated. 2. To set pH control at 7.5. Press the pH Setpoint Adjustment Button (#4) until the green "MANUAL" LED is preset from the factory to maintain... Department standards. Press the arrow-shaped ORP Channel Increase Button (#6) or ORP Channel Decrease Button (#7) until the digital display matches your desired pH control level. 3. CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC.
...: 1. ALL RIGHTS RESERVED The ORP setpoint should be changed as needed to maintain. 2. Changing the ORP Setpoint The CAT 2000 is illuminated. Changing the pH Setpoint The CAT 2000 is illuminated. 2. To set pH control at 7.5. Press the pH Setpoint Adjustment Button (#4) until the green "MANUAL" LED is preset from the factory to maintain... Department standards. Press the arrow-shaped ORP Channel Increase Button (#6) or ORP Channel Decrease Button (#7) until the digital display matches your desired pH control level. 3. CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC.
CAT 2000
Page 15
...CAT 2000 features an advanced proportional feed algorithm which constantly analyzes demand for 30 minutes, and then automatically revert to "Auto" to chemical demand. So that the user may have time to enter selections, the chemical feeding cycle will not be interrupted for approximately ten seconds. Automatically Controlling... for approximately ten seconds. The chemical feeder will not be disabled for approximately ten seconds. Automatically Controlling ORP Feed For automated control of the pH chemical feeder press the pH Channel Mode Selection Button (#5) until the red "OFF...
...CAT 2000 features an advanced proportional feed algorithm which constantly analyzes demand for 30 minutes, and then automatically revert to "Auto" to chemical demand. So that the user may have time to enter selections, the chemical feeding cycle will not be interrupted for approximately ten seconds. Automatically Controlling... for approximately ten seconds. The chemical feeder will not be disabled for approximately ten seconds. Automatically Controlling ORP Feed For automated control of the pH chemical feeder press the pH Channel Mode Selection Button (#5) until the red "OFF...
CAT 2000
Page 16
CAT 2000 SWITCH AND KEYPAD FUNCTIONS BUTTON DESIGNATION DESCRIPTION POWER Controller Unit Power Switch 1 Hidden Button (Located Behind "pH" Text) 2 pH Channel Increase Button 3 pH Channel Decrease Button 4 pH Channel ... Channel Mode Selection Button 6 ORP Channel Increase Button 7 ORP Channel Decrease Button 8 ORP Channel Setpoint Adjustment Button 9 ORP Channel Mode Selection Button CAT 2000 pH/ORP AUTOMATED CONTROLLER FEED p1H ALARM 2 3 SETPOINT ADJUSTMENT 4 SET CALIBRATE ORP FEED ALARM 6 7 SETPOINT ADJUSTMENT 8 SET pH FEED MODE 5 AUTO OFF MANUAL ...
CAT 2000 SWITCH AND KEYPAD FUNCTIONS BUTTON DESIGNATION DESCRIPTION POWER Controller Unit Power Switch 1 Hidden Button (Located Behind "pH" Text) 2 pH Channel Increase Button 3 pH Channel Decrease Button 4 pH Channel ... Channel Mode Selection Button 6 ORP Channel Increase Button 7 ORP Channel Decrease Button 8 ORP Channel Setpoint Adjustment Button 9 ORP Channel Mode Selection Button CAT 2000 pH/ORP AUTOMATED CONTROLLER FEED p1H ALARM 2 3 SETPOINT ADJUSTMENT 4 SET CALIBRATE ORP FEED ALARM 6 7 SETPOINT ADJUSTMENT 8 SET pH FEED MODE 5 AUTO OFF MANUAL ...
CAT 2000
Page 17
Advanced (Dealer) Setup Options Beginning with the 2008 model year, the CAT 2000 controller incorporates an advanced programming menu and enhanced features. Press the Up (#6) and Down (#7) arrow buttons to make a selection. Press the Enter Button (#8) to scroll through ... power on the LED displays, in addition to enter advanced setup mode. 2. Enhanced No-Flow Alarm The no-flow alarm displays the prompt on , the controller displays the pH feed mode and firmware version number. Entering Advanced Setup Mode Find the Hidden Button (#1) located behind the large pH text over the...
Advanced (Dealer) Setup Options Beginning with the 2008 model year, the CAT 2000 controller incorporates an advanced programming menu and enhanced features. Press the Up (#6) and Down (#7) arrow buttons to make a selection. Press the Enter Button (#8) to scroll through ... power on the LED displays, in addition to enter advanced setup mode. 2. Enhanced No-Flow Alarm The no-flow alarm displays the prompt on , the controller displays the pH feed mode and firmware version number. Entering Advanced Setup Mode Find the Hidden Button (#1) located behind the large pH text over the...
CAT 2000
Page 18
... feed output is any value outside this range. The pH Priority feature is activated based on . The pH feed output is enabled. CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC. On On (Default). Selects either fixed setpoint or proportional control. pH Feed Mode (Acid or Base Feed) P.Fd pH Feed.
... feed output is any value outside this range. The pH Priority feature is activated based on . The pH feed output is enabled. CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC. On On (Default). Selects either fixed setpoint or proportional control. pH Feed Mode (Acid or Base Feed) P.Fd pH Feed.
CAT 2000
Page 19
... returns to within the non-alarm range. 6.8 Use the UP and DOWN buttons to place the pH channel in which must be reset if the controller is indicated. default pH Low Alarm Limit P.AL pH Alarm Limit Low. The value must be on continuously for the pH channel. pH Overfeed Timer...
... returns to within the non-alarm range. 6.8 Use the UP and DOWN buttons to place the pH channel in which must be reset if the controller is indicated. default pH Low Alarm Limit P.AL pH Alarm Limit Low. The value must be on continuously for the pH channel. pH Overfeed Timer...
CAT 2000
Page 20
... be greater than or equal to the ORP setpoint, the ORP output feed is turned off , manual or automatic feed mode. CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC. OFF Off. When the measured ORP value is less than the pH alarm low value. After the ORP feed output has been ... the alarm. pH Alarm High Limit P.AH pH Alarm Limit High. ORP Proportional Feed O.PF ORP Proportional Feed. Selects either fixed setpoint or proportional control. The ORP feed output is selected, the ORP feed output will reset the ORP overfeed alarm and restart the overfeed timer. This will remain activated...
... be greater than or equal to the ORP setpoint, the ORP output feed is turned off , manual or automatic feed mode. CONTENTS COPYRIGHT 2010 HAYWARD INDUSTRIES, INC. OFF Off. When the measured ORP value is less than the pH alarm low value. After the ORP feed output has been ... the alarm. pH Alarm High Limit P.AH pH Alarm Limit High. ORP Proportional Feed O.PF ORP Proportional Feed. Selects either fixed setpoint or proportional control. The ORP feed output is selected, the ORP feed output will reset the ORP overfeed alarm and restart the overfeed timer. This will remain activated...
CAT 2000
Page 21
... pH alarm high value. The alarm will be cleared and feed will be disabled. The default value is used to their default values. Returns all controller operating parameters to place the ORP channel in the manual feed state. Continued The ORP overfeed timer is disabled when the ORP Feed Mode button...
... pH alarm high value. The alarm will be cleared and feed will be disabled. The default value is used to their default values. Returns all controller operating parameters to place the ORP channel in the manual feed state. Continued The ORP overfeed timer is disabled when the ORP Feed Mode button...