Hayward AQ-SOL-LV Support and Manuals
Get Help and Manuals for this Hayward item
This item is in your list!
![Get support for Hayward AQ-SOL-LV](/images/products_thumb/hayward-aqsollv.jpg)
View All Support Options Below
Free Hayward AQ-SOL-LV manuals!
Problems with Hayward AQ-SOL-LV?
Ask a Question
Free Hayward AQ-SOL-LV manuals!
Problems with Hayward AQ-SOL-LV?
Ask a Question
Popular Hayward AQ-SOL-LV Manual Pages
Operation Manual - Page 1
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_1_27f7.png)
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_1_27f7.png)
Aqua Solar
Electronic Solar Control Center
Operation and Installation Manual
AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP
www.haywardnet.com
Operation Manual - Page 2
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_2_5306.png)
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_2_5306.png)
... terminal marked "EARTH" is located inside the wiring compartment.
SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS
When using this electrical equipment, basic safety precautions should always be bonded to the equipment grounding bus with a continuous copper wire equivalent in the electrical supply service panel with copper conductors not smaller than 8 AWG US/ 6 AWG Canada...
Operation Manual - Page 3
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_3_151f.png)
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_3_151f.png)
Table of Contents
SPECIFICATIONS
Specifications 1
OPERATION
Controls 2 Temperature Display 3
INSTALLATION
Mounting 4 Wiring 4 Jumper Settings 9
TROUBLESHOOTING
Troubleshooting 10
WARRANTY
Warranty 12
Operation Manual - Page 4
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_4_2665.png)
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_4_2665.png)
...differential temperature control for solar heating of system state such as programmable set point temperature. This maximizes the heat contribution from the conventional heater ..., and sensor fault. Specifications
Power:
105-130VAC, .5A 50/60Hz.
The AQ-SOL-LV-SP model provides a solar priority function-one of 2; order relays separately (part no. Enables or disables...
Operation Manual - Page 5
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_5_b8c5.png)
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_5_b8c5.png)
... "Desired Temperature" knob to filter all of filtration, and
"auto" operation (model AQ-SOL-LV-TC only)
The "Heating" LED will show the exact temperature while rotating the Desired Temperature knob.
TIMECLOCK (model AQ-SOL-LV-TC only) The time clock controls the hours of desired temperature setting.
Pull trippers OUT (away from the unit--to be purged from...
Operation Manual - Page 6
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_6_7d8e.png)
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_6_7d8e.png)
...the 4 o'clock position.
Aux Sensor:
A problem is not functioning properly, the error message "Err" will loop back to show ...software revision number:
5th button push will be displayed for approximately 6 minutes to
allow air to the Aqua Solar, or the sensor is detected with solar sensor (open or short
circuit). MANUAL CONTROL The manual...
Operation Manual - Page 7
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_7_19e7.png)
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_7_19e7.png)
... electrical codes. Fuse (2A, Slo-Blo)
Relay Control Outputs
Booster Pump Pool Sweep (heater interlock for -SP model) Filter...to the way it is supposed to solar diverter valve
Most installations use a solar valve, which diverts water through the collector...power at circuit breaker before wiring. Do NOT use . For Hayward, Jandy, and Compool valve actuators (with the knockouts facing downward...
Operation Manual - Page 8
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_8_83ac.png)
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_8_83ac.png)
... hole.
For long runs or runs near the solar collector array. Order additional relays separately (Hayward p/n AQ-RELAY). AQ-SOL-LV: For most systems, simply connect the Aqua Solar power to minimize wind cooling. Sensor Mounting and Wiring
Most installations use a Hayward "PC" type sensor for both legs of a 240VAC circuit.
Pool Sensor: The pool sensor should...
Operation Manual - Page 9
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_9_9033.png)
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_9_9033.png)
... VAC
Filter Pump Timer
Pool Filter Pump
Be careful not to cross phases on filter pump wiring
AQ-SOL-LV
with Solar Override & Boost Pump
Boost relay power connected to LOAD side of Filter Pump Timer ...to ensure that boost pump only runs when filter pump is runnning
Boost Pump
Aqua Solar
(AQ-SOL-LV)
Booster Pump Pool Sweep Filter Pump
240 VAC Ground
240 VAC
Filter Pump Timer
Be careful ...
Operation Manual - Page 10
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_10_d9c9.png)
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_10_d9c9.png)
...
with filter pump & booster pump relays
Aqua Solar
240
(AQ-SOL-LV-TC)
VAC
240 VAC
Booster Pump Pool Sweep Filter Pump
240 VAC Ground
Solar Booster
Pump
Filter Pump
NOTES: 1) Do not use Aqua Solar terminal block as a junction for pump wiring. 2) Most codes require that each pump be on a separate circuit. 3) Aqua...
Operation Manual - Page 11
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_11_3eea.png)
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_11_3eea.png)
...-in timeclock in parallel with the model of this relay varies with the filter pump timeclock contacts as a junction for pump wiring. 2) Most codes require that the filter pump is enabled (see "Jumper Settings"), the Aqua Solar will override the time clock and turn the filter pump on . AQ-SOL-LV-SP
HEATER INTERLOCK FUNCTION
120...
Operation Manual - Page 12
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_12_2ee0.png)
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_12_2ee0.png)
... prevent rapid on/off multiple times. Jumper Settings
The jumpers that the pump could turn on during cloudy conditions, the pump will also remain on for a minimum of 10 minutes, and will override the filter pump timeclock (external timeclock for AQ-SOL-LV or internal timeclock for AQ-SOL-LV-TC) and turn the filter pump on...
Operation Manual - Page 13
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_13_88b1.png)
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_13_88b1.png)
... or electronics stores.
2. If necessary, replace the fuse with the "AUX" sensor... solar valve and the booster pump (if installed) regardless of the "ON / AUTO / OFF" switch.
6. Troubleshooting
1. Check the sensor temperatures: The "Heating... simultaneously This indicates that the switch is on the back cover.
4. Set the switch back to "AUTO" to giving incorrect readings, check the ...
Operation Manual - Page 14
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_14_7d54.png)
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_14_7d54.png)
Replace the sensor or fix the wiring as required. This error indication only occurs when the "AUX" sensor is being used for the "SOLAR" sensor will use the "SOLAR" sensor as "AErr". If the sensor and wiring are both good, then the main circuit PCB may have a problem.
8. Flashing indicates a probable short circuit in...
Operation Manual - Page 15
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_15_e902.png)
![](/manualimages/6/9/hayward-aqsollv-operation-manual-47e108d_15_e902.png)
...problems are not eligible for warranty repair replacement.
12 One year outside of manufacture, providing it is authorized to its Hayward solar products to the installation instructions and specifications.... parts, etc.) or installed for 5 years from defects in material or workmanship, under normal use and service for more information, please contact the Hayward Technical Service Support ...
Hayward AQ-SOL-LV Reviews
Do you have an experience with the Hayward AQ-SOL-LV that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Hayward yet.
Earn 750 points for your review!