User Manual
Page 4
Operation Guide Operation panel Auto swing switch Auto swing OFF ON 3 Temp. Thermostat switch Mode selection switch 2 setting COOL 6 Mode selection OFF LO HI fan fan 9 1 Test run LO cool HI cool Wait 3 minutes before restarting.
Operation Guide Operation panel Auto swing switch Auto swing OFF ON 3 Temp. Thermostat switch Mode selection switch 2 setting COOL 6 Mode selection OFF LO HI fan fan 9 1 Test run LO cool HI cool Wait 3 minutes before restarting.
User Manual
Page 5
... fan" and "HI cool", "LO fan" and "LO cool". 3 Hint When mode selection switch is set to " ON ", vertical louver will swing from side to side, delivering gentle air thus making you feel very comfortable. When set to "LO cool", air-con will start speedy cooling, blowing out strong air. When set to "HI fan", fan motor runs at low speed , blowing out gentle air. Operation Guide Auto swing switch Auto swing OFF ON When the switch...
... fan" and "HI cool", "LO fan" and "LO cool". 3 Hint When mode selection switch is set to " ON ", vertical louver will swing from side to side, delivering gentle air thus making you feel very comfortable. When set to "LO cool", air-con will start speedy cooling, blowing out strong air. When set to "HI fan", fan motor runs at low speed , blowing out gentle air. Operation Guide Auto swing switch Auto swing OFF ON When the switch...
User Manual
Page 8
Change installation place: If air-con need to be spattered onto the condensation to raise efficiency of heat exchange. The drain hole on the bottom in the bottom tray be changed to make the condensate run out. In this method the efficiency of the air conditioner will be connected to use the exclusive power cord. Condensate runs out from the drain hole on the bottom of air conditioner will be clogged...
Change installation place: If air-con need to be spattered onto the condensation to raise efficiency of heat exchange. The drain hole on the bottom in the bottom tray be changed to make the condensate run out. In this method the efficiency of the air conditioner will be connected to use the exclusive power cord. Condensate runs out from the drain hole on the bottom of air conditioner will be clogged...
User Manual
Page 9
Keep away from air conditioner. Don't be exposed to bed. a little bit higher before going to cold air for a long time. After unit stops, don't restart it until 3 min. OK! enjoy a 3-min nap 7 Keep heat source away from me No entrance Set temp. Maintenance Avoid opening door and window unless necessary. Use curtain or blind Direct sunlight may reduce cooling effect, always use window curtain. have elapsed.
Keep away from air conditioner. Don't be exposed to bed. a little bit higher before going to cold air for a long time. After unit stops, don't restart it until 3 min. OK! enjoy a 3-min nap 7 Keep heat source away from me No entrance Set temp. Maintenance Avoid opening door and window unless necessary. Use curtain or blind Direct sunlight may reduce cooling effect, always use window curtain. have elapsed.
User Manual
Page 10
This will decrease cooling effect and cause abnormal operation. Go away! For longer and trouble-free operation of air inlet. Before operating mode selection switch, check if the air inlet or outlet have been blocked. Avoid places where flammable gas leaks. Baby has gone sleep had better adjust suitable temp. Leave enough space around air inlet and outlet for better circulation. Temperature should be set properly when...
This will decrease cooling effect and cause abnormal operation. Go away! For longer and trouble-free operation of air inlet. Before operating mode selection switch, check if the air inlet or outlet have been blocked. Avoid places where flammable gas leaks. Baby has gone sleep had better adjust suitable temp. Leave enough space around air inlet and outlet for better circulation. Temperature should be set properly when...
User Manual
Page 11
... Readjust power supply or replace fuse. Remove the obstacles. Trouble Shooting Phenomenon Doesn't work Check the unit Is plug firmly inserted? Is thermostat switch wrongly adjusted? Use curtain or blind. Is air filter clogged? Does fuse get burned? Readjust the thermostat. No cool air or poor cooling Is mode selection switch set to "Hi fan" or "Lo fan"? Clean it. Is there too much heat source in the room? Is direct sunlight in the room? Is door or window left open...
... Readjust power supply or replace fuse. Remove the obstacles. Trouble Shooting Phenomenon Doesn't work Check the unit Is plug firmly inserted? Is thermostat switch wrongly adjusted? Use curtain or blind. Is air filter clogged? Does fuse get burned? Readjust the thermostat. No cool air or poor cooling Is mode selection switch set to "Hi fan" or "Lo fan"? Clean it. Is there too much heat source in the room? Is direct sunlight in the room? Is door or window left open...
User Manual
Page 13
....3). Drain hose Fig.3 Drain elbow 11 Installation instruction The installation of air conditioner(only for reference) 1,Make the wall hole or window hole(see Fig.1) A B HW-09CV03 350 530 HW-12CV03 Iron bracket 2,Fix the prefabricated iron bracket to needed position (see Fig.4). Depth of the wall Fig.1 Condenser Rubber lid Fig.2 6,If you need to lead the condensed water to indicated position,pleae purchase a piece of plastic pipe with seal ring)into the drain hole...
....3). Drain hose Fig.3 Drain elbow 11 Installation instruction The installation of air conditioner(only for reference) 1,Make the wall hole or window hole(see Fig.1) A B HW-09CV03 350 530 HW-12CV03 Iron bracket 2,Fix the prefabricated iron bracket to needed position (see Fig.4). Depth of the wall Fig.1 Condenser Rubber lid Fig.2 6,If you need to lead the condensed water to indicated position,pleae purchase a piece of plastic pipe with seal ring)into the drain hole...
User Manual
Page 14
... 1. Installation instruction Wall 8,Fill any distance between the wall hole and the machine body with the local wiring standard. 12 Fig.4 Drain hose The machine is damaged, it must be easily reached. 4. If the supply cord is adaptive in line with flexible sponge rubber strip to prevent the entering of outer noise and the leaking of the coolness. 9,After installation of the conditioner , insert the power plug...
... 1. Installation instruction Wall 8,Fill any distance between the wall hole and the machine body with the local wiring standard. 12 Fig.4 Drain hose The machine is damaged, it must be easily reached. 4. If the supply cord is adaptive in line with flexible sponge rubber strip to prevent the entering of outer noise and the leaking of the coolness. 9,After installation of the conditioner , insert the power plug...
User Manual
Page 15
Wiring Diagram WIRING DIAGRAM 7363749 R BOATSWITCH SYNCHROMOTOR R M BL OPTIONAL SWITCH 1 2 4 3 LO FAN LO COOL HI COOL HI FAN OFF 0 LN BR BR Y/G BL BL Y/G POWER TERMINAL BLOCK R FAN MOTOR Y R B M OR FAN CAPACITOR BL C THERMOSTAT L COMP. R S M C R PROTECTOR COMP. HW-09CV03 2600 980 5.0 330 1.2 523X564X342 33.5 Yes HW-12CV03 3500 1300 6.3 380 1.5 523X564X342 39.5 Yes B CAPACITOR BL BL TERMINAL BLOCK R: RED OR:ORANGE B: BLACK Y:YELLOW BL: BLUE BR: BROWN Y/G:YELLOW/GREEN NOTE...
Wiring Diagram WIRING DIAGRAM 7363749 R BOATSWITCH SYNCHROMOTOR R M BL OPTIONAL SWITCH 1 2 4 3 LO FAN LO COOL HI COOL HI FAN OFF 0 LN BR BR Y/G BL BL Y/G POWER TERMINAL BLOCK R FAN MOTOR Y R B M OR FAN CAPACITOR BL C THERMOSTAT L COMP. R S M C R PROTECTOR COMP. HW-09CV03 2600 980 5.0 330 1.2 523X564X342 33.5 Yes HW-12CV03 3500 1300 6.3 380 1.5 523X564X342 39.5 Yes B CAPACITOR BL BL TERMINAL BLOCK R: RED OR:ORANGE B: BLACK Y:YELLOW BL: BLUE BR: BROWN Y/G:YELLOW/GREEN NOTE...