User Manual
Page 1
Accessory parts Number of articles 1 Remote controller 1 Optional parts for piping 2 R-03 dry battery 2 Mark A Parts name Non-adhesive tape B Adhesive tape 3 1 C Saddle(L.S) with screws Mounting plate D Connecting electric cable for the installation of indoor and outdoor units Accessory parts No. Installation Manual of Room Air Conditioner Read this manual. The distance between the indoor unit and the floor should be paid to the rising up of drain hose A more than 10cm C more than 10cm D E No...
Accessory parts Number of articles 1 Remote controller 1 Optional parts for piping 2 R-03 dry battery 2 Mark A Parts name Non-adhesive tape B Adhesive tape 3 1 C Saddle(L.S) with screws Mounting plate D Connecting electric cable for the installation of indoor and outdoor units Accessory parts No. Installation Manual of Room Air Conditioner Read this manual. The distance between the indoor unit and the floor should be paid to the rising up of drain hose A more than 10cm C more than 10cm D E No...
User Manual
Page 2
... outdoor unit (Unit:mm) HSU-09LEK03/(DB) HSU-12LEK03/(DB) HSU-18LEK13 HSU-108CH09 HSU-138CH09 HSU-12LEK13-M HSU-18HEK03 113.5 583 113.5 Floor fixing dimensions of the outdoor unit (Unit:mm) HSU-24LEK13 HSU-18LEK03/(DB) HSU-24HEK03 Selection of pipe To this unit, both liquid and gas pipes shall be fixed against the wall, then temporarily fasten the plate with one steel nail. 2. Use optional parts for the plate to outside the wall. Install piping hole cover...
... outdoor unit (Unit:mm) HSU-09LEK03/(DB) HSU-12LEK03/(DB) HSU-18LEK13 HSU-108CH09 HSU-138CH09 HSU-12LEK13-M HSU-18HEK03 113.5 583 113.5 Floor fixing dimensions of the outdoor unit (Unit:mm) HSU-24LEK13 HSU-18LEK03/(DB) HSU-24HEK03 Selection of pipe To this unit, both liquid and gas pipes shall be fixed against the wall, then temporarily fasten the plate with one steel nail. 2. Use optional parts for the plate to outside the wall. Install piping hole cover...
User Manual
Page 3
... number of indoor and outdoor units carefully. Pull the cable slightly to fasten the connected cable with the type of T. 25A/250V. 3. If the fuse of outdoor unit on PC board is not correct, proper operation can not be replaced by removing its service agent or a similar qualified person. A breaker should be incorporated into fixed wiring. Power cable: 3G1.0mm 1(N) 2(L) 34 Power cable: 3G1.0mm 3(C) Indoor unit Outdoor unit HSU-09LEK03/(DB) HSU...
... number of indoor and outdoor units carefully. Pull the cable slightly to fasten the connected cable with the type of T. 25A/250V. 3. If the fuse of outdoor unit on PC board is not correct, proper operation can not be replaced by removing its service agent or a similar qualified person. A breaker should be incorporated into fixed wiring. Power cable: 3G1.0mm 1(N) 2(L) 34 Power cable: 3G1.0mm 3(C) Indoor unit Outdoor unit HSU-09LEK03/(DB) HSU...
User Manual
Page 4
... to the following list. Spanner Torque wrench Be careful that matters, such as wastes of gas side first makes working easier. Half union Flare nut Forced fastening without careful centering may damage the threads and cause a leakage of the indoor unit and piping as figure. (Note: Only for 18K 22K 24K: A=20m 4 Outdoor unit A B Oil trap C Indoor unit CAUTION In...
... to the following list. Spanner Torque wrench Be careful that matters, such as wastes of gas side first makes working easier. Half union Flare nut Forced fastening without careful centering may damage the threads and cause a leakage of the indoor unit and piping as figure. (Note: Only for 18K 22K 24K: A=20m 4 Outdoor unit A B Oil trap C Indoor unit CAUTION In...