Accessory parts Number of articles 1 Remote controller 1 Optional parts for piping 2 R-03 dry battery 2 Mark A Parts name Non-adhesive tape B Adhesive tape 3 1 C Saddle(L.S) with screws Mounting plate D Connecting electric cable for the installation of indoor and outdoor units Accessory parts No. Necessary Tools for Installation 1.Driver 2.Hacksaw 3.Hole core drill 4.Spanner(17,19 and 26mm) 5.Torque wrench(17mm,22mm,26mm) 6.Pipe cutter 7.Flaring tool 8.Knife 9.Nipper 10.Gas leakage detector...
Accessory parts Number of articles 1 Remote controller 1 Optional parts for piping 2 R-03 dry battery 2 Mark A Parts name Non-adhesive tape B Adhesive tape 3 1 C Saddle(L.S) with screws Mounting plate D Connecting electric cable for the installation of indoor and outdoor units Accessory parts No. Necessary Tools for Installation 1.Driver 2.Hacksaw 3.Hole core drill 4.Spanner(17,19 and 26mm) 5.Torque wrench(17mm,22mm,26mm) 6.Pipe cutter 7.Flaring tool 8.Knife 9.Nipper 10.Gas leakage detector...
User Manual
Page 2
... the outdoor unit (Unit:mm) Selection of 60 mm in operation. Find the wall hole location A using a measuring tape B= 60mm B= 60mm A=145mm 30mm 30mm HSU-09CA2 HSU-12LEA13-F HSU-12CA2 HSU-12HEA03 HSU-12CB2 HSU-05LEA03 HSU-12LEN03 HSU-07LEA03 HSU-09LEN03 HSU-09HEA03 HSU-09LEA13-H HSU-09LEA13-F HSU-09LEA03 HSU-09LEA13-W HSU-12LEA13-M HSU-12LEA03 HSU-09LEB13-H HSU-12LEA13-W HSU-10LEA03-T A=145mm HSU-10LED03-T HSU-09HEC03 HSU-09LEA03-N HSU-12HEC03 2.Making a Hole on the neighboring pillars or lintels, a proper leveling for piping set or pipes covered...
... the outdoor unit (Unit:mm) Selection of 60 mm in operation. Find the wall hole location A using a measuring tape B= 60mm B= 60mm A=145mm 30mm 30mm HSU-09CA2 HSU-12LEA13-F HSU-12CA2 HSU-12HEA03 HSU-12CB2 HSU-05LEA03 HSU-12LEN03 HSU-07LEA03 HSU-09LEN03 HSU-09HEA03 HSU-09LEA13-H HSU-09LEA13-F HSU-09LEA03 HSU-09LEA13-W HSU-12LEA13-M HSU-12LEA03 HSU-09LEB13-H HSU-12LEA13-W HSU-10LEA03-T A=145mm HSU-10LED03-T HSU-09HEC03 HSU-09LEA03-N HSU-12HEC03 2.Making a Hole on the neighboring pillars or lintels, a proper leveling for piping set or pipes covered...
User Manual
Page 3
... supply cord is damaged, it must be incorporated into terminal block, then tighten the screws. After installation, the power plug should be replaced by removing its service agent or a similar qualified person.The type of connecting wire is broken please change it with the local wiring standard. 4. Indoor unit Connecting the indoor/outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by...
... supply cord is damaged, it must be incorporated into terminal block, then tighten the screws. After installation, the power plug should be replaced by removing its service agent or a similar qualified person.The type of connecting wire is broken please change it with the local wiring standard. 4. Indoor unit Connecting the indoor/outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by...
User Manual
Page 4
... Additional amount No need 40g 100g Additional amount No need 120g 300g 20m 900g Indoor unit A Outdoor unit B A B Indoor unit Outdoor unit Max.Elevation: for 5K 7K 9K 10K 12K 13K: B=5m for heat pump unit.) 3.Purging Method: Push the air out of the indoor unit and piping as followes: Tighten the caps on the valves with specified torque. shall not enter the pipe. 2.Attaching Drain-Elbow Pipe Diameter ( ) Fastening...
... Additional amount No need 40g 100g Additional amount No need 120g 300g 20m 900g Indoor unit A Outdoor unit B A B Indoor unit Outdoor unit Max.Elevation: for 5K 7K 9K 10K 12K 13K: B=5m for heat pump unit.) 3.Purging Method: Push the air out of the indoor unit and piping as followes: Tighten the caps on the valves with specified torque. shall not enter the pipe. 2.Attaching Drain-Elbow Pipe Diameter ( ) Fastening...