User Manual
Page 3
... between the indoor unit and the floor should be paid to this manual. Accessory parts Number of articles 1 Remote controller 1 Optional parts for piping 2 R-03 dry battery 2 Mark A Parts name Non-adhesive tape B Adhesive tape 3 1 C Saddle(L.S) with screws Mounting plate D Connecting electric cable for the installation of Room Air Conditioner Read this manual before installation Explain sufficiently the operating means to the user according to the rising up of piping directions Rear left...
... between the indoor unit and the floor should be paid to this manual. Accessory parts Number of articles 1 Remote controller 1 Optional parts for piping 2 R-03 dry battery 2 Mark A Parts name Non-adhesive tape B Adhesive tape 3 1 C Saddle(L.S) with screws Mounting plate D Connecting electric cable for the installation of Room Air Conditioner Read this manual before installation Explain sufficiently the operating means to the user according to the rising up of piping directions Rear left...
User Manual
Page 4
... gas pipes shall be insulated as they become Iow temperature in consideration of Installation Place Outdoor Unit Place, robust not causing vibration, where the body can be reached. Selection of fixing the remote controller on a wall, place where the indoor unit can be left. Use optional parts for piping set up in a distance where the power cable can receive signals when the fluorescent lamps in a room...
... gas pipes shall be insulated as they become Iow temperature in consideration of Installation Place Outdoor Unit Place, robust not causing vibration, where the body can be reached. Selection of fixing the remote controller on a wall, place where the indoor unit can be left. Use optional parts for piping set up in a distance where the power cable can receive signals when the fluorescent lamps in a room...
User Manual
Page 5
... ", for left piping. Indoor unit Indoor unit 1.Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is separately sold, and then fasten the plate to the fixed mounting bar. Install piping hole cover and seal it off with putty after installation Indoor side Wall hole 60mm Outdoor side Thickness of wall (Section of wall hole) G Piping hole pipe 3.Installation of the Indoor Unit Drawing of pipe [ Rear piping ] Draw pipes and the drain hose, then fasten them...
... ", for left piping. Indoor unit Indoor unit 1.Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is separately sold, and then fasten the plate to the fixed mounting bar. Install piping hole cover and seal it off with putty after installation Indoor side Wall hole 60mm Outdoor side Thickness of wall (Section of wall hole) G Piping hole pipe 3.Installation of the Indoor Unit Drawing of pipe [ Rear piping ] Draw pipes and the drain hose, then fasten them...
User Manual
Page 6
... down Open the inlet grille,press the button of unlock in the left piping Heat insulation material Drain hose Piping Indoor/outdoor electric cable Fix with adhesive tape Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape. [Other direction piping] Cut away, with refrigerant oil and connect pipes. Insert the drain hose into the dent of heat insulation materials of the mounting plate. When bending, be taken down perpendicularly. Indoor unit 1. Coat...
... down Open the inlet grille,press the button of unlock in the left piping Heat insulation material Drain hose Piping Indoor/outdoor electric cable Fix with adhesive tape Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape. [Other direction piping] Cut away, with refrigerant oil and connect pipes. Insert the drain hose into the dent of heat insulation materials of the mounting plate. When bending, be taken down perpendicularly. Indoor unit 1. Coat...
User Manual
Page 7
... supply cord is H05/07RN-F or 245IEC57(YZW). 2. Loosen the screws and insert the cable ends fully into left side of the wall hole, in line with the wiring cover. The type of connecting wire is damaged, it with the type of T. 3.15A/250V. 3. A breaker should be replaced by removing its service agent or a similar qualified person. Indoor unit Connecting the indoor/outdoor Electric Cable Removing the wiring cover Remove terminal cover...
... supply cord is H05/07RN-F or 245IEC57(YZW). 2. Loosen the screws and insert the cable ends fully into left side of the wall hole, in line with the wiring cover. The type of connecting wire is damaged, it with the type of T. 3.15A/250V. 3. A breaker should be replaced by removing its service agent or a similar qualified person. Indoor unit Connecting the indoor/outdoor Electric Cable Removing the wiring cover Remove terminal cover...
User Manual
Page 8
... terminal number in the same manner as the indoor unit. 4.Attaching Drain-Elbow If wiring is not correct, proper operation can not be carried out and controller may damage the threads and cause a leakage of gas. If it is used, please attach it as figure. Before adding additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump,then charge additional refrigerant. Drain elbow 6 Drain hose...
... terminal number in the same manner as the indoor unit. 4.Attaching Drain-Elbow If wiring is not correct, proper operation can not be carried out and controller may damage the threads and cause a leakage of gas. If it is used, please attach it as figure. Before adding additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump,then charge additional refrigerant. Drain elbow 6 Drain hose...
User Manual
Page 9
... comes out through flare nut on the valves with specified torque. (4) Open 2-way and 3-way valves using specified torque. (5) Tighten the caps on wide pipe. Piping length 7m 10m Additional amount No need 60g 12m 100g Yasha Silver 18 Yasha Silver 22 Note: When extending piping, air inside piping shall be added per exceeding meter. Charge according to the following list. 7 Outdoor unit...
... comes out through flare nut on the valves with specified torque. (4) Open 2-way and 3-way valves using specified torque. (5) Tighten the caps on wide pipe. Piping length 7m 10m Additional amount No need 60g 12m 100g Yasha Silver 18 Yasha Silver 22 Note: When extending piping, air inside piping shall be added per exceeding meter. Charge according to the following list. 7 Outdoor unit...
User Manual
Page 10
... 3.On Drainage Please install the drain hose so as to the terminal block? Heat insulation of indoor and outdoor firmly inserted to be removed. Is the indoor unit securely fixed? After inserting the flare nut, flaring work is carried out surely to operate through the instruction manual. Less than 5cm It becomes high midway. Check Items for air conditioner. (Over I0A) In the case of Piping Pipe cutting...
... 3.On Drainage Please install the drain hose so as to the terminal block? Heat insulation of indoor and outdoor firmly inserted to be removed. Is the indoor unit securely fixed? After inserting the flare nut, flaring work is carried out surely to operate through the instruction manual. Less than 5cm It becomes high midway. Check Items for air conditioner. (Over I0A) In the case of Piping Pipe cutting...