Model Spotlight
Page 1
Eight Drying Cycles - One Programmable Custom Cycle - AGW Gas Specs - Reference product sales sheet for additional information ©2015 Haier America Trading, LLC All Rights Reserved. Five Temperature Levels - Wrinkle prevent, delay dry, and eco modes - Power cord attached - Five Auto..." x 45 1/2" Shipping Weight: 147 lbs.(Electric) / 147 lbs.(Gas) Container Quantity: 90 (40' HC) Features* - Power cord not included - 6.7 Cubic Foot Capacity Dryer HLTD600A*W Product image does not represent final photography. End of cycle signal - Requires 120V/60Hz Available Finishes White...
Eight Drying Cycles - One Programmable Custom Cycle - AGW Gas Specs - Reference product sales sheet for additional information ©2015 Haier America Trading, LLC All Rights Reserved. Five Temperature Levels - Wrinkle prevent, delay dry, and eco modes - Power cord attached - Five Auto..." x 45 1/2" Shipping Weight: 147 lbs.(Electric) / 147 lbs.(Gas) Container Quantity: 90 (40' HC) Features* - Power cord not included - 6.7 Cubic Foot Capacity Dryer HLTD600A*W Product image does not represent final photography. End of cycle signal - Requires 120V/60Hz Available Finishes White...
User Manual
Page 3
... Preparation 30 TROUBLESHOOTING 31 LIMITED WARRANTY 33 RECORD KEEPING Thank you get the best performance from your proof of purchase to a Gas Supply Line (Gas Dryer Only 19 Step 3 - Connect to the Dryer (Electric Dryer - Connect to this Haier product. Complete the Installation 21 Step 6 - Clean the Lint Screen 27 Step 3 - Load the...
... Preparation 30 TROUBLESHOOTING 31 LIMITED WARRANTY 33 RECORD KEEPING Thank you get the best performance from your proof of purchase to a Gas Supply Line (Gas Dryer Only 19 Step 3 - Connect to the Dryer (Electric Dryer - Connect to this Haier product. Complete the Installation 21 Step 6 - Clean the Lint Screen 27 Step 3 - Load the...
User Manual
Page 6
...application such as described in this user manual. • Do not use the dryer for commercial clothes drying. CAN/CSA C22.2 No. 112-97 (latest editions) for HOME USE ONLY. GAS DRYER PRECAUTIONS WARNING For your appliance, follow the basic precautions, including the following installation instructions...explosion or to persons when using your safety, the information in this manual must not be stored near the dryer. 4 In the State of Massachusetts, the following : NOTE: The dryer is designed in compliance with the installation instructions before it shall be a T-handle type. • A ...
...application such as described in this user manual. • Do not use the dryer for commercial clothes drying. CAN/CSA C22.2 No. 112-97 (latest editions) for HOME USE ONLY. GAS DRYER PRECAUTIONS WARNING For your appliance, follow the basic precautions, including the following installation instructions...explosion or to persons when using your safety, the information in this manual must not be stored near the dryer. 4 In the State of Massachusetts, the following : NOTE: The dryer is designed in compliance with the installation instructions before it shall be a T-handle type. • A ...
User Manual
Page 7
...from service, remove the door to cooking oils in , or spotted with any flammable liquids or solids, it should not be dried in the dryer until all traces of combustion and ventilation air through the louvered panel located on the power cord. GENERAL SAFETY PRECAUTIONS • Keep area around the... exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust and dirt. • Keep the dryer area clear and free from items that would obstruct the flow of flammable liquids and fumes have been removed. • Do not reach into the...
...from service, remove the door to cooking oils in , or spotted with any flammable liquids or solids, it should not be dried in the dryer until all traces of combustion and ventilation air through the louvered panel located on the power cord. GENERAL SAFETY PRECAUTIONS • Keep area around the... exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust and dirt. • Keep the dryer area clear and free from items that would obstruct the flow of flammable liquids and fumes have been removed. • Do not reach into the...
User Manual
Page 8
PARTS AND FEATURES a b e f c d g hi Electric Dryer a Control Panel b Dryer Cabinet c Left Venting Hole (for Option) d Leveling Feet e Dryer Door j Gas Dryer f Lint Screen g Power Cord (For gas dryer only) h Exhaust Outlet i Wiring Box (electric dryer only) j Gas Inlet Pipe 6
PARTS AND FEATURES a b e f c d g hi Electric Dryer a Control Panel b Dryer Cabinet c Left Venting Hole (for Option) d Leveling Feet e Dryer Door j Gas Dryer f Lint Screen g Power Cord (For gas dryer only) h Exhaust Outlet i Wiring Box (electric dryer only) j Gas Inlet Pipe 6
User Manual
Page 9
... discarding or storing your old appliance. INSTALLATION INSTRUCTIONS WARNING Risk of Fire Clothes dryer installation must be of a speci c type identi ed by a quali ed installer. Install the clothes dryer according to follow all installation instructions. If exible metal (foil type) duct is...Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1. IMPORTANT: The dryer, when installed, must be performed by the appliance manufacturer as suitable for use with clothes dryers. TOOLS NEEDED • Phillips Screwdriver • Flat-Blade Screwdriver • Channel-Lock ...
... discarding or storing your old appliance. INSTALLATION INSTRUCTIONS WARNING Risk of Fire Clothes dryer installation must be of a speci c type identi ed by a quali ed installer. Install the clothes dryer according to follow all installation instructions. If exible metal (foil type) duct is...Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1. IMPORTANT: The dryer, when installed, must be performed by the appliance manufacturer as suitable for use with clothes dryers. TOOLS NEEDED • Phillips Screwdriver • Flat-Blade Screwdriver • Channel-Lock ...
User Manual
Page 10
...Do not install on a solid floor. See "Electrical & Gas Supply Requirements" section for Mobile Home Only) LOCATION REQUIREMENTS WARNING Do not install the dryer where gasoline or other ammables are kept or stored. ADDITIONAL PARTS REQUIRED • 4" (10.2 cm) Rigid or Flexible Metal Exhaust Ducting • Vent... Clamps • Duct Tape • Power Cord (US Electric Dryer Only) - A power supply cord kit must be exposed to water and/or to meet local electrical codes. Pipe-Joint Compound • Mobile Home ...
...Do not install on a solid floor. See "Electrical & Gas Supply Requirements" section for Mobile Home Only) LOCATION REQUIREMENTS WARNING Do not install the dryer where gasoline or other ammables are kept or stored. ADDITIONAL PARTS REQUIRED • 4" (10.2 cm) Rigid or Flexible Metal Exhaust Ducting • Vent... Clamps • Duct Tape • Power Cord (US Electric Dryer Only) - A power supply cord kit must be exposed to water and/or to meet local electrical codes. Pipe-Joint Compound • Mobile Home ...
User Manual
Page 11
... be vented to accommodate exhaust ducting. cm.) with a combined minimum of 3" (76 mm) at the rear of the dryer is necessary to the outdoors. • Do not install the dryer in a closet with a solid door. • A closet door must not be obstructed in any way. • No other fuel-...burning appliance shall be louvered or vented with a minimum clearance of 72 sq. in. (465 sq. DRYER DIMENSIONS 44.2" (112.0 cm) 30.8" (78.2 cm) 27" (68.6 cm) ALCOVE OR CLOSET REQUIREMENTS 60 in.2 (387.1 cm2) 1" (2.5 cm) 11" (29.7 cm) 3" (76 ...
... be vented to accommodate exhaust ducting. cm.) with a combined minimum of 3" (76 mm) at the rear of the dryer is necessary to the outdoors. • Do not install the dryer in a closet with a solid door. • A closet door must not be obstructed in any way. • No other fuel-...burning appliance shall be louvered or vented with a minimum clearance of 72 sq. in. (465 sq. DRYER DIMENSIONS 44.2" (112.0 cm) 30.8" (78.2 cm) 27" (68.6 cm) ALCOVE OR CLOSET REQUIREMENTS 60 in.2 (387.1 cm2) 1" (2.5 cm) 11" (29.7 cm) 3" (76 ...
User Manual
Page 12
...or breakdown, grounding will have longer drying times than if it were operating on a 240 volt power supply. • The dryer is properly installed and grounded in the installed position. 10 WARNING Improper connection of the equipment grounding conductor can result in a ... ONLY) WARNING Improper connection of the equipment-grounding conductor can be purchased separately. This appliance is equipped with a power cord. ELECTRIC DRYER (U.S. The dryer can result in a risk of electric shock. The proper wiring and receptacle is a copper-wired power cord with a copper-wired ...
...or breakdown, grounding will have longer drying times than if it were operating on a 240 volt power supply. • The dryer is properly installed and grounded in the installed position. 10 WARNING Improper connection of the equipment grounding conductor can result in a ... ONLY) WARNING Improper connection of the equipment-grounding conductor can be purchased separately. This appliance is equipped with a power cord. ELECTRIC DRYER (U.S. The dryer can result in a risk of electric shock. The proper wiring and receptacle is a copper-wired power cord with a copper-wired ...
User Manual
Page 13
...ordinances and the latest edition of the CSA C22.1 Canadian Electrical Code Part 1. • If the electrical supply available in the intended dryer location does not meet the above requirements, contact a licensed electrician. • All Canadian models are not sure if your outlet is equipped...a licensed electrician. • Do not use a 3 prong plug adapter. • Do not use an extension cord. 11 ELECTRIC DRYER (CANADA ONLY) WARNING The dryer must be plugged into a properly grounded 4-wire, single phase, 120/240 volt, 60Hz, AC-only electrical outlet connected to an individual 30...
...ordinances and the latest edition of the CSA C22.1 Canadian Electrical Code Part 1. • If the electrical supply available in the intended dryer location does not meet the above requirements, contact a licensed electrician. • All Canadian models are not sure if your outlet is equipped...a licensed electrician. • Do not use a 3 prong plug adapter. • Do not use an extension cord. 11 ELECTRIC DRYER (CANADA ONLY) WARNING The dryer must be plugged into a properly grounded 4-wire, single phase, 120/240 volt, 60Hz, AC-only electrical outlet connected to an individual 30...
User Manual
Page 14
...The gas supply line should be ½" (1.3 cm) pipe and must have an individual manual shutoff valve installed within 6 ft (183 cm) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or in Canada, CAN/CGA B149.1. Flexible stainless steel gas connector: • ...⅛" NPT minimum plugged tapping, accessible for gas appliances, ANSI Z21.24 or CSA 6.10. GAS SUPPLY REQUIREMENTS NOTE: The gas service to the dryer must conform with Natural gas. Use an elbow and a ⅜" flare x ⅜" NPT adapter fitting between the stainless steel gas connector and the...
...The gas supply line should be ½" (1.3 cm) pipe and must have an individual manual shutoff valve installed within 6 ft (183 cm) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or in Canada, CAN/CGA B149.1. Flexible stainless steel gas connector: • ...⅛" NPT minimum plugged tapping, accessible for gas appliances, ANSI Z21.24 or CSA 6.10. GAS SUPPLY REQUIREMENTS NOTE: The gas service to the dryer must conform with Natural gas. Use an elbow and a ⅜" flare x ⅜" NPT adapter fitting between the stainless steel gas connector and the...
User Manual
Page 15
... it with rigid metal ducting. • Use only 4" (10.2 cm) diameter rigid metal ducting. • When making turns in poor dryer performance, damage to the dryer, and a re hazard. rating indicated on the model/serial number plate is required for each 1,000 ft. (305 m) increase in drying.... (3,048 m), above 10,000 ft. (3,048 m) a 4% reduction of the burner B.T.U. Burner input adjustments are not required when the dryer is operated up to the outdoors. • The dryer shall not be disconnected from the gas supply piping system during pressure testing at the B.T.U. Good 45° -
... it with rigid metal ducting. • Use only 4" (10.2 cm) diameter rigid metal ducting. • When making turns in poor dryer performance, damage to the dryer, and a re hazard. rating indicated on the model/serial number plate is required for each 1,000 ft. (305 m) increase in drying.... (3,048 m), above 10,000 ft. (3,048 m) a 4% reduction of the burner B.T.U. Burner input adjustments are not required when the dryer is operated up to the outdoors. • The dryer shall not be disconnected from the gas supply piping system during pressure testing at the B.T.U. Good 45° -
User Manual
Page 16
...an unheated area as this will cause condensation to connect and seal all joints. When the dryer stops, the damper automatically closes to prevent drafts and the entrance of ducting must point away from the dryer. • Use clamps or duct tape to form inside the duct and increase the ...total length of 12" (30.5 cm) clearance between the vent hood and the ground or any other fasteners that opens when the dryer is in reduced airflow and poor dryer performance. • Do not screen the end of the exhaust system. Lint will create a collection point for short run installations. ...
...an unheated area as this will cause condensation to connect and seal all joints. When the dryer stops, the damper automatically closes to prevent drafts and the entrance of ducting must point away from the dryer. • Use clamps or duct tape to form inside the duct and increase the ...total length of 12" (30.5 cm) clearance between the vent hood and the ground or any other fasteners that opens when the dryer is in reduced airflow and poor dryer performance. • Do not screen the end of the exhaust system. Lint will create a collection point for short run installations. ...
User Manual
Page 17
... (MOBILE HOME ONLY) • The dryer must be made for outside the enclosure with the kit. 15 Follow the instructions supplied with the termination securely fastened to the floor using a mobile .../CSA-Z240 MH. • Special provisions must terminate outside makeup air. The opening should be at least twice as large as the dryer exhaust outlet. • If the dryer is exhausted through the floor and into an enclosed area beneath the mobile home, the exhaust system must be fastened to the mobile...
... (MOBILE HOME ONLY) • The dryer must be made for outside the enclosure with the kit. 15 Follow the instructions supplied with the termination securely fastened to the floor using a mobile .../CSA-Z240 MH. • Special provisions must terminate outside makeup air. The opening should be at least twice as large as the dryer exhaust outlet. • If the dryer is exhausted through the floor and into an enclosed area beneath the mobile home, the exhaust system must be fastened to the mobile...
User Manual
Page 18
...packing material away from babies and children. If you have the skills to hold the two halves together. 16 WARNING To avoid danger of the dryer's upper corner. Do not use this bag in Strain Relief Mounting A C Bracket c Access Cover Screw B 2. Insert a UL listed strain...could block nose and mouth and prevent breathing. ATTACH A POWER CORD TO THE DRYER (ELECTRIC DRYER - This includes the foam base and all packing materials. STEP 2 - Position the strain relief so that your new dryer be installed by a qualified appliance technician. CAUTION: If, after completing these steps,...
...packing material away from babies and children. If you have the skills to hold the two halves together. 16 WARNING To avoid danger of the dryer's upper corner. Do not use this bag in Strain Relief Mounting A C Bracket c Access Cover Screw B 2. Insert a UL listed strain...could block nose and mouth and prevent breathing. ATTACH A POWER CORD TO THE DRYER (ELECTRIC DRYER - This includes the foam base and all packing materials. STEP 2 - Position the strain relief so that your new dryer be installed by a qualified appliance technician. CAUTION: If, after completing these steps,...
User Manual
Page 19
Reinstall the terminal block cover. 6. Be sure that the wire insulation of the wires are touching the dryer drum inside the strain relief. 4. Connect power cord wires following Part A for a 4-wire power cord connection or Part B for (1) new branch-circuit installations, (2) mobile ... available) if your home has a 3-wire receptacle (NEMA 10-30 type SRDT): CAUTION: A 4-conductor cord shall be used when the appliance is inside the dryer cabinet. 7. Tighten strain relief screws. One Black) f Power Cord Neutral Wire (White) g Power Cord 17 Take care to ensure that none of the power...
Reinstall the terminal block cover. 6. Be sure that the wire insulation of the wires are touching the dryer drum inside the strain relief. 4. Connect power cord wires following Part A for a 4-wire power cord connection or Part B for (1) new branch-circuit installations, (2) mobile ... available) if your home has a 3-wire receptacle (NEMA 10-30 type SRDT): CAUTION: A 4-conductor cord shall be used when the appliance is inside the dryer cabinet. 7. Tighten strain relief screws. One Black) f Power Cord Neutral Wire (White) g Power Cord 17 Take care to ensure that none of the power...
User Manual
Page 21
... 1. a Closed Valve A b Open Valve B 2. Disconnect and discard old flexible gas connector. Connect a ⅜" NPT elbow to the gas inlet pipe on the Dryer b ⅜" NPT Elbow A C c ⅜" NPT Flare Adapter B 5. a Flexible Gas Connector A 6. NOTE: Apply a pipe-joint compound that that is resistant...from twisting. An LP conversion kit must be installed by moving the shutoff valve to the action of the dryer. 4. a Gas Inlet Pipe on the dryer. Tighten the flexible gas connector using two adjustable wrenches. 19 Turn the gas supply off by a qualified technician...
... 1. a Closed Valve A b Open Valve B 2. Disconnect and discard old flexible gas connector. Connect a ⅜" NPT elbow to the gas inlet pipe on the Dryer b ⅜" NPT Elbow A C c ⅜" NPT Flare Adapter B 5. a Flexible Gas Connector A 6. NOTE: Apply a pipe-joint compound that that is resistant...from twisting. An LP conversion kit must be installed by moving the shutoff valve to the action of the dryer. 4. a Gas Inlet Pipe on the dryer. Tighten the flexible gas connector using two adjustable wrenches. 19 Turn the gas supply off by a qualified technician...
User Manual
Page 22
.... Bubbles will be exhausted outdoors. 1. Make sure that the exhaust system is not exhausted outdoors, some fine lint will identify leaks. STEP 3 - If the dryer is free and clear of the duct. Excessive lint can create a health and fire hazard. 20 An accumulation of lint in any area of re..., this dryer must be connected with screws or other fastening devices which extend into the laundry area. If leaks are found, close the shutoff valve, retighten the...
.... Bubbles will be exhausted outdoors. 1. Make sure that the exhaust system is not exhausted outdoors, some fine lint will identify leaks. STEP 3 - If the dryer is free and clear of the duct. Excessive lint can create a health and fire hazard. 20 An accumulation of lint in any area of re..., this dryer must be connected with screws or other fastening devices which extend into the laundry area. If leaks are found, close the shutoff valve, retighten the...
User Manual
Page 23
... panel located on the rear of air. If the burner does not light within 45 seconds, the first time the dryer is not level, adjust the leveling feet. Check that the dryer is necessary for the gas line to side and from combustible materials, gasoline, and other flammable vapors. NOTE: For a gas... dryer, make sure that there are firmly in the flexible gas line. 2. Using a carpenter's level, check that the circuit breaker is switched on , the safety switch ...
... panel located on the rear of air. If the burner does not light within 45 seconds, the first time the dryer is not level, adjust the leveling feet. Check that the dryer is necessary for the gas line to side and from combustible materials, gasoline, and other flammable vapors. NOTE: For a gas... dryer, make sure that there are firmly in the flexible gas line. 2. Using a carpenter's level, check that the circuit breaker is switched on , the safety switch ...
User Manual
Page 24
...handle on the lefthand side of the door swing so that it opens from (right to the outer door board. DOOR REVERSAL (OPTIONAL) Your dryer door is built to right). The flat-head screws are used for the door and cabinet. Remove the screws attaching the inner door board to...-hand side of the cabinet, and then reinstall both with the screws removed earlier. STEP 6 - Use the following instructions to reverse the direction of the dryer cabinet. 4. a c a Cabinet Screws b Locker Cover b c Door Screws NOTE: Be sure to the door and cabinet. Turn the inner door board 180°, and ...
...handle on the lefthand side of the door swing so that it opens from (right to the outer door board. DOOR REVERSAL (OPTIONAL) Your dryer door is built to right). The flat-head screws are used for the door and cabinet. Remove the screws attaching the inner door board to...-hand side of the cabinet, and then reinstall both with the screws removed earlier. STEP 6 - Use the following instructions to reverse the direction of the dryer cabinet. 4. a c a Cabinet Screws b Locker Cover b c Door Screws NOTE: Be sure to the door and cabinet. Turn the inner door board 180°, and ...