Popular Haier FCE-204BCB2B Manual Pages
User Manual - Page 1
... FCE-034BCB2A FCE-051BCB2A FCE-068BCB2A FCE-085BCB2A FCE-102BCB2A FCE-136BCB2A FCE-170BCB2A FCE-204BCB2A FCE-238BCB2A
FCE-034BCD2A FCE-051BCD2A FCE-068BCD2A FCE-085BCD2A FCE-102BCD2A FCE-136BCD2A FCE-170BCD2A FCE-204BCD2A FCE-238BCD2A FCE-034BCB2B FCE-051BCB2B FCE-068BCB2B FCE-085BCB2B FCE-102BCB2B FCE-136BCB2B FCE-170BCB2B FCE-204BCB2B FCE-238BCB2B
• Please read this operation manual...
User Manual - Page 2
... chiller air conditioning system featuring high profession and high technological requirement. ■ About This Manual
Table of Contents About This Manual Product Introduction Unit Overall Dimensions and Weight Unit Installation Installation Inspection & Startup Unit Maintenance Troubleshooting Cautions Safety precautions Notes for safety
1 2 3-4 5-7 8 9 10 11-12 12-14 15
Important Notice...
User Manual - Page 3
... tightly wrapped with slit plain foil through tube expanding mechanically. Forged brass inlet/outlet joint, reliable
and durable.
Motor with draw-out surface cooler, easy repair and maintenance.
High heat transmission efficiency and adequate cooling (heating) capacity. 3.Big air flow, low noise. Combined high static pressure 30Pa and low static pressure...
User Manual - Page 4
... x 22
Standard drip tray
Extended drip tray
Model
Overall dimension (mm)
A
B
C
FCE-034BCN2A 624
508
478
FCE-051BCN2A 624
508
478
FCE-068BCN2A 944
808
778
FCE-085BCN2A 944
808
778
FCE-102BCN2A 944
808
778
FCE-136BCN2A 1374
1238
1208
FCE-170BCN2A 1374
1238
1208
FCE-204BCN2A 1634
1498
1468
FCE-238BCN2A 1634
1498
1468
Weight (kg)
12.5 13...
User Manual - Page 5
...
28.5 FCE-136BCB2B 28.7 FCE-170BCB2B 34.5 FCE-204BCB2B 34.9 FCE-238BCB2B
1634 1634 1754 1754
1238 1238 1498 1498
1208 1208 1468 1468
1183 1183 1443 1443
Weight (kg)
15.4 15.5 18.8 19.0 19.1 29.4 29.6 34.9 35.3
4 • Unit Overall Dimensions and Weight
Standard drip tray
Extended drip tray
Model
FCE-034BCD2A FCE-051BCD2A FCE-068BCD2A FCE-085BCD2A...
User Manual - Page 6
...installation; 3.Make sure hanging structure adequate to support the unit weight; 4.All units shall be made ; Please install according to the following items before inspection and confirmation by the hanging rods. Installation Precautions
To ensure good installation... a joint inspection; 6.Do not repair it yourself before installation of chilled water valves and pipelines shall be leveled ...
User Manual - Page 7
... threaded connector. Note: Before maintenance, the power supply shall be transparent. ■ Unit Installation
4.Assemble lower nut and washer to Unit Overall Dimensions and Weight.
Refer to fix the unit... connection Air ducts made of galvanized steel sheet of certain thickness (provided by the installer) may be of copper. Same for dimensions of the building. See Unit Overall ...
User Manual - Page 9
... motor speed switch or the controller. This manual has been carefully read through. Startup The ...pipe connection has been completed with a temperature setting dial. Air Discharge For first water filling, ...Installation Inspection & Startup
Installation Inspection
After installation, the installers shall re-inspect and confirm the following items have been completely connected and firmly installed...
User Manual - Page 10
... Clean and repair it rotates freely without obstacles; 3. Manually turn the blades to make descaling and water replacement. Drain chilled ...tray must keep clean, otherwise immediate cleaning must be guided by two installers to ensure safety.
3. Note: To avoid human ...capacity. Due to limitation of support weight and dimensions, this job shall be made.
9 ■ Unit ...
User Manual - Page 11
• Troubleshooting
Common troubles and clearing measures:
Faults
Causes
Clearing measures
Too low air flow
Dirty filter Blocked air outlet
Clean or replace Clear the block
Big noise of the unit Noise from fan bearing
Repair or replace
Dirty filter
Clean or replace
Insufficient cooling (heating) effect
Cold (hot) water not cold (hot) enough Small water flow...
User Manual - Page 12
...services nearest to your house.
•Do not damage any parts of the air conditioner that may arise due to nonobservation of the following instructions...specifications.
• Always remember not to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
• Installation shall be done by professional people, and don't install...electrical repairs must...
User Manual - Page 13
... be all-pole switch; Specifications
The refrigerating circuit is adaptive... ventilation grille of the connecting cable:
Model ALL
Connecting cable Power cable: H05RN-F... new user, this manual should be at hand... for disconnection must be replaced by the manufacturer or ...INSTRUCTIONS!
Incorrect operations may result in line with the air conditioner. and the distance between its service...
User Manual - Page 14
... should be required. g. decrease too low either. Incorrect maintenance and repairment may cause injuries.
• Call the dealer to take measures to prevent the water from...is co-used with damp hands. Incorrect installation may cause suffocation.
• Don't operate the air-conditioner with other heat-radiator the frequent replacement of air-conditioner, which may cause ...
User Manual - Page 15
... gas pipe, water pipe, lightning rod , in-correct earthing may fall down and cause accidents.
• Pets and plants should be installed in the air flow. If the damaged base isnot repaired, the unit may cause shock.
0
Earthing
It easily cause electrical shock without circuit breaker.
• Use discharge pipe correctly to...
User Manual - Page 16
...the human being would be leaked during cooling, and other failures would also occur. The instructions with this warning mark must be carried out strictly, for they are all concerned with safety of...all concerned with the gas pipe, water pipe, lightening arrester, or phone line. • Never install the air conditioner where the flammable gas is easily leaked. • Do not spray any paint or...