... can cause personal injury or damage of refrigerant during installation and make fixed wiring layout according to national wiring standard by authorized organization and professional personnel. Contents marked with this installation instruction and operation manuals should be done after finishing installation. Unauthorized installation may cause water leakage, electric shock and...
User Manual - Page 3
.... Where windows and doors are exposed to outdoor air of high humidity.
2.Insulation of metal parts of building and air conditioner should be carried on in place where flammable gas...be of the series are different
2 Confirmation of electrical appliances and facilities.
3.Installation place for space of installation and maintenance. (Here we only use simple drawing as figurations ...
User Manual - Page 4
... bolt less than 40mm. Install a guard ring and then seal it with its outside inclining lower slightly. Installation of suspending bolts
Installation of supporting frame for AC092,122,142... than 40mm. Prior to installation
Hole through the wall
Drill a hole of 70 mm diameter through the wall
As shown in under ceiling
1. Installation of Air Conditioner
Installation in the diagram at the...
User Manual - Page 5
... beam wood on the girder and set supporting angle iron
Hook bolt
Old concrete building Use inlet hinge joint, inlet plug or inlet bolt. Fasten hexagon bolt and fix the air conditioner.
4
Installation position of attached hexagon bolt
indoor subassembly
3-18mm bolt
Hooks and chains Installation status
4. Installation of air conditionert
for suspension
Internal suspension (AC092...
User Manual - Page 6
...washer on the bottom of the machine (only for floor type).
(2) As shown in the diagram on
the left and right, select one according to practical conditions.
After confirming outlet direction of pipeline, wiring and drainage pipe, drill a hole through the wall according
right
to method prescribed.
down
(3) Install supporting...pipeline and wiring. Indoor part of drainage pipe should...
User Manual - Page 7
... right diagram. To type AC092-282FEBHA units used refrigerant R22. Note: Outlet direction of distribution tube
Please read installation manual attached with unit of the distribution tube. Poor heat insulation can cause moisture condensation and result in water leakage
6
Indoor part of outdoor unit. Material and specification of distribution tube
Material of distribution tube Type...
User Manual - Page 8
...supporting frame should be done respectively in fluid and gas side. To prevent moisture condensation, heat insulation measures MUST be taken to guard against water leakage. Heat insulation measures should be taken to joint part... for firm adherence to the two sides. During refrigeration, temperatures in following diagram.
1.5m~2m Supporting frame
(About 10cm )
Slopedown degree over 1/100...
User Manual - Page 9
...indoor unit.
Notice
Install electrical leakage protector. Systems of refrigerant distribution tube and control wiring should coincide with wiring layout rules concerning installation of the air cinditioner should be... be grounded. Item
Indoor unit
Connecting cable
Model
AC092262 FEAHA
AC092262 FEBHA
power
AC 220230V, 50Hz
Manual switch
15A
Fuse 15A
Power wire (L) Central...
User Manual - Page 10
...layer as isolation) remote controller grouped control (shield layer as isolation)
leak breaker manual switch communication wire
centralized control signal wire
remote controller
shield layer should be connected ...the above is in ìONî status, group number can only be set either by dialing codes on SW02. Refer to prevent wrong connection that of number 3 respectively
(according...
User Manual - Page 11
... and fire hazard.
1.Wrap tapes on distribution tube of refrigerant, wires in air conditioner room and drainage pipe after finishing installation, dial code of emergency switch (SW04) to reasons such as installation position of valves in the following table: Ability setting SW05.
12 34
10 There is code switch SW03 on the wall with other equipment and make...
User Manual - Page 12
...operation manualî for indoor and outdoor units. In the case that of ìsetting temperatureî button. Trial run (Trial run of either cooling or heating can make air conditioner run
...
Disorders in trial run . It is not a defect if trouble-shooting code ì95î is absolutely FOBIDDEN to manually operate AC contactor of outdoor unti to compulsorily execute trial run
Flashing...