User Manual - Page 2
... layout MUST apply specified power cables and be grounded.
Safety Precautions
Read this installation instruction and operation manuals should be strong enough to bear the weight of the assembly to ensure no leakage of refrigerant after installation of machine, which cannot be installed on unspecified metal structures (e.g. Trial run MUST be connected to gas pipe, tapping...
User Manual - Page 3
... water. Where ceilingís height is of evenly circulating cool and hot air.
In addition, heat preservation measure should be installed according to instructions to ensure smooth discharge of the series are exposed to outdoor air of high humidity.
2.Insulation of metal parts of building and air conditioner should be taken to prevent moisture condensation. Confirmation of...
User Manual - Page 4
Installation of Air Conditioner
Installation in the diagram at the right, remove two screw snails as figurations of the series are different)
Type
A (mm) B (mm) C (mm)
AC092,122,142,162FEAHA, AC092,122,142,162FEBHA
990
990
AC182,242,282FEAHA, AC182,242,282FEBHA
1332
1244
Installation mode Internal suspension External suspension
Type
D (mm) E (mm) F (mm)
AC092,122...
User Manual - Page 5
... suspending bolt and ceiling should be less than 40 mm.
(ceiling)
(ceiling)
of supporting frame
(wall)
The air conditioner cannot be adjusted horizontally after installation of internal suspension, therefore it off to positions of suspending bolts printed on the girder and set supporting angle iron
Hook bolt
Old concrete building Use inlet hinge joint, inlet plug...
User Manual - Page 6
... snail, 12 washer on the left and right, select one according to
rear
practical conditions. After confirming outlet
direction of drainage pipe should incline from
higher inside to lower outside end. backward downward
Right drainage hole
5
There are two drainage holes respectively on the bottom of floor console
1. down
(3) Install supporting frame as...
User Manual - Page 7
... leakage). 3. Indoor part of mm. Note
During air tightness test, indoor unit cannot be made heatproof with unit of drainage pipe should be done from condensation. Correct
NO
Drainage pipe Incorrect
NO
Drainage pipe Incorrect
Refrigerant distribution tube
Allowable length of distribution tube
Allowable deviation of distribution tube
Please read installation manual attached with...
User Manual - Page 8
... measures MUST be taken to joint part between drainage pipe and indoor assembly. Connection of drainage pipe. Aggregative distribution tube is long, a supporting frame should be taken to indoor ...backwater etc. Same measures also should be formed. Drainage pipe is less than 20m. During refrigeration, temperatures in fluid and gas side. should be taken to the two sides. Transverse ...
User Manual - Page 9
.... Notice
Install electrical leakage protector. Omission of connected terminals. Improper connection can cause electric shock. Comply with the same system. Remote controller wire
Specification of power supply shall be implemented by wires transferring to the same power supply. Item
Indoor unit
Connecting cable
Model
AC092262 FEAHA
AC092262 FEBHA
power
AC 220230V, 50Hz
Manual switch...
User Manual - Page 10
... can control a group of 16 indoor unit at the maximum).
(6)Disassemble short connection wire to installaiton manual of centralized controller
Operation control
Solution of group control
One set of remote controller can be set either by dialing codes on SW02. While ì7î position of SW02 is number 16 in right table.
Requirement
remote...
User Manual - Page 11
... and fire hazard.
1.Wrap tapes on distribution tube of temperature
2
Setting before leaving factory. There is code switch SW03 on distribution tube which is as the following table.
(SW03) Position of code swith (restricted to position 1and 2 only)
Increased value of refrigerant, wires in air conditioner room and drainage pipe after finishing these engineering.
2.Fix them...
User Manual - Page 12
...; in the status of indoor unit changes one remote controller controls multiple air conditioners, pressing ìsetting temperatureî button during compulsory trial run. 4. It is not a defect if trouble-shooting code ì95î is absolutely FOBIDDEN to manually operate AC contactor of ìsetting temperatureî button. Confirm drainage conditions while trial run
! Requirement...