Service Manual
Page 3
...console type, "U" stands for outdoor of split unit Max. 1 to 3 1.2 Brief Introduction for T1,T2,T3 working condition Type of Conditioner Cooling Only Air T1 18 ℃~43℃ Heat pump -7℃~43℃ Electricity Heating ~43℃ Climate type T2 10℃~35℃ -7... Operating Range of products & features 1.1. outdoor DB℃ 7 24 WB℃ 6 18 Minimum 18 14 -10 6 15 --15 -- -3- 1.Description of Air Conditioners Working temperature range Rated Maximum Cooling Indoor DB℃ 27 32 WB℃ 19 23 outdoor DB℃ 35 43 WB℃ 24 26 Heating...
...console type, "U" stands for outdoor of split unit Max. 1 to 3 1.2 Brief Introduction for T1,T2,T3 working condition Type of Conditioner Cooling Only Air T1 18 ℃~43℃ Heat pump -7℃~43℃ Electricity Heating ~43℃ Climate type T2 10℃~35℃ -7... Operating Range of products & features 1.1. outdoor DB℃ 7 24 WB℃ 6 18 Minimum 18 14 -10 6 15 --15 -- -3- 1.Description of Air Conditioners Working temperature range Rated Maximum Cooling Indoor DB℃ 27 32 WB℃ 19 23 outdoor DB℃ 35 43 WB℃ 24 26 Heating...
Service Manual
Page 4
...HAIER DAC split inverter type The indoor units are universal for the outdoors which will control refrigerant flow more precisely. And the outdoor can be back to be controlled at 10℃. Auto-restart function (optional) All indoor units have already installed the air conditioner..., if you have auto-restart function. Commercial Air Conditioner 1.4 Product features DC inverter technology, high energy efficiency, higher EER A+, energy saving for the user The ...
...HAIER DAC split inverter type The indoor units are universal for the outdoors which will control refrigerant flow more precisely. And the outdoor can be back to be controlled at 10℃. Auto-restart function (optional) All indoor units have already installed the air conditioner..., if you have auto-restart function. Commercial Air Conditioner 1.4 Product features DC inverter technology, high energy efficiency, higher EER A+, energy saving for the user The ...
Service Manual
Page 5
... unit 220V/1/ (50/60Hz) SERIES Cassette Type(4-way) kBTU/h kW Floor & Ceiling type ceiling concealed duct HEM mounted type Console type 7 9 12 18 24 2.2 2.8 3.6 5.0 6.5 -5- Commercial Air Conditioner on the operation panel. Weekly timing function, if connected with a central controller That is convenient for building management. Then according to the failure code chart...
... unit 220V/1/ (50/60Hz) SERIES Cassette Type(4-way) kBTU/h kW Floor & Ceiling type ceiling concealed duct HEM mounted type Console type 7 9 12 18 24 2.2 2.8 3.6 5.0 6.5 -5- Commercial Air Conditioner on the operation panel. Weekly timing function, if connected with a central controller That is convenient for building management. Then according to the failure code chart...
Service Manual
Page 47
...diameter to the terminal block and fasten screw. Note: Power line and communication wire are provided by wire cover. Electric wiring The air conditioner must be copper wire.Power supply: 1PH, 220-230V~, 50/60Hz. The grounding wire and the neutral wire shall be fastened by...liquid stop valve Hexagonal wernch Close Gas stop valve Valve cap 1. The electric leakage breaker must be strictly separated. The wiring method of air conditioner or the unit can not operate. 3. Crimp connection method for wires without orbicular terminals, its wiring method is Y connection. The wire...
...diameter to the terminal block and fasten screw. Note: Power line and communication wire are provided by wire cover. Electric wiring The air conditioner must be copper wire.Power supply: 1PH, 220-230V~, 50/60Hz. The grounding wire and the neutral wire shall be fastened by...liquid stop valve Hexagonal wernch Close Gas stop valve Valve cap 1. The electric leakage breaker must be strictly separated. The wiring method of air conditioner or the unit can not operate. 3. Crimp connection method for wires without orbicular terminals, its wiring method is Y connection. The wire...