Use and Care Manual
Page 1
... GEAppliances.com. 991.0480.237 GE is a trademark of the hood. RANGE HOODS SAFETY INFORMATION 3 USING THE HOOD Controls 5 Chef Connect 6 CARE AND CLEANING Filters 7 Surfaces 8 Lights 8 INSTALLATION INSTRUCTIONS . . 9 TROUBLESHOOTING TIPS 20 WARRANTY 21 ACCESSORIES 22 CONSUMER SUPPORT 24 OWNER'S MANUAL & INSTALLATION INSTRUCTIONS JVX3240 JVX3300 JVX5300 JVX5360 JVX5305 JVX5365 PVX7300 PVX7360 Write the model and serial numbers here: Model Serial You can find them on a label on the inside of the General Electric Company. Manufactured under trademark license...
... GEAppliances.com. 991.0480.237 GE is a trademark of the hood. RANGE HOODS SAFETY INFORMATION 3 USING THE HOOD Controls 5 Chef Connect 6 CARE AND CLEANING Filters 7 Surfaces 8 Lights 8 INSTALLATION INSTRUCTIONS . . 9 TROUBLESHOOTING TIPS 20 WARRANTY 21 ACCESSORIES 22 CONSUMER SUPPORT 24 OWNER'S MANUAL & INSTALLATION INSTRUCTIONS JVX3240 JVX3300 JVX5300 JVX5360 JVX5305 JVX5365 PVX7300 PVX7360 Write the model and serial numbers here: Model Serial You can find them on a label on the inside of the General Electric Company. Manufactured under trademark license...
Use and Care Manual
Page 3
..., cookie sheet or metal tray, then turn hood ON when cooking at service panel and lock the service disconnecting means to prevent power from being called. 4. Before servicing or cleaning unit, switch power off the burner. Do not use cookware appropriate for the size of the surface element. B. Clean ventilating fans frequently. WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE...
..., cookie sheet or metal tray, then turn hood ON when cooking at service panel and lock the service disconnecting means to prevent power from being called. 4. Before servicing or cleaning unit, switch power off the burner. Do not use cookware appropriate for the size of the surface element. B. Clean ventilating fans frequently. WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE...
Use and Care Manual
Page 4
... wireless communication device installed on some models) This device complies with a soft cloth and allow to remove the film. SAFETY INFORMATION IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING REMOTE ENABLE EQUIPMENT (on this oven that may not cause harmful interference, and (2) this device must be determined by turning the equipment off and on, the user is encouraged to...
... wireless communication device installed on some models) This device complies with a soft cloth and allow to remove the film. SAFETY INFORMATION IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING REMOTE ENABLE EQUIPMENT (on this oven that may not cause harmful interference, and (2) this device must be determined by turning the equipment off and on, the user is encouraged to...
Use and Care Manual
Page 6
... the fan setting pads. Default Sync Settings: The factory default setting for HIGH speed. The user can be restarted. At this mode. Chef Connect Operation Bluetooth® Connection To pair with other device. This will need to be operated by pressing and holding the Lo pad for 3 seconds. At that will be the brightest. Auto Off Pad: Off switch for fan. It will turn off . 3. Rangehood Control Panel...
... the fan setting pads. Default Sync Settings: The factory default setting for HIGH speed. The user can be restarted. At this mode. Chef Connect Operation Bluetooth® Connection To pair with other device. This will need to be operated by pressing and holding the Lo pad for 3 seconds. At that will be the brightest. Auto Off Pad: Off switch for fan. It will turn off . 3. Rangehood Control Panel...
Use and Care Manual
Page 7
... vent hood. CARE AND CLEANING: Filters Filters Be sure the circuit breaker is off and all surfaces are cool before cleaning or servicing any part of the blower. 3. To inquire about purchasing replacement charcoal filters or to secure the filter. To replace: Fit the tabs at the bottom of a dealer nearest you, please call our toll-free number: National Parts Center 800.626.2002 To install (on this configuration one grease filter...
... vent hood. CARE AND CLEANING: Filters Filters Be sure the circuit breaker is off and all surfaces are cool before cleaning or servicing any part of the blower. 3. To inquire about purchasing replacement charcoal filters or to secure the filter. To replace: Fit the tabs at the bottom of a dealer nearest you, please call our toll-free number: National Parts Center 800.626.2002 To install (on this configuration one grease filter...
Use and Care Manual
Page 8
... lights to replace the lights, make sure that you , please call our toll-free number: National Parts Center 800.626.2002 GEApplianceParts.com www.barkeepersfriend.com/ge Painted Surfaces (on some models) Do not use a steel wool pads or other surfaces. Replace with moist hands or cloth. Always let the light cool completely before touching. Remove light cover. 3. they will scratch the surface. Lights NOTE: When cleaning, take care...
... lights to replace the lights, make sure that you , please call our toll-free number: National Parts Center 800.626.2002 GEApplianceParts.com www.barkeepersfriend.com/ge Painted Surfaces (on some models) Do not use a steel wool pads or other surfaces. Replace with moist hands or cloth. Always let the light cool completely before touching. Remove light cover. 3. they will scratch the surface. Lights NOTE: When cleaning, take care...
Use and Care Manual
Page 9
... installation, switch power off at the main circuit breaker or fuse box before installing. When the service disconnecting means cannot be sure to leave these instructions for future reference. • Skill level - Installation work and electrical wiring must always be done by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. D. Installation of this vent hood requires...
... installation, switch power off at the main circuit breaker or fuse box before installing. When the service disconnecting means cannot be sure to leave these instructions for future reference. • Skill level - Installation work and electrical wiring must always be done by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. D. Installation of this vent hood requires...
Use and Care Manual
Page 10
... air flow, noise and energy use less than recommended. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with existing ducts may not achieve their rated air flow. If you do not have existing ductwork, skip to the outside. The venting system must be vented mode to the outside wall. This hood can reduce energy loss and inhibit mold growth. Duct length The ducting...
... air flow, noise and energy use less than recommended. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with existing ducts may not achieve their rated air flow. If you do not have existing ductwork, skip to the outside. The venting system must be vented mode to the outside wall. This hood can reduce energy loss and inhibit mold growth. Duct length The ducting...
Use and Care Manual
Page 11
It can be vented to the lowest part of the range or cooktop, but it may not be smaller. • Installation height should be measured from the cooking surface to the outdoors, or it can be installed onto a cabinet. This hood must be installed for recirculating operation. 49-80783-3 11 INSTALLATION PREPARATION Installation Preparation PRODUCT DIMENSIONS 12" MOUNTING SPACE 5 1»2" 20" X *Controls may vary Size 24" 30" 36" X 23 15...
It can be vented to the lowest part of the range or cooktop, but it may not be smaller. • Installation height should be measured from the cooking surface to the outdoors, or it can be installed onto a cabinet. This hood must be installed for recirculating operation. 49-80783-3 11 INSTALLATION PREPARATION Installation Preparation PRODUCT DIMENSIONS 12" MOUNTING SPACE 5 1»2" 20" X *Controls may vary Size 24" 30" 36" X 23 15...
Use and Care Manual
Page 12
... listed wire nuts Torx 10, 15, 20 driver Strain relief for junction box Charcoal Filter (required for some models in recirculation mode) Aluminized Duct tape PLAN THE INSTALLATION CAUTION To reduce risk of the hood. In a ducted application, this range hood can be used and carefully calculate all measurements. NOTE: Before making any cuts or holes for external venting only) NOTE: This range hood can be sure to protect against sharp edges. • Remove...
... listed wire nuts Torx 10, 15, 20 driver Strain relief for junction box Charcoal Filter (required for some models in recirculation mode) Aluminized Duct tape PLAN THE INSTALLATION CAUTION To reduce risk of the hood. In a ducted application, this range hood can be used and carefully calculate all measurements. NOTE: Before making any cuts or holes for external venting only) NOTE: This range hood can be sure to protect against sharp edges. • Remove...
Use and Care Manual
Page 14
... elbows. 2. Follow National Electrical Codes or prevailing local codes and ordinances. Remove house fuse or open circuit breaker before proceeding. • Route house wiring as close to the installation location as possible in this appliance. Purchase the wall or roof cap and any transition and length of duct needed in a risk of the power supply connection is properly grounded. 14 49-80783-3 The charcoal filter is necessary for available makeup air...
... elbows. 2. Follow National Electrical Codes or prevailing local codes and ordinances. Remove house fuse or open circuit breaker before proceeding. • Route house wiring as close to the installation location as possible in this appliance. Purchase the wall or roof cap and any transition and length of duct needed in a risk of the power supply connection is properly grounded. 14 49-80783-3 The charcoal filter is necessary for available makeup air...
Use and Care Manual
Page 15
... the range hood, attach the mounting bracket as shown below , the mounting bracket may be used for cabinets with a recessed bottom. C Outside rear exhaust (Horizontal duct-3 1»4" x 10" Rectangular) D Recirculating (Unit is correct. Brackets should be used on the right side of the cabinet and the bracket labeled "L" will be used on left side of cabinet. Push against the back wall and flush with the bottom of the cabinet. Otherwise, the hood must mount directly...
... the range hood, attach the mounting bracket as shown below , the mounting bracket may be used for cabinets with a recessed bottom. C Outside rear exhaust (Horizontal duct-3 1»4" x 10" Rectangular) D Recirculating (Unit is correct. Brackets should be used on the right side of the cabinet and the bracket labeled "L" will be used on left side of cabinet. Push against the back wall and flush with the bottom of the cabinet. Otherwise, the hood must mount directly...
Use and Care Manual
Page 16
... (in wall) Center line 16 49-80783-3 INSTALLATION PREPARATION Installation Preparation 2 PREPARING MOUNTING (Cont) B To install to that section: A Outside top exhaust (Vertical duct-3 1»4" x 10" Rectangular) • Use the diagram as a template and mark the locations on the cabinet for ductwork and electrical wiring. Drive the 4 (F) screws partway into the bottom of cabinet Use the diagram or hood as a template and mark the locations on the cabinet for ductwork and electrical wiring.
... (in wall) Center line 16 49-80783-3 INSTALLATION PREPARATION Installation Preparation 2 PREPARING MOUNTING (Cont) B To install to that section: A Outside top exhaust (Vertical duct-3 1»4" x 10" Rectangular) • Use the diagram as a template and mark the locations on the cabinet for ductwork and electrical wiring. Drive the 4 (F) screws partway into the bottom of cabinet Use the diagram or hood as a template and mark the locations on the cabinet for ductwork and electrical wiring.
Use and Care Manual
Page 17
.... Make sure damper pivot is to top/back edge of the hood. 3 1»4" x 10" Rectangular vertical discharge. Using a flat blade screwdriver, remove the appropriate duct knockout(s) from inside the hood. Remove top rectangular duct knockout only. 7" Round vertical discharge. Set the junction box and mounting screws aside. Tape 7RSEDFN edge Damper (vertical discharge position shown) Rectangular Ducting 7" round exhaust adaptor 49-80783-3 Round Ducting 17 Remove rear rectangular duct knockout only. Remove semi...
.... Make sure damper pivot is to top/back edge of the hood. 3 1»4" x 10" Rectangular vertical discharge. Using a flat blade screwdriver, remove the appropriate duct knockout(s) from inside the hood. Remove top rectangular duct knockout only. 7" Round vertical discharge. Set the junction box and mounting screws aside. Tape 7RSEDFN edge Damper (vertical discharge position shown) Rectangular Ducting 7" round exhaust adaptor 49-80783-3 Round Ducting 17 Remove rear rectangular duct knockout only. Remove semi...
Use and Care Manual
Page 18
Mounting screw (4) Keyhole (4) 18 49-80783-3 INSTALLATION PREPARATION Installation Instructions 8 FOR VENTED INSTALLATIONS On Some Models: Install with vented mode deflector part. 10 MOUNT THE UTC Place the hood onto the partially installed screws using the keyholes and slide the hood back into position and feed the house wiring through the wiring knockout. 11 SECURE HOOD Tighten the mounting screws. Be sure the screw heads are in the narrow neck of the keyhole slot. On Some Models: Install vented mode deflector part. 2 1 9 FEED IN WIRES Lift the hood into position.
Mounting screw (4) Keyhole (4) 18 49-80783-3 INSTALLATION PREPARATION Installation Instructions 8 FOR VENTED INSTALLATIONS On Some Models: Install with vented mode deflector part. 10 MOUNT THE UTC Place the hood onto the partially installed screws using the keyholes and slide the hood back into position and feed the house wiring through the wiring knockout. 11 SECURE HOOD Tighten the mounting screws. Be sure the screw heads are in the narrow neck of the keyhole slot. On Some Models: Install vented mode deflector part. 2 1 9 FEED IN WIRES Lift the hood into position.
Use and Care Manual
Page 19
... lead of the power supply to the range hood. For vented installation: Install the grease filters. 49-80783-3 19 Connect the green (D) ground wire under the green grounding screw. 2. Replace the grease filters. For ducted installation: Install the grease filters. 13 ELECTRICAL CONNECTION 1. Replace the junction box cover. A D 2. For recirculation: Install the charcoal filter. 2. C B On Some Models: 1. For recirculation: Place the charcoal filter (not included) in place and mount using 2 screws. Use duct tape to hood. Connect the Power Supply Cable to the black...
... lead of the power supply to the range hood. For vented installation: Install the grease filters. 49-80783-3 19 Connect the green (D) ground wire under the green grounding screw. 2. Replace the grease filters. For ducted installation: Install the grease filters. 13 ELECTRICAL CONNECTION 1. Replace the junction box cover. A D 2. For recirculation: Install the charcoal filter. 2. C B On Some Models: 1. For recirculation: Place the charcoal filter (not included) in place and mount using 2 screws. Use duct tape to hood. Connect the Power Supply Cable to the black...
Use and Care Manual
Page 20
... Cleaning of the Vent Hood. 20 49-80783-3 See the mini manual for service. Wait 30 seconds to allow controls to the hood by resetting the circuit breaker. See Care and Cleaning of the Vent Hood. What To Do Replace fuse or reset circuit breaker. The blower connector is blocking the vent. Damper blade on wall or roof cap may require or strongly advise the use of transitions and elbows. Remove the filters and look up at the blower. Sufficient makeup (replacement) air...
... Cleaning of the Vent Hood. 20 49-80783-3 See the mini manual for service. Wait 30 seconds to allow controls to the hood by resetting the circuit breaker. See Care and Cleaning of the Vent Hood. What To Do Replace fuse or reset circuit breaker. The blower connector is blocking the vent. Damper blade on wall or roof cap may require or strongly advise the use of transitions and elbows. Remove the filters and look up at the blower. Sufficient makeup (replacement) air...
Use and Care Manual
Page 21
..., free of charge, all labor and related service costs to replace the defective part. This warranty gives you specific legal rights, and you may require the use the product. Ŷ Improper installation, delivery, or maintenance. Ŷ Failure of the product if it online anytime at www.geappliances.com/service_and_support/shop-for a particular purpose, are limited to one -year warranty, GE Appliances will replace...
..., free of charge, all labor and related service costs to replace the defective part. This warranty gives you specific legal rights, and you may require the use the product. Ŷ Improper installation, delivery, or maintenance. Ŷ Failure of the product if it online anytime at www.geappliances.com/service_and_support/shop-for a particular purpose, are limited to one -year warranty, GE Appliances will replace...
Quick Specs
Page 1
... Laboratories Specification Revised 5/16 Includes rectangular damper. 7/8" 7/8" 3-1/4" 10" 30" UNDER-THE-COUNTER HOOD INSTALLATION DIMENSIONS For answers to 3-1/4" x 10" rectangular duct. JXHC1 Cord Kit: Allows a receptacle in the cabinet over the range to accommodate either an over-the- 5-1/2" JVX3300EJ/SJ GE Appliances 30" Under the Cabinet Hood DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES) WB02X11537 replacement grease filter and WB02X11000 replacement charcoal filter are available for current dimensional data. Call toll-free 800...
... Laboratories Specification Revised 5/16 Includes rectangular damper. 7/8" 7/8" 3-1/4" 10" 30" UNDER-THE-COUNTER HOOD INSTALLATION DIMENSIONS For answers to 3-1/4" x 10" rectangular duct. JXHC1 Cord Kit: Allows a receptacle in the cabinet over the range to accommodate either an over-the- 5-1/2" JVX3300EJ/SJ GE Appliances 30" Under the Cabinet Hood DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES) WB02X11537 replacement grease filter and WB02X11000 replacement charcoal filter are available for current dimensional data. Call toll-free 800...
Quick Specs
Page 2
... Under the Cabinet Hood FEATURES AND BENEFITS Easy installation - 10 minutes or less by one person Two-speed, 200-CFM venting system - Filters grease and is dishwasher-safe Model JVX3300SJSS - Stainless steel Model JVX3300EJES - Slate JVX3300SJSS Light On O Power Hi Lo O CFM/SONES RATINGS Exhaust High Speed (HS) Exhaust Working Speed (WS) 200/6.0 100/1.5 Specification Revised 5/16 Select recirculating or external venting Vertical and rear exhaust - Enjoy easy access to hood interior Dishwasher safe filter - Removes smoke, grease, odors and moisture Front controls - Enjoy easy...
... Under the Cabinet Hood FEATURES AND BENEFITS Easy installation - 10 minutes or less by one person Two-speed, 200-CFM venting system - Filters grease and is dishwasher-safe Model JVX3300SJSS - Stainless steel Model JVX3300EJES - Slate JVX3300SJSS Light On O Power Hi Lo O CFM/SONES RATINGS Exhaust High Speed (HS) Exhaust Working Speed (WS) 200/6.0 100/1.5 Specification Revised 5/16 Select recirculating or external venting Vertical and rear exhaust - Enjoy easy access to hood interior Dishwasher safe filter - Removes smoke, grease, odors and moisture Front controls - Enjoy easy...