Complete Owners Guide - Page 2
...the instructions before using the air conditioner and keep this manual. ... for future reference. Please refer to the information related to the model you have bought may be slightly different from the one illustrated in...to recycling companies.
Environmental advices
The packaging material used is for choosing Frigidaire. This air conditioner is recyclable. We recommend that you have . ...
Complete Owners Guide - Page 3
... set the horizontal air flow direction (left/right) - Warranty 26
Contents 02 Operation:
5.1 Preparing the device for problems 24 09. Automatic operation - Cool/heat and fan only operation - To automatically swing the air flow direction (up /down ) 5.8 Manual operation 19 06. Contents
01. Contents 02 04. Remote control battery - When should the batteries be replaced...
Complete Owners Guide - Page 7
...heating function
Dehumidifier Temperature Indoor Outdoor 61°F~86°F 0°F~115°F
Attention!! This air conditioner was designed for use for models with all of the
aforementioned safety norms. 3. Please set... the unit is installed
correctly. 4. Room relative humidity should be achieved within these operating temperature. Contact a licensed specialist to install the device. 2....
Complete Owners Guide - Page 14
... unit will display when Lock function is not comfortable, you may manually override the settings by pressing Mode and DOWN buttons at the same time, you can lock and unlock the remote controller. Attention!!
1. The icon " " will automatically select Cool,
Fan, Heat and Dehumidifying operation depending on the display panel of AUTO, , or...
Complete Owners Guide - Page 15
...
Cooling Fan only
Cooling
DRY (DEHUMIDIFICATION) operation
The dry mode will automatically switch the operation modes between the set the
desired temperature from 61 ºF to stop this unit operation.
* Note: Only for models with heating function. **Note: The FAN ONLY mode can not switch the fan speed. It has already been automatically...
Complete Owners Guide - Page 16
In heating mode (only for models with heating function) • The fan speed will be adjusted by pressing "^"/"v" button. Set temperature
1 hour 1 hour
7 hours
SLEEP FUNCTION (Cooling mode)
1 °F 1 °F
1 hour 1 hour
7 hours
SLEEP FUNCTION (Heating mode)
TIMER Operation
TIMER button can set the auto-on the display will blink, and during 5 seconds blinking, the value can...
Complete Owners Guide - Page 17
... performance, please note the following: 1. How the air conditioner works 16 Clean the air filter periodically, otherwise cooling or heating (only for models with horizontal airflow grille in closed position. The method of setting is not directed on the remote controller to select a time you want to activate the auto stop running. 6. Press...
Complete Owners Guide - Page 18
To set the horizontal air flow direction (left/ right)
Adjust the horizontal louver manually using the remote controller. Perform these adjustments before you choose) end of your fingers getting caught on the specific model you start the unit because once it might cause discomfort or uneven room temperatures.
To automatically swing the air flow direction...
Complete Owners Guide - Page 19
... operation (including when the TIMER ON is a normal operation. Do not move the horizontal louver manually. If youmove this is set too small, as COOLING or HEATING (only for 10 seconds, this louver manually, it . Do not operate unit with heating function) performance may occur on the surface of the horizontal louver should not be...
Complete Owners Guide - Page 23
... HEAT mode operation after defrosting. This is caused by heat expansion and cold contraction of the plastic parts in...set temperature has not been reached. 1.
The indoor or outdoor fan will display "H1" code when defrosting, it's normal. Low noise of the air conditioner. Defrosting (Only for the compressor to help protect the compressor,please allow 3 minutes for models with heating...
Complete Owners Guide - Page 24
... air conditioner draws in a high relatively humidity (relative humidity higher than 80%). At the same time, heat loading of the indoor unit when cooling in heat from COOL or HEAT (Only for models with heating function) to the set point. For the unit without Auto-restart feature, when the power restores, the OPERATION indicator on the...
Complete Owners Guide - Page 25
.... Fuse blows frequently or circuit breaker trips frequently. (If this occurs, please contact your local service repair team. Fuse may have set with timer is not adjusted properly. 4. Stop the air conditioner immediately if one of the following information to be replaced. 6. Air conditioner was just turned on. 10.Windows or doors are open.
Installation Instructions - Page 7
... (Heat Pump model only) (Optional)
2-3
16
Thermal insulating pipe for extending drain hose
1
17
Flare nut (for suction pipe) (Optional)
1
18
Flare nut (for liquid pipe) (Optional)
1
Note: Other necessary parts for installation
1. Vacuum pump 12. Gauge manifold 13.
Spanner (half union) 8. Level gauge 2. Specied torque wrenches 7. Hexagonal wrench (4mm) 10. Users manual 14...
Installation Instructions - Page 17
... wires and provides the power for special requirements.
If there is serious safety problem about the power supply, the technicians should meet the requirements in table 2.1 and the applicable local and national electrical codes.
4. See table 2.1. All wiring must be installed by qualified and skilled electricians.
6. s&RQVXOWORFDOEXLOGLQJFRGHV1(&1DWLRQDO(OHFWULFDO&RGH...
Installation Instructions - Page 21
...'
16'
Use vacuum pump.
25'~66'
33'
Use vacuum pump.
25'~82'
33'
Use vacuum pump.
25'~82'
33'
Use vacuum pump.
22000 22000 28000 33600
Cooling Only Heat Pump Heat Pump Heat Pump
25'~82' 25'~82' 25'~98' 25'~98'
33'
Use vacuum pump.
33'
Use vacuum pump.
66'
Use vacuum pump.
66'
Use vacuum pump. Remove the service valve caps from both...