FE Ti10-25-Tir-1 Users Manual
Page 1
Printed in USA All product names are trademarks of their respective companies. Ti10, Ti25, TiR and TiR1 Thermal Imagers Users Manual PN 2803044 August 2007 © 2007 Fluke Corporation, All rights reserved.
Printed in USA All product names are trademarks of their respective companies. Ti10, Ti25, TiR and TiR1 Thermal Imagers Users Manual PN 2803044 August 2007 © 2007 Fluke Corporation, All rights reserved.
FE Ti10-25-Tir-1 Users Manual
Page 3
...Contacting Fluke 1 Safety Information 2 Unpacking the Imager 3 Charging the Battery 3 Turning the Imager On and Off 3 Features and Controls 3 Using the Menu 5 Changing the Displayed Language 5 Setting the Imager Clock 5 Setting the Date 6 Setting the Time 6 Focusing and Capturing an Image 6 Saving Imager Data 7 Adjusting the Thermal Image ...10 Setting IR Fusion® and PIP (Ti25 and TiR1 Only 10 Reviewing and Deleting Stored Images 10 Adding Voice Annotation to Saved Data (Ti25 and TiR1 Only 11 Listening to Voice Annotations (Ti25 and TiR1 Only 12 Changing the Temperature ...
...Contacting Fluke 1 Safety Information 2 Unpacking the Imager 3 Charging the Battery 3 Turning the Imager On and Off 3 Features and Controls 3 Using the Menu 5 Changing the Displayed Language 5 Setting the Imager Clock 5 Setting the Date 6 Setting the Time 6 Focusing and Capturing an Image 6 Saving Imager Data 7 Adjusting the Thermal Image ...10 Setting IR Fusion® and PIP (Ti25 and TiR1 Only 10 Reviewing and Deleting Stored Images 10 Adding Voice Annotation to Saved Data (Ti25 and TiR1 Only 11 Listening to Voice Annotations (Ti25 and TiR1 Only 12 Changing the Temperature ...
FE Ti10-25-Tir-1 Users Manual
Page 7
... saved images. Both thermal and visual images can be presented simultaneously as a full fusion (thermal displayed over visual) image or as a Picture-In-Picture (PIP) image. The thermal image temperature range starts at www.fluke.com To register your product, visit register.fluke.com 1 In addition to an SD Memory card. Introduction The Fluke Ti10, Ti25, TiR, and TiR1 Thermal Imagers (hereafter "the Imager") are...
... saved images. Both thermal and visual images can be presented simultaneously as a full fusion (thermal displayed over visual) image or as a Picture-In-Picture (PIP) image. The thermal image temperature range starts at www.fluke.com To register your product, visit register.fluke.com 1 In addition to an SD Memory card. Introduction The Fluke Ti10, Ti25, TiR, and TiR1 Thermal Imagers (hereafter "the Imager") are...
FE Ti10-25-Tir-1 Users Manual
Page 9
... the center softkey (a) for at least two hours. The Imager's battery condition is operating. To charge the Imager's battery: 1. Plug the battery charger's dc output into an ac wall outlet. 2. Thermal Imagers Unpacking the Imager Unpacking the Imager Carefully unpack the following items: • Ti10, Ti25, TiR or TiR1 Imager • AC Power Adapter/Charger • Rugged Carrying...
... the center softkey (a) for at least two hours. The Imager's battery condition is operating. To charge the Imager's battery: 1. Plug the battery charger's dc output into an ac wall outlet. 2. Thermal Imagers Unpacking the Imager Unpacking the Imager Carefully unpack the following items: • Ti10, Ti25, TiR or TiR1 Imager • AC Power Adapter/Charger • Rugged Carrying...
FE Ti10-25-Tir-1 Users Manual
Page 11
...Up or Down to move the cursor to set the units. Item 9 10 11 12 13 14 Thermal Imagers Using the Menu Table 2. Setting the Imager Clock The Imager has an internal real-time clock that softkey throughout all menu screens. The menu will disappear several seconds...Lens Cover Visual camera Thermal (IR) camera Focus control Trigger Using the Menu The menus, coupled with the three softkeys (c, a, and d), provide access for setting features (date, time, language, units, backlight and spot temperatures), thermal image display, and saving and viewing stored images. Press the softkey ...
...Up or Down to move the cursor to set the units. Item 9 10 11 12 13 14 Thermal Imagers Using the Menu Table 2. Setting the Imager Clock The Imager has an internal real-time clock that softkey throughout all menu screens. The menu will disappear several seconds...Lens Cover Visual camera Thermal (IR) camera Focus control Trigger Using the Menu The menus, coupled with the three softkeys (c, a, and d), provide access for setting features (date, time, language, units, backlight and spot temperatures), thermal image display, and saving and viewing stored images. Press the softkey ...
FE Ti10-25-Tir-1 Users Manual
Page 13
...display and bring up the Image Capture menu. 2. Saving Imager Data The Imager saves displayed data on the SD card. Point camera at the area of image parallax and minimum focus specifications, the minimum distance for operational details. Thermal Imagers Saving Imager Data Note Minimum focus distance ... the softkey labeled Settings allows modification of view. Adjusting the Thermal Image The Imager uses different colors or shades of gray to capture an image. Note When IR-Fusion® is properly focused, the images should be almost perfectly aligned. Refer to get a good ...
...display and bring up the Image Capture menu. 2. Saving Imager Data The Imager saves displayed data on the SD card. Point camera at the area of image parallax and minimum focus specifications, the minimum distance for operational details. Thermal Imagers Saving Imager Data Note Minimum focus distance ... the softkey labeled Settings allows modification of view. Adjusting the Thermal Image The Imager uses different colors or shades of gray to capture an image. Note When IR-Fusion® is properly focused, the images should be almost perfectly aligned. Refer to get a good ...
FE Ti10-25-Tir-1 Users Manual
Page 14
...over c. 2. Press the softkey labeled Up or Down to the list. Setting the Range Viewing temperature (level and span) is set the Imager to set the range, do the following: 1. Press the softkey labeled Manual to the selected palette. Press the softkey labeled Range. 3. ...Ironbow are available in all four Imagers. To set the Imager to manual ranging and press the softkey labeled Auto to display the available palette options. 3. Ti10, Ti25, TiR and TiR1 Users Manual Selecting a Palette The palette menu provides different thermal viewing patterns. Press the softkey labeled...
...over c. 2. Press the softkey labeled Up or Down to the list. Setting the Range Viewing temperature (level and span) is set the Imager to set the range, do the following: 1. Press the softkey labeled Manual to the selected palette. Press the softkey labeled Range. 3. ...Ironbow are available in all four Imagers. To set the Imager to manual ranging and press the softkey labeled Auto to display the available palette options. 3. Ti10, Ti25, TiR and TiR1 Users Manual Selecting a Palette The palette menu provides different thermal viewing patterns. Press the softkey labeled...
FE Ti10-25-Tir-1 Users Manual
Page 15
... span to higher temperatures or Down to move the span to set the level: 1. To set the Imager's range level. Press the softkey labeled Done to lower temperatures. 3. See Figure 1. Level Thermal Imagers Adjusting the Thermal Image Total Imager Range Span Figure 1. Range and Span Settings exj02.eps Setting the Level (Manual) When put into manual...
... span to higher temperatures or Down to move the span to set the level: 1. To set the Imager's range level. Press the softkey labeled Done to lower temperatures. 3. See Figure 1. Level Thermal Imagers Adjusting the Thermal Image Total Imager Range Span Figure 1. Range and Span Settings exj02.eps Setting the Level (Manual) When put into manual...
FE Ti10-25-Tir-1 Users Manual
Page 16
...Review. 10 Ti10, Ti25, TiR and TiR1 Users Manual 2. Press the softkey labeled Done to display a full infrared image (Full IR) or an infrared image surrounded by a visual light image (Picture-in-Picture / PIP). Press a until IRFusion appears over d. 2. In addition to setting the visual to thermal blending, the IR-...174; menu is used to one of three different levels of visible blending. 4. The bottom three settings have full screen IR with a thermal image is set the IR-Fusion® level and PIP display: 1. Press the softkey labeled Increase to widen the temperature span or Decrease to ...
...Review. 10 Ti10, Ti25, TiR and TiR1 Users Manual 2. Press the softkey labeled Done to display a full infrared image (Full IR) or an infrared image surrounded by a visual light image (Picture-in-Picture / PIP). Press a until IRFusion appears over d. 2. In addition to setting the visual to thermal blending, the IR-...174; menu is used to one of three different levels of visible blending. 4. The bottom three settings have full screen IR with a thermal image is set the IR-Fusion® level and PIP display: 1. Press the softkey labeled Increase to widen the temperature span or Decrease to ...
FE Ti10-25-Tir-1 Users Manual
Page 17
...Press the softkey labeled All Images. Press the softkey labeled Memory. 3. To keep the audio annotation, proceed to what was recorded. Once stored, the audio annotation can only be added to an image prior to Saved Data (Ti25 and TiR1 Only) 4. Thermal Imagers Adding Voice Annotation to storing... it. When an audio recording has been created for each image. 4. To delete a single Image from the SD card: 1. Adding Voice Annotation to ...
...Press the softkey labeled All Images. Press the softkey labeled Memory. 3. To keep the audio annotation, proceed to what was recorded. Once stored, the audio annotation can only be added to an image prior to Saved Data (Ti25 and TiR1 Only) 4. Thermal Imagers Adding Voice Annotation to storing... it. When an audio recording has been created for each image. 4. To delete a single Image from the SD card: 1. Adding Voice Annotation to ...
FE Ti10-25-Tir-1 Users Manual
Page 19
...is easy to estimate the temperature of common materials: 1. Press the softkey labeled Table. 2. The emissivity value for some common materials. Thermal Imagers Setting Emissivity (Ti25 and TiR1 only) the object's surface. This estimate works for most surfaces but can be set directly as having low emissivity. To... to get a more accurate estimate of this topic is critical to be multiplied by directly entering a value or using the Imager. The TiR1 and Ti25 have emissivity that is available on the screen as painted metal, wood, water, skin, and cloth are efficient at radiating ...
...is easy to estimate the temperature of common materials: 1. Press the softkey labeled Table. 2. The emissivity value for some common materials. Thermal Imagers Setting Emissivity (Ti25 and TiR1 only) the object's surface. This estimate works for most surfaces but can be set directly as having low emissivity. To... to get a more accurate estimate of this topic is critical to be multiplied by directly entering a value or using the Imager. The TiR1 and Ti25 have emissivity that is available on the screen as painted metal, wood, water, skin, and cloth are efficient at radiating ...
FE Ti10-25-Tir-1 Users Manual
Page 20
...and remains valid when the Imager is supplied with the thermal imager. SmartView™ Software SmartView™ software is turned off and back on the Imager's SD card can be saved...the file format: 1. Setting File Format Data stored on . Visit the Fluke web site or contact Fluke to increment or decrement respectively the emissivity value displayed just above the softkey ...infrared storage (.is2) file format. Bitmap (.bmp) images can always be reviewed on the Imager's display. Press the softkey labeled File Format. 3. Ti10, Ti25, TiR and TiR1 Users Manual To set the emissivity...
...and remains valid when the Imager is supplied with the thermal imager. SmartView™ Software SmartView™ software is turned off and back on the Imager's SD card can be saved...the file format: 1. Setting File Format Data stored on . Visit the Fluke web site or contact Fluke to increment or decrement respectively the emissivity value displayed just above the softkey ...infrared storage (.is2) file format. Bitmap (.bmp) images can always be reviewed on the Imager's display. Press the softkey labeled File Format. 3. Ti10, Ti25, TiR and TiR1 Users Manual To set the emissivity...
FE Ti10-25-Tir-1 Users Manual
Page 21
Thermal Imagers Changing the SD Card Changing the SD Card To eject an SD card from the Imager, press in on the exposed edge of the slot. Note The SD Card can be inserted and removed while the Imager is in until Backlight appears over c. 2. To insert an SD card into the Imager...batteries Relative Humidity 10 to Auto-sensing or Full-Bright. Note To extend battery life, Auto-Sensing automatically adjusts backlight brightness based on the image (TiR1 and Ti25 only) 15 Push the card in operation. Setting the Backlight The backlight can be set to 90 % non-condensing Display 640 x ...
Thermal Imagers Changing the SD Card Changing the SD Card To eject an SD card from the Imager, press in on the exposed edge of the slot. Note The SD Card can be inserted and removed while the Imager is in until Backlight appears over c. 2. To insert an SD card into the Imager...batteries Relative Humidity 10 to Auto-sensing or Full-Bright. Note To extend battery life, Auto-Sensing automatically adjusts backlight brightness based on the image (TiR1 and Ti25 only) 15 Push the card in operation. Setting the Backlight The backlight can be set to 90 % non-condensing Display 640 x ...
FE Ti10-25-Tir-1 Users Manual
Page 23
Thermal Imagers Detailed Specifications Detailed Specifications Temperature Measurements Temperature Range (not calibrated below -10 °C) TiR and TiR1 20 °C to +100 °C Ti10 20 °C to +250 °C Ti25 20 °C to +350 °C Accuracy TiR and Ti10 5 °C or 5 % (whichever is greater) TiR1 and Ti25... Modes Smooth Auto-Scaling and Manual Scaling On-screen Emissivity Correction Ti25 and TiR1 Only) Imaging Performance Field of View 23 ° x 17 ° Spatial Resolution (IFOV 2.5 mRad Minimum Focus Distance Thermal Lens 15 cm (approx. 6 in) Visible (Visual) Light...
Thermal Imagers Detailed Specifications Detailed Specifications Temperature Measurements Temperature Range (not calibrated below -10 °C) TiR and TiR1 20 °C to +100 °C Ti10 20 °C to +250 °C Ti25 20 °C to +350 °C Accuracy TiR and Ti10 5 °C or 5 % (whichever is greater) TiR1 and Ti25... Modes Smooth Auto-Scaling and Manual Scaling On-screen Emissivity Correction Ti25 and TiR1 Only) Imaging Performance Field of View 23 ° x 17 ° Spatial Resolution (IFOV 2.5 mRad Minimum Focus Distance Thermal Lens 15 cm (approx. 6 in) Visible (Visual) Light...
Fluke Ti10 and Ti25 Thermal Imager Datasheet
Page 1
Fluke Ti25 and Ti10 Thermal Imagers The ultimate tools for almost any application and budget what you expect from Fluke Models for troubleshooting and maintenance IR-Fusion® Technology- infrared and visual images fused together makes infrared easy to understand Rugged, reliable, easy to use . . . NEW!
Fluke Ti25 and Ti10 Thermal Imagers The ultimate tools for almost any application and budget what you expect from Fluke Models for troubleshooting and maintenance IR-Fusion® Technology- infrared and visual images fused together makes infrared easy to understand Rugged, reliable, easy to use . . . NEW!
Fluke Ti10 and Ti25 Thermal Imager Datasheet
Page 2
...modes Identify problems quickly using different on page 7 Thermal imaging is a non-contact technology that measures infrared wavelengths to determine temperatures from Fluke links the infrared image to full visual (visible light) image automatically. IR/Color Alarm Displays only temperatures falling... image. Images enhanced with surroundings. IR-Fusion links the two images together to be imminent. the data behind the picture All Fluke thermal imagers are no longer enough. Automatic Blend A blend of thermal imaging Applications Temperature changes can be made imagers ...
...modes Identify problems quickly using different on page 7 Thermal imaging is a non-contact technology that measures infrared wavelengths to determine temperatures from Fluke links the infrared image to full visual (visible light) image automatically. IR/Color Alarm Displays only temperatures falling... image. Images enhanced with surroundings. IR-Fusion links the two images together to be imminent. the data behind the picture All Fluke thermal imagers are no longer enough. Automatic Blend A blend of thermal imaging Applications Temperature changes can be made imagers ...
Fluke Ti10 and Ti25 Thermal Imager Datasheet
Page 3
The perfect thermal imagers for everyday troubleshooting The Fluke Ti25 and Ti10 are saved along with individual images for future reference (Ti25 only) • Store more than 3,000 screen images (.bmp format) for easy reporting direct into the camera. simply navigate with update ... °F), and the Ti25 measures up to 350 ºC (662 °F) • Delivers the clear, crisp images needed to use ) Fluke SmartViewTM software is stored on included 2 GB SD memory card. Voice annotations can be recorded with each Fluke thermal imager. • Powerful, modular...
The perfect thermal imagers for everyday troubleshooting The Fluke Ti25 and Ti10 are saved along with individual images for future reference (Ti25 only) • Store more than 3,000 screen images (.bmp format) for easy reporting direct into the camera. simply navigate with update ... °F), and the Ti25 measures up to 350 ºC (662 °F) • Delivers the clear, crisp images needed to use ) Fluke SmartViewTM software is stored on included 2 GB SD memory card. Voice annotations can be recorded with each Fluke thermal imager. • Powerful, modular...
Fluke Ti10 and Ti25 Thermal Imager Datasheet
Page 4
... dust resistant Two meter (6.5 feet) drop test Protective lens cover Weight (including battery) Imager size (HxWxD) Other Warranty EN 61010-1 2nd edition and EN61326-1 Fluke Ti25 Fluke Ti10 23° horizontal x 17° vertical Thermal lens: 15 cm (approx. 6 in), Visible (visual) light lens: 46 cm ...(approx. 18 in an image. It basically is the maximum resolution of the image and is described with each measurement....
... dust resistant Two meter (6.5 feet) drop test Protective lens cover Weight (including battery) Imager size (HxWxD) Other Warranty EN 61010-1 2nd edition and EN61326-1 Fluke Ti25 Fluke Ti10 23° horizontal x 17° vertical Thermal lens: 15 cm (approx. 6 in), Visible (visual) light lens: 46 cm ...(approx. 18 in an image. It basically is the maximum resolution of the image and is described with each measurement....
Fluke Ti10 and Ti25 Thermal Imager Datasheet
Page 5
... and power quality troubleshooting tools for left or right handed user • Internal rechargeable battery • AC charger/power supply Ordering Information FLUKE-TI25 Thermal Imager FLUKE-TI10 Thermal Imager Fluke 337 True-rms Clamp Meter Fluke 771 Milliamp Process Clamp Meter To find out more information call 1-800-760-4523. PO Box 1186, 5602 BD Eindhoven, The Netherlands...
... and power quality troubleshooting tools for left or right handed user • Internal rechargeable battery • AC charger/power supply Ordering Information FLUKE-TI25 Thermal Imager FLUKE-TI10 Thermal Imager Fluke 337 True-rms Clamp Meter Fluke 771 Milliamp Process Clamp Meter To find out more information call 1-800-760-4523. PO Box 1186, 5602 BD Eindhoven, The Netherlands...