Product Manual - Page 1
All product names are subject to change without notice. 87V MAX Digital Multimeter Users Manual
October 2019 Rev. 1, 2/20 © 2019-2020 Fluke Corporation. Specifications are trademarks of their respective companies. All rights reserved.
Product Manual - Page 2
...specifications, or normal wear and tear of purchase. To establish original ownership and prove date of any provision of this limitation of the DMM, Fluke will , at its option, repair... register your nearest Fluke authorized service center to obtain return authorization information, then send the product to that service center, with a description of repair/replacement parts if the product purchased ...
Product Manual - Page 4
87V MAX Users Manual
How to Use Conductance for High Resistance or Leakage Tests 17 Capacitance ...Relative Mode...31 Maintenance ...32 General Maintenance 32 Fuse Test ...32 How to Replace the Batteries 33 How to Replace the Fuses 34 Service and Parts ...34 General Specifications 38 Detailed Specifications 40 AC Voltage...40 DC Voltage, Conductance, and Resistance 41 Temperature ...42 AC...
Product Manual - Page 12
The continuity beeper is 30 V or greater (ac or dc), Also appears in cal, Hz, and duty cycle modes.
Appears if the input voltage is on.
See Low-pass Filter. 87V MAX Users Manual
Number
Figure 1. Trig±
Positive or negative slope indicator for the analog...
Product Manual - Page 13
...
°C, °F
610000 mV
HiRes
Auto
Manual
Indication
Degrees Celsius, Degrees Fahrenheit
Displays selected range
High resolution (Hi Res) mode... Bargraph. In normal operation 0 (zero) is relative to possible electric shock or personal injury,
replace the battery as soon as described under "Zoom Mode".
7 A, μA, mA V, mV
...
Product Manual - Page 14
...model...61509;
Invalid EEPROM data.
Have the Meter serviced.
W Test lead ...set to the correct current position, the beeper warns you by making a chirping sound and the display flashes This warning is intended to stop you from attempting to the terminal
being tested. Invalid calibration data. 87V MAX Users Manual
Table 4. Error Messages
Replace...
Product Manual - Page 16
87V MAX Users Manual
How to Make Measurements
The following sections describe how to make measurements with no dc
offset) such as square waves, triangle waves, and
V
staircase waves. ...
Product Manual - Page 17
Note the ac voltage range, then manually select a dc voltage range equal to activate the low-pass filter mode (). When...8226; AC current: below 3 % of the dc measurement by inverters and variable frequency motor drives.
11 In most cases, the error is negligible (0.1 % or less) if the circuit impedance is equipped with reduced accuracy to Make Measurements Low-Pass Filter
The Meter is...
Product Manual - Page 24
... on the capacitor being tested, the display shows "diSC".
18
Select Capacitance
+
gaq104.emf
Figure 6. Capacitance Measurements To measure capacitance, set up the Meter as shown in Figure 6. 87V MAX Users Manual
Capacitance Measurements
XW Warning To prevent possible electrical shock, fire, or personal injury, disconnect power and discharge all high-voltage...
Product Manual - Page 30
... a reading seems to Figure 9 under
"Duty Cycle"). In general, the lowest frequency displayed is updated at the left side of the display (refer to be a multiple of what you expect, the... a higher voltage range might solve this problem by counting the number of times the signal crosses a threshold level each second. 87V MAX Users Manual
Frequency Measurements
The Meter measures the frequency ...
Product Manual - Page 32
87V MAX Users Manual
Duty Cycle Measurements
Duty cycle (or duty factor) is the percentage of logic and switching signals. ...in multiple triggering. (Normally, a distortion-free signal can be checked by pulses of Duty Cycle Measurements
26 To measure duty cycle, set up to ten times the amplitude of the selected voltage range.)
If a duty cycle reading is above or below a trigger level during...
Product Manual - Page 34
... component until the display reads zero. If an overange symbol ( )
28
lights, press twice to set the Meter to the desired
function, short the test leads together, press ; then
connect the leads to enter the ...
2. Select the relative mode by a factor of center. 87V MAX Users Manual
Zoom Mode (Power Up Option Only)
To use the Rel Zoom Bargraph:
1.
Product Manual - Page 38
... voltage exposure is possible.
• Use only specified replacement parts.
• Have an approved technician repair the Product. The resistance value should be in the display. 87V MAX Users Manual
Maintenance
XWWarning To prevent possible electrical shock, fire, or... the other than those shown, have the Meter serviced. If appears in Figure 10, with a damp cloth and mild detergent.
Product Manual - Page 40
... properly installed around the outside edge of its bracket ().
34
6. Secure the door with the outline on the case bottom and lowering the door into the fuse compartment.
8. Refer to step 2 under each fuse.
7. For correct placement of the Meter. Service and Parts
If the Meter fails, check the battery and fuses. Replacement parts...
Product Manual - Page 42
Replacement Parts Description
Battery, AA 1.5 V Fuse, 0.440 A, 1000 V, FAST Fuse, 11 A, 1000 V, FAST Fuse Access Door Screw Gasket, Battery Door Fuse Cap Holster Battery Door Alligator Clips Test Leads Integrated DMM Temperature Probe Quick Reference Guide Safety Information
Qty.
3 1 1 1 6 1 1 1 1 1 (set of 2) 1 (set of 2) 1 1 1
Fluke Part or Model Number 376756 943121 803293 3400480 3861068 ...
Fluke FLK-87-VMAX CAL Reviews
Do you have an experience with the Fluke FLK-87-VMAX CAL that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.
Earn 750 points for your review!