Fluke 8808A Digital Multimeter Datasheet
Page 1
...by today's applications. The pass/fail indicators take the guesswork out of 0.01 %. Fluke 8808A Digital Multimeter Extended Specifications Making measurements is as simple as pushing a button The Fluke 8808A 5.5 digit multimeter has a broad range of functions, measuring volts, ohms and amps with pass/fail ... and range, test limits, or enter other parameters to follow complex work instruction sheets. Eliminate production mistakes The Fluke 8808A 5.5 digit multimeter dependably performs the most often extremely easy and fast to save the setup. It is remarkably easy to instrument...
...by today's applications. The pass/fail indicators take the guesswork out of 0.01 %. Fluke 8808A Digital Multimeter Extended Specifications Making measurements is as simple as pushing a button The Fluke 8808A 5.5 digit multimeter has a broad range of functions, measuring volts, ohms and amps with pass/fail ... and range, test limits, or enter other parameters to follow complex work instruction sheets. Eliminate production mistakes The Fluke 8808A 5.5 digit multimeter dependably performs the most often extremely easy and fast to save the setup. It is remarkably easy to instrument...
Fluke 8808A Digital Multimeter Datasheet
Page 2
8808A Specifications Voltage 100V Setting 90 V to 110 V 120V Setting 108 V to 132 V 220V Setting 198 V to 242 V 240V Setting 216 V to 264 V Frequency 47 Hz to full uncertainty specifications Relative Humidity (non-condensing) Operating Uncontrolled (< 10°C) Power Consumption 15 VA peak (10 W average) Dimensions Height 88 mm (3.46 in) Width 217 mm (8.56 in) Depth 297 mm (11.7 in) Weight 2.1 kg (4.6 Ibs) Display Vacuum Fluorescent Display, segment Environment Temperature Operating 0 rC to 50 rC Storage 40 rC to 70 rC Warm Up hour to 440 Hz.
8808A Specifications Voltage 100V Setting 90 V to 110 V 120V Setting 108 V to 132 V 220V Setting 198 V to 242 V 240V Setting 216 V to 264 V Frequency 47 Hz to full uncertainty specifications Relative Humidity (non-condensing) Operating Uncontrolled (< 10°C) Power Consumption 15 VA peak (10 W average) Dimensions Height 88 mm (3.46 in) Width 217 mm (8.56 in) Depth 297 mm (11.7 in) Weight 2.1 kg (4.6 Ibs) Display Vacuum Fluorescent Display, segment Environment Temperature Operating 0 rC to 50 rC Storage 40 rC to 70 rC Warm Up hour to 440 Hz.
Fluke 8808A Digital Multimeter Datasheet
Page 3
... settling times are affected by source impedance, cable dielectric characteristics, and input signal changes Input Characteristics Range Full-Scale (5-1/2 Digits) Slow Resolution Medium Input Impedance Fast 200 mV 2 V 20 V 200 V 1000 V 199.999 mV 1.99999 ... - 28 °C 0.0015 + 0.0005 0.001 + 0.0005 0.0020 + 0.0005 0.0015 + 0.0005 0.0015 + 0.0005 2 Fluke Corporation 8808A Fluke 8808A Digital Multimeter Extended Specifications Fluke Corporation 3 DC Voltage Specifications Maximum Input 1000 V on any range. Common Mode Rejection 120 dB at 50 or 60 Hz ധ0.1㧑...
... settling times are affected by source impedance, cable dielectric characteristics, and input signal changes Input Characteristics Range Full-Scale (5-1/2 Digits) Slow Resolution Medium Input Impedance Fast 200 mV 2 V 20 V 200 V 1000 V 199.999 mV 1.99999 ... - 28 °C 0.0015 + 0.0005 0.001 + 0.0005 0.0020 + 0.0005 0.0015 + 0.0005 0.0015 + 0.0005 2 Fluke Corporation 8808A Fluke 8808A Digital Multimeter Extended Specifications Fluke Corporation 3 DC Voltage Specifications Maximum Input 1000 V on any range. Common Mode Rejection 120 dB at 50 or 60 Hz ധ0.1㧑...
Fluke 8808A Digital Multimeter Datasheet
Page 4
For inputs from 1 % to 5 % of range. AC Voltage Specifications AC Voltage specifications are for ac sinewave signals >5 % of range and
For inputs from 1 % to 5 % of range. AC Voltage Specifications AC Voltage specifications are for ac sinewave signals >5 % of range and
Fluke 8808A Digital Multimeter Datasheet
Page 5
... lead resistance. If REL is not used, add 0.2 for 200 uA and 2 mA range. Input Protection 1000 V on all ranges Input Characteristics Range Full-Scale (5-1/2 Digits) Slow Resolution Medium Current Source Fast 200 2 k 20 k 200 k 2 M 20 M 100 M 199.999 1.99999 k 19.9999 k 199.999 k 1.99999 M 19.9999...as ± (% of reading + % of range per lead for 4-wire resistance function, or 2-wire resistance with REL. Input Characteristics Range Full-Scale (5-1/2 Digits) Slow Resolution Medium Burden Voltage Fast 200 uA 2 mA 20 mA 200 mA 2 A 10 A 199.999 µA 1999.99 µA 19.9999 ...
... lead resistance. If REL is not used, add 0.2 for 200 uA and 2 mA range. Input Protection 1000 V on all ranges Input Characteristics Range Full-Scale (5-1/2 Digits) Slow Resolution Medium Current Source Fast 200 2 k 20 k 200 k 2 M 20 M 100 M 199.999 1.99999 k 19.9999 k 199.999 k 1.99999 M 19.9999...as ± (% of reading + % of range per lead for 4-wire resistance function, or 2-wire resistance with REL. Input Characteristics Range Full-Scale (5-1/2 Digits) Slow Resolution Medium Burden Voltage Fast 200 uA 2 mA 20 mA 200 mA 2 A 10 A 199.999 µA 1999.99 µA 19.9999 ...
Fluke 8808A Digital Multimeter Datasheet
Page 6
For inputs from 1 % to 5 % of range, add an additional error of 0.1 % of range. Input Protection Tool accessible 11 A / 1000 V and 440 mA / 1000 V fuses Measurement Method AC-coupled True RMS Shunt Resistance 0.01 for 2 A and 10 A ranges 1 for sinusoidal signals with amplitudes greater than 5 % of range. Accuracy Accuracy [1] Range 90 days 200 µA 2 mA 20 mA 200 mA 2 A 10 A 23 °C ± 5 °C 0.02 + 0.005 0.015 + 0.005 0.03 + 0.02 0.02 + 0.005 0.05 + 0.02 0.18 + 0.01 Notes: [1] Accuracy given as ± (% of reading + % of range) 1 year 23 °C ± 5 °C...
For inputs from 1 % to 5 % of range, add an additional error of 0.1 % of range. Input Protection Tool accessible 11 A / 1000 V and 440 mA / 1000 V fuses Measurement Method AC-coupled True RMS Shunt Resistance 0.01 for 2 A and 10 A ranges 1 for sinusoidal signals with amplitudes greater than 5 % of range. Accuracy Accuracy [1] Range 90 days 200 µA 2 mA 20 mA 200 mA 2 A 10 A 23 °C ± 5 °C 0.02 + 0.005 0.015 + 0.005 0.03 + 0.02 0.02 + 0.005 0.05 + 0.02 0.18 + 0.01 Notes: [1] Accuracy given as ± (% of reading + % of range) 1 year 23 °C ± 5 °C...
Fluke 8808A Digital Multimeter Datasheet
Page 7
... Rate Fast Maxiumum Reading 199.99 Resolution 0.01 Diode Test Response Time 100 samples/sec with audible tone Rate Fast Maxiumum Reading 1.9999 V Resolution 0.1 mV 6 Fluke Corporation 8808A Fluke 8808A Digital Multimeter Extended Specifications Fluke Corporation 7 Settling Considerations When measuring frequency after a dc offset voltage change, errors may occur.
... Rate Fast Maxiumum Reading 199.99 Resolution 0.01 Diode Test Response Time 100 samples/sec with audible tone Rate Fast Maxiumum Reading 1.9999 V Resolution 0.1 mV 6 Fluke Corporation 8808A Fluke 8808A Digital Multimeter Extended Specifications Fluke Corporation 7 Settling Considerations When measuring frequency after a dc offset voltage change, errors may occur.
Fluke 8808A Digital Multimeter Datasheet
Page 8
..., Italian, Simplified Chinese, Japanese), CD Rom with user manual (English). 8 Fluke Corporation Fluke 8808A Digital Multimeter Extended Specifications Fluke. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In...FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com ©2007 Fluke Corporation. Ordering information Models Description 8808A 120V 5.5 Digit Multimeter 8808A 220V 5.5 Digit Multimeter 8808A 100V 5.5 Digit Multimeter 8808A 240V 5.5 Digit Multimeter 8808A/SU includes 8808A...
..., Italian, Simplified Chinese, Japanese), CD Rom with user manual (English). 8 Fluke Corporation Fluke 8808A Digital Multimeter Extended Specifications Fluke. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In...FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com ©2007 Fluke Corporation. Ordering information Models Description 8808A 120V 5.5 Digit Multimeter 8808A 220V 5.5 Digit Multimeter 8808A 100V 5.5 Digit Multimeter 8808A 240V 5.5 Digit Multimeter 8808A/SU includes 8808A...
User Manual
Page 1
All product names are trademarks of their respective companies. ® 8808A Digital Multimeter Users Manual July 2007 © 2007 Fluke Corporation, All rights reserved.
All product names are trademarks of their respective companies. ® 8808A Digital Multimeter Users Manual July 2007 © 2007 Fluke Corporation, All rights reserved.
User Manual
Page 13
...Started Manual contains basic getting started information, contacting Fluke, unpacking, and general specifications. 1-3 1 Introduction and Specifications Introduction Introduction The Fluke 8808A Digital Multimeter (hereafter referred to determine if a measurement is a 5-1/2 digit dual-display multimeter designed for bench-top operation. Some features provided ... be displayed at the same time (e.g., ac voltage in one display and frequency in the other) • 5-1/2 digit resolution • True-rms ac • 2, 4 wire resistance or patented 2x4 wire resistance measurement technique •...
...Started Manual contains basic getting started information, contacting Fluke, unpacking, and general specifications. 1-3 1 Introduction and Specifications Introduction Introduction The Fluke 8808A Digital Multimeter (hereafter referred to determine if a measurement is a 5-1/2 digit dual-display multimeter designed for bench-top operation. Some features provided ... be displayed at the same time (e.g., ac voltage in one display and frequency in the other) • 5-1/2 digit resolution • True-rms ac • 2, 4 wire resistance or patented 2x4 wire resistance measurement technique •...
User Manual
Page 38
... level operation for Volts, 2-Wire and 4-Wire Ohms, and Hz measurements. 8808A Users Manual 1 2 3 4 2W/4W HI INPUT V SENSE 4W HI 1000V 750V MAX LO 200 mA MAX 1000 V 600 V CAT I CAT II 300 V 1V LO 500 Vpk 10 A MAX mA 10 A 8808A 5-1/2 DIGIT MULTIMETER 17 16 15 14 13 12 11 10 9 8 7 5 6 Figure...
... level operation for Volts, 2-Wire and 4-Wire Ohms, and Hz measurements. 8808A Users Manual 1 2 3 4 2W/4W HI INPUT V SENSE 4W HI 1000V 750V MAX LO 200 mA MAX 1000 V 600 V CAT I CAT II 300 V 1V LO 500 Vpk 10 A MAX mA 10 A 8808A 5-1/2 DIGIT MULTIMETER 17 16 15 14 13 12 11 10 9 8 7 5 6 Figure...
User Manual
Page 94
...this may be displayed as shown in fact positive when interpreted according to the test circuit as negative, it is the same for both circuits. 8808A Users Manual Primary Display REL HOLD Table A-2. If there is .010 ohm. Connect the leads to current flow convention. Turn the Meter on ...V SENSE 4W HI 1000V 750V MAX LO 200 mA MAX 1000 V 600 V CAT I CAT II 300 V 1V LO 500 Vpk 10 A MAX mA 10 A 8808A 5-1/2 DIGIT MULTIMETER Figure A-2. A-4 If you want to measure dc voltage on the front panel) is in Figure A-2 and read the measurements on the circumstances, this lead is...
...this may be displayed as shown in fact positive when interpreted according to the test circuit as negative, it is the same for both circuits. 8808A Users Manual Primary Display REL HOLD Table A-2. If there is .010 ohm. Connect the leads to current flow convention. Turn the Meter on ...V SENSE 4W HI 1000V 750V MAX LO 200 mA MAX 1000 V 600 V CAT I CAT II 300 V 1V LO 500 Vpk 10 A MAX mA 10 A 8808A 5-1/2 DIGIT MULTIMETER Figure A-2. A-4 If you want to measure dc voltage on the front panel) is in Figure A-2 and read the measurements on the circumstances, this lead is...