Calibration Guide - Page 1

® Model 787 ProcessMeter™ Calibration Manual PN 641891 May 1998 Rev. 1, 9/00 © 1998, 2000 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies.
Calibration Guide - Page 11

... in the 787 Users Manual. •...installed 9 V battery to possible electric shock or personal injury, replace...setting, and range for the battery eliminator, Calibration Module, and Calibration Software. • During Calibration, properly connect the Calibration Module to the ProcessMeter. • When servicing the ProcessMeter or the Calibration Module, use only specified replacement parts...
Calibration Guide - Page 12

...If the recommended equipment model is not available, in...Services CAT III Overvoltage (Installation) Category III, Pollution Degree 2 per IEC1010-1 refers to the manual. Model 787 Calibration Manual... perform the procedures in this manual showing a calibrator or digital...manual are explained in Table 1. Using unspecified equipment can be substituted as long as it meets the specifications...
Calibration Guide - Page 13

...with Fluke 5520A. Required Equipment and Software Equipment Minimum Specifications Recommended Model Calibration Source No Substitute Fluke Model 5500A...Manual Specifications Table 2. Fluke RS 43 486 (or later) IBM-compatible Calibration Software No Substitute Fluke MET/CAL Calibration Software 6.0 or later * HP 34401A may only be used in relative humidity to MET/CAL® manual set...
Calibration Guide - Page 14

...0.05 % + 2 0.2 % + 2 14 mV/mA 1.5 V/A 1 Specifications are valid from 5 % to 100 % of amplitude range. Specifications are valid from 5 % to 100 % of amplitude range. Input impedance: ... pF, ac-coupled. Input impedance: 10 MΩ (nominal), < 100 pF, ac-coupled. Model 787 Calibration Manual DC Millivolts Range (mV dc) Resolution 400.0 0. 1 mV Input impedance: 10 MΩ (...
Calibration Guide - Page 16

Model 787 Calibration Manual DC Current Output Source mode Simulate Mode Span: 0 mA or 4 mA to 20 mA, with overrange to 24 mA Accuracy: 0.05 % of span Compliance voltage: ...
Calibration Guide - Page 18

... the input terminal-end of the case top to the ProcessMeter, use ONLY specified replacement fuses with the amperage, voltage, interrupt and speed ratings shown in the OFF position...-blow fuse. (Fluke PN 943121.) Both fuses are closed and secured before replacing a fuse. Replace the fuse only with a separate 440 mA fuse. Model 787 Calibration Manual Checking and Replacing Fuses WWarning To ...
Calibration Guide - Page 20

... Module serviced. • Make sure that the HP 34401A may only be computer-automated (using Fluke's MET...Fluke's MET/CAL Calibration Software version 6.0 or later, a 787 Calibration Module, a Fluke 5500A or 5520A Calibrator, and either looks damaged. • Before proceeding with the 5520A Calibrator. Preparing to the MET/CAL manual set for the 787 ProcessMeter are available. Replace...
Calibration Guide - Page 21

... use the 787 ProcessMeter and the required equipment. Remove all connection diagrams for your instrument. If in doubt have the required equipment available. (See Table 2.) 2. Make sure the UUT has a fresh battery. If you have the ProcessMeter or Calibration Module serviced. • To avoid electrical shock, always place the calibrator in this manual. 3.
Calibration Guide - Page 28

... Standby (STBY) mode. 2. Using the Fluke 5440A-7002 low thermal leads, connect the...• SHIFT ENTER SETUP RESET NEW REF CE MEAS TC TRIG OUT MULT DIV x ÷ EDIT FIELD POWER I O Figure 8. Apply the calibrator resistance values in Table 7 in Figure 8. 6. Resistance Measurement Test Connections LT004F.EPS 20 Model 787 Calibration Manual Resistance Measurement Test ...
Calibration Guide - Page 30

... 4 5 6 n W ¡F k A ¡C p 1 2 3 M F +/ 0 • SHIFT ENTER SETUP RESET NEW REF CE MEAS TC TRIG OUT MULT DIV x ÷ EDIT FIELD POWER I O Figure 9. DC mV Measurement ...the UUT to the acceptable readings shown. 787 Range No Range Switching No Range Switching Table 8. Model 787 Calibration Manual DC Millivolts Measurement Test 1. Put the calibrator...
Calibration Guide - Page 34

...doubt have the ProcessMeter or Calibration Module serviced. • Make sure that the ...Fluke's MET/CAL Calibration Software and the 787 Calibration Module. contact Fluke to arrange to its specifications. Preparing for cracks, missing plastic, or damaged insulation. Replace... appears to operate abnormally. Model 787 Calibration Manual Calibration The 787 Processmeter is detected, do not...
Calibration Guide - Page 36

...rotary switch on the UUT to the Calibration Module, and plug the battery eliminator into the connector on the Fluke 5500A and 5520A calibrators. 6. Connect Calibration Module to the UUT. 5. Attach the battery door on the ... cable. (See Figure 13.) Note The calibration procedure does not support the UUT port on the battery door of the Calibration Module. 4. Model 787 Calibration Manual 3.
Calibration Guide - Page 37

... use the battery eliminator supplied with the calibration module (see Table 2). 787CAL 787 CALIBRATION MODULE SEE THE "787 CALIBRATION MANUAL" FOR OPERATION INSTRUCTIONS. DISCONNECT FROM MODEL 787 BATTERY CABLE BEFORE OPENING CALIBRATION MODULE CASE. THIS MODULE SHOULD BE OPERATED BY QUALIFIED SERVICE AND CALIBRATION PERSONNEL ONLY. WARNING TO AVOID ELECTRICAL SHOCK FASTEN BATTERY DOOR TO...
Calibration Guide - Page 38

... (STBY) before prompting you will be prompted to set Product Overview Manual Users Manual (CD-ROM) Calibration Manual (not shown) Fluke No. 614487 CG81G 943121 619962 619939 832246 824466 831933...Model 787 Calibration Manual Using the MET/CAL Calibration Software To calibrate the UUT using the MET/CAL Calibration Software, start MET/CAL and follow the prompts. Replaceable Parts When servicing...

Fluke 787-NIST Reviews

Do you have an experience with the Fluke 787-NIST that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Ask a New Question
Use the box below to post a new question about Fluke 787-NIST.
Manuals / Documents
Download any of our Fluke 787-NIST manuals for free!

We have the following 1 documents available for the Fluke 787-NIST:
  • Calibration Guide
Related Items

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 787-NIST manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 787-NIST user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.