Calibration Guide - Page 1
®
Model 787 ProcessMeter™
Calibration Manual
PN 641891 May 1998 Rev. 1, 9/00
© 1998, 2000 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies.
Calibration Guide - Page 11
... in the 787 Users Manual. •...installed 9 V battery
to possible electric shock or personal injury, replace...setting, and range for the battery eliminator, Calibration Module, and Calibration Software. • During Calibration, properly connect the Calibration Module to the ProcessMeter. • When servicing the ProcessMeter or the Calibration Module, use only specified replacement parts...
Calibration Guide - Page 12
...If the recommended equipment model is not available, in...Services
CAT III
Overvoltage (Installation) Category III, Pollution Degree 2 per IEC1010-1 refers to the manual.
Model 787 Calibration Manual... perform the procedures in this manual showing a calibrator or digital...manual are explained in Table 1. Using unspecified equipment can be substituted as long as it meets the specifications...
Calibration Guide - Page 13
...with Fluke 5520A. Required Equipment and Software
Equipment
Minimum Specifications
Recommended Model
Calibration Source
No Substitute
Fluke Model 5500A...Manual Specifications
Table 2.
Fluke RS 43 486 (or later) IBM-compatible
Calibration Software
No Substitute
Fluke MET/CAL Calibration Software 6.0 or later
* HP 34401A may only be used in relative humidity to MET/CAL® manual set...
Calibration Guide - Page 14
...0.05 % + 2 0.2 % + 2
14 mV/mA 1.5 V/A
1 Specifications are valid from 5 % to 100 % of amplitude range. Specifications are valid from 5 % to 100 % of amplitude range. Input impedance: ... pF, ac-coupled. Input impedance: 10 MΩ (nominal), < 100 pF, ac-coupled. Model 787 Calibration Manual
DC Millivolts
Range (mV dc)
Resolution
400.0
0. 1 mV
Input impedance: 10 MΩ (...
Calibration Guide - Page 16
Model 787 Calibration Manual
DC Current Output
Source mode
Simulate Mode
Span: 0 mA or 4 mA to 20 mA, with overrange to 24 mA Accuracy: 0.05 % of span Compliance voltage: ...
Calibration Guide - Page 18
... the input terminal-end of the case top to the ProcessMeter, use ONLY specified replacement fuses with the amperage, voltage, interrupt and speed ratings shown in the OFF position...-blow fuse. (Fluke PN 943121.) Both fuses are closed and secured before replacing a fuse. Replace the fuse only with a separate 440 mA fuse. Model 787 Calibration Manual
Checking and Replacing Fuses WWarning
To ...
Calibration Guide - Page 20
... Module serviced. • Make sure that the HP 34401A may only be computer-automated (using Fluke's MET...Fluke's MET/CAL Calibration Software version 6.0 or later, a 787 Calibration Module, a Fluke 5500A or 5520A Calibrator, and either looks damaged. • Before proceeding with the 5520A Calibrator. Preparing to the MET/CAL manual set for the 787 ProcessMeter are available. Replace...
Calibration Guide - Page 21
... use the 787 ProcessMeter and the required equipment. Remove all connection diagrams for your instrument. If in doubt have the required equipment available. (See Table 2.) 2. Make sure the UUT has a fresh battery. If you have the ProcessMeter or Calibration Module serviced.
• To avoid electrical shock, always place the calibrator in this manual. 3.
Calibration Guide - Page 28
... Standby (STBY) mode. 2.
Using the Fluke 5440A-7002 low thermal leads, connect the...•
SHIFT
ENTER
SETUP RESET
NEW REF
CE
MEAS TC
TRIG OUT
MULT
DIV
x
÷
EDIT FIELD
POWER
I O
Figure 8. Apply the calibrator resistance values in Table 7 in Figure 8. 6. Resistance Measurement Test Connections
LT004F.EPS
20 Model 787 Calibration Manual
Resistance Measurement Test ...
Calibration Guide - Page 30
...
4
5
6
n
W
¡F
k
A
¡C
p
1
2
3
M
F
+/
0
•
SHIFT
ENTER
SETUP RESET
NEW REF
CE
MEAS TC
TRIG OUT
MULT
DIV
x
÷
EDIT FIELD
POWER
I O
Figure 9. DC mV Measurement ...the UUT to the acceptable readings shown.
787 Range No Range Switching No Range Switching
Table 8. Model 787 Calibration Manual
DC Millivolts Measurement Test 1. Put the calibrator...
Calibration Guide - Page 34
...doubt have the ProcessMeter or Calibration Module serviced. • Make sure that the ...Fluke's MET/CAL Calibration Software and the 787 Calibration Module. contact Fluke to arrange to its specifications. Preparing for cracks, missing plastic, or damaged insulation. Replace... appears to operate abnormally.
Model 787 Calibration Manual
Calibration
The 787 Processmeter is detected, do not...
Calibration Guide - Page 36
...rotary switch on the UUT to the Calibration Module, and plug the battery eliminator into the connector on the Fluke 5500A and 5520A calibrators. 6. Connect Calibration Module to the UUT. 5. Attach the battery door on the ... cable. (See Figure 13.)
Note The calibration procedure does not support the UUT port on the battery door of the Calibration Module.
4. Model 787 Calibration Manual
3.
Calibration Guide - Page 37
... use the battery eliminator supplied with the calibration module (see Table 2).
787CAL 787 CALIBRATION MODULE
SEE THE "787 CALIBRATION MANUAL" FOR OPERATION INSTRUCTIONS.
DISCONNECT FROM MODEL 787
BATTERY CABLE BEFORE OPENING CALIBRATION MODULE CASE.
THIS MODULE SHOULD BE OPERATED BY QUALIFIED SERVICE AND CALIBRATION PERSONNEL ONLY. WARNING
TO AVOID ELECTRICAL SHOCK FASTEN BATTERY DOOR TO...
Calibration Guide - Page 38
... (STBY) before prompting you will be prompted to set Product Overview Manual Users Manual (CD-ROM) Calibration Manual (not shown)
Fluke No. 614487 CG81G 943121 619962 619939 832246 824466 831933...Model 787 Calibration Manual
Using the MET/CAL Calibration Software To calibrate the UUT using the MET/CAL Calibration Software, start MET/CAL and follow the prompts.
Replaceable Parts
When servicing...