Fluke 61 Infrared Thermometer Datasheet
Page 1
... dark • Automatic sleep mode after 7 seconds extends battery life • Alkaline batteries provide 4000 typical measurements The Fluke 61 Infrared Thermometer provides quick non-contact temperature measurement in U.S.A. 3/2002 1670797 D-ENG-N Rev B Even in less than one... (30 °F) to 525 °F) 0.2 °C (0.5 °F) +/- 2% of reading or 2 °C (3.5 °F) whichever is the Fluke 61. Measurement specifications Range Resolution Repeatability Accuracy Optical Resolution Emissivity Batteries -18 C to 275 °C (0 °F to 275 °C (525 °F) [with its backlit...
... dark • Automatic sleep mode after 7 seconds extends battery life • Alkaline batteries provide 4000 typical measurements The Fluke 61 Infrared Thermometer provides quick non-contact temperature measurement in U.S.A. 3/2002 1670797 D-ENG-N Rev B Even in less than one... (30 °F) to 525 °F) 0.2 °C (0.5 °F) +/- 2% of reading or 2 °C (3.5 °F) whichever is the Fluke 61. Measurement specifications Range Resolution Repeatability Accuracy Optical Resolution Emissivity Batteries -18 C to 275 °C (0 °F to 275 °C (525 °F) [with its backlit...
FE 61 Users Manual
Page 2
Specifications Temperature range -18 to 275°C (0 to 525°F) Display Resolution 0.2°C or 0.5°F Accuracy (assumes ambient operating temperature of 23°C [73°F]) Temperature ... holster 341 g (0.75lb); 190 x 51 x 41 mm (7.5 x 2.0 x 1.6 in) with holster Power 9V Alkaline or NiCd battery Battery life (Alkaline) 12 hrs Distance to Spot Size 8:1 Specifications subject to change without notice.
Specifications Temperature range -18 to 275°C (0 to 525°F) Display Resolution 0.2°C or 0.5°F Accuracy (assumes ambient operating temperature of 23°C [73°F]) Temperature ... holster 341 g (0.75lb); 190 x 51 x 41 mm (7.5 x 2.0 x 1.6 in) with holster Power 9V Alkaline or NiCd battery Battery life (Alkaline) 12 hrs Distance to Spot Size 8:1 Specifications subject to change without notice.
FE 61 Users Manual
Page 7
... Laser doesn't work Problem Target temperature is over or under range Possible low battery Possible dead battery Low or dead battery Action Select target within specifications Check and/or replace battery Check and/or replace battery Replace battery 5 To compensate, cover the surface to be moistened with a moist cotton swab. Allow...
... Laser doesn't work Problem Target temperature is over or under range Possible low battery Possible dead battery Low or dead battery Action Select target within specifications Check and/or replace battery Check and/or replace battery Replace battery 5 To compensate, cover the surface to be moistened with a moist cotton swab. Allow...