Fluke 1620A-S-156 Support and Manuals
Get Help and Manuals for this Fluke item
This item is in your list!
View All Support Options Below
Free Fluke 1620A-S-156 manuals!
Problems with Fluke 1620A-S-156?
Ask a Question
Free Fluke 1620A-S-156 manuals!
Problems with Fluke 1620A-S-156?
Ask a Question
Popular Fluke 1620A-S-156 Manual Pages
User Guide - Page 16
... CHINA
Phone: +86-10-6-512-3436 Telefax: +86-10-6-512-3437 E-mail: xingye.han@fluke.com.cn
Fluke South East Asia Pte Ltd. 1620A "DewK" Thermo-hygrometer User's Guide
Telefax: +1.801.763.1010 E-mail: support@hartscientific.com
Fluke Nederland B.V. Fluke ASEAN Regional Office Service Center 60 Alexandra Terrace #03-16 The Comtech (Lobby D) 118502 SINGAPORE
Phone: +65 6799...
User Guide - Page 17
• Model Number • Serial Number • Voltage • Complete description of the problem
1 Before You Start Authorized Service Centers
5
User Guide - Page 19
...thermo-hygrometer. 2 Introduction
2
Introduction
Fluke's Hart Scientific Division's 1620A is detachable, cable-extendable, and interchangeable, with self-contained calibration; Its unique combination of features makes it suitable for easy recalibrations
• Optional software logs in real-time or shows graphical/statistical data
• Password protection of the thermo-hygrometer...
User Guide - Page 22
...this manual.
• For full accuracy, operate the instrument within the calibrated temperature and relative humidity range of the sensors.
1620A DewK...Guide
Size (DewK)HxWxD Size (Probes) Weight
125 x 211 x 51 mm (4.9 x 8.3 x 2.0 in) 79 mm H x 19 mm dia. (3.1 x 0.75 in) 0.7 kg (1.5 lb.)
3.2
Environmental Conditions
Although the instrument has been designed for optimum durability and trouble...
User Guide - Page 23
... thermo-hygrometer.
Always handle these devices with it are sensitive instruments that the following items are present:
• 1620A Thermo-Hygrometer • AC adapter and power cord • Serial cable • Manual • Report of calibration • Wall mount bracket • Sensor • 9V battery
If all components are not present, call your...
User Guide - Page 71
... happen if the daily stats record time is set to 00:00, the daylight saving mode is with the COMM password parameter (see Section 7.5.4, Password).
In other words, the data prior to setup the communication parameters for the same date. To prevent confusion and time ambiguity problems, avoid running environment-sensitive operations during the fall...
User Guide - Page 77
... to access the password settings. In applications where extra security is enabled, it also shows its sensors and the ID (name) and calibration dates of the 1620A can be entered correctly to change them. When the parameter window is updated with an internet browser using Hart Scientific's LogWare III Software, COMMAND must be set each digit of...
User Guide - Page 84
...:LOW? ALARm:RHUMidity:RATE:ENABle? 1620A "DewK" Thermo-hygrometer User's Guide
Table 4 Alphabetical List Commands
Command ...model number, serial number, and firmware version
Section 8.2.7.1
Returns configuration options
Section 8.2.7.2
Sets the instrument operating parameters to defined conditions Section 8.2.7.3
Returns the Service Request Enable register
Section 8.2.11.5
Sets the Service...
User Guide - Page 120
... 0.002 The CALibrate suffix, , specifies the channel (1 or 2). This command is reported as "0". Response: "2626-S","0" The model number of sensor models currently connected to an input, the model number is password protected (see Section 8.2.10, Password Commands). The sensor model numbers are enclosed in quotes and separated by a comma.
*RST Sets the instrument settings to the defined...
User Guide - Page 121
... -350,"Queue overflow" and all but the first nine errors are reported in the order they occurred. SYSTem:BOOT:VERSion? Returns a message from the speaker. Response: C
109
Returns the firmware version. Example: UNIT:TEMP? Example: SYST:VERS? Refer to Troubleshooting section for the Status BYTE Register to ten messages. 8.2.7.4 8.2.7.5 8.2.7.6
8.2.7.7 8.2.7.8 8.2.7.9
8 Digital...
User Guide - Page 130
... if the alarm settings are any password-protected settings. Returns the state of the alarm settings password. Response: 0 The response is password protected. 1620A "DewK" Thermo-hygrometer User's Guide
8.2.10.1 8.2.10.2 8.2.10.3 8.2.10.4 8.2.10.5
SYSTem:PASSword:ALARm? otherwise a value of 1 indicates the password was successfully entered and password-protected settings can be changed...
User Guide - Page 148
1620A "DewK" Thermo-hygrometer User's Guide
ΔHSL = −25% × [RHerror(RH3) − RHerror(RH1)] (RH3 − RH1)
HSL′ = HSL + ΔHSL 5. Calculate the slope-adjusted humidity errors:
...ΔHOS
7. Also set the DATE to the current date and set ALERT to ON. Do not change the serial number. Calculate the median slope-adjusted humidity error, the adjustment Δ...
User Guide - Page 152
.... BATTERY: NOT INSTALLED
Check that the sensors are reported on the screen. Replace the battery. CLOCK: INVALID TIME
Set the time/date.
SENSOR : NOT ATTACHED
Check that a battery is a table of one or more component causes error messages to be corrected by completing the actions listed.
Contact an Authorized Service Center. SENSOR : CALIBRATION EXPIRED Contact an...
User Guide - Page 153
...data.
141
An error message and important troubleshooting information will help the Service Center in troubleshooting and solving the problem that has occurred. Record all error messages and information ...calibration parameters stored in its memory. Before contacting an Authorized Service Center for details on the computer using the RS-232 serial port. Configure the communication settings...
User Guide - Page 156
...328.
However, it does utilize a 9V backup battery that the 1620A is found in onboard memory? Q. The sensor's calibration information is stored in the field? What happens when memory is automatically... 89/336/EEC, ETSI EN 301 489-1 and EN 301 489-17;
1620A "DewK" Thermo-hygrometer User's Guide
11.3.3.2 11.3.3.3
11.4
144
WARNING: To satisfy FCC RF exposure requirements for...