Fluke 1620A-S-156 Support and Manuals

Get Help and Manuals for this Fluke item

View All Support Options Below
Free Fluke 1620A-S-156 manuals!
Problems with Fluke 1620A-S-156?

Ask a Question

Popular Fluke 1620A-S-156 Manual Pages

User Guide - Page 16

... CHINA Phone: +86-10-6-512-3436 Telefax: +86-10-6-512-3437 E-mail: xingye.han@fluke.com.cn Fluke South East Asia Pte Ltd. 1620A "DewK" Thermo-hygrometer User's Guide Telefax: +1.801.763.1010 E-mail: support@hartscientific.com Fluke Nederland B.V. Fluke ASEAN Regional Office Service Center 60 Alexandra Terrace #03-16 The Comtech (Lobby D) 118502 SINGAPORE Phone: +65 6799...
User Guide - Page 17

Model Number • Serial Number • Voltage • Complete description of the problem 1 Before You Start Authorized Service Centers 5
User Guide - Page 19

...thermo-hygrometer. 2 Introduction 2 Introduction Fluke's Hart Scientific Division's 1620A is detachable, cable-extendable, and interchangeable, with self-contained calibration; Its unique combination of features makes it suitable for easy recalibrations • Optional software logs in real-time or shows graphical/statistical data • Password protection of the thermo-hygrometer...
User Guide - Page 22

...this manual. • For full accuracy, operate the instrument within the calibrated temperature and relative humidity range of the sensors. 1620A DewK...Guide Size (DewK)HxWxD Size (Probes) Weight 125 x 211 x 51 mm (4.9 x 8.3 x 2.0 in) 79 mm H x 19 mm dia. (3.1 x 0.75 in) 0.7 kg (1.5 lb.) 3.2 Environmental Conditions Although the instrument has been designed for optimum durability and trouble...
User Guide - Page 23

... thermo-hygrometer. Always handle these devices with it are sensitive instruments that the following items are present: • 1620A Thermo-Hygrometer • AC adapter and power cord • Serial cable • Manual • Report of calibration • Wall mount bracket • Sensor • 9V battery If all components are not present, call your...
User Guide - Page 71

... happen if the daily stats record time is set to 00:00, the daylight saving mode is with the COMM password parameter (see Section 7.5.4, Password). In other words, the data prior to setup the communication parameters for the same date. To prevent confusion and time ambiguity problems, avoid running environment-sensitive operations during the fall...
User Guide - Page 77

... to access the password settings. In applications where extra security is enabled, it also shows its sensors and the ID (name) and calibration dates of the 1620A can be entered correctly to change them. When the parameter window is updated with an internet browser using Hart Scientific's LogWare III Software, COMMAND must be set each digit of...
User Guide - Page 84

...:LOW? ALARm:RHUMidity:RATE:ENABle? 1620A "DewK" Thermo-hygrometer User's Guide Table 4 Alphabetical List Commands Command ...model number, serial number, and firmware version Section 8.2.7.1 Returns configuration options Section 8.2.7.2 Sets the instrument operating parameters to defined conditions Section 8.2.7.3 Returns the Service Request Enable register Section 8.2.11.5 Sets the Service...
User Guide - Page 120

... 0.002 The CALibrate suffix, , specifies the channel (1 or 2). This command is reported as "0". Response: "2626-S","0" The model number of sensor models currently connected to an input, the model number is password protected (see Section 8.2.10, Password Commands). The sensor model numbers are enclosed in quotes and separated by a comma. *RST Sets the instrument settings to the defined...
User Guide - Page 121

... -350,"Queue overflow" and all but the first nine errors are reported in the order they occurred. SYSTem:BOOT:VERSion? Returns a message from the speaker. Response: C 109 Returns the firmware version. Example: UNIT:TEMP? Example: SYST:VERS? Refer to Troubleshooting section for the Status BYTE Register to ten messages. 8.2.7.4 8.2.7.5 8.2.7.6 8.2.7.7 8.2.7.8 8.2.7.9 8 Digital...
User Guide - Page 130

... if the alarm settings are any password-protected settings. Returns the state of the alarm settings password. Response: 0 The response is password protected. 1620A "DewK" Thermo-hygrometer User's Guide 8.2.10.1 8.2.10.2 8.2.10.3 8.2.10.4 8.2.10.5 SYSTem:PASSword:ALARm? otherwise a value of 1 indicates the password was successfully entered and password-protected settings can be changed...
User Guide - Page 148

1620A "DewK" Thermo-hygrometer User's Guide ΔHSL = −25% × [RHerror(RH3) − RHerror(RH1)] (RH3 − RH1) HSL′ = HSL + ΔHSL 5. Calculate the slope-adjusted humidity errors: ...ΔHOS 7. Also set the DATE to the current date and set ALERT to ON. Do not change the serial number. Calculate the median slope-adjusted humidity error, the adjustment Δ...
User Guide - Page 152

.... BATTERY: NOT INSTALLED Check that the sensors are reported on the screen. Replace the battery. CLOCK: INVALID TIME Set the time/date. SENSOR : NOT ATTACHED Check that a battery is a table of one or more component causes error messages to be corrected by completing the actions listed. Contact an Authorized Service Center. SENSOR : CALIBRATION EXPIRED Contact an...
User Guide - Page 153

...data. 141 An error message and important troubleshooting information will help the Service Center in troubleshooting and solving the problem that has occurred. Record all error messages and information ...calibration parameters stored in its memory. Before contacting an Authorized Service Center for details on the computer using the RS-232 serial port. Configure the communication settings...
User Guide - Page 156

...328. However, it does utilize a 9V backup battery that the 1620A is found in onboard memory? Q. The sensor's calibration information is stored in the field? What happens when memory is automatically... 89/336/EEC, ETSI EN 301 489-1 and EN 301 489-17; 1620A "DewK" Thermo-hygrometer User's Guide 11.3.3.2 11.3.3.3 11.4 144 WARNING: To satisfy FCC RF exposure requirements for...

Fluke 1620A-S-156 Reviews

Do you have an experience with the Fluke 1620A-S-156 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 1620A-S-156 Search Terms

The following terms are frequently used to search for Fluke 1620A-S-156 support:

Ask a New Question
Use the box below to post a new question about Fluke 1620A-S-156.
Manuals / Documents
Download any of our Fluke 1620A-S-156 manuals for free!

We have the following 1 documents available for the Fluke 1620A-S-156:
  • User Guide
Related Items

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 1620A-S-156 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 1620A-S-156 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.