Fluke 437-II Support and Manuals

Get Help and Manuals for this Fluke item

View All Support Options Below
Free Fluke 437-II manuals!
Problems with Fluke 437-II?

Ask a Question

Most Recent Fluke 437-II Questions

How Can I Use Fluke 700pd6
(Posted by elhassanali19 8 years ago)

Fluke 437-II Videos

Fluke 437 II - ?????????? ???????? ????????????? ???????
Duration: 3:50
Total Views: 2
Fluke 430 II Serisi(434-II,435-II,437-II) Ürün Tan?t?m Videosu
Duration: 2:31
Total Views: 15

Popular Fluke 437-II Manual Pages

Manual - Page 10

... are used on the World Wide Web at : www. .com 1.877.766.5412 Set of 5 5 Test Leads, 2.5 m + Color Coding Clips. Fluke 434-II/435-II/437-II Users Manual # Description 1 Power Quality Analyzer Fluke 43x Series II + Side Strap, Battery Pack BP290 (28 Wh) and 8 GB SD Memory Card Installed 2 Decal Set for PC Connection (USB-A to the user. A Warning identifies conditions and actions that...
Manual - Page 19

... the possibility to measure in Chapter 7 to 22. Each measuring mode is started. Fluke 435-II and 437-II have switched on how to check power distribution systems. Some give a general impression of power system performance. The clamps are described in detail in 400 Hz power systems, and has a heavy duty Hard Case with rollers. Refer to facilitate proper signal...
Manual - Page 43

Fluke 437-II is able to get a first impression of power system performance before examining the system in 400 Hz power systems (Marine, Aerospace, Rail, Military). Use the up/down arrow keys to -line. The rms voltages are shown neutral-to-line and line-to scroll the Meter screen. 8-1 MyFlukeStore Shop for Fluke products online at: www. .com 1.877...
Manual - Page 53

... of Interharmonics is measured. Harmonics can be viewed in Fluke 437-II. Measurement of harmonics is not displayed. For further information refer to the full signal is disabled. The phase angle is limited to the Harmonics Bar Graph screen: c MENU 10-1 MyFlukeStore Shop for measurements in 400 Hz power systems such as offered in a Bar Graph display...
Manual - Page 59

..., there is to use for power calculations; VA∑. 11-1 MyFlukeStore Shop for Fluke products online at the fundamental frequency (60, 50 Hz, or 400 Hz in Fluke 437-II) for rms based measurements. The related Trend screen shows the changes over time of use the Unified method to chapter 24 for the Fluke 430 series II instruments is also a 'classic...
Manual - Page 71

In a 3-phase power system, the phase shift between voltages and between voltages and currents. Unbalance mode offers a Meter screen, a related Trend display, Events tables, and a Phasor display. Measuring results are based upon the fundamental frequency component (60 Hz, 50 Hz, or 400 Hz in Fluke 437-II) using method of symmetrical components). Phasor screen To access the Unbalance Phasor...
Manual - Page 79

.... Monitor is used. When selecting timed start of the measurement. Note: Monitor is not available for Fluke products online at: www. .com 1.877.766.5412 Flicker 4. Timed start in Fluke 437-II. 16-1 MyFlukeStore Shop for measurements in 400 Hz power systems such as offered in combination with the 10 minute real time clock is started via...
Manual - Page 99

.... Note: Mains Signaling is not available for measurements in 400 Hz power systems such as ripple control). Measuring results are selectable after a measurement is attainable via key sequence SETUP, F4 - Amplitude is significantly lower than that is a function available in Fluke 437-II. 20-1 MyFlukeStore Shop for 50 Hz systems. Selection of the measurement and Immediate or Timed...
Manual - Page 107

Chapter 22 Shipboard V/A/Hz Introduction Shipboard V/A/Hz (Volts/Amps/Hertz) displays a Meter screen with the requirements of all values in a table...STD-1399-300B. Events such as dips and swells are useful for Fluke products online at: www. .com 1.877.766.5412 The function is available in the Fluke 437-II and provides measuring functions that are listed in the Meter screen. Meter...
Manual - Page 121

... key F5 - Use the up the Analyzer MANUAL SETUP 1 Press the SETUP key and next Function key F4 - Press ENTER to the power system. MANUAL SETUP to reach the MANUAL SETUP screen. 2 Use the up/down arrow keys to select the Nominal Frequency. Sensitivity x10 increases amps sensitivity by -step example on in Fluke 437-II also 400 Hz). Date, Time: use the arrow...
Manual - Page 136

...437-II Users Manual Installation of 1 year is recommended. To order replacement parts or additional accessories, contact your authorized Fluke Service Center if the calibration interval has been expired. Item Ordering Code Power Adapter Rechargeable Li-ion battery 28 Wh Test Lead Set 2.5 m incl. Flexible 6000 A AC Current Clamp Set (4 pieces). INSTALL OPTION. For this Analyzer...
Manual - Page 139

... without tolerances are based on the results of an average instrument excluding accessories. Chapter 27 Specifications Introduction Models Concerned Fluke 434-II: Energy Analyzer Fluke 435-II: Power Quality and Energy Analyzer Fluke 437-II: Power Quality and Energy Analyzer 400 Hz. This manual contains information and warnings that must be followed by the user to ensure safe operation and...
Manual - Page 142

...to 150 Power Quality parameters measured simultaneously on 4 phases Vrms, V tol%, V imb%, V mod, A rms, A imb%, Hz, Hz 10s, Hz tol, Hz tol%, Hz mod, Hz mod% (all acc. Note: not available in Fluke 437-II Pst (1min), Pst, Plt, Pinst, Vrms½, Arms½, Hz. To MIL-STD-1399-300B). Note: not supported for measurements at 400 Hz as offered in Fluke 434-II/435-II 27-4 MyFlukeStore...
Manual - Page 143

...5...2000 A 0.5...200 A (ac only) Hz2 Fluke 435-II /437-II @ 50 Hz nominal Fluke 435-II /437-II @ 60 Hz nominal Fluke 437-II @ 400 Hz nominal 42.5 ... 57.5 Hz 51 ... 69 Hz 340 ... 460 Hz 1 V 0.1 V 0.1 V 0.1 V 0.1 V 0.01 1 A 0,1 A 1 A 0.1 A 1 Arms 1 Arms 0.01 1 A 0,1 A 1 A 0.1 A 1 A 0,1 A 1 A 0.1 A 0.001 Hz 0.001 Hz 0.1 Hz 27 Specifications Electrical Measurements Accuracy ± 0.1% of nominal...
Manual - Page 169

..., contains: the instrument's embedded software and calibration data. SN74V235-7PAG, contains: data to be exchanged between DSP and Microcontroller. 5. SD Memory Card. Appendix C Instrument Security Procedures Introduction Model Numbers: Fluke 434-II, Fluke 435-II, Fluke 437-II Short Description: 3-Phase Energy & Power Quality Analyzer Memory. Fluke 43x-II has the following memory devices...

Fluke 437-II Reviews

Do you have an experience with the Fluke 437-II that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 437-II Search Terms

The following terms are frequently used to search for Fluke 437-II support:

Ask a New Question
Use the box below to post a new question about Fluke 437-II.
Manuals / Documents
Download any of our Fluke 437-II manuals for free!

We have the following 2 documents available for the Fluke 437-II:
  • Manual
  • Datasheet

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 437-II manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 437-II user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.