Fluke 192, 196, and 199 Scopemeter Datasheet
Page 1
...190C) of waveforms • 1000 V CAT II and 600 V CAT III safety certified • Five hours rechargeable Ni-MH battery pack In Trendplot or "paperless recorder" mode, you can Waveform Pass/Fail testing simultaneously acquire two waveforms and analyze them with a ... for instance, when making combination of traces, 190 Series! FLUKE-196C/003S ScopeMeter 100 MHz color with SCC kit FLUKE-199C/003 ScopeMeter 200 MHz color FLUKE-199C/003S ScopeMeter 200 MHz color with SCC kit FLUKE-196C/003 ScopeMeter 100 MHz color Digital Persistence uses multiple intensity levels and user...
...190C) of waveforms • 1000 V CAT II and 600 V CAT III safety certified • Five hours rechargeable Ni-MH battery pack In Trendplot or "paperless recorder" mode, you can Waveform Pass/Fail testing simultaneously acquire two waveforms and analyze them with a ... for instance, when making combination of traces, 190 Series! FLUKE-196C/003S ScopeMeter 100 MHz color with SCC kit FLUKE-199C/003 ScopeMeter 200 MHz color FLUKE-199C/003S ScopeMeter 200 MHz color with SCC kit FLUKE-196C/003 ScopeMeter 100 MHz color Digital Persistence uses multiple intensity levels and user...
FE 192,196,199 C Users Manual
Page 10
Fluke 192B - 196B/C - 199B/C Users Manual Unpacking the Test Tool Kit The following items are included in your test tool kit: 1 2 e (2x) (1x) f (2x) b a (2x) c (2x) (2x) d Note When new, the rechargeable NiMH battery is not fully charged. ScopeMeter Test Tool Kit 2 See Chapter 8. 6 7 3 4 9 10 11 b (2x) a 5 8 Figure 1.
Fluke 192B - 196B/C - 199B/C Users Manual Unpacking the Test Tool Kit The following items are included in your test tool kit: 1 2 e (2x) (1x) f (2x) b a (2x) c (2x) (2x) d Note When new, the rechargeable NiMH battery is not fully charged. ScopeMeter Test Tool Kit 2 See Chapter 8. 6 7 3 4 9 10 11 b (2x) a 5 8 Figure 1.
FE 192,196,199 C Users Manual
Page 11
# Description 1 ScopeMeter Test Tool 2 Battery Charger (country dependent) 3 10:1 Voltage Probe Set (red) a) 10:1 Voltage Probe (red) b) Hook Clip for Probe Tip (red) c) Ground Lead with Hook Clip (red) d) Ground ... 4 mm banana jack 6 Getting Started Manual 7 CD ROM with Users Manual (multi-language) 8 Shipment box (basic version only) Unpacking the Test Tool Kit Fluke 192B, 196B/C and 199B/C S versions include also the following items: # Description 9 Optically Isolated USB Adapter/Cable 10 FlukeView® ScopeMeter® Software for Windows® 11 Hard Case 3
# Description 1 ScopeMeter Test Tool 2 Battery Charger (country dependent) 3 10:1 Voltage Probe Set (red) a) 10:1 Voltage Probe (red) b) Hook Clip for Probe Tip (red) c) Ground Lead with Hook Clip (red) d) Ground ... 4 mm banana jack 6 Getting Started Manual 7 CD ROM with Users Manual (multi-language) 8 Shipment box (basic version only) Unpacking the Test Tool Kit Fluke 192B, 196B/C and 199B/C S versions include also the following items: # Description 9 Optically Isolated USB Adapter/Cable 10 FlukeView® ScopeMeter® Software for Windows® 11 Hard Case 3
FE 192,196,199 C Users Manual
Page 13
...insulated voltage probes, test leads and adapters supplied with the test tool, or indicated by Fluke as limits for "working voltage". Measurement Category III refers to the isolated inputs when ... not apply voltages that are mentioned in the warnings, are given as suitable for the Fluke190 ScopeMeter series. • Before use, inspect voltage probes, test leads and accessories for mechanical damage and... Do not insert metal objects into connectors. • Always use . • Always connect the battery charger first to the ac outlet before connecting it to the test tool. • Do not ...
...insulated voltage probes, test leads and adapters supplied with the test tool, or indicated by Fluke as limits for "working voltage". Measurement Category III refers to the isolated inputs when ... not apply voltages that are mentioned in the warnings, are given as suitable for the Fluke190 ScopeMeter series. • Before use, inspect voltage probes, test leads and accessories for mechanical damage and... Do not insert metal objects into connectors. • Always use . • Always connect the battery charger first to the ac outlet before connecting it to the test tool. • Do not ...
FE 192,196,199 C Users Manual
Page 96
...you information about the model number with software version, the calibration number with latest calibration date, and the latest battery refresh date. 3 Return. Fluke 192B - 196B/C - 199B/C Users Manual Displaying Calibration Information You can display version number and calibration date: ...For additional optional accessories, see the ScopeMeter Accessories booklet. Parts and Accessories The following tables list the user-replaceable parts for recalibration. 88 To order replacement parts or additional accessories, contact your local Fluke representative for the various test tool ...
...you information about the model number with software version, the calibration number with latest calibration date, and the latest battery refresh date. 3 Return. Fluke 192B - 196B/C - 199B/C Users Manual Displaying Calibration Information You can display version number and calibration date: ...For additional optional accessories, see the ScopeMeter Accessories booklet. Parts and Accessories The following tables list the user-replaceable parts for recalibration. 88 To order replacement parts or additional accessories, contact your local Fluke representative for the various test tool ...
FE 192,196,199 C Users Manual
Page 97
For other countries, a line plug adapter complying with the Fluke ScopeMeter 190 series test tool. Voltage Probe Set (Red), designed for Probe Tip (black) 8 Maintaining the Test Tool Parts and Accessories Ordering Code BC190/801 BC190/...; Ground Lead with Hook Clip (red) • Ground Lead with Mini Alligator Clip (black) • Ground Spring for use in North America. Replacement Parts Item Battery Charger, available models: Universal Europe 230 V, 50 and 60 Hz North America 120 V, 50 and 60 Hz United Kingdom 240 V, 50 and 60 Hz Japan...
For other countries, a line plug adapter complying with the Fluke ScopeMeter 190 series test tool. Voltage Probe Set (Red), designed for Probe Tip (black) 8 Maintaining the Test Tool Parts and Accessories Ordering Code BC190/801 BC190/...; Ground Lead with Hook Clip (red) • Ground Lead with Mini Alligator Clip (black) • Ground Spring for use in North America. Replacement Parts Item Battery Charger, available models: Universal Europe 230 V, 50 and 60 Hz North America 120 V, 50 and 60 Hz United Kingdom 240 V, 50 and 60 Hz Japan...
Fluke ScopeMeter Product Datasheet
Page 2
... The waveform memory of all models reveals signal changes instantaneously, useful for revealing the effects of a high-performance oscilloscope in a handheld, battery powered instrument. • Dual-input - 200, 100 or 60 MHz bandwidth • Up to 2.5 GS/s real-time sampling per...190B Series: Speed, performance and analysis power For the more demanding applications, the ScopeMeter 190 Series highperformance oscilloscopes offer specifications usually found on -line demonstration, go to www.fluke.com/scopemeter High sampling rates give you will act as 3000 samples per input •...
... The waveform memory of all models reveals signal changes instantaneously, useful for revealing the effects of a high-performance oscilloscope in a handheld, battery powered instrument. • Dual-input - 200, 100 or 60 MHz bandwidth • Up to 2.5 GS/s real-time sampling per...190B Series: Speed, performance and analysis power For the more demanding applications, the ScopeMeter 190 Series highperformance oscilloscopes offer specifications usually found on -line demonstration, go to www.fluke.com/scopemeter High sampling rates give you will act as 3000 samples per input •...
Fluke ScopeMeter Product Datasheet
Page 4
...or difficult-to-reach locations means you have all the functionality of an accidental ground short circuit when making a connection. The Fluke ScopeMeter 120 Series test tools and the included shielded test leads are safety certified for additional details about triggering and instrument settings and you... or common time related measurements like variable frequency motor drives. Battery powered mobility Up to seven hours of battery operation frees you find the source of 20 MHz (Fluke 123) or 40 MHz (Fluke 124, 125) the Fluke 120 Series will capture and display almost any signal. In ...
...or difficult-to-reach locations means you have all the functionality of an accidental ground short circuit when making a connection. The Fluke ScopeMeter 120 Series test tools and the included shielded test leads are safety certified for additional details about triggering and instrument settings and you... or common time related measurements like variable frequency motor drives. Battery powered mobility Up to seven hours of battery operation frees you find the source of 20 MHz (Fluke 123) or 40 MHz (Fluke 124, 125) the Fluke 120 Series will capture and display almost any signal. In ...
Fluke ScopeMeter Product Datasheet
Page 5
... mathematics Save set-ups and screens True-rms multimeter Safety, Power and Warranty Safety (EN61010-1) Battery Line power PC and printer interface Warranty 190C ScopeMeter Series 190B ScopeMeter Series 120 Series Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Fluke 125 Fluke 124 Fluke 123 200 MHz 100 MHz 200 MHz 100 MHz 60 MHz 40 MHz 40 MHz 20...
... mathematics Save set-ups and screens True-rms multimeter Safety, Power and Warranty Safety (EN61010-1) Battery Line power PC and printer interface Warranty 190C ScopeMeter Series 190B ScopeMeter Series 120 Series Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Fluke 125 Fluke 124 Fluke 123 200 MHz 100 MHz 200 MHz 100 MHz 60 MHz 40 MHz 40 MHz 20...