... Technical Data Never miss capturing a disturbance-with the Fluke 1750 Power Recorder. less "front panel interface" provides the ability to verify setup without a laptop along with a window into your installation or distribution system. • Power quality that meets the standard: All measurements comply with self- ... is recording, even in awkward test locations. • Threshold-free setup: Apply thresholds after data is collected with Fluke Power Analyze Software so there is no need to incorrect set-up in minutes with IEC61000-4-30 standards for correct evaluation of even...
... Technical Data Never miss capturing a disturbance-with the Fluke 1750 Power Recorder. less "front panel interface" provides the ability to verify setup without a laptop along with a window into your installation or distribution system. • Power quality that meets the standard: All measurements comply with self- ... is recording, even in awkward test locations. • Threshold-free setup: Apply thresholds after data is collected with Fluke Power Analyze Software so there is no need to incorrect set-up in minutes with IEC61000-4-30 standards for correct evaluation of even...
Fluke 1750 Three Phase Power Recorder Datasheet
Page 4
... of standard or customized templates. All the latest power quality standards are built-in IEC 61000-4-30 compliant measurement systems provide the confidence that all outlets in Fluke Power Analyze. Apply thresholds to analyze data. Simplified report writer feature included in a low-voltage power distribution system. 4 Fluke Corporation Fluke 1750 Three-Phase Power Recorder View data the way you and your...
... of standard or customized templates. All the latest power quality standards are built-in IEC 61000-4-30 compliant measurement systems provide the confidence that all outlets in Fluke Power Analyze. Apply thresholds to analyze data. Simplified report writer feature included in a low-voltage power distribution system. 4 Fluke Corporation Fluke 1750 Three-Phase Power Recorder View data the way you and your...
Fluke 1750 Three Phase Power Recorder Datasheet
Page 5
...A to 1000 A 100 A to 5000 A 100 A to set scale factors for accurate readings. All clamp-on one additional PC 1750/SITE-L • Fluke Power Analyze - Optional Accessories Fluke power quality current transformers and flexible current probes are matched to take full advantage of your instrument's ability to 5000 A Accuracy 1 % rdg ...60 cm (24 in) 60 cm (24 in) 120 cm (48 in ) dia. Cases 1750/CASE Transit Case • Rugged water tight transit case with Fluke power monitors (1750 and 1650). Additional SITE LICENSE • Site license for installation on unlimited PCs 4006 Security Cable...
...A to 1000 A 100 A to 5000 A 100 A to set scale factors for accurate readings. All clamp-on one additional PC 1750/SITE-L • Fluke Power Analyze - Optional Accessories Fluke power quality current transformers and flexible current probes are matched to take full advantage of your instrument's ability to 5000 A Accuracy 1 % rdg ...60 cm (24 in) 60 cm (24 in) 120 cm (48 in ) dia. Cases 1750/CASE Transit Case • Rugged water tight transit case with Fluke power monitors (1750 and 1650). Additional SITE LICENSE • Site license for installation on unlimited PCs 4006 Security Cable...
Fluke 1750 Three Phase Power Recorder Datasheet
Page 6
... resolution The PLL synchronizes to the A-N voltage for wye power types, and to the A-B voltage for 5 % to 100 % of current sensor range 6 Fluke Corporation Fluke 1750 Three-Phase Power Recorder All listed power types can be characterized as either wye or delta. 42... CTs, low impedance for Flexi-CTs Simultaneous digital sampling of voltage and current. Specifications for the System: Recorder and Power Analyze Software General Power quality measurement standards Conformance IEC 61999-1-4 Class 1, IEC 61000-4-30, IEEE519, IEEE1159, IEEE1459 and EN50160 Clock/calendar Leap years...
... resolution The PLL synchronizes to the A-N voltage for wye power types, and to the A-B voltage for 5 % to 100 % of current sensor range 6 Fluke Corporation Fluke 1750 Three-Phase Power Recorder All listed power types can be characterized as either wye or delta. 42... CTs, low impedance for Flexi-CTs Simultaneous digital sampling of voltage and current. Specifications for the System: Recorder and Power Analyze Software General Power quality measurement standards Conformance IEC 61999-1-4 Class 1, IEC 61000-4-30, IEEE519, IEEE1159, IEEE1459 and EN50160 Clock/calendar Leap years...
Fluke 1750 Three Phase Power Recorder Datasheet
Page 8
... V CAT IV (anticipated overvoltage: 8000 V) Ordering information Fluke-1750 Three-Phase Power Recorder Includes: • 1750 acquisition unit • PDA wireless "front panel interface" and charger power plug adapters • 4 - 400 A current probes (3140R) • 5 test leads and clips • SD memory card • Fluke Power View and Fluke Power Analyze software • Power cord with international plug set • Ethernet...
... V CAT IV (anticipated overvoltage: 8000 V) Ordering information Fluke-1750 Three-Phase Power Recorder Includes: • 1750 acquisition unit • PDA wireless "front panel interface" and charger power plug adapters • 4 - 400 A current probes (3140R) • 5 test leads and clips • SD memory card • Fluke Power View and Fluke Power Analyze software • Power cord with international plug set • Ethernet...
Fluke 1750 Calibration Manual
Page 11
... this product as an electricity meter or an overhead or underground utility service. Risk of danger. Symbols X Hazardous voltage. Power Requirements 100 to Fluke's web site for the System: Recorder and Power Analyze Software General Specifications Power Quality Measurement Standards Conformance IEC 61999-1-4 Class 1, IEC 61000-4-30 Class A or B depending on the Recorder are listed in...
... this product as an electricity meter or an overhead or underground utility service. Risk of danger. Symbols X Hazardous voltage. Power Requirements 100 to Fluke's web site for the System: Recorder and Power Analyze Software General Specifications Power Quality Measurement Standards Conformance IEC 61999-1-4 Class 1, IEC 61000-4-30 Class A or B depending on the Recorder are listed in...
Fluke 1750 Operators Manual
Page 9
1750 Power Recorder Introduction The Fluke 1750 Power Recorder is a comprehensive yet easy to use PC application, Power Analyze. The 1750 Power Recorder, referred to hereafter as standard equipment (not included in the location. • Simplified test lead connections to the power network Simply connect a ... • Connection diagrams for power quality investigations. On the current inputs, the Recorder automatically identifies what type of the 1750 Power Recorder are using the PDA, and then reconfirm correct readings. • Internal Uninterruptible Power Supply (UPS) An internal ...
1750 Power Recorder Introduction The Fluke 1750 Power Recorder is a comprehensive yet easy to use PC application, Power Analyze. The 1750 Power Recorder, referred to hereafter as standard equipment (not included in the location. • Simplified test lead connections to the power network Simply connect a ... • Connection diagrams for power quality investigations. On the current inputs, the Recorder automatically identifies what type of the 1750 Power Recorder are using the PDA, and then reconfirm correct readings. • Internal Uninterruptible Power Supply (UPS) An internal ...
Fluke 1750 Operators Manual
Page 10
...power quality events (disturbances) using Power Analyze on a PC after the event has been captured. This is called the "event detector" in the world: +1-425-446-5500 Or, visit Fluke's website at www.fluke.com. Data may then be analyzed using the Power Analyze software on a PC. To contact Technical Support: fpqsupport@fluke...with the Recorder. 1750 Operators Manual • Automatic disturbance capture The Recorder uses an automatic, self-learning threshold routine, which means you do not have to set up and start recording. Contacting Fluke To contact Fluke, call one of ...
...power quality events (disturbances) using Power Analyze on a PC after the event has been captured. This is called the "event detector" in the world: +1-425-446-5500 Or, visit Fluke's website at www.fluke.com. Data may then be analyzed using the Power Analyze software on a PC. To contact Technical Support: fpqsupport@fluke...with the Recorder. 1750 Operators Manual • Automatic disturbance capture The Recorder uses an automatic, self-learning threshold routine, which means you do not have to set up and start recording. Contacting Fluke To contact Fluke, call one of ...
Fluke 1750 Operators Manual
Page 58
Power Requirements 100 to 240 V rms ± 10 %, 47-63 Hz, 40 W Operating Time During Interruptions (internal UPS operation 5 minutes per interruption, 60 minutes total ...Delta, 2 ½ Element Wye Input Channels Voltage: 5 channels, AC/DC Current: 5 channels Voltage Channels Input resistance: 2 MΩ Input capacitance: 1750 Operators Manual Specifications for the System: Recorder and Power Analyze Software General Specifications Power Quality Measurement Standards Conformance IEC 61000-2-4:2002 Class 1, IEC 61000-4-30, IEEE519, IEEE1159, IEEE1459, IEC 61557-12:2008, and EN50160 Clock...
Power Requirements 100 to 240 V rms ± 10 %, 47-63 Hz, 40 W Operating Time During Interruptions (internal UPS operation 5 minutes per interruption, 60 minutes total ...Delta, 2 ½ Element Wye Input Channels Voltage: 5 channels, AC/DC Current: 5 channels Voltage Channels Input resistance: 2 MΩ Input capacitance: 1750 Operators Manual Specifications for the System: Recorder and Power Analyze Software General Specifications Power Quality Measurement Standards Conformance IEC 61000-2-4:2002 Class 1, IEC 61000-4-30, IEEE519, IEEE1159, IEEE1459, IEC 61557-12:2008, and EN50160 Clock...