User Manual
Page 3
Table of Contents Title Page Introduction ...1 How to Contact Fluke ...2 Safety Information...2 Before You Start ...5 WiFi and WiFi/BLE-to-USB Adapter 6 Magnet Hanger Kit ...7 Voltage Test Leads 7 Thin-Flexi Current Probe 8 Kensington Lock ...9 Accessories ...10 Storage ...11 Tilt Stand ...11 Power Supply ...11 How to Charge Battery 12 Navigation and User Interface 13 Applying the Connector Panel Decal 15 Power ON/OFF ...16 Mains Power Source 16 Measurement Line Power Source 16 Power from Battery 17 Touch Screen...18 Brightness Button 18 Calibration ...18 Basic Navigation ...18 i
Table of Contents Title Page Introduction ...1 How to Contact Fluke ...2 Safety Information...2 Before You Start ...5 WiFi and WiFi/BLE-to-USB Adapter 6 Magnet Hanger Kit ...7 Voltage Test Leads 7 Thin-Flexi Current Probe 8 Kensington Lock ...9 Accessories ...10 Storage ...11 Tilt Stand ...11 Power Supply ...11 How to Charge Battery 12 Navigation and User Interface 13 Applying the Connector Panel Decal 15 Power ON/OFF ...16 Mains Power Source 16 Measurement Line Power Source 16 Power from Battery 17 Touch Screen...18 Brightness Button 18 Calibration ...18 Basic Navigation ...18 i
User Manual
Page 13
...circuit is safe to touch. A voltage measurement is necessary to hazardous voltage. 3 Examine the test leads for all probes, test leads, and accessories before you apply or remove the flexible current probe. • Remove all measurements. • Do not use the Product if the protection ...when the other is still connected to know if a circuit is hazardous. • Use Product-approved measurement category (CAT), voltage, and amperage rated accessories (probes, test leads, and adapters) for damaged insulation and measure a known voltage. • Do not use the Product if it is damaged....
...circuit is safe to touch. A voltage measurement is necessary to hazardous voltage. 3 Examine the test leads for all probes, test leads, and accessories before you apply or remove the flexible current probe. • Remove all measurements. • Do not use the Product if the protection ...when the other is still connected to know if a circuit is hazardous. • Use Product-approved measurement category (CAT), voltage, and amperage rated accessories (probes, test leads, and adapters) for damaged insulation and measure a known voltage. • Do not use the Product if it is damaged....
User Manual
Page 15
...leads with stackable plugs, 10 cm (3.9 in) • Set of 2 test leads with your purchase. Check www.fluke.com for availability in the standard purchase list: • WiFi/BLE to USB Adapter • Magnet Hanger Kit ...8226; 4 GB USB Flash Drive (includes Users Manual and PC application software, Fluke Energy Analyze Plus) Power Logger Before You Start The 1738 Power Logger also includes these items in your country. Country-Specific Mains Power Cable...Plugs These items are available for the 1736 Power Logger as optional accessories. Before You Start Below is available for your country.
...leads with stackable plugs, 10 cm (3.9 in) • Set of 2 test leads with your purchase. Check www.fluke.com for availability in the standard purchase list: • WiFi/BLE to USB Adapter • Magnet Hanger Kit ...8226; 4 GB USB Flash Drive (includes Users Manual and PC application software, Fluke Energy Analyze Plus) Power Logger Before You Start The 1738 Power Logger also includes these items in your country. Country-Specific Mains Power Cable...Plugs These items are available for the 1736 Power Logger as optional accessories. Before You Start Below is available for your country.
User Manual
Page 17
... the black test lead to : • Hang the Logger with the threephase test lead, use the red and black test leads. Magnet Hanger Kit The accessory shown in Figure 3 is out of reach with power supply attached (use two magnets) • Hang the Logger separately (use two magnets) • Hang the...
... the black test lead to : • Hang the Logger with the threephase test lead, use the red and black test leads. Magnet Hanger Kit The accessory shown in Figure 3 is out of reach with power supply attached (use two magnets) • Hang the Logger separately (use two magnets) • Hang the...
User Manual
Page 20
...-ion Battery Soft Case Upgrade Kit for 1736 to 1738 (includes: Hanger, Magnet Probes, 1736 to 1738 Upgrade Kit, and Software License) Software License for IEEE 519 Reporting WiFi/BLE to www.fluke.com. The warranty on accessories, go to USB Adapter Set of the accessories that are available and sold separately for the Logger...
...-ion Battery Soft Case Upgrade Kit for 1736 to 1738 (includes: Hanger, Magnet Probes, 1736 to 1738 Upgrade Kit, and Software License) Software License for IEEE 519 Reporting WiFi/BLE to www.fluke.com. The warranty on accessories, go to USB Adapter Set of the accessories that are available and sold separately for the Logger...
User Manual
Page 21
... in use , attach the power supply to the Logger and open the tilt stand. If the Logger is stored for the Logger and all the accessories. To use , keep the Logger in the protective storage bag/case. Figure 6. The bag/case has sufficient space for an extended period of time or...
... in use , attach the power supply to the Logger and open the tilt stand. If the Logger is stored for the Logger and all the accessories. To use , keep the Logger in the protective storage bag/case. Figure 6. The bag/case has sufficient space for an extended period of time or...
User Manual
Page 61
... PQ 51 See page 58 for the software. Features are available as optional accessories to a WiFi infrastructure. Attach the USB flash drive to EN 50160: "voltage characteristics of the 1738 on a 1736 Logger. For more information about how to add the screenshot....License Features Feature WiFi Infrastructure [1] 1736/Upgrade IEEE 519/Report 1736 1738 • • • • • [1] The WiFi Infrastructure license is complimentary and enabled when you register the Logger at www.fluke.com. This includes the PQ Health logging overview screen with licensed ...
... PQ 51 See page 58 for the software. Features are available as optional accessories to a WiFi infrastructure. Attach the USB flash drive to EN 50160: "voltage characteristics of the 1738 on a 1736 Logger. For more information about how to add the screenshot....License Features Feature WiFi Infrastructure [1] 1736/Upgrade IEEE 519/Report 1736 1738 • • • • • [1] The WiFi Infrastructure license is complimentary and enabled when you register the Logger at www.fluke.com. This includes the PQ Health logging overview screen with licensed ...
User Manual
Page 64
... Number 4583625 4717789 4388072 4146702 4704200 see Figure 7 on page 15 see How to contact Fluke is 2 years. Service and Parts Replacement parts and accessories are listed in Table 7 and shown in Figure 12. Table 7. 1736/1738 Users Manual Calibration As an additional service we offer the regular examination and calibration of your...
... Number 4583625 4717789 4388072 4146702 4704200 see Figure 7 on page 15 see How to contact Fluke is 2 years. Service and Parts Replacement parts and accessories are listed in Table 7 and shown in Figure 12. Table 7. 1736/1738 Users Manual Calibration As an additional service we offer the regular examination and calibration of your...
User Manual
Page 75
... Display 4.3-inch active matrix color TFT, 480 pixels x 272 pixels, resistive touch panel Power/Charging/LED Indicator Warranty 1736/1738 and Power Supply 2 years (battery not included) Accessories 1 year Calibration Cycle 2 years Dimensions 1736/1738 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in) Power Supply 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in...
... Display 4.3-inch active matrix color TFT, 480 pixels x 272 pixels, resistive touch panel Power/Charging/LED Indicator Warranty 1736/1738 and Power Supply 2 years (battery not included) Accessories 1 year Calibration Cycle 2 years Dimensions 1736/1738 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in) Power Supply 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in...
User Manual
Page 79
... 2nd ... 50th Total Harmonic Distortion Calculated on 50 harmonics Events Voltage: Dips, Swells, Interruptions Current: Inrush Current Triggered Recordings 1738 or 1736 with 1736/Upgrade license Half cycle RMS of Voltage and Current Waveform of Voltage and Current Standards Compliance Harmonics IEC ... Power IEEE 1459 Power Quality Compliance 1738 or 1736 with pre-shared key Bluetooth read auxiliary measurement data from Fluke Connect 3000 series modules (requires WiFi/BLE adapter USB1 FC) USB-mini Data download device to PC Extension port Accessories 69 supply current: 120 mA WiFi...
... 2nd ... 50th Total Harmonic Distortion Calculated on 50 harmonics Events Voltage: Dips, Swells, Interruptions Current: Inrush Current Triggered Recordings 1738 or 1736 with 1736/Upgrade license Half cycle RMS of Voltage and Current Waveform of Voltage and Current Standards Compliance Harmonics IEC ... Power IEEE 1459 Power Quality Compliance 1738 or 1736 with pre-shared key Bluetooth read auxiliary measurement data from Fluke Connect 3000 series modules (requires WiFi/BLE adapter USB1 FC) USB-mini Data download device to PC Extension port Accessories 69 supply current: 120 mA WiFi...
User Manual
Page 80
1736/1738 Users Manual Accuracy at Reference Conditions (% of Reading + % of Range) ±(0.2 % + 0.01 %) ±(0.3 % + 0.02 %) ±(0.3 % + 0.02 %) ±(0.2 % + 0.02 %) ±(0.2 % + 0.02 %) ±(1 % + 0.02 %) ±(1... % + 0.05 %) ±0.15 % 70 Resolution 0.1 V 0.01 mV 0.1 mV 0.01 mV 0.1 mV 0.01 A 0.1 A 1 A 10 A 1 A 10 A 1 mA 10 mA 0.01 Hz 0.1 mV 0.1 V defined by accessory 0.1 % 0.1 % 0.1 % 0.1 % Intrinsic Accuracy at Reference Conditions Parameter Range Current Voltage Direct Input 1500 A Flex 3000 A Flexi 6000 A Flexi Rogowski Mode Clamp Mode 40 A Frequency Aux Input...
1736/1738 Users Manual Accuracy at Reference Conditions (% of Reading + % of Range) ±(0.2 % + 0.01 %) ±(0.3 % + 0.02 %) ±(0.3 % + 0.02 %) ±(0.2 % + 0.02 %) ±(0.2 % + 0.02 %) ±(1 % + 0.02 %) ±(1... % + 0.05 %) ±0.15 % 70 Resolution 0.1 V 0.01 mV 0.1 mV 0.01 mV 0.1 mV 0.01 A 0.1 A 1 A 10 A 1 A 10 A 1 mA 10 mA 0.01 Hz 0.1 mV 0.1 V defined by accessory 0.1 % 0.1 % 0.1 % 0.1 % Intrinsic Accuracy at Reference Conditions Parameter Range Current Voltage Direct Input 1500 A Flex 3000 A Flexi 6000 A Flexi Rogowski Mode Clamp Mode 40 A Frequency Aux Input...
Calibration Manual
Page 8
1736/1738 Calibration Manual Safety Information A Warning identifies hazardous conditions and procedures that can be closed and locked before you use the Product. WX Warning To prevent ... the Product if it is damaged or if the insulation shows signs of wear. • Use Product-approved measurement category (CAT), voltage, and amperage rated accessories (probes, test leads, and adapters) for all safety information before you use the Product. • Use the Product only as specified, or the protection supplied...
1736/1738 Calibration Manual Safety Information A Warning identifies hazardous conditions and procedures that can be closed and locked before you use the Product. WX Warning To prevent ... the Product if it is damaged or if the insulation shows signs of wear. • Use Product-approved measurement category (CAT), voltage, and amperage rated accessories (probes, test leads, and adapters) for all safety information before you use the Product. • Use the Product only as specified, or the protection supplied...
Calibration Manual
Page 9
... requirements before you apply or remove the flexible current probe. • Remove all probes, test leads, and accessories before the battery door is opened. • Do not use USB accessories when the Product is installed in damp or wet environments. • Use only the external mains power supply ...included with the Product. • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory. • Keep fingers behind the finger guards on the touch panel is damaged. • Do not touch the metal parts of one test lead ...
... requirements before you apply or remove the flexible current probe. • Remove all probes, test leads, and accessories before the battery door is opened. • Do not use USB accessories when the Product is installed in damp or wet environments. • Use only the external mains power supply ...included with the Product. • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory. • Keep fingers behind the finger guards on the touch panel is damaged. • Do not touch the metal parts of one test lead ...
Calibration Manual
Page 11
... Display 4.3-inch active matrix color TFT, 480 pixels x 272 pixels, resistive touch panel Power/Charging/LED Indicator Warranty 1736/1738 and Power Supply 2 years (battery not included) Accessories 1 year Calibration Cycle 2 years Dimensions 1736/1738 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in) Power Supply 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in...
... Display 4.3-inch active matrix color TFT, 480 pixels x 272 pixels, resistive touch panel Power/Charging/LED Indicator Warranty 1736/1738 and Power Supply 2 years (battery not included) Accessories 1 year Calibration Cycle 2 years Dimensions 1736/1738 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in) Power Supply 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in...
Calibration Manual
Page 13
... Total Harmonic Distortion Calculated on 50 harmonics Events Voltage: Dips, Swells, Interruptions Current: Inrush Current Triggered Recordings 1738 or 1736 with 1736/Upgrade license Half cycle RMS of Voltage and Current Waveform of Voltage and Current Standards... Class S, IEC62586-1 (PQI-S device) Power IEEE 1459 Power Quality Compliance 1738 or 1736 with pre-shared key Bluetooth read auxiliary measurement data from Fluke Connect 3000 series modules (requires WiFi/BLE adapter USB1 FC) USB-mini ... WiFi Supported modes Direct connection and connection to PC Extension port Accessories 7
... Total Harmonic Distortion Calculated on 50 harmonics Events Voltage: Dips, Swells, Interruptions Current: Inrush Current Triggered Recordings 1738 or 1736 with 1736/Upgrade license Half cycle RMS of Voltage and Current Waveform of Voltage and Current Standards... Class S, IEC62586-1 (PQI-S device) Power IEEE 1459 Power Quality Compliance 1738 or 1736 with pre-shared key Bluetooth read auxiliary measurement data from Fluke Connect 3000 series modules (requires WiFi/BLE adapter USB1 FC) USB-mini ... WiFi Supported modes Direct connection and connection to PC Extension port Accessories 7
Calibration Manual
Page 14
1736/1738 Calibration Manual Accuracy at ... A 300 A 3000 A 600 A 6000 A 4 A 40 A 42.5 Hz to 69 Hz 10 Vdc 1000 V defined by accessory 1000 % 1000 % 1000 % 100 % 0.1 V 0.01 mV 0.1 mV 0.01 mV 0.1 mV 0.01 A 0.1 A 1 A 10 A 1 A 10 ...A 1 mA 10 mA 0.01 Hz 0.1 mV 0.1 V defined by accessory 0.1 % 0.1 % 0.1 % 0.1 % ±(0.2 % + 0.01 %) ±(0.3 % + 0.02 %) ±(0.3 % + 0.02 %) ±(0.2 % + 0.02 %) ±(0.2 % + 0.02 %) ±(1 % + 0.02 %) ±(1 % + 0.02 %) ±(1 % + 0.03 %) ±(1 % + 0.03...
1736/1738 Calibration Manual Accuracy at ... A 300 A 3000 A 600 A 6000 A 4 A 40 A 42.5 Hz to 69 Hz 10 Vdc 1000 V defined by accessory 1000 % 1000 % 1000 % 100 % 0.1 V 0.01 mV 0.1 mV 0.01 mV 0.1 mV 0.01 A 0.1 A 1 A 10 A 1 A 10 ...A 1 mA 10 mA 0.01 Hz 0.1 mV 0.1 V defined by accessory 0.1 % 0.1 % 0.1 % 0.1 % ±(0.2 % + 0.01 %) ±(0.3 % + 0.02 %) ±(0.3 % + 0.02 %) ±(0.2 % + 0.02 %) ±(0.2 % + 0.02 %) ±(1 % + 0.02 %) ±(1 % + 0.02 %) ±(1 % + 0.03 %) ±(1 % + 0.03...
Calibration Manual
Page 17
...8 hcf060.eps Ref. American, Europe, UK, Australia, Japan, India/S. Power Logger Maintenance Replacement Parts Replacement parts and accessories are listed in Table 2. To order parts and accessories, see How to Contact Fluke. Table 2. Description Qty. Africa, Brazil) 1 varies Test Leads 0.1 m Red/Black, 1000 V CAT... Color-coded Wire Clips 1 set 4394925 USB Flash Drive (includes User Manuals and installer for PC software) 1 NA 11 Fluke Part or Model Number Power Supply 1 4743446 Battery Door 1 4388072 Battery Pack, Li ion 3.7 ...
...8 hcf060.eps Ref. American, Europe, UK, Australia, Japan, India/S. Power Logger Maintenance Replacement Parts Replacement parts and accessories are listed in Table 2. To order parts and accessories, see How to Contact Fluke. Table 2. Description Qty. Africa, Brazil) 1 varies Test Leads 0.1 m Red/Black, 1000 V CAT... Color-coded Wire Clips 1 set 4394925 USB Flash Drive (includes User Manuals and installer for PC software) 1 NA 11 Fluke Part or Model Number Power Supply 1 4743446 Battery Door 1 4388072 Battery Pack, Li ion 3.7 ...
Calibration Manual
Page 25
..., or Low. Click on the instrument, the settings High and Low can configure phase mapping, invert current inputs, and set to AUTO, the attached accessory determines the configuration. 19 When set the hardware range/mode of available COM ports. Dashboard Power Logger Setup The Dashboard sheet provides all other sheets...
..., or Low. Click on the instrument, the settings High and Low can configure phase mapping, invert current inputs, and set to AUTO, the attached accessory determines the configuration. 19 When set the hardware range/mode of available COM ports. Dashboard Power Logger Setup The Dashboard sheet provides all other sheets...
Calibration Manual
Page 28
... Verification in procedures to keep the applied values for current verification. Configure the resistor values, R1 and R2, of the accessory. Use DIRECT for calibration. Store the Excel workbook to verify and adjust the Logger. This divider, (see ...5520A uses a divider with a 50 Ω output impedance when sourcing Select Voltage, AUX Input or Current input for the Fluke Logger verification. Calibration items - The Verification uses an external divider. 1736/1738 Calibration Manual Table 9. Otherwise select Manual. Voltage Divider setup -
... Verification in procedures to keep the applied values for current verification. Configure the resistor values, R1 and R2, of the accessory. Use DIRECT for calibration. Store the Excel workbook to verify and adjust the Logger. This divider, (see ...5520A uses a divider with a 50 Ω output impedance when sourcing Select Voltage, AUX Input or Current input for the Fluke Logger verification. Calibration items - The Verification uses an external divider. 1736/1738 Calibration Manual Table 9. Otherwise select Manual. Voltage Divider setup -