Fluke ScopeMeter Product Datasheet
Page 2
... 1000 V independently floating isolated inputs for 1000 V CAT II and 600 V CAT III safety certification • Four hours rechargeable NiMH battery pack See an on an analog scope • F ast display update rate for detailed signal analysis. like on -line demonstration, go...and initiate a new waveform acquisition, a most useful capability when making adjustments to www.fluke.com/scopemeter High sampling rates give you 're looking at the display of a high-performance oscilloscope in a handheld, battery powered instrument. • Dual-input - 200, 100 or 60 MHz bandwidth ...
... 1000 V independently floating isolated inputs for 1000 V CAT II and 600 V CAT III safety certification • Four hours rechargeable NiMH battery pack See an on an analog scope • F ast display update rate for detailed signal analysis. like on -line demonstration, go...and initiate a new waveform acquisition, a most useful capability when making adjustments to www.fluke.com/scopemeter High sampling rates give you 're looking at the display of a high-performance oscilloscope in a handheld, battery powered instrument. • Dual-input - 200, 100 or 60 MHz bandwidth ...
Fluke ScopeMeter Product Datasheet
Page 4
... the ScopeMeter 120 Series has Connect-and-View automatic triggering. Scope mode With bandwidth of 20 MHz (Fluke 123) or 40 MHz (Fluke 124, 125) the Fluke 120 Series will capture and display almost any waveform found industrial network types are supported! • ... Power measurements for the maintenance engineer who deals with industrial machinery and the industrial network connecting his plant processing equipment and machinery. Battery ...
... the ScopeMeter 120 Series has Connect-and-View automatic triggering. Scope mode With bandwidth of 20 MHz (Fluke 123) or 40 MHz (Fluke 124, 125) the Fluke 120 Series will capture and display almost any waveform found industrial network types are supported! • ... Power measurements for the maintenance engineer who deals with industrial machinery and the industrial network connecting his plant processing equipment and machinery. Battery ...
Fluke ScopeMeter Product Datasheet
Page 5
... Save set-ups and screens True-rms multimeter Safety, Power and Warranty Safety (EN61010-1) Battery Line power PC and printer interface Warranty 190C ScopeMeter Series 190B ScopeMeter Series 120 Series Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Fluke 125 Fluke 124 Fluke 123 200 MHz 100 MHz 200 MHz 100 MHz 60 MHz 40 MHz 40 MHz...
... Save set-ups and screens True-rms multimeter Safety, Power and Warranty Safety (EN61010-1) Battery Line power PC and printer interface Warranty 190C ScopeMeter Series 190B ScopeMeter Series 120 Series Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Fluke 125 Fluke 124 Fluke 123 200 MHz 100 MHz 200 MHz 100 MHz 60 MHz 40 MHz 40 MHz...
Fluke 123 and 124 Scopemeter Datasheet
Page 1
... and capacitance measurements • Full bandwidth, heavy duty 10:1 probe included standard with Fluke 124 • Up to five hours battery operation with standard battery, seven hours with optional battery (Included with a fast answers wherever you to the cause of every dimension. Fluke's unique Connect-and-View recognizes signal patterns, and automatically sets up to 16...
... and capacitance measurements • Full bandwidth, heavy duty 10:1 probe included standard with Fluke 124 • Up to five hours battery operation with standard battery, seven hours with optional battery (Included with a fast answers wherever you to the cause of every dimension. Fluke's unique Connect-and-View recognizes signal patterns, and automatically sets up to 16...
FE 123 & 124 Users Manual
Page 3
...AB, Almelo, The Netherlands This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which is held invalid or unenforceable by misuse, alteration, accident or abnormal condition ...of operation or handling, Fluke will operate substantially in transit. Warranty support is available if product is submitted ...
...AB, Almelo, The Netherlands This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which is held invalid or unenforceable by misuse, alteration, accident or abnormal condition ...of operation or handling, Fluke will operate substantially in transit. Warranty support is available if product is submitted ...
FE 123 & 124 Users Manual
Page 6
Fluke 123/124 Users Manual Freezing the Screen...16 Holding a Stable Reading 16 Making Relative Measurements 17 Selecting Auto/Manual Ranges 18 Changing the Graphic Representation on the ... Tool 43 About this Chapter ...43 Cleaning the Test Tool 43 Storing the Test Tool...43 Charging the Rechargeable Battery Pack 44 Keeping Batteries in Optimal Condition 45 Replacing and Disposing of the Rechargeable Battery Pack 46 Using and Adjusting 10:1 Scope Probes 47 Calibrating the Test Tool 49 Parts and Accessories 49...
Fluke 123/124 Users Manual Freezing the Screen...16 Holding a Stable Reading 16 Making Relative Measurements 17 Selecting Auto/Manual Ranges 18 Changing the Graphic Representation on the ... Tool 43 About this Chapter ...43 Cleaning the Test Tool 43 Storing the Test Tool...43 Charging the Rechargeable Battery Pack 44 Keeping Batteries in Optimal Condition 45 Replacing and Disposing of the Rechargeable Battery Pack 46 Using and Adjusting 10:1 Scope Probes 47 Calibrating the Test Tool 49 Parts and Accessories 49...
FE 123 & 124 Users Manual
Page 7
Contents (continued) Goal of this Chapter ...53 Using the Tilt Stand...53 Resetting the Test Tool 54 Changing the Information Language 54 Changing the Display ...55 Changing Date and Time 56 Saving Battery Life ...57 Changing the Auto Set Options 58 Using Proper Grounding 59 Solving Printing and Other Communication Errors 60 Battery Testing of Fluke Accessories 60 4 Specifications...61 Introduction ...61 Dual Input Oscilloscope 62 Dual Input Meter...65 Cursor readout (Fluke 124 68 Miscellaneous ...69 Environmental ...70 Safety ...70 iii
Contents (continued) Goal of this Chapter ...53 Using the Tilt Stand...53 Resetting the Test Tool 54 Changing the Information Language 54 Changing the Display ...55 Changing Date and Time 56 Saving Battery Life ...57 Changing the Auto Set Options 58 Using Proper Grounding 59 Solving Printing and Other Communication Errors 60 Battery Testing of Fluke Accessories 60 4 Specifications...61 Introduction ...61 Dual Input Oscilloscope 62 Dual Input Meter...65 Cursor readout (Fluke 124 68 Miscellaneous ...69 Environmental ...70 Safety ...70 iii
FE 123 & 124 Users Manual
Page 10
...NiCd 2x) • • • • • Fluke 124 Model 124 NiMH 1x • Fluke 124/S Model 124 NiMH 2x) • • 2 Fluke 123/124 Users Manual Unpacking the Test Tool Kit The following items are included in your test tool kit. (see Figure 1.): # Description 1 Fluke Test Tool 2 Rechargeable Battery Pack 3 Power Adapter/Battery Charger 4 Shielded Test Leads with Black Ground... Isolated RS-232 Adapter/Cable 13 FlukeView ScopeMeter Software for Windows 14 Hard Carrying Case 15 10:1 Voltage Probe Note When new, the rechargeable battery pack is not fully charged.
...NiCd 2x) • • • • • Fluke 124 Model 124 NiMH 1x • Fluke 124/S Model 124 NiMH 2x) • • 2 Fluke 123/124 Users Manual Unpacking the Test Tool Kit The following items are included in your test tool kit. (see Figure 1.): # Description 1 Fluke Test Tool 2 Rechargeable Battery Pack 3 Power Adapter/Battery Charger 4 Shielded Test Leads with Black Ground... Isolated RS-232 Adapter/Cable 13 FlukeView ScopeMeter Software for Windows 14 Hard Carrying Case 15 10:1 Voltage Probe Note When new, the rechargeable battery pack is not fully charged.
FE 123 & 124 Users Manual
Page 12
... not being detected. This ensures that the full signal content is measured. Warning To avoid electrical shock, use only Fluke power supply, Model PM8907 (Power Adapter/Battery Charger). 4 See explanation in the next table. This can result in fully automatic mode. To guarantee user safety, ...all signals should first be found throughout the manual. Fluke 123/124 Users Manual Safely Using the Test Tool Attention Carefully read...
... not being detected. This ensures that the full signal content is measured. Warning To avoid electrical shock, use only Fluke power supply, Model PM8907 (Power Adapter/Battery Charger). 4 See explanation in the next table. This can result in fully automatic mode. To guarantee user safety, ...all signals should first be found throughout the manual. Fluke 123/124 Users Manual Safely Using the Test Tool Attention Carefully read...
FE 123 & 124 Users Manual
Page 13
... PM8907 matches the local line power voltage and frequency. • For the PM8907/808 universal Battery Charger/Power Adapter use only line cords that comply with the Test Tool, or indicated as suitable for the Fluke 123/124 Test Tool. • Before use, inspect voltage probes, test leads and accessories for local use...
... PM8907 matches the local line power voltage and frequency. • For the PM8907/808 universal Battery Charger/Power Adapter use only line cords that comply with the Test Tool, or indicated as suitable for the Fluke 123/124 Test Tool. • Before use, inspect voltage probes, test leads and accessories for local use...
FE 123 & 124 Users Manual
Page 15
Goal of the test tool but gives basic examples to show how to use the menus perform basic operations. Powering the Test Tool Follow the procedure (step 1 to 3) in its last setup configuration. Chapter 1 Using The Test Tool Figure 1-1. See Chapter 2 for battery power instructions. Turn the test tool on. Powering the Test Tool 7 The introduction does not cover all of the capabilities of this Chapter This Chapter provides a step-by-step introduction to power the test tool from a standard ac outlet. The test tool powers up in Figure 1-1 to the test tool.
Goal of the test tool but gives basic examples to show how to use the menus perform basic operations. Powering the Test Tool Follow the procedure (step 1 to 3) in its last setup configuration. Chapter 1 Using The Test Tool Figure 1-1. See Chapter 2 for battery power instructions. Turn the test tool on. Powering the Test Tool 7 The introduction does not cover all of the capabilities of this Chapter This Chapter provides a step-by-step introduction to power the test tool from a standard ac outlet. The test tool powers up in Figure 1-1 to the test tool.
FE 123 & 124 Users Manual
Page 17
.... 1 Using The Test Tool Changing Backlight In Fluke 124, do the following : Press to get access to the display functions. Note Using dimmed display lengthens maximum battery power operation time. To change the brightness of the display in Fluke 123, do the following : Dim the backlight.... To save battery power, the screen has an economic brightness display when operated on the battery pack (no power adapter connected...
.... 1 Using The Test Tool Changing Backlight In Fluke 124, do the following : Press to get access to the display functions. Note Using dimmed display lengthens maximum battery power operation time. To change the brightness of the display in Fluke 123, do the following : Dim the backlight.... To save battery power, the screen has an economic brightness display when operated on the battery pack (no power adapter connected...
FE 123 & 124 Users Manual
Page 18
... the numeric readings. When you change a setup, a part of the battery from full to Figure 1-3 during the following. The area displays one or more menus with choices accessed with the arrow keys: . 10 Fluke 123 Fluke 124 Figure 1-3. The bottom line displays the ranges/div and the power indicator... (line or battery). Because only input A is divided into three areas: Reading area, Waveform area, and Menu ...
... the numeric readings. When you change a setup, a part of the battery from full to Figure 1-3 during the following. The area displays one or more menus with choices accessed with the arrow keys: . 10 Fluke 123 Fluke 124 Figure 1-3. The bottom line displays the ranges/div and the power indicator... (line or battery). Because only input A is divided into three areas: Reading area, Waveform area, and Menu ...
FE 123 & 124 Users Manual
Page 51
... before storing. Cleaning the Test Tool Clean the test tool with a damp cloth and a mild soap to remove the battery pack. 43 Do not use abrasives, solvents, or alcohol. For complete service, disassembly, repair, and calibration information, see the Service Manual. Storing the Test Tool ...
... before storing. Cleaning the Test Tool Clean the test tool with a damp cloth and a mild soap to remove the battery pack. 43 Do not use abrasives, solvents, or alcohol. For complete service, disassembly, repair, and calibration information, see the Service Manual. Storing the Test Tool ...
FE 123 & 124 Users Manual
Page 52
... the weekend. 44 Figure 2-1. When battery powered, the battery indicator on the bottom of the screen informs you leave it charging for Fluke 124 (Ni-MH battery). Turn the test tool off ) to charge the battery pack and power the instrument. The battery symbol indicates that there are : .... Use the setup as shown in Fluke 124 at normal brightness. The battery symbols are typically five ...
... the weekend. 44 Figure 2-1. When battery powered, the battery indicator on the bottom of the screen informs you leave it charging for Fluke 124 (Ni-MH battery). Turn the test tool off ) to charge the battery pack and power the instrument. The battery symbol indicates that there are : .... Use the setup as shown in Fluke 124 at normal brightness. The battery symbols are typically five ...
FE 123 & 124 Users Manual
Page 53
... about 14 hours (Fluke 123 with Ni-Cd battery) or 19 hours (Fluke 124 with Ni-MH battery) and should be black.The backlight is line powered. Open the USER OPTIONS menu. Open the BATTERY REFRESH submenu. This battery refresh cycle fully discharges and charges the battery pack. Highlight START REFRESH...icon appears on during the complete refresh cycle. Start the refresh cycle. Keeping Batteries in Optimal Condition To refresh the battery pack, do the following: • Be sure that the batteries need to disconnect the Power Adapter during discharging within the refresh cycle. 45 ...
... about 14 hours (Fluke 123 with Ni-Cd battery) or 19 hours (Fluke 124 with Ni-MH battery) and should be black.The backlight is line powered. Open the USER OPTIONS menu. Open the BATTERY REFRESH submenu. This battery refresh cycle fully discharges and charges the battery pack. Highlight START REFRESH...icon appears on during the complete refresh cycle. Start the refresh cycle. Keeping Batteries in Optimal Condition To refresh the battery pack, do the following: • Be sure that the batteries need to disconnect the Power Adapter during discharging within the refresh cycle. 45 ...
FE 123 & 124 Users Manual
Page 54
....This ensures information stored in memories will not be disposed of this battery pack with a flat-blade screwdriver. 46 Figure 2-2. Remove the battery plug from the test tool. 5. Contact your authorized FLUKE Service Center for recycling information. Disconnect the test leads and probes both... at the source and at the test tool. 2. Install a new battery pack. Fluke 123/124 Users Manual Replacing and Disposing of the battery compartment. 6. Loosen the screw with other solid waste. Do not dispose of by a qualified recycler or hazardous...
....This ensures information stored in memories will not be disposed of this battery pack with a flat-blade screwdriver. 46 Figure 2-2. Remove the battery plug from the test tool. 5. Contact your authorized FLUKE Service Center for recycling information. Disconnect the test leads and probes both... at the source and at the test tool. 2. Install a new battery pack. Fluke 123/124 Users Manual Replacing and Disposing of the battery compartment. 6. Loosen the screw with other solid waste. Do not dispose of by a qualified recycler or hazardous...
FE 123 & 124 Users Manual
Page 55
...-to-BNC adapter (delivered with the test tool) to connect a 10:1 scope probe to the red input A jack. Adjusting Scope Probes 47 For Fluke 124 it is placed in the battery compartment as shown in Figure 2-2. VPS100, optional) for optimal response. BB120 Figure 2-3. To adjust probes, do the following: 2 Maintaining the Test Tool...
...-to-BNC adapter (delivered with the test tool) to connect a 10:1 scope probe to the red input A jack. Adjusting Scope Probes 47 For Fluke 124 it is placed in the battery compartment as shown in Figure 2-2. VPS100, optional) for optimal response. BB120 Figure 2-3. To adjust probes, do the following: 2 Maintaining the Test Tool...
FE 123 & 124 Users Manual
Page 57
... The next tables list the user-replaceable parts for recalibration. 49 Return to normal mode. To order replacement parts, contact your local Fluke representative for the various test tool models. To display the identity, do the following: Open the USER OPTIONS menu. Contact your nearest.... The screen gives you information about the model number with software version, the calibration number with latest calibration date, and the latest battery refresh date. Calibrating the Test Tool You can ask for the model identity (version and calibration data) at any time. Recalibration must...
... The next tables list the user-replaceable parts for recalibration. 49 Return to normal mode. To order replacement parts, contact your local Fluke representative for the various test tool models. To display the identity, do the following: Open the USER OPTIONS menu. Contact your nearest.... The screen gives you information about the model number with software version, the calibration number with latest calibration date, and the latest battery refresh date. Calibrating the Test Tool You can ask for the model identity (version and calibration data) at any time. Recalibration must...
FE 123 & 124 Users Manual
Page 58
...the PM8907/808 is not for North America. The 230 V rating of two Shielded Test Leads (Red and Gray), designed for use in Fluke 124, 124/S) Power Adapter/Battery Charger, available models: Universal Europe 230V, 50Hz North America 120V, 60Hz United Kingdom 240V, 50Hz Japan 100V, 60Hz Australia 240V, 50Hz ... part: Ground Lead with UL listed line plug adapter for use only with the applicable National Requirements must be used. Fluke 123/124 Users Manual Standard Accessories (cont) Item Ni-Cd Battery Pack (installed in Fluke 123, 123/S) Ni-MH Battery Pack (installed in North America.
...the PM8907/808 is not for North America. The 230 V rating of two Shielded Test Leads (Red and Gray), designed for use in Fluke 124, 124/S) Power Adapter/Battery Charger, available models: Universal Europe 230V, 50Hz North America 120V, 60Hz United Kingdom 240V, 50Hz Japan 100V, 60Hz Australia 240V, 50Hz ... part: Ground Lead with UL listed line plug adapter for use only with the applicable National Requirements must be used. Fluke 123/124 Users Manual Standard Accessories (cont) Item Ni-Cd Battery Pack (installed in Fluke 123, 123/S) Ni-MH Battery Pack (installed in North America.