Fluke ScopeMeter Product Datasheet
Page 2
...On-screen color labels, measurements and warnings are clearly linked to specific waveforms. See dynamic signal behavior instantaneously The Digital Persistence mode (Fluke 190C) helps to find tiny details in a long waveform, for troubleshooting time relationships between a high-resolution color display (190C Series)...• D igital Persistence mode for 1000 V CAT II and 600 V CAT III safety certification • Four hours rechargeable NiMH battery pack See an on-line demonstration, go to capture the eye-pattern on Fast Fourier Transformation (FFT) analysis as if you may manually ...
...On-screen color labels, measurements and warnings are clearly linked to specific waveforms. See dynamic signal behavior instantaneously The Digital Persistence mode (Fluke 190C) helps to find tiny details in a long waveform, for troubleshooting time relationships between a high-resolution color display (190C Series)...• D igital Persistence mode for 1000 V CAT II and 600 V CAT III safety certification • Four hours rechargeable NiMH battery pack See an on-line demonstration, go to capture the eye-pattern on Fast Fourier Transformation (FFT) analysis as if you may manually ...
Fluke ScopeMeter Product Datasheet
Page 5
...Fluke 125 and Fluke 124) Detailed technical specifications and optional accessories can be found in the technical datasheet or on standard accessories (1) Maximum input voltage 1000 V CAT II with VPS40, 40 MHz, 10:1 Voltage Probe (standard included with a complete accessory package including line voltage adapter and battery pack... Warranty Safety (EN61010-1) Battery Line power PC and printer interface Warranty 190C ScopeMeter Series 190B ScopeMeter Series 120 Series Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Fluke 125 Fluke 124 Fluke 123 200 MHz 100 MHz 200...
...Fluke 125 and Fluke 124) Detailed technical specifications and optional accessories can be found in the technical datasheet or on standard accessories (1) Maximum input voltage 1000 V CAT II with VPS40, 40 MHz, 10:1 Voltage Probe (standard included with a complete accessory package including line voltage adapter and battery pack... Warranty Safety (EN61010-1) Battery Line power PC and printer interface Warranty 190C ScopeMeter Series 190B ScopeMeter Series 120 Series Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Fluke 125 Fluke 124 Fluke 123 200 MHz 100 MHz 200...
FE 123 & 124 Users Manual
Page 6
Fluke 123/124 Users Manual Freezing the Screen...16 Holding a Stable Reading 16 Making Relative Measurements 17 Selecting Auto/Manual Ranges 18 Changing the Graphic Representation on ... Tool 43 About this Chapter ...43 Cleaning the Test Tool 43 Storing the Test Tool...43 Charging the Rechargeable Battery Pack 44 Keeping Batteries in Optimal Condition 45 Replacing and Disposing of the Rechargeable Battery Pack 46 Using and Adjusting 10:1 Scope Probes 47 Calibrating the Test Tool 49 Parts and Accessories 49 3 Tips and...
Fluke 123/124 Users Manual Freezing the Screen...16 Holding a Stable Reading 16 Making Relative Measurements 17 Selecting Auto/Manual Ranges 18 Changing the Graphic Representation on ... Tool 43 About this Chapter ...43 Cleaning the Test Tool 43 Storing the Test Tool...43 Charging the Rechargeable Battery Pack 44 Keeping Batteries in Optimal Condition 45 Replacing and Disposing of the Rechargeable Battery Pack 46 Using and Adjusting 10:1 Scope Probes 47 Calibrating the Test Tool 49 Parts and Accessories 49 3 Tips and...
FE 123 & 124 Users Manual
Page 10
...Fluke 123 Model 123 NiCd 1x Fluke 123/S Model 123 NiCd 2x) • • • • • Fluke 124 Model 124 NiMH 1x • Fluke 124/S Model 124 NiMH 2x) • • 2 Fluke 123/124 Users Manual Unpacking the Test Tool Kit The following items are included in your test tool kit. (see Figure 1.): # Description 1 Fluke Test Tool 2 Rechargeable Battery Pack 3 Power Adapter/Battery... RS-232 Adapter/Cable 13 FlukeView ScopeMeter Software for Windows 14 Hard Carrying Case 15 10:1 Voltage Probe Note When new, the rechargeable battery pack is not fully charged.
...Fluke 123 Model 123 NiCd 1x Fluke 123/S Model 123 NiCd 2x) • • • • • Fluke 124 Model 124 NiMH 1x • Fluke 124/S Model 124 NiMH 2x) • • 2 Fluke 123/124 Users Manual Unpacking the Test Tool Kit The following items are included in your test tool kit. (see Figure 1.): # Description 1 Fluke Test Tool 2 Rechargeable Battery Pack 3 Power Adapter/Battery... RS-232 Adapter/Cable 13 FlukeView ScopeMeter Software for Windows 14 Hard Carrying Case 15 10:1 Voltage Probe Note When new, the rechargeable battery pack is not fully charged.
FE 123 & 124 Users Manual
Page 17
...high brightness increases when you connect the power adapter. . 9 Note Using dimmed display lengthens maximum battery power operation time. To change the brightness of the display in Fluke 123, do the following : Dim the backlight. Select LIGHT Dim or brighten the backlight. Changing Backlight... After power-up, the screen has a high bright display. To save battery power, the screen has an economic brightness display when operated on the battery pack (no power...
...high brightness increases when you connect the power adapter. . 9 Note Using dimmed display lengthens maximum battery power operation time. To change the brightness of the display in Fluke 123, do the following : Dim the backlight. Select LIGHT Dim or brighten the backlight. Changing Backlight... After power-up, the screen has a high bright display. To save battery power, the screen has an economic brightness display when operated on the battery pack (no power...
FE 123 & 124 Users Manual
Page 51
... avoid abrasion of text on the test tool. Cleaning the Test Tool Clean the test tool with a damp cloth and a mild soap to remove the battery pack. 43 Do not use abrasives, solvents, or alcohol. Chapter 2 Maintaining the Test Tool About this manual. For complete service, disassembly, repair, and calibration information, see...
... avoid abrasion of text on the test tool. Cleaning the Test Tool Clean the test tool with a damp cloth and a mild soap to remove the battery pack. 43 Do not use abrasives, solvents, or alcohol. Chapter 2 Maintaining the Test Tool About this manual. For complete service, disassembly, repair, and calibration information, see...
FE 123 & 124 Users Manual
Page 52
.... Operating time is extended at full brightness. Fluke 123/124 Users Manual Charging the Rechargeable Battery Pack At delivery, the batteries may be empty and must be charged (test tool is off to charge the batteries more quickly. Charging the Battery Pack When battery powered, the battery indicator on the bottom of the battery. Note The test tool uses a trickle charge...
.... Operating time is extended at full brightness. Fluke 123/124 Users Manual Charging the Rechargeable Battery Pack At delivery, the batteries may be empty and must be charged (test tool is off to charge the batteries more quickly. Charging the Battery Pack When battery powered, the battery indicator on the bottom of the battery. Note The test tool uses a trickle charge...
FE 123 & 124 Users Manual
Page 53
Frequent charging of the screen. A complete refresh cycle takes about 14 hours (Fluke 123 with Ni-Cd battery) or 19 hours (Fluke 124 with Ni-MH battery) and should be recharged. Open the USER OPTIONS menu. Keeping Batteries in Optimal Condition To refresh the battery pack, do the following: • Be sure that the test tool is line powered...
Frequent charging of the screen. A complete refresh cycle takes about 14 hours (Fluke 123 with Ni-Cd battery) or 19 hours (Fluke 124 with Ni-MH battery) and should be recharged. Open the USER OPTIONS menu. Keeping Batteries in Optimal Condition To refresh the battery pack, do the following: • Be sure that the test tool is line powered...
FE 123 & 124 Users Manual
Page 54
... leads and probes both at the source and at the test tool. 2. Install a new battery pack. To replace the battery pack, do the following: (See Figure 2-2.) 1. Fluke 123/124 Users Manual Replacing and Disposing of the battery compartment. 6. Do not dispose of this battery pack with the Power Adapter.This ensures information stored in memories will not be disposed...
... leads and probes both at the source and at the test tool. 2. Install a new battery pack. To replace the battery pack, do the following: (See Figure 2-2.) 1. Fluke 123/124 Users Manual Replacing and Disposing of the battery compartment. 6. Do not dispose of this battery pack with the Power Adapter.This ensures information stored in memories will not be disposed...
FE 123 & 124 Users Manual
Page 55
... tool) to connect a 10:1 scope probe to -BNC adapter (BB120). Warning To avoid electrical shock use the Fluke BP130 Ni-MH battery pack . 8. See Figure 2-3. Reinstall the battery cover and secure the screw. Adjusting Scope Probes 47 Use the red 4-mm banana adapter (delivered with... Test Tool and needs no further adjustment. VPS100, optional) for optimal response. BB120 Figure 2-3. For Fluke 123 use the Fluke BP120 Ni-Cd (standard) or BP130 Ni-MH (extended operating time) battery pack. You need to the red input A jack. To adjust probes, do the following: 2 Maintaining...
... tool) to connect a 10:1 scope probe to -BNC adapter (BB120). Warning To avoid electrical shock use the Fluke BP130 Ni-MH battery pack . 8. See Figure 2-3. Reinstall the battery cover and secure the screw. Adjusting Scope Probes 47 Use the red 4-mm banana adapter (delivered with... Test Tool and needs no further adjustment. VPS100, optional) for optimal response. BB120 Figure 2-3. For Fluke 123 use the Fluke BP120 Ni-Cd (standard) or BP130 Ni-MH (extended operating time) battery pack. You need to the red input A jack. To adjust probes, do the following: 2 Maintaining...
FE 123 & 124 Users Manual
Page 58
.../808 is not for North America. The 230 V rating of two Shielded Test Leads (Red and Gray), designed for use in Fluke 124, 124/S) Power Adapter/Battery Charger, available models: Universal Europe 230V, 50Hz North America 120V, 60Hz United Kingdom 240V, 50Hz Japan 100V, 60Hz Australia 240V, ... STL120 5322 320 11354 50 Set contains the following replaceable part: Ground Lead with the applicable National Requirements must be used. Fluke 123/124 Users Manual Standard Accessories (cont) Item Ni-Cd Battery Pack (installed in Fluke 123, 123/S) Ni-MH Battery Pack (installed in North America.
.../808 is not for North America. The 230 V rating of two Shielded Test Leads (Red and Gray), designed for use in Fluke 124, 124/S) Power Adapter/Battery Charger, available models: Universal Europe 230V, 50Hz North America 120V, 60Hz United Kingdom 240V, 50Hz Japan 100V, 60Hz Australia 240V, ... STL120 5322 320 11354 50 Set contains the following replaceable part: Ground Lead with the applicable National Requirements must be used. Fluke 123/124 Users Manual Standard Accessories (cont) Item Ni-Cd Battery Pack (installed in Fluke 123, 123/S) Ni-MH Battery Pack (installed in North America.
FE 123 & 124 Users Manual
Page 65
... power shutdown will not occur if TrendPlot is not jeopardized. Accept the new power down . Recording will continue even if the battery pack is low, and retention of memories is on the battery pack (no automatic power shutdown. To set to five minutes, do the following: Open the USER OPTIONS menu. Saving... Battery Life When operated on , the backlight will dim. If you have not pressed a key for at least 30 minutes, the test...
... power shutdown will not occur if TrendPlot is not jeopardized. Accept the new power down . Recording will continue even if the battery pack is low, and retention of memories is on the battery pack (no automatic power shutdown. To set to five minutes, do the following: Open the USER OPTIONS menu. Saving... Battery Life When operated on , the backlight will dim. If you have not pressed a key for at least 30 minutes, the test...
FE 123 & 124 Users Manual
Page 77
... Power External via Power Adapter PM8907 Input Voltage 10 to 21V DC Power 5W typical Input Connector 5 mm jack Fluke 123 (Internal Battery Pack BP120): Battery Power Rechargeable Ni-Cd 4.8V Operating Time 4 hours with bright backlight 4.25 hours with dimmed backlight Charging Time ...(32 to 113 °F) Memory Number of Screen + Setup Memories (Fluke 123) .... 10 Number of Screen + Setup Memories (Fluke 124) .... 20 Mechanical Size 232 x 115 x 50 mm (9.1 x 4.5 x 2 in) Weight 1.2 kg (2.5 lbs) including battery pack Interface RS-232, optically isolated To Printer supports Epson FX, LQ, ...
... Power External via Power Adapter PM8907 Input Voltage 10 to 21V DC Power 5W typical Input Connector 5 mm jack Fluke 123 (Internal Battery Pack BP120): Battery Power Rechargeable Ni-Cd 4.8V Operating Time 4 hours with bright backlight 4.25 hours with dimmed backlight Charging Time ...(32 to 113 °F) Memory Number of Screen + Setup Memories (Fluke 123) .... 10 Number of Screen + Setup Memories (Fluke 124) .... 20 Mechanical Size 232 x 115 x 50 mm (9.1 x 4.5 x 2 in) Weight 1.2 kg (2.5 lbs) including battery pack Interface RS-232, optically isolated To Printer supports Epson FX, LQ, ...
FE 123 & 124 Users Manual
Page 83
..., 9 Banana Jack Inputs, 12 Banana-to-BNC Adapter, 51 Bandwidth, 62 Battery Charger, 50 Battery Disposing, 46 Battery Indicator, 10 Battery Life, 57 Battery Pack, 2, 44, 50 Battery Power, 69 Battery Refresh Date, 49 Battery Replacing, 46 BB120 Adapters, 51 Blue Function Keys, 10 BP120 Battery Pack, 47, 50 BP130 Battery Pack, 47, 50 Bright Display, 9 -C- Index -A- AC coupling, 4 AC120 Alligator Clips, 51...
..., 9 Banana Jack Inputs, 12 Banana-to-BNC Adapter, 51 Bandwidth, 62 Battery Charger, 50 Battery Disposing, 46 Battery Indicator, 10 Battery Life, 57 Battery Pack, 2, 44, 50 Battery Power, 69 Battery Refresh Date, 49 Battery Replacing, 46 BB120 Adapters, 51 Blue Function Keys, 10 BP120 Battery Pack, 47, 50 BP130 Battery Pack, 47, 50 Bright Display, 9 -C- Index -A- AC coupling, 4 AC120 Alligator Clips, 51...
FE 123 & 124 Users Manual
Page 85
..., 8 Reversing the Polarity, 26 Rise Time, 62 Rise Time Measurements, 37 Roll Mode Function, 25 77 Floating Voltage, 6, 62, 70 Max. Ni-Cd Battery Pack, 2, 44, 50 Ni-MH Battery Pack, 2, 44 -O- Ohm (Ω), 14, 59, 67 Operating Time, 69 Optical Interface, 39, 41, 69 -P- Isolated, 6 Isolated Trigger Probe, 29, 52 Isolated Triggering, 29...
..., 8 Reversing the Polarity, 26 Rise Time, 62 Rise Time Measurements, 37 Roll Mode Function, 25 77 Floating Voltage, 6, 62, 70 Max. Ni-Cd Battery Pack, 2, 44, 50 Ni-MH Battery Pack, 2, 44 -O- Ohm (Ω), 14, 59, 67 Operating Time, 69 Optical Interface, 39, 41, 69 -P- Isolated, 6 Isolated Trigger Probe, 29, 52 Isolated Triggering, 29...