Specification sheet
Page 1
Dual-Fuel Freestanding Range E48DF76EPS professional series Smooth-Glide™...Included Included Optional Optional Optional Optional Optional SPECIFICATIONS Large Oven Cavity Dimensions - PN # KIKPLT48 Black Gas Valve Knob - Refer to Product Installation Guide for cooking multiple dishes at electroluxicon.com. Convenient...centered easy-grip handle make access to perfection has never been easier. 48" DUAL-FUEL FREESTANDING RANGE CONTROL PANEL FEATURES Electronic Oven Control Yes Professional-Style Stainless Steel Console Yes Large Professional Skirted Knobs with Bezel 10 RANGETOP...
Dual-Fuel Freestanding Range E48DF76EPS professional series Smooth-Glide™...Included Included Optional Optional Optional Optional Optional SPECIFICATIONS Large Oven Cavity Dimensions - PN # KIKPLT48 Black Gas Valve Knob - Refer to Product Installation Guide for cooking multiple dishes at electroluxicon.com. Convenient...centered easy-grip handle make access to perfection has never been easier. 48" DUAL-FUEL FREESTANDING RANGE CONTROL PANEL FEATURES Electronic Oven Control Yes Professional-Style Stainless Steel Console Yes Large Professional Skirted Knobs with Bezel 10 RANGETOP...
Specification sheet
Page 2
Dual-Fuel Freestanding Range E48DF76EPS professional series 48" min. 30" min. to nearest combustible wall (either side of appliance must be no less than maximum width of appliance. • Allow 10" minimum clearance from edge of rangetop to nearest combustible wall on the web at Electrolux Home Products, ...of wood or metal overhead cabinet is protected by not less than 1/8" flame-retardant millboard covered with 3/4" factory regulator. • LP Gas conversion kit supplied. • Overhead cabinetry should not exceed a 13" maximum depth. • Allow 30" minimum clearance between top...
Dual-Fuel Freestanding Range E48DF76EPS professional series 48" min. 30" min. to nearest combustible wall (either side of appliance must be no less than maximum width of appliance. • Allow 10" minimum clearance from edge of rangetop to nearest combustible wall on the web at Electrolux Home Products, ...of wood or metal overhead cabinet is protected by not less than 1/8" flame-retardant millboard covered with 3/4" factory regulator. • LP Gas conversion kit supplied. • Overhead cabinetry should not exceed a 13" maximum depth. • Allow 30" minimum clearance between top...
Owners Guide
Page 6
... lift safely. Select utensils that are able to use the range. Immediately turn off the gas supply at the fuse or junction box and contact the gas supplier or qualified appliance technician. • Ensure that the range is off when you the location of the gas supply. Utilize a deep fat frying thermometer to avoid heating...
... lift safely. Select utensils that are able to use the range. Immediately turn off the gas supply at the fuse or junction box and contact the gas supplier or qualified appliance technician. • Ensure that the range is off when you the location of the gas supply. Utilize a deep fat frying thermometer to avoid heating...
Owners Guide
Page 8
... or hanging apparel while using the cooktop, do not touch the grates, burner caps, burner bases, or any part of interest to touch gas burners. Children could be burned or injured while climbing on any other parts in literature accompanying this appliance in any flames with a lid,... power failure. • Do not slide cookware across the grates. Do not use aerosol cleaners, as these may damage the finish of the range unless specifically recommended in proximity to use this appliance. Sliding may cause permanent damage. Venting from the oven may result. Do not use a towel...
... or hanging apparel while using the cooktop, do not touch the grates, burner caps, burner bases, or any part of interest to touch gas burners. Children could be burned or injured while climbing on any other parts in literature accompanying this appliance in any flames with a lid,... power failure. • Do not slide cookware across the grates. Do not use aerosol cleaners, as these may damage the finish of the range unless specifically recommended in proximity to use this appliance. Sliding may cause permanent damage. Venting from the oven may result. Do not use a towel...
Owners Guide
Page 9
... technician in serious injury or property damage. The qualified agency performing this work assumes responsibility for the conversion. Failure to the range may occur if the range is marked "FOR LP/PROPANE GAS CONVERSION". Follow the installation instructions which are inside the envelope. WARNING Severe shock, or damage to follow instructions could result...
... technician in serious injury or property damage. The qualified agency performing this work assumes responsibility for the conversion. Failure to the range may occur if the range is marked "FOR LP/PROPANE GAS CONVERSION". Follow the installation instructions which are inside the envelope. WARNING Severe shock, or damage to follow instructions could result...
Owners Guide
Page 12
All spills remain on the bottom of each gas burner base. 12 Cooktop Features SEALED BURNER CONFIGURATIONS On E30DF74EPS ranges, there are a total of six burners, including two burners rated at a maximum output of 17,000 BTU/HR, two burners rated at a maximum of 15,...000 BTU/HR and two burners rated at a maximum output of 8,500 BTU/HR. On E36DF76EPS and E48DF76EPS ranges, there are a total of four burners, including one burner rated at a maximum output of 17,000 BTU/HR, two burners rated at a maximum of 15...
All spills remain on the bottom of each gas burner base. 12 Cooktop Features SEALED BURNER CONFIGURATIONS On E30DF74EPS ranges, there are a total of six burners, including two burners rated at a maximum output of 17,000 BTU/HR, two burners rated at a maximum of 15,...000 BTU/HR and two burners rated at a maximum output of 8,500 BTU/HR. On E36DF76EPS and E48DF76EPS ranges, there are a total of four burners, including one burner rated at a maximum output of 17,000 BTU/HR, two burners rated at a maximum of 15...
Owners Guide
Page 18
18 Operation BEFORE COOKING Ensure that the gas and electrical power supplies to the range are operational. The brass burner rings, burner caps, grates, knobs and spill protectors must be in accordance with the Installation Instructions. Read this Use and ...will spark continuously until the gas ignites on the corresponding control knob, then immediately rotate the knob counterclockwise from the "OFF" position to operate properly. Once the burner is lit, reduce the flame height if desired by a qualified individual who has tested the operation of the range in place for the cooktop...
18 Operation BEFORE COOKING Ensure that the gas and electrical power supplies to the range are operational. The brass burner rings, burner caps, grates, knobs and spill protectors must be in accordance with the Installation Instructions. Read this Use and ...will spark continuously until the gas ignites on the corresponding control knob, then immediately rotate the knob counterclockwise from the "OFF" position to operate properly. Once the burner is lit, reduce the flame height if desired by a qualified individual who has tested the operation of the range in place for the cooktop...
Owners Guide
Page 44
... fuses, repair of White Consolidated Industries, Inc. Box 212378 Augusta, GA 30917 Canada 1•866•294•9911 Electrolux Home Products North America 802, boul. FULL ONE-YEAR WARRANTY WARRANTY PERIOD... THROUGH OUR AUTHORIZED SERVICERS, WE WILL: One year from the factory. 5. CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN OR ANY IMPLIED WARRANTY. 44 Warranty Information RANGE WARRANTY Y our range...
... fuses, repair of White Consolidated Industries, Inc. Box 212378 Augusta, GA 30917 Canada 1•866•294•9911 Electrolux Home Products North America 802, boul. FULL ONE-YEAR WARRANTY WARRANTY PERIOD... THROUGH OUR AUTHORIZED SERVICERS, WE WILL: One year from the factory. 5. CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN OR ANY IMPLIED WARRANTY. 44 Warranty Information RANGE WARRANTY Y our range...
Installation Instructions
Page 6
...Table 7 Electrical Power Supply Requirements 8 Gas and Electrical Rough-In 9 Cabinet/Counterop Preparation 10 Overal Dimensions 12 Installing the Anti-Tip Bracket 13 Gas Regulator and Electrical Conduit Location 16 Installation 17 Installing the Range Backguards 17 Removing the Door(s 18 Reinstalling... the Door(s 18 Making the Electrical Connection 19 Making the Gas Connection 22 Installing the Range 23 Installing the Burner...
...Table 7 Electrical Power Supply Requirements 8 Gas and Electrical Rough-In 9 Cabinet/Counterop Preparation 10 Overal Dimensions 12 Installing the Anti-Tip Bracket 13 Gas Regulator and Electrical Conduit Location 16 Installation 17 Installing the Range Backguards 17 Removing the Door(s 18 Reinstalling... the Door(s 18 Making the Electrical Connection 19 Making the Gas Connection 22 Installing the Range 23 Installing the Burner...
Installation Instructions
Page 7
...gas supply pressure E30DF74EPS 240-4 Wire VAC, 60Hz, 30A 26.4 Amps (6.3 Kw) Natural 4" Water Column 5" Water Column Liquid Propane 10" Water Column 11" Water Column 240-4 26.4 Amps Natural 4" Water Column 5" Water Column E36DF76EPS Wire VAC, (6.3 Kw) 60Hz, 30A Liquid Propane 10" Water Column 11" Water Column 240-4 E48DF76EPS... table below for use with the National Fuel Gas Code ANSI Z223.1. NOTE This range is also located on the serial number label on the range. The electrical information in accordance with natural gas. Preparing for Installation 7 VERIFY PACKAGE CONTENTS...
...gas supply pressure E30DF74EPS 240-4 Wire VAC, 60Hz, 30A 26.4 Amps (6.3 Kw) Natural 4" Water Column 5" Water Column Liquid Propane 10" Water Column 11" Water Column 240-4 26.4 Amps Natural 4" Water Column 5" Water Column E36DF76EPS Wire VAC, (6.3 Kw) 60Hz, 30A Liquid Propane 10" Water Column 11" Water Column 240-4 E48DF76EPS... table below for use with the National Fuel Gas Code ANSI Z223.1. NOTE This range is also located on the serial number label on the range. The electrical information in accordance with natural gas. Preparing for Installation 7 VERIFY PACKAGE CONTENTS...
Installation Instructions
Page 9
..., external to the appliance, for in place, must be caused by 24 inches (610mm) deep, with the range. Both the gas supply piping and shut-off gas to be sealed. Preparing for service when the conduit supplied with the unit is attached to the junction box. Do not lengthen the ...inches (914mm) high at the finished countertop by doors, windows and HVAC outlets. Any openings in the illustrations, denote the location of the range and the gas supply to allow access to the remote circuit breaker panel/fuse box, with the sides or rear of the existing utilities may be maintained...
..., external to the appliance, for in place, must be caused by 24 inches (610mm) deep, with the range. Both the gas supply piping and shut-off gas to be sealed. Preparing for service when the conduit supplied with the unit is attached to the junction box. Do not lengthen the ...inches (914mm) high at the finished countertop by doors, windows and HVAC outlets. Any openings in the illustrations, denote the location of the range and the gas supply to allow access to the remote circuit breaker panel/fuse box, with the sides or rear of the existing utilities may be maintained...
Installation Instructions
Page 17
...access panel or the back cover if the entire back cover was shipped with the range installation. Installing the Range Optional Backguard: 1. Connect the gas line to the range top. Remove the backguard from its box. 2. Fasten the provided screws through the... backguard will make contact. Installation 17 INSTALLING THE 30", 36" & 48" RANGE OPTIONAL BACKGUARDS Your Electrolux IconTM range was removed. 5. Figure 11 Figure 12 Backguard Installation (36" range shown) Backguard Installation (48" range shown) NOTE For 24" Backguards, fasten the provided screws through the rear...
...access panel or the back cover if the entire back cover was shipped with the range installation. Installing the Range Optional Backguard: 1. Connect the gas line to the range top. Remove the backguard from its box. 2. Fasten the provided screws through the... backguard will make contact. Installation 17 INSTALLING THE 30", 36" & 48" RANGE OPTIONAL BACKGUARDS Your Electrolux IconTM range was removed. 5. Figure 11 Figure 12 Backguard Installation (36" range shown) Backguard Installation (48" range shown) NOTE For 24" Backguards, fasten the provided screws through the rear...
Installation Instructions
Page 21
... wire securely clamped to an external grounding connector screw. WARNING • Do not ground the appliance to a gas supply pipe or hot water pipe. • Do not turn on power to the appliance until the range is permanently grounded. • A grounded cold water pipe must have metal continuity to electrical ground and...
... wire securely clamped to an external grounding connector screw. WARNING • Do not ground the appliance to a gas supply pipe or hot water pipe. • Do not turn on power to the appliance until the range is permanently grounded. • A grounded cold water pipe must have metal continuity to electrical ground and...
Installation Instructions
Page 22
... addition to the pressure regulator provided with the appliance. 22 Installation MAKING THE GAS CONNECTION Before sliding the range into the cabinet, connect a flexible gas connector to the gas shut-off during installation. WARNING • Do not apply excessive pressure when tightening gas connections and fittings. • Do not use a flame to check for natural...
... addition to the pressure regulator provided with the appliance. 22 Installation MAKING THE GAS CONNECTION Before sliding the range into the cabinet, connect a flexible gas connector to the gas shut-off during installation. WARNING • Do not apply excessive pressure when tightening gas connections and fittings. • Do not use a flame to check for natural...
Installation Instructions
Page 24
... contact an authorized service company. Do not attempt to adjust the flame height progressively. Electrolux is not responsible for at least 2 minutes to allow any pressure testing at which ... wait for service required to ensure that will stop the heating process. For model E48DF76EPS, repeat this ignition test.) The control knob can then be steady and quiet. ...that all cooktop control valves are supplied to the range. • Check the electrical connections and gas supply to correct a faulty installation. WARNING • The range and shut-off valve must be isolated from "...
... contact an authorized service company. Do not attempt to adjust the flame height progressively. Electrolux is not responsible for at least 2 minutes to allow any pressure testing at which ... wait for service required to ensure that will stop the heating process. For model E48DF76EPS, repeat this ignition test.) The control knob can then be steady and quiet. ...that all cooktop control valves are supplied to the range. • Check the electrical connections and gas supply to correct a faulty installation. WARNING • The range and shut-off valve must be isolated from "...
Installation Instructions
Page 25
... been performed. See page 12 for use and for instructions on how to convert this appliance to nature gas from LPG. The range will not operate properly unless the correct sized orifices and air shutters are installed for each burner and valve...service technician should convert or service this appliance. Part No. 65558 Rev. 1-4 Professional series Liquid Petroleum Gas (LPG) Conversion Kit Instructions Freestanding Range Models: E30DF74EPS, E36DF76EPS, E48DF76EPS Model E30DF74EPS shown WARNING: This conversion kit shall be sure to keep the original factory installed orifices for ...
... been performed. See page 12 for use and for instructions on how to convert this appliance to nature gas from LPG. The range will not operate properly unless the correct sized orifices and air shutters are installed for each burner and valve...service technician should convert or service this appliance. Part No. 65558 Rev. 1-4 Professional series Liquid Petroleum Gas (LPG) Conversion Kit Instructions Freestanding Range Models: E30DF74EPS, E36DF76EPS, E48DF76EPS Model E30DF74EPS shown WARNING: This conversion kit shall be sure to keep the original factory installed orifices for ...
Installation Instructions
Page 28
... & E48DF76EPS Access panel for E30DF74EPS Spool: Direction for LPG operation. 4-4 Replace the cap. The large end of the spool must insert into the regulator first for natural gas Figure 4-1 Regulator Conversion Page 4 Back of range STEP 3 Prepare Range for Conversion 3-1 Move the range out from...Ring Burner Head Figure 3-1 Grate, Burner Cap and Burner Ring Removal STEP 4 Convert Regulator to a natural gas supply line, close the gas supply valve. 3-3 Disconnect the range power connector from the electrical outlet. 3-4 Remove the grates from the cooktop. 3-5 Remove all of the ...
... & E48DF76EPS Access panel for E30DF74EPS Spool: Direction for LPG operation. 4-4 Replace the cap. The large end of the spool must insert into the regulator first for natural gas Figure 4-1 Regulator Conversion Page 4 Back of range STEP 3 Prepare Range for Conversion 3-1 Move the range out from...Ring Burner Head Figure 3-1 Grate, Burner Cap and Burner Ring Removal STEP 4 Convert Regulator to a natural gas supply line, close the gas supply valve. 3-3 Disconnect the range power connector from the electrical outlet. 3-4 Remove the grates from the cooktop. 3-5 Remove all of the ...
Installation Instructions
Page 32
... with 3/8" surgical tubing. 8-3 Verify that the compression nut is tightened into the back of each shutter connector. Connect the range to the LPG supply line. 8-8 Turn off position. 8-2 With electrical power to the range disconnected, 8-6 Connect the U-tube manometer to the left rear column (WC) and below ½ PSI. Turn on the... supply valve. Page 8 STEP 8 Perform Pressure Tests 8-1 Connect the U-tube manometer to the LPG supply line. 8-5 Make sure all knobs on the front of the range are in the off the burner and the...
... with 3/8" surgical tubing. 8-3 Verify that the compression nut is tightened into the back of each shutter connector. Connect the range to the LPG supply line. 8-8 Turn off position. 8-2 With electrical power to the range disconnected, 8-6 Connect the U-tube manometer to the left rear column (WC) and below ½ PSI. Turn on the... supply valve. Page 8 STEP 8 Perform Pressure Tests 8-1 Connect the U-tube manometer to the LPG supply line. 8-5 Make sure all knobs on the front of the range are in the off the burner and the...
Installation Instructions
Page 34
...the problem, contact the factory. Be sure the igniter wire is connected to each burner head. 10-5 Connect the range to the range disconnected, open the LPG supply valve. 10-3 Using a gas leak detector or bubble forming leak detection fluid, check the following for leaks: • LPG... gas supply connection • All manifold connections • All valve connections • Bypass orifices 10-4 Re-assemble the burner heads, ...
...the problem, contact the factory. Be sure the igniter wire is connected to each burner head. 10-5 Connect the range to the range disconnected, open the LPG supply valve. 10-3 Using a gas leak detector or bubble forming leak detection fluid, check the following for leaks: • LPG... gas supply connection • All manifold connections • All valve connections • Bypass orifices 10-4 Re-assemble the burner heads, ...
Installation Instructions
Page 36
... HN A-0053-E 81 196 HN A-0053-E Model E48DF76EPS (48-Inch) Air Shutter Gap .38/9.6 .35/8.8 .30/7.7 .39/9.9 .38/9.7 .37/9.5 The Electrolux Group USA • 250 Bobby Jones Expressway • Augusta, GA 30907 1-877-4electrolux (1-877-453-3287) •... www.electroluxusa.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 1-800-688-4606 • www.electroluxca.com Page 12 Conversion Back to Natural Gas If it is necessary to return the range...
... HN A-0053-E 81 196 HN A-0053-E Model E48DF76EPS (48-Inch) Air Shutter Gap .38/9.6 .35/8.8 .30/7.7 .39/9.9 .38/9.7 .37/9.5 The Electrolux Group USA • 250 Bobby Jones Expressway • Augusta, GA 30907 1-877-4electrolux (1-877-453-3287) •... www.electroluxusa.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 1-800-688-4606 • www.electroluxca.com Page 12 Conversion Back to Natural Gas If it is necessary to return the range...