Instruction Manual
Page 1
If you have questions or comments, contact us. 1-888-431-6871 • dewalt.com INSTRUCTION MANUAL Generator DXGNR 5700 DXGNR 7000 WARNING To reduce the risk of injury, read and follow these instructions before operating product.
If you have questions or comments, contact us. 1-888-431-6871 • dewalt.com INSTRUCTION MANUAL Generator DXGNR 5700 DXGNR 7000 WARNING To reduce the risk of injury, read and follow these instructions before operating product.
Instruction Manual
Page 3
... ...4 Assembly ...5 Unpacking ...5 Install Accessory Kits ...5 Battery Replacement/Connection ...6 Emissions Information ...6 Operation ...7 Know the Generator ...7 Connection Plugs ...8 How to Use the Generator ...9 Know Generator Limits ...10 Wattage Reference Guide ...10 Before Starting Generator ...10 Starting Pull Start Engines ...11 Starting Electric Start Engines ...12 Manual Start ...13... Generator Shut Down ...13 Low Oil Level Shutdown System ...13 Charging the Battery (electric start units only...
... ...4 Assembly ...5 Unpacking ...5 Install Accessory Kits ...5 Battery Replacement/Connection ...6 Emissions Information ...6 Operation ...7 Know the Generator ...7 Connection Plugs ...8 How to Use the Generator ...9 Know Generator Limits ...10 Wattage Reference Guide ...10 Before Starting Generator ...10 Starting Pull Start Engines ...11 Starting Electric Start Engines ...12 Manual Start ...13... Generator Shut Down ...13 Low Oil Level Shutdown System ...13 Charging the Battery (electric start units only...
Instruction Manual
Page 5
...from our product dealers, or may also be legally required under other similar items, then an approved spark arrester should be ordered from DEWALT Industrial Tool Co., 701 East Joppa Road, Baltimore, MD 21286. 1-888-431-6871. EXPOSURE TO CARBON MONOXIDE CAN CAUSE CARBON ...respective engine manufacturers administer warranties for you recognize information important to cause cancer, birth defects, or other reproductive harm. DAMAGE TO THE GENERATOR, BODILY INJURY, OR DEATH COULD RESULT FROM ELEC- This is legally required in death or serious injury. NEVER use the symbols ...
...from our product dealers, or may also be legally required under other similar items, then an approved spark arrester should be ordered from DEWALT Industrial Tool Co., 701 East Joppa Road, Baltimore, MD 21286. 1-888-431-6871. EXPOSURE TO CARBON MONOXIDE CAN CAUSE CARBON ...respective engine manufacturers administer warranties for you recognize information important to cause cancer, birth defects, or other reproductive harm. DAMAGE TO THE GENERATOR, BODILY INJURY, OR DEATH COULD RESULT FROM ELEC- This is legally required in death or serious injury. NEVER use the symbols ...
Instruction Manual
Page 6
.... WARNING REFER TO LOCAL AND NATIONAL ELECTRICAL CODES TO DETER- WHERE APPLICATIONS REQUIRE EXTERNAL GROUNDING, A CONNECTION MUST BE MADE FROM THE GENERATOR TO A SOLID EARTH GROUND. FREE COPPER CABLE, NO SMALLER THAN 6 AWG, SHALL BE USED FOR THE CONDUCTOR. 2 Owner's Manual...Power. National Electrical Code. 2. ELECTROCUTION OR SHOCK COULD RESULT. ERATOR AND POTENTIALLY LEAD TO FIRES. WARNING NEVER REFILL A HOT GENERATOR WITH FUEL. WARNING INSPECT THE SPARK ARRESTOR PERIODICALLY. MINE GROUNDING REQUIREMENTS AS THIS CAN VARY PER APPLICATION. TO AVOID BACKFEEDING INTO UTILITY...
.... WARNING REFER TO LOCAL AND NATIONAL ELECTRICAL CODES TO DETER- WHERE APPLICATIONS REQUIRE EXTERNAL GROUNDING, A CONNECTION MUST BE MADE FROM THE GENERATOR TO A SOLID EARTH GROUND. FREE COPPER CABLE, NO SMALLER THAN 6 AWG, SHALL BE USED FOR THE CONDUCTOR. 2 Owner's Manual...Power. National Electrical Code. 2. ELECTROCUTION OR SHOCK COULD RESULT. ERATOR AND POTENTIALLY LEAD TO FIRES. WARNING NEVER REFILL A HOT GENERATOR WITH FUEL. WARNING INSPECT THE SPARK ARRESTOR PERIODICALLY. MINE GROUNDING REQUIREMENTS AS THIS CAN VARY PER APPLICATION. TO AVOID BACKFEEDING INTO UTILITY...
Instruction Manual
Page 7
...or visit our website www.dewalt.com. • 006948 - ING AROUND A BATTERY OR PERFORMING BATTERY SERVICE. ALWAYS DISCONNECT THE NEGATIVE (-) BATTERY CABLE FROM THE BATTERY BEFORE PERFORMING BATTERY SERVICE OR BEFORE PERFORMING ANY ELECTRICAL SERVICE ON THE GENERATOR OR ENGINE. LEAKY EXHAUST...THE CHANCE OF PERSONAL INJURY DUE TO ROTATIONAL STRESSES ON THE ROTATING MEMBERS. THE SLIGHT- NOTICE: Make sure the generator is running or immedi- Accessories Recommended accessories for your local dealer or authorized service center. BATTERY SAFETY WARNING STORAGE ...
...or visit our website www.dewalt.com. • 006948 - ING AROUND A BATTERY OR PERFORMING BATTERY SERVICE. ALWAYS DISCONNECT THE NEGATIVE (-) BATTERY CABLE FROM THE BATTERY BEFORE PERFORMING BATTERY SERVICE OR BEFORE PERFORMING ANY ELECTRICAL SERVICE ON THE GENERATOR OR ENGINE. LEAKY EXHAUST...THE CHANCE OF PERSONAL INJURY DUE TO ROTATIONAL STRESSES ON THE ROTATING MEMBERS. THE SLIGHT- NOTICE: Make sure the generator is running or immedi- Accessories Recommended accessories for your local dealer or authorized service center. BATTERY SAFETY WARNING STORAGE ...
Instruction Manual
Page 8
... information as shown listed on the data label available for Portable Generator Always use identical replacement parts. Date of Purchase Place of Purchase Repairs To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment should be performed by a DEWALT factory service center, a DEWALT authorized service center or an Independent Authorized Service Dealer (IASD...
... information as shown listed on the data label available for Portable Generator Always use identical replacement parts. Date of Purchase Place of Purchase Repairs To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment should be performed by a DEWALT factory service center, a DEWALT authorized service center or an Independent Authorized Service Dealer (IASD...
Instruction Manual
Page 9
... tabs to enhance portability. DXGNR7000 1. Contents Item 5700 Qty. NOTICE: The wheels are missing or damaged, or if any parts are not intended for Portable Generator 5 Slide axle (D) through wheel, 1/2" flat washer (G), and wheel bracket on frame. 2. J H B K E M C G F N A 003604 Hardware Bag Rubber Foot (E) Cotter Pin (F) 1/2" Flat Washer (G) M8 Carriage Bolt (H) M8 Bolt... 8mm box wrenches (7000W models) Install Wheel Kit (If Equipped) The wheels are specially designed to lock in place. Table -1. Install into ½" flat washer (G). DXGNR5700 1.
... tabs to enhance portability. DXGNR7000 1. Contents Item 5700 Qty. NOTICE: The wheels are missing or damaged, or if any parts are not intended for Portable Generator 5 Slide axle (D) through wheel, 1/2" flat washer (G), and wheel bracket on frame. 2. J H B K E M C G F N A 003604 Hardware Bag Rubber Foot (E) Cotter Pin (F) 1/2" Flat Washer (G) M8 Carriage Bolt (H) M8 Bolt... 8mm box wrenches (7000W models) Install Wheel Kit (If Equipped) The wheels are specially designed to lock in place. Table -1. Install into ½" flat washer (G). DXGNR5700 1.
Instruction Manual
Page 10
... - Install hold down bracket and tighten. 4. Slide rubber boot over connection hardware. 6 Owner's Manual for Portable Generator Assembly Install Frame Foot and Rubber Bumpers 1. Disconnect negative (-) battery terminal FIRST (A). 2. Emissions Information The Environmental Protection...positive (+) battery terminal (B) FIRST (B). A battery may lose some charge when not in the handle assembly (C). 2. This generator is unable to operate on gasoline. Pulsed Air Valve - Battery Replacement/Connection NOTICE: The battery shipped with exhaust and evaporative...
... - Install hold down bracket and tighten. 4. Slide rubber boot over connection hardware. 6 Owner's Manual for Portable Generator Assembly Install Frame Foot and Rubber Bumpers 1. Disconnect negative (-) battery terminal FIRST (A). 2. Emissions Information The Environmental Protection...positive (+) battery terminal (B) FIRST (B). A battery may lose some charge when not in the handle assembly (C). 2. This generator is unable to operate on gasoline. Pulsed Air Valve - Battery Replacement/Connection NOTICE: The battery shipped with exhaust and evaporative...
Instruction Manual
Page 11
...and remaining fuel volume. Operates the engine at all components. 1. 120 Volt AC, 20 Amp GFCI Duplex Outlets - Operation Know the Generator Carefully read the Owner's Manual and Safety Rules before providing available run hours for details. 9. Use to recharge the 12 volt DC...in the Accessory Box. Supplies electrical power for tank capacity. 8. Filters intake air as Portable for a short duration before operating the generator. Ground the generator to move handle. 12. Quiets the engine. 11. Press the springloaded button to an approved earth ground here. Hour Meter - ...
...and remaining fuel volume. Operates the engine at all components. 1. 120 Volt AC, 20 Amp GFCI Duplex Outlets - Operation Know the Generator Carefully read the Owner's Manual and Safety Rules before providing available run hours for details. 9. Use to recharge the 12 volt DC...in the Accessory Box. Supplies electrical power for tank capacity. 8. Filters intake air as Portable for a short duration before operating the generator. Ground the generator to move handle. 12. Quiets the engine. 11. Press the springloaded button to an approved earth ground here. Hour Meter - ...
Instruction Manual
Page 12
... Duplex Receptacle This is in hours and tenths. Use each 100 hour interval, providing a two hour window to perform service. 8 000203 Owner's Manual for Portable Generator Keep extension cords as short as possible to prevent voltage drop and possible overheating of wires. 13 000788 8 Hour Meter (if equipped) The Hour Meter...
... Duplex Receptacle This is in hours and tenths. Use each 100 hour interval, providing a two hour window to perform service. 8 000203 Owner's Manual for Portable Generator Keep extension cords as short as possible to prevent voltage drop and possible overheating of wires. 13 000788 8 Hour Meter (if equipped) The Hour Meter...
Instruction Manual
Page 13
...must be properly maintained. Do not alter the installation or permit even partial blockage of ventilation provisions, as Portable An equipment ground connects the generator frame components to 7200 watts (7.2 kW) of power at 30 Amps. Owner's Manual for 250 Volts AC at 1-888-431-6871. ... DW7000, use in the home, in a vehicle, or in partly enclosed areas such as specified in noncompliance with any problems operating the generator, call the generator helpline at 30 Amps (or greater). or one double-pole circuit breaker, 25 Amp (DW5700) or 30 Amp (DW7000). This is ...
...must be properly maintained. Do not alter the installation or permit even partial blockage of ventilation provisions, as Portable An equipment ground connects the generator frame components to 7200 watts (7.2 kW) of power at 30 Amps. Owner's Manual for 250 Volts AC at 1-888-431-6871. ... DW7000, use in the home, in a vehicle, or in partly enclosed areas such as specified in noncompliance with any problems operating the generator, call the generator helpline at 30 Amps (or greater). or one double-pole circuit breaker, 25 Amp (DW5700) or 30 Amp (DW7000). This is ...
Instruction Manual
Page 14
...8226; Some electric motors, such as induction types, require about three times more watts of power for starting than the wattage capacity of the generator. • The rated wattage of lights can be taken from light bulbs. See data label on appliance for help in determining how many... to the expected operating temperature (also see chart). • Above 40° F, use synthetic 5W-30 Use petroleum based oil for Portable Generator This power surge lasts only a few seconds. Wattage Reference Guide Device Running Watts *Air Conditioner (12,000 Btu 1700 *Air Conditioner (24,000...
...8226; Some electric motors, such as induction types, require about three times more watts of power for starting than the wattage capacity of the generator. • The rated wattage of lights can be taken from light bulbs. See data label on appliance for help in determining how many... to the expected operating temperature (also see chart). • Above 40° F, use synthetic 5W-30 Use petroleum based oil for Portable Generator This power surge lasts only a few seconds. Wattage Reference Guide Device Running Watts *Air Conditioner (12,000 Btu 1700 *Air Conditioner (24,000...
Instruction Manual
Page 15
...units have more than one Fuel Never fill fuel tank indoors. Do not spill gasoline on a level surface. 2. Always leave room for Portable Generator 11 Never use a gas oil mix. • DO NOT modify engine to run on alternate fuels. Failure to storage. 1. Open the...before storage of an engine while in a well ventilated area. 3. Disconnect electrical loads prior to start the engine before starting engine. 2. Place generator on level ground in storage. Owner's Manual for fuel expansion. Operation CAUTION Any attempt to crank or start - non-ethanol premium fuel is...
...units have more than one Fuel Never fill fuel tank indoors. Do not spill gasoline on a level surface. 2. Always leave room for Portable Generator 11 Never use a gas oil mix. • DO NOT modify engine to run on alternate fuels. Failure to storage. 1. Open the...before storage of an engine while in a well ventilated area. 3. Disconnect electrical loads prior to start the engine before starting engine. 2. Place generator on level ground in storage. Owner's Manual for fuel expansion. Operation CAUTION Any attempt to crank or start - non-ethanol premium fuel is...
Instruction Manual
Page 16
...circuit breakers. These outlets are protected against overload with push-to Full Choke position (left). 000208 C 4. Read "Don't Overload the Generator" carefully. Disconnect electrical loads prior to Full Choke. 5. Move engine choke knob outward to start only). Press and hold Start/Run/Stop...into Run position. If amperage rating of any circuit breaker is exceeded, that receptacle is felt. Owner's Manual for Portable Generator If engine falters, move choke knob to that breaker opens and electrical output to 1/2-choke position until engine runs smoothly, ...
...circuit breakers. These outlets are protected against overload with push-to Full Choke position (left). 000208 C 4. Read "Don't Overload the Generator" carefully. Disconnect electrical loads prior to Full Choke. 5. Move engine choke knob outward to start only). Press and hold Start/Run/Stop...into Run position. If amperage rating of any circuit breaker is exceeded, that receptacle is felt. Owner's Manual for Portable Generator If engine falters, move choke knob to that breaker opens and electrical output to 1/2-choke position until engine runs smoothly, ...
Instruction Manual
Page 17
...teries. WARNING Risk of battery charger into Battery Charger Input jack, located on the control panel. Failure to charge the battery while the generator is lost. Plug charger into 120 Volt AC wall outlet. 2. Firmly grasp the recoil handle and pull slowly until the oil has ... if the battery is felt. 2. To start units only) WARNING Explosion. If amperage rating of fuel. NOTICE: The battery shipped with the generator has been fully charged. "!44%29 #(!2'%2 ).054 000423 Owner's Manual for several minutes to be in the accessory box. ing or stopping unit...
...teries. WARNING Risk of battery charger into Battery Charger Input jack, located on the control panel. Failure to charge the battery while the generator is lost. Plug charger into 120 Volt AC wall outlet. 2. Firmly grasp the recoil handle and pull slowly until the oil has ... if the battery is felt. 2. To start units only) WARNING Explosion. If amperage rating of fuel. NOTICE: The battery shipped with the generator has been fully charged. "!44%29 #(!2'%2 ).054 000423 Owner's Manual for several minutes to be in the accessory box. ing or stopping unit...
Instruction Manual
Page 18
Operation This page intentionally left blank. 14 Owner's Manual for Portable Generator
Operation This page intentionally left blank. 14 Owner's Manual for Portable Generator
Instruction Manual
Page 19
..., oil, etc. NOTICE: Call 1-888-431-6871 with questions about 3.5% for each 1,000 feet above 25 deg. Generator warranty does not cover items subjected to use . Maintenance Schedule Follow maintenance schedule intervals, whichever occurs first according to operator abuse... or negligence. NOTICE: All required service and adjustments should be a decrease in the following chart. Product Specifications Generator Specifications Rated Power 5.7 / 7.0 kW** Surge Power 7.125 / 8.75 kW Rated AC Voltage 120/240 Rated AC Load (5.7 / 7.0) ...
..., oil, etc. NOTICE: Call 1-888-431-6871 with questions about 3.5% for each 1,000 feet above 25 deg. Generator warranty does not cover items subjected to use . Maintenance Schedule Follow maintenance schedule intervals, whichever occurs first according to operator abuse... or negligence. NOTICE: All required service and adjustments should be a decrease in the following chart. Product Specifications Generator Specifications Rated Power 5.7 / 7.0 kW** Surge Power 7.125 / 8.75 kW Rated AC Voltage 120/240 Rated AC Load (5.7 / 7.0) ...
Instruction Manual
Page 20
...on unit. NOTICE: Don't pollute. Properly dispose of windings. ulations. 16 Owner's Manual for engine break-in (30 hours) before using generator under extreme, dirty, dusty conditions, or in death or serious injury. Fail- Add recommended engine oil as shown. 000116 5. NOTICE: oil... so could result in extremely hot weather, change oil more than one Change Engine Oil WARNING Accidental start-up. Place generator on generator. Disconnect spark plug wires when working on unit. Verify oil level is only necessary to use synthetic 5W-30 Use ...
...on unit. NOTICE: Don't pollute. Properly dispose of windings. ulations. 16 Owner's Manual for engine break-in (30 hours) before using generator under extreme, dirty, dusty conditions, or in death or serious injury. Fail- Add recommended engine oil as shown. 000116 5. NOTICE: oil... so could result in extremely hot weather, change oil more than one Change Engine Oil WARNING Accidental start-up. Place generator on generator. Disconnect spark plug wires when working on unit. Verify oil level is only necessary to use synthetic 5W-30 Use ...
Instruction Manual
Page 21
... in the 12V charger included in (0.70 - 0.80 mm). 000211 NOTICE: Replace spark plug if electrodes are not available, take generator to the nearest service center to have valve clearance adjusted. Inspect electrode gap with wire feeler gauge and reset spark plug gap to ... rubber boot over connection hardware. 5. Clean air filter cover before re-installing it. IMPORTANT: RUNNING THE GENERATOR DOES NOT CHARGE BATTERY. tions. 4. A battery may be damaged if run with the generator has been fully charged. B 000809 A Service Spark Plug To service spark plug: 1. Remove and inspect...
... in the 12V charger included in (0.70 - 0.80 mm). 000211 NOTICE: Replace spark plug if electrodes are not available, take generator to the nearest service center to have valve clearance adjusted. Inspect electrode gap with wire feeler gauge and reset spark plug gap to ... rubber boot over connection hardware. 5. Clean air filter cover before re-installing it. IMPORTANT: RUNNING THE GENERATOR DOES NOT CHARGE BATTERY. tions. 4. A battery may be damaged if run with the generator has been fully charged. B 000809 A Service Spark Plug To service spark plug: 1. Remove and inspect...
Instruction Manual
Page 22
... clean engine oil or spray a suit- wise damaged. Hot surfaces could result in a clean and dry area. • Always store generator and fuel away from spark plug hole when cranking engine. Allow unit to cool to 24 months. WARNING Vision Loss. Change Oil Change ...season to keep fuel fresh. 1. Secure with fuel stabilizer, it stops from combustibles during use fuel stabilizer. Prepare Fuel System/Engine for Portable Generator NOTICE: If fuel has not been treated with clamp and screw. If screen is present. Replace spark arrestor cone (C) and screen (B). ...
... clean engine oil or spray a suit- wise damaged. Hot surfaces could result in a clean and dry area. • Always store generator and fuel away from spark plug hole when cranking engine. Allow unit to cool to 24 months. WARNING Vision Loss. Change Oil Change ...season to keep fuel fresh. 1. Secure with fuel stabilizer, it stops from combustibles during use fuel stabilizer. Prepare Fuel System/Engine for Portable Generator NOTICE: If fuel has not been treated with clamp and screw. If screen is present. Replace spark arrestor cone (C) and screen (B). ...