Instruction Manual
Page 5
COUPLER G. PUMP OIL DRAIN I H TANK DRAIN VALVE SAFETY RELIEF VALVE G I . TANK PRESSURE REGULATOR GAUGE REGULATED A PRESSURE GAUGE B PRESSURE SWITCH C QUICK CONNECT COUPLERS SAFETY RELIEF VALVE PUMP OIL FILL DIPSTICK PUMP OIL DRAIN ON / OFF LEVER MOTOR RESET SWITCH D E F A. PRESSURE SWITCH D. ON/OFF LEVER C. DRAIN VALVE K. REGULATOR F. REGULATED PRESSURE GAUGE E. MOTOR RESET SWITCH J. PUMP OIL FILL DIPSTICK H. TANK PRESSURE GAUGE B.
COUPLER G. PUMP OIL DRAIN I H TANK DRAIN VALVE SAFETY RELIEF VALVE G I . TANK PRESSURE REGULATOR GAUGE REGULATED A PRESSURE GAUGE B PRESSURE SWITCH C QUICK CONNECT COUPLERS SAFETY RELIEF VALVE PUMP OIL FILL DIPSTICK PUMP OIL DRAIN ON / OFF LEVER MOTOR RESET SWITCH D E F A. PRESSURE SWITCH D. ON/OFF LEVER C. DRAIN VALVE K. REGULATOR F. REGULATED PRESSURE GAUGE E. MOTOR RESET SWITCH J. PUMP OIL FILL DIPSTICK H. TANK PRESSURE GAUGE B.
Instruction Manual
Page 6
MODEL WEIGHT HEIGHT WIDTH LENGTH MOTOR PUMP OIL CFM/PSI D55150 57 lbs. 16.75 in. 18.0 in. 15.0 in. 1 HP,120 V. 12 A. 60 Hz. 1725 RPM 4 oz. 4.0@40 3.4@60 2.8@90 2.6@100 D55151 53 lbs. 16.75 in. 18.0 in. 15.0 in. 2 HP, 120 V. 14 A. 60 Hz. 3450 RPM 6 oz. 4.8@40 4.4@60 3.8@90...
MODEL WEIGHT HEIGHT WIDTH LENGTH MOTOR PUMP OIL CFM/PSI D55150 57 lbs. 16.75 in. 18.0 in. 15.0 in. 1 HP,120 V. 12 A. 60 Hz. 1725 RPM 4 oz. 4.0@40 3.4@60 2.8@90 2.6@100 D55151 53 lbs. 16.75 in. 18.0 in. 15.0 in. 2 HP, 120 V. 14 A. 60 Hz. 3450 RPM 6 oz. 4.8@40 4.4@60 3.8@90...
Instruction Manual
Page 8
... illustrated in an open area at least 20 feet upwind from any of the electric cord or plug is intended for electrical contacts within the motor be performed by a qualified electrician. If repair or replacement of the compressor ventilation openings will not fit the outlet, have 3-prong grounding plugs and 3-pole...
... illustrated in an open area at least 20 feet upwind from any of the electric cord or plug is intended for electrical contacts within the motor be performed by a qualified electrician. If repair or replacement of the compressor ventilation openings will not fit the outlet, have 3-prong grounding plugs and 3-pole...
Instruction Manual
Page 9
...Length of Cord in Feet 25' 50' 100' 12 amp, 115V 14 Ga. 12 Ga. 10 Ga. 2 Hp Motor Rating 15 amp, 115V Length of the motor. Use only OSHA approved air blow guns. RISK FROM MOVING PARTS The compressor cycles automatically when the pressure switch is not... spraying. Do not remove the protective covers from your hair, clothing, and gloves away from power source before performing maintenance or attaching tools and accessories. DEWALT does not recommend the use with specific a p p l i c a t i o n . If use of extension cords. Loose clothes, jewelry, or long hair can be ...
...Length of Cord in Feet 25' 50' 100' 12 amp, 115V 14 Ga. 12 Ga. 10 Ga. 2 Hp Motor Rating 15 amp, 115V Length of the motor. Use only OSHA approved air blow guns. RISK FROM MOVING PARTS The compressor cycles automatically when the pressure switch is not... spraying. Do not remove the protective covers from your hair, clothing, and gloves away from power source before performing maintenance or attaching tools and accessories. DEWALT does not recommend the use with specific a p p l i c a t i o n . If use of extension cords. Loose clothes, jewelry, or long hair can be ...
Instruction Manual
Page 10
...free operation.The manufacturer reserves the right to the delivering freight carrier immediately. For ease of starting, this manual, you will allow the motor to automatically release compressed air from charging air when the air tank pressure reaches B A the factory set cut -out pressure limit. ... the pressure switch stops the compressor from the air compressor pump head and its discharge line when the air compressor reaches the cut- DEWALT Air Compressor Features PRESSURE SWITCH This switch (A) is used to start when the air tank pressure is located on the side of the ...
...free operation.The manufacturer reserves the right to the delivering freight carrier immediately. For ease of starting, this manual, you will allow the motor to automatically release compressed air from charging air when the air tank pressure reaches B A the factory set cut -out pressure limit. ... the pressure switch stops the compressor from the air compressor pump head and its discharge line when the air compressor reaches the cut- DEWALT Air Compressor Features PRESSURE SWITCH This switch (A) is used to start when the air tank pressure is located on the side of the ...
Instruction Manual
Page 11
...If oil is controlled by the manufacturer and must be checked on page 4). 1. Ensure that the tank is off power, thus preventing the motor from being damaged. Drain the tanks if necessary. 3. Grasp the wire ring on a flat horizontal surface. 3. pressure switch contacts and ...the system when the compressed air reaches a predetermined level. Do not touch (see Hot Surfaces on dipstick. 5. Wipe oil off . 2. DEWALT synthetic oil MAX MIN CHECKING SAFETY RELIEF VALVE OPERATION WARNING: Aftercooler, pump head, and surrounding parts are very hot. Remove dipstick (H) from the...
...If oil is controlled by the manufacturer and must be checked on page 4). 1. Ensure that the tank is off power, thus preventing the motor from being damaged. Drain the tanks if necessary. 3. Grasp the wire ring on a flat horizontal surface. 3. pressure switch contacts and ...the system when the compressed air reaches a predetermined level. Do not touch (see Hot Surfaces on dipstick. 5. Wipe oil off . 2. DEWALT synthetic oil MAX MIN CHECKING SAFETY RELIEF VALVE OPERATION WARNING: Aftercooler, pump head, and surrounding parts are very hot. Remove dipstick (H) from the...
Instruction Manual
Page 18
...DEWALT Synthetic lubricant. Run unit for proper fuse. Check tubing and connections. Clean or replace as required.. Install more effective filtration or relocate the compressor. Turn the compressor off, wait until a click is in crankcase. Check the chart on motor) firmly until motor... cord into grounded outlet. Move switch to warmer environment. Lubricant level too low. Install new rings. Deglaze cylinder with DEWALT Synthetic lubricant. Worn connecting rod, piston pin, or crankpin bearings. Clean piston. Replace seal or crankshaft assembly. Carbon ...
...DEWALT Synthetic lubricant. Run unit for proper fuse. Check tubing and connections. Clean or replace as required.. Install more effective filtration or relocate the compressor. Turn the compressor off, wait until a click is in crankcase. Check the chart on motor) firmly until motor... cord into grounded outlet. Move switch to warmer environment. Lubricant level too low. Install new rings. Deglaze cylinder with DEWALT Synthetic lubricant. Worn connecting rod, piston pin, or crankpin bearings. Clean piston. Replace seal or crankshaft assembly. Carbon ...
Instruction Manual
Page 19
...motor when air compressor reaches "cut -in the "Auto" position. Defective pressure switch. Do not attempt to proper setting or replace. Adjust pressure regulator knob to repair air tank. Remove pump head and inspect valve plate and reed valve. Drain oil. Clean dipstick vent. Drain oil. If problem persists, contact DEWALT...to condensation. 40 Condensation in air tank caused by pulling on pressure switch has not unloaded pump head pressure. 24 Defective motor, motor capacitor, or pressure switch. 25 Pressure switch does not shut off , unplug the air compressor. If it still leaks, replace...
...motor when air compressor reaches "cut -in the "Auto" position. Defective pressure switch. Do not attempt to proper setting or replace. Adjust pressure regulator knob to repair air tank. Remove pump head and inspect valve plate and reed valve. Drain oil. Clean dipstick vent. Drain oil. If problem persists, contact DEWALT...to condensation. 40 Condensation in air tank caused by pulling on pressure switch has not unloaded pump head pressure. 24 Defective motor, motor capacitor, or pressure switch. 25 Pressure switch does not shut off , unplug the air compressor. If it still leaks, replace...