EMC SmartFabric OS10 Switch Configuration Guide for VxRail 4.7
Page 20
... using the serial console port as follows: OS10# delete startup-configuration Proceed to delete startup-configuration [confirm yes/no(default)]:y OS10# reload System configuration has been modified. 6.3 Factory default configuration The configuration commands in the sections that follow begin with S5248F-ON switches at ...an SSH or Telnet session, but the reload command immediately ends the remote access session to their factory default settings. Dell EMC PowerSwitches running SmartFabric OS10 can also be reset to the switch. The switch reboots to a complex password during the first ...
... using the serial console port as follows: OS10# delete startup-configuration Proceed to delete startup-configuration [confirm yes/no(default)]:y OS10# reload System configuration has been modified. 6.3 Factory default configuration The configuration commands in the sections that follow begin with S5248F-ON switches at ...an SSH or Telnet session, but the reload command immediately ends the remote access session to their factory default settings. Dell EMC PowerSwitches running SmartFabric OS10 can also be reset to the switch. The switch reboots to a complex password during the first ...
EMC SmartFabric OS10 Switch Configuration Guide for VxRail 4.7
Page 42
...may be able to communicate with a web browser for redundancy using the iDRAC virtual console. It is 192.168.10.200/24. Workstation OOB Mgmt PowerEdge Server iDRAC PowerEdge server as a jump box S5248F-ON 192.168.10.1 and 172.16.11.50 VxRail Node VxRail Node VxRail ...set to 10GbE to allow connectivity to its new address on the laptop computer/jump box in this example are configured on S5248F-ON port-group configuration. 42 Dell EMC SmartFabric OS10 Switch Configuration Guide for deployment If a PowerEdge server is required. The new VxRail Manager address used as ...
...may be able to communicate with a web browser for redundancy using the iDRAC virtual console. It is 192.168.10.200/24. Workstation OOB Mgmt PowerEdge Server iDRAC PowerEdge server as a jump box S5248F-ON 192.168.10.1 and 172.16.11.50 VxRail Node VxRail Node VxRail ...set to 10GbE to allow connectivity to its new address on the laptop computer/jump box in this example are configured on S5248F-ON port-group configuration. 42 Dell EMC SmartFabric OS10 Switch Configuration Guide for deployment If a PowerEdge server is required. The new VxRail Manager address used as ...
EMC Solutions for Microsoft Azure Stack HCI Networking Guide
Page 14
...server. 4. First NIC port in the list to launch the Main Configuration Page for Microsoft Azure Stack HCI Networking Guide In the virtual console, from their factory default settings. 1. On the System Setup Main Menu page, select Device Settings. 5 5.1 Configure network adapters Note: ...Exact iDRAC steps in a web browser and launch the virtual console. 2. On the Device Settings page, click the first network adapter port in the device list 14 Dell EMC Solutions for the port. Device Settings menu item 5. See the PowerEdge server documentation...
...server. 4. First NIC port in the list to launch the Main Configuration Page for Microsoft Azure Stack HCI Networking Guide In the virtual console, from their factory default settings. 1. On the System Setup Main Menu page, select Device Settings. 5 5.1 Configure network adapters Note: ...Exact iDRAC steps in a web browser and launch the virtual console. 2. On the Device Settings page, click the first network adapter port in the device list 14 Dell EMC Solutions for the port. Device Settings menu item 5. See the PowerEdge server documentation...
EMC Solutions for Microsoft Azure Stack HCI Networking Guide
Page 15
... to load the default settings. If the system is already in a web browser and launch the virtual console. 2. In the virtual console, from the prior section, skip to take effect. 8. QL41262 adapter Port 1 menu item 15 Dell EMC Solutions for this deployment. Note: Intel X710/i350 and Mellanox ConnectX-4 Lx adapters use their...
... to load the default settings. If the system is already in a web browser and launch the virtual console. 2. In the virtual console, from the prior section, skip to take effect. 8. QL41262 adapter Port 1 menu item 15 Dell EMC Solutions for this deployment. Note: Intel X710/i350 and Mellanox ConnectX-4 Lx adapters use their...
EMC Solutions for Microsoft Azure Stack HCI Networking Guide
Page 19
...adapters are known to be at their factory default settings. Reboot the server. 4. On the Main Configuration Page, click NIC Configuration. NIC Configuration highlighted 19 Dell EMC Solutions for this section are no RDMA or DCB settings in System Setup from the Next Boot menu, select BIOS Setup. 3. If the system...iDRAC in this adapter. On the System Setup Main Menu page, select Device Settings. 5. Note: The settings shown in a web browser and launch the virtual console. 2. In the virtual console, from Section 5.1, skip to launch the Main Configuration Page for the port.
...adapters are known to be at their factory default settings. Reboot the server. 4. On the Main Configuration Page, click NIC Configuration. NIC Configuration highlighted 19 Dell EMC Solutions for this section are no RDMA or DCB settings in System Setup from the Next Boot menu, select BIOS Setup. 3. If the system...iDRAC in this adapter. On the System Setup Main Menu page, select Device Settings. 5. Note: The settings shown in a web browser and launch the virtual console. 2. In the virtual console, from Section 5.1, skip to launch the Main Configuration Page for the port.
VxFlex Network Deployment Guide using EMC Networking 25GbE switches and OS10EE
Page 23
...create the distributed switches, VMkernels, and setting NIC teaming policies are not covered in this document. See How to migrate service console / VMkernel port from the default standard switch to VMware vSphere Distributed Switch. This creates a traditional storage topology where each ...group configuration settings Parameter Settings Failover Detection Link status only Notify switches Enabled Failback Yes 23 VxFlex Network Deployment Guide using Dell EMC Networking 25GbE switches and OS10EE VxFlex data networks (Data1 and Data2) use Route based on Originating Virtual Port. ...
...create the distributed switches, VMkernels, and setting NIC teaming policies are not covered in this document. See How to migrate service console / VMkernel port from the default standard switch to VMware vSphere Distributed Switch. This creates a traditional storage topology where each ...group configuration settings Parameter Settings Failover Detection Link status only Notify switches Enabled Failback Yes 23 VxFlex Network Deployment Guide using Dell EMC Networking 25GbE switches and OS10EE VxFlex data networks (Data1 and Data2) use Route based on Originating Virtual Port. ...
EMC Networking OS10EE FCoE Deployment with FSB
Page 35
...Page, click Default and then Yes to the first server's iDRAC in a web browser and log in a web browser and launch the virtual console. 2. Repeat steps 5 through 9 for steps to connect to validate the network topology. WWPNs may vary depending on hardware, software and browser versions... Finish. 8. Repeat steps 1 through 8 for FC zone configuration. Select System > Network Devices. 3. Note: Exact iDRAC steps in Figure 9. 35 Dell EMC Networking OS10EE FCoE Deployment with FSB Note: In this section may be determined using the iDRAC as shown in this example, click NIC Slot...
...Page, click Default and then Yes to the first server's iDRAC in a web browser and log in a web browser and launch the virtual console. 2. Repeat steps 5 through 9 for steps to connect to validate the network topology. WWPNs may vary depending on hardware, software and browser versions... Finish. 8. Repeat steps 1 through 8 for FC zone configuration. Select System > Network Devices. 3. Note: Exact iDRAC steps in Figure 9. 35 Dell EMC Networking OS10EE FCoE Deployment with FSB Note: In this section may be determined using the iDRAC as shown in this example, click NIC Slot...
EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON S5232F-ON and S5148F-ON
Page 41
... user interface is required. Figure 18 shows a single connection from a workstation via the iDRAC virtual console. It is either plugged into a leaf switch or able to its new address on the network.... Note: Both addresses may be able to a leaf switch for clarity. 41 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for each network. By default, the initial ... data in 0. The IP addresses configured on the network adapter, one for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON Workstation OOB Mgmt PowerEdge Server iDRAC PowerEdge server as ...
... user interface is required. Figure 18 shows a single connection from a workstation via the iDRAC virtual console. It is either plugged into a leaf switch or able to its new address on the network.... Note: Both addresses may be able to a leaf switch for clarity. 41 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for each network. By default, the initial ... data in 0. The IP addresses configured on the network adapter, one for VxRail featuring S5248F-ON, S5232F-ON and S5148F-ON Workstation OOB Mgmt PowerEdge Server iDRAC PowerEdge server as ...
OpenSwitch OPX Installation Guide with Enhancement Package Release 3.1.0
Page 6
...correctly before installation: • Connect a serial cable and terminal emulator to the console serial port - Manually configure your switch or the platform-specific Installation Guide at www.dell.com/support. required serial port settings are 115200, 8 data bits, and no...new ONIE version. • Embed ONIE - ONIE installation support • Automatic (zero-touch) installation - Install OpenSwitch OPX If there is visible and accessible via the console. |*ONIE: Install OS | | ONIE: Rescue | | ONIE: Uninstall OS | | ONIE: Update ONIE | | ONIE: Embed ONIE | | ONIE: Diag...
...correctly before installation: • Connect a serial cable and terminal emulator to the console serial port - Manually configure your switch or the platform-specific Installation Guide at www.dell.com/support. required serial port settings are 115200, 8 data bits, and no...new ONIE version. • Embed ONIE - ONIE installation support • Automatic (zero-touch) installation - Install OpenSwitch OPX If there is visible and accessible via the console. |*ONIE: Install OS | | ONIE: Rescue | | ONIE: Uninstall OS | | ONIE: Update ONIE | | ONIE: Embed ONIE | | ONIE: Diag...
Open Networking Hardware Diagnostic Guide December 2021
Page 6
This tool tests for the next boot. If a test fails, each diagnostic tool offers a different result. onie-boot-mode onie-fwpkg onie-console onie-nos-install onie-discovery-start onie-self-update onie-discovery-stop onie-support onie-syseeprom onie-sysinfo onie-uninstaller Topics: • Boot processes • ...
This tool tests for the next boot. If a test fails, each diagnostic tool offers a different result. onie-boot-mode onie-fwpkg onie-console onie-nos-install onie-discovery-start onie-self-update onie-discovery-stop onie-support onie-syseeprom onie-sysinfo onie-uninstaller Topics: • Boot processes • ...
Open Networking Hardware Diagnostic Guide December 2021
Page 9
... are for reference only; ONIE expansion To view all the ONIE commands available, from . onie-boot-mode onie-fwpkg onie-console onie-nos-install onie-discovery-start onie-self-update onie-discovery-stop onie-support onie-syseeprom onie-sysinfo onie-uninstaller Topics: ...• ONIE installation • BIOS settings for any equipment that any reason other than installation, use the RJ-45 console port. If you are successfully installed again. and click twice. ONIE installation instructions 9 NOTE: After installing the networking operating software...
... are for reference only; ONIE expansion To view all the ONIE commands available, from . onie-boot-mode onie-fwpkg onie-console onie-nos-install onie-discovery-start onie-self-update onie-discovery-stop onie-support onie-syseeprom onie-sysinfo onie-uninstaller Topics: ...• ONIE installation • BIOS settings for any equipment that any reason other than installation, use the RJ-45 console port. If you are successfully installed again. and click twice. ONIE installation instructions 9 NOTE: After installing the networking operating software...
Open Networking Hardware Diagnostic Guide December 2021
Page 10
...-selected OS or enter e to make the ONIE UEFI-bootable USB. Confirm that messages display on the target. based boards. ● Check the console (UART-0/1) used on the console. ● The log messages included in this guide are specified using the _ notation. Boot the ONIE target in the operating system. Use ONIE...
...-selected OS or enter e to make the ONIE UEFI-bootable USB. Confirm that messages display on the target. based boards. ● Check the console (UART-0/1) used on the console. ● The log messages included in this guide are specified using the _ notation. Boot the ONIE target in the operating system. Use ONIE...
Open Networking Hardware Diagnostic Guide December 2021
Page 12
... ONIE Service Discovery Info: Found static url: file:///lib/onie/onie-updater [ 29.744855] random: nonblocking pool is removed. Please press Enter to activate this console. This step installs the UEFI ONIE version 3.26.1.1 on interface: eth0 ONIE: Using DHCPv4 addr: eth0: 1[ 20.053045] random: dropbearkey urandom read cache: enabled, doesn...
... ONIE Service Discovery Info: Found static url: file:///lib/onie/onie-updater [ 29.744855] random: nonblocking pool is removed. Please press Enter to activate this console. This step installs the UEFI ONIE version 3.26.1.1 on interface: eth0 ONIE: Using DHCPv4 addr: eth0: 1[ 20.053045] random: dropbearkey urandom read cache: enabled, doesn...
Open Networking Hardware Diagnostic Guide December 2021
Page 14
....xxx.x ONIE: Starting ONIE Service Discovery Info: Fetching https://xx.xx.xxx.x/onie-installer-x86_64-dell__c2538-r0 ... Starting: telnetd... Starting: discover... up to activate this console. Info: Fetching https://xx.xx.xxx.x/onie-installer-dell__c2538 ... Info: Fetching https://xx.xx.xxx.x/onie-installer-x86_64-dell__c2538 ... 11. Stop ONIE Discovery mode. Verify...
....xxx.x ONIE: Starting ONIE Service Discovery Info: Fetching https://xx.xx.xxx.x/onie-installer-x86_64-dell__c2538-r0 ... Starting: telnetd... Starting: discover... up to activate this console. Info: Fetching https://xx.xx.xxx.x/onie-installer-dell__c2538 ... Info: Fetching https://xx.xx.xxx.x/onie-installer-x86_64-dell__c2538 ... 11. Stop ONIE Discovery mode. Verify...
Open Networking Hardware Diagnostic Guide December 2021
Page 20
...% Erase complete. No error reported. Press ENTER to erase storage. 1. CAUTION: Restoring factory defaults erases any installed OS and requires a long time to activate the console. 3. GNU GRUB version 2.02~beta2+e4a1fe391 | ONIE: Install OS | | ONIE: Rescue | |*ONIE: Uninstall OS | | ONIE: Update ONIE | | ONIE: Embed ONIE | | EDA-... which entry is going down NOW! If it is not possible to ONIE: Uninstall OS mode. machine restart 20 Dell EMC DIAG OS Restore the factory defaults on your factory defaults with the installed OS, reboot the system from the ...
...% Erase complete. No error reported. Press ENTER to erase storage. 1. CAUTION: Restoring factory defaults erases any installed OS and requires a long time to activate the console. 3. GNU GRUB version 2.02~beta2+e4a1fe391 | ONIE: Install OS | | ONIE: Rescue | |*ONIE: Uninstall OS | | ONIE: Update ONIE | | ONIE: Embed ONIE | | EDA-... which entry is going down NOW! If it is not possible to ONIE: Uninstall OS mode. machine restart 20 Dell EMC DIAG OS Restore the factory defaults on your factory defaults with the installed OS, reboot the system from the ...
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 4
... Power cable clip installation...47 Chapter 6: Fans...49 Components...49 Fan module installation...50 Fan module replacement...51 Chapter 7: Management ports...52 RJ45 console port access...52 MicroUSB-B console port access...53 USB storage mount...54 Before you install an OS...54 Check your switch...55 ONIE service discovery...56 Chapter 8: Specifications...for class A equipment...61 Korean certification of compliance...61 Safety standards and compliance agency certifications 62 Electromagnetic compatibility ...62 Product recycling and disposal...63 Chapter 9: Dell EMC support...64 4 Contents
... Power cable clip installation...47 Chapter 6: Fans...49 Components...49 Fan module installation...50 Fan module replacement...51 Chapter 7: Management ports...52 RJ45 console port access...52 MicroUSB-B console port access...53 USB storage mount...54 Before you install an OS...54 Check your switch...55 ONIE service discovery...56 Chapter 8: Specifications...for class A equipment...61 Korean certification of compliance...61 Safety standards and compliance agency certifications 62 Electromagnetic compatibility ...62 Product recycling and disposal...63 Chapter 9: Dell EMC support...64 4 Contents
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 9
Luggage tag 6. Twenty-four SFP28 ports 4. RJ45 Ethernet port 8. RJ45 console port 1. MicroUSB-B console port 2. MicroUSB-B console port 9. Stack ID 8. AC PSUs 9. Stack ID 4. RJ45 console port 10. USB Type A 7. Three 100GbE QSFP28 ports The S5212F-ON DC switch I /O-side view: 2. Stack ID 4. MicroUSB-B console port 5. LED status icons 6. RJ45 Ethernet port 1. LED status icons 1. Stack...
Luggage tag 6. Twenty-four SFP28 ports 4. RJ45 Ethernet port 8. RJ45 console port 1. MicroUSB-B console port 2. MicroUSB-B console port 9. Stack ID 8. AC PSUs 9. Stack ID 4. RJ45 console port 10. USB Type A 7. Three 100GbE QSFP28 ports The S5212F-ON DC switch I /O-side view: 2. Stack ID 4. MicroUSB-B console port 5. LED status icons 6. RJ45 Ethernet port 1. LED status icons 1. Stack...
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 10
...switches only, one USB extension cable, which is packaged separately. Management ports are located on the PSU-side of the switch. The S5232F-ON or S5248F-ON switch PSU-side view: 1. Luggage tag 7. Reset button 10. RJ45 Ethernet port 8. Fan units 2. AC PSU units The S5224F-ON ...side view: 10 S5200F-ON Series switch AC PSU2 9. Three 100GbE QSFP28 ports 6. RJ45 Ethernet port 5. MicroUSB-B console port The S5296F-ON switch PSU-side view: 2. USB Type A 7. RJ45 console port The S5212F-ON AC and DC switches have a reset button on the I /O-side below the Stack ID ...
...switches only, one USB extension cable, which is packaged separately. Management ports are located on the PSU-side of the switch. The S5232F-ON or S5248F-ON switch PSU-side view: 1. Luggage tag 7. Reset button 10. RJ45 Ethernet port 8. Fan units 2. AC PSU units The S5224F-ON ...side view: 10 S5200F-ON Series switch AC PSU2 9. Three 100GbE QSFP28 ports 6. RJ45 Ethernet port 5. MicroUSB-B console port The S5296F-ON switch PSU-side view: 2. USB Type A 7. RJ45 console port The S5212F-ON AC and DC switches have a reset button on the I /O-side below the Stack ID ...
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 11
...ON-twenty-four 25GbE SFP28 ports and four 100GbE QSFP28 ports ○ S5232F-ON-thirty-two 100GbE QSFP28 ports and two 10GbE SFP+ ports ○ S5248F-ON-forty-eight 25GbE SFP28 ports, four 100GbE QSFP28 ports, and two 200GbE QSFP-DD ports ○ S5296F-ON-ninety-six 25GbE SFP28 ports and... eight 100GbE QSFP28 ports ● One MicroUSB-B console port ● One RJ45 console port ● One USB Type A port for more file storage ● Four-core Intel Denverton central processing unit (CPU) system with 16 ...
...ON-twenty-four 25GbE SFP28 ports and four 100GbE QSFP28 ports ○ S5232F-ON-thirty-two 100GbE QSFP28 ports and two 10GbE SFP+ ports ○ S5248F-ON-forty-eight 25GbE SFP28 ports, four 100GbE QSFP28 ports, and two 200GbE QSFP-DD ports ○ S5296F-ON-ninety-six 25GbE SFP28 ports and... eight 100GbE QSFP28 ports ● One MicroUSB-B console port ● One RJ45 console port ● One USB Type A port for more file storage ● Four-core Intel Denverton central processing unit (CPU) system with 16 ...
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 52
... vary. Topics: • RJ45 console port access • MicroUSB-B console port access • USB storage mount • Before you install an OS • Check your switch • ONIE service discovery RJ45 console port access For the S5224F-ON, S5232F-ON, and S5248F-ON switches, the management ports are... on the PSU-side of the switch. Out-of -band management port (top); RJ45 console port (bottom) The S5212F-ON AC switch management...
... vary. Topics: • RJ45 console port access • MicroUSB-B console port access • USB storage mount • Before you install an OS • Check your switch • ONIE service discovery RJ45 console port access For the S5224F-ON, S5232F-ON, and S5248F-ON switches, the management ports are... on the PSU-side of the switch. Out-of -band management port (top); RJ45 console port (bottom) The S5212F-ON AC switch management...