Dell Networking Getting Started Guide
Page 4
... and other countries. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2013 Dell Inc. Trademarks used in the United States or other countries. in this text: Dell™, the Dell logo, Dell Boomi™, Dell Precision™ , OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™, EqualLogic™...
... and other countries. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2013 Dell Inc. Trademarks used in the United States or other countries. in this text: Dell™, the Dell logo, Dell Boomi™, Dell Precision™ , OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™, EqualLogic™...
Dell Networking Getting Started Guide
Page 35
Installing a Fan Module 1. CAUTION: ESD damage can occur if the components are mishandled. Release latch Installing the SFP+ and QSFP+ Optics The S5000 has 48 small form-factor pluggable plus (SFP+) optical ports and four QSFP+ optical ports. Fan module 0/Slot 1 2. Figure 22. Always wear an ESD-preventive wrist or heel ground strap when handling the S5000 and its components. 33 For a list of supported optics, refer to the S5000 data sheet: http://www.dell.com/us/ enterprise/p/force10-s-series/pd.
Installing a Fan Module 1. CAUTION: ESD damage can occur if the components are mishandled. Release latch Installing the SFP+ and QSFP+ Optics The S5000 has 48 small form-factor pluggable plus (SFP+) optical ports and four QSFP+ optical ports. Fan module 0/Slot 1 2. Figure 22. Always wear an ESD-preventive wrist or heel ground strap when handling the S5000 and its components. 33 For a list of supported optics, refer to the S5000 data sheet: http://www.dell.com/us/ enterprise/p/force10-s-series/pd.
Dell Networking Getting Started Guide
Page 36
...look directly into four 10GbE SFP+ ports using one of a terminated or unterminated fibre or connector as a stack-link to SFP+ Ports The S5000 supports splitting a single 40GbE QSFP+ port into the end of the supported breakout cables. Position the optic so it is lost in the correct ...+ ports require that prevents it may cause eye damage. 1. Enter the port number of supported optics, refer to the S5000 data sheet: http://www.dell.com/us/ enterprise/p/force10-s-series/pd. • Configure the system to interfere with optical fibres, follow all the warning labels and always wear eye...
...look directly into four 10GbE SFP+ ports using one of a terminated or unterminated fibre or connector as a stack-link to SFP+ Ports The S5000 supports splitting a single 40GbE QSFP+ port into the end of the supported breakout cables. Position the optic so it is lost in the correct ...+ ports require that prevents it may cause eye damage. 1. Enter the port number of supported optics, refer to the S5000 data sheet: http://www.dell.com/us/ enterprise/p/force10-s-series/pd. • Configure the system to interfere with optical fibres, follow all the warning labels and always wear eye...
Dell Networking Getting Started Guide
Page 202
...®, vCenter Citrix Systems, Inc IBM VMware, Inc vSphere International Business Machines Corporation 03 - 2013 Rev. A00 © Dell Inc. 2013 Dell Latitude™ ,OptiPlex™ , Dell Precision™ ,Dell Boomi™ ,Dell ™,KACE™ ,Compellent™ ,EqualLogic™ ,OpenManage™ ,PowerConnect™ ,PowerVault™ ,PowerEdge...
...®, vCenter Citrix Systems, Inc IBM VMware, Inc vSphere International Business Machines Corporation 03 - 2013 Rev. A00 © Dell Inc. 2013 Dell Latitude™ ,OptiPlex™ , Dell Precision™ ,Dell Boomi™ ,Dell ™,KACE™ ,Compellent™ ,EqualLogic™ ,OpenManage™ ,PowerConnect™ ,PowerVault™ ,PowerEdge...
Dell Networking Getting Started Guide
Page 231
22 1 0 1 .2 -QSFP+ו SFP ה S5000 48 small form-factor pluggable plus (SFP QSFP+ S5000: http://www.dell.com/us enterprise/p/force10-s-series/pd ESD ESD S5000 1 2 31
22 1 0 1 .2 -QSFP+ו SFP ה S5000 48 small form-factor pluggable plus (SFP QSFP+ S5000: http://www.dell.com/us enterprise/p/force10-s-series/pd ESD ESD S5000 1 2 31
Dell Networking Installation Guide
Page 2
... AMD® is a registered trademark of International Business Machines Corporation. 2013 Rev. in this text: Dell™, the Dell logo, Dell Boomi™, Dell Precision™ , OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™,... EqualLogic™, Compellent™, KACE™, FlexAddress™, Force10™ and Vostro™ are either potential damage ...
... AMD® is a registered trademark of International Business Machines Corporation. 2013 Rev. in this text: Dell™, the Dell logo, Dell Boomi™, Dell Precision™ , OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™,... EqualLogic™, Compellent™, KACE™, FlexAddress™, Force10™ and Vostro™ are either potential damage ...
Dell Networking Installation Guide
Page 37
... 1. Always wear an ESD-preventive wrist or heel ground strap when handling the S5000 and its components. Use the grab handle to the S5000 data sheet: http://www.dell.com/us/enterprise/p/force10-s-series/pd. Installing the SFP+ and QSFP+ Optics The S5000 has 48 small form-factor pluggable plus (SFP+) optical ports and four...
... 1. Always wear an ESD-preventive wrist or heel ground strap when handling the S5000 and its components. Use the grab handle to the S5000 data sheet: http://www.dell.com/us/enterprise/p/force10-s-series/pd. Installing the SFP+ and QSFP+ Optics The S5000 has 48 small form-factor pluggable plus (SFP+) optical ports and four...
Dell Networking Installation Guide
Page 38
...ports in a default configuration before you can split it into a similarly configured port of supported optics, refer to the S5000 data sheet: http://www.dell.com/us/enterprise/p/force10-s-series/pd. • Configure the system to be in links between peer switches. There are labeled 48 and 56 for...stacking ports. The QSFP+ ports are no unique stacking ports; The range is 0. - Enter the port number of the stack member to stack an S5000 unit. • The quad port must reload the system after issuing the CLI change . The range is lost in a single stack. port - ...
...ports in a default configuration before you can split it into a similarly configured port of supported optics, refer to the S5000 data sheet: http://www.dell.com/us/enterprise/p/force10-s-series/pd. • Configure the system to be in links between peer switches. There are labeled 48 and 56 for...stacking ports. The QSFP+ ports are no unique stacking ports; The range is 0. - Enter the port number of the stack member to stack an S5000 unit. • The quad port must reload the system after issuing the CLI change . The range is lost in a single stack. port - ...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 2
... the United States and other countries. Trademarks used in this text: Dell™, the Dell logo, Dell Boomi™, Dell Precision™ , OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™, EqualLogic™, Compellent™, KACE™, FlexAddress™, Force10™ and Vostro™ are registered trademarks of Intel Corporation in the...
... the United States and other countries. Trademarks used in this text: Dell™, the Dell logo, Dell Boomi™, Dell Precision™ , OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™, EqualLogic™, Compellent™, KACE™, FlexAddress™, Force10™ and Vostro™ are registered trademarks of Intel Corporation in the...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 15
... fip-snooping fcf...445 show fip-snooping sessions...446 show fip-snooping statistics...447 show fip-snooping system...450 show fip-snooping vlan...450 18 Force10 Resilient Ring Protocol (FRRP 451 clear frrp...451 debug frrp...452 member-vlan...453 mode...453 protocol frrp...454 show frrp...454 19 GARP VLAN...
... fip-snooping fcf...445 show fip-snooping sessions...446 show fip-snooping statistics...447 show fip-snooping system...450 show fip-snooping vlan...450 18 Force10 Resilient Ring Protocol (FRRP 451 clear frrp...451 debug frrp...452 member-vlan...453 mode...453 protocol frrp...454 show frrp...454 19 GARP VLAN...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 75
... Mon Jun 10 19:20:42 2030 by default ! show version EXEC Privilege Version 9.0(1.3) Introduced on the S5000. S5000 Syntax Command Modes Command History show version Display the current FTOS version information on the S5000. Dell Force10 Application Fiber Channel Firmware... Version 9-0(1-2) ! boot system stack-unit 0 primary system: B: boot system stack-... on the system. redundancy auto-synchronize full redundancy disable-autoreboot stack-unit output truncated FTOS# show startup-config ! Usage Information Field Dell Force10 Real Time... Dell Force10 Operating...
... Mon Jun 10 19:20:42 2030 by default ! show version EXEC Privilege Version 9.0(1.3) Introduced on the S5000. S5000 Syntax Command Modes Command History show version Display the current FTOS version information on the S5000. Dell Force10 Application Fiber Channel Firmware... Version 9-0(1-2) ! boot system stack-unit 0 primary system: B: boot system stack-... on the system. redundancy auto-synchronize full redundancy disable-autoreboot stack-unit output truncated FTOS# show startup-config ! Usage Information Field Dell Force10 Real Time... Dell Force10 Operating...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 76
... of time the system has been up Image file name Switch type (S5000) Control processor information and amount of memory on processor Amount and type of physical interfaces available FTOS#show version Dell Force10 Real Time Operating System Software Dell Force10 Operating System Version: 2.0 Dell Force10 Application Software Version: 9.0(1.3) Fiber Channel Firmware Version: V10.1.0.00.04 Copyright...
... of time the system has been up Image file name Switch type (S5000) Control processor information and amount of memory on processor Amount and type of physical interfaces available FTOS#show version Dell Force10 Real Time Operating System Software Dell Force10 Operating System Version: 2.0 Dell Force10 Application Software Version: 9.0(1.3) Fiber Channel Firmware Version: V10.1.0.00.04 Copyright...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 130
... +00:00 mani_link flash: 2143281152 bytes total (1482190848 bytes free) FTOS# FTOS#show version Dell Force10 Real Time Operating System Software Dell Force10 Operating System Version: 2.0 Dell Force10 Application Software Version: 9.0(1.3) Fiber Channel Firmware Version: V10.1.0.00.04 Copyright (c) 1999-2013 by Dell Inc. Build Time: Thu Apr 18 11:12:20 PDT 2013 All Rights Reserved... 14 -rwx 69 Nov 28 2012 17:15:20 +00:00 backup_diag_results.txt 15 -rwx 4442 Jan 06 2013 16:29:24 +00:00 pt-s5000-
... +00:00 mani_link flash: 2143281152 bytes total (1482190848 bytes free) FTOS# FTOS#show version Dell Force10 Real Time Operating System Software Dell Force10 Operating System Version: 2.0 Dell Force10 Application Software Version: 9.0(1.3) Fiber Channel Firmware Version: V10.1.0.00.04 Copyright (c) 1999-2013 by Dell Inc. Build Time: Thu Apr 18 11:12:20 PDT 2013 All Rights Reserved... 14 -rwx 69 Nov 28 2012 17:15:20 +00:00 backup_diag_results.txt 15 -rwx 4442 Jan 06 2013 16:29:24 +00:00 pt-s5000-
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 168
...network boot config failure boot zero [primary|secondary|default] zero operating system boot parameters default-gateway default-gateway - S5000 Syntax Command Modes Command History help menu ignore enable-password ignore enable password ignore startup-config ignore system starup-config... -(26%)-Use to continue, q to stop: help display help BOOT USER Version 9.0(1.3) Introduced on the S5000. enable Set the access privilege level. Example BOOT_USER # help ***** Dell Force10 Boot Interface Help Information ***** Current access level: USER LEVEL Use "syntax help Display the Help menu....
...network boot config failure boot zero [primary|secondary|default] zero operating system boot parameters default-gateway default-gateway - S5000 Syntax Command Modes Command History help menu ignore enable-password ignore enable password ignore startup-config ignore system starup-config... -(26%)-Use to continue, q to stop: help display help BOOT USER Version 9.0(1.3) Introduced on the S5000. enable Set the access privilege level. Example BOOT_USER # help ***** Dell Force10 Boot Interface Help Information ***** Current access level: USER LEVEL Use "syntax help Display the Help menu....
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 173
... on the S5000. S5000 Syntax Command Modes Command History show bootflash Display information about the boot parameters used in the operating system. Next ROM bootstrap set to occur from Bootflash partition B. Example BOOT_USER # show bootflash GENERAL BOOTFLASH INFO Bootflash Partition A: Dell Force10 Networks System ..., BSP Release 1.3.1.2 Created Thu May 9 19:24:22 2013 by build on tools-sjc-01 Boot Selector Partition: Dell Force10 Networks System Boot Official S5000_BTSEL_LP_IMG_BOOT_SELECTOR, BSP Release 1.3.0.1 Created Thu May 9 19:24:23 2013 by build on tools-sjc...
... on the S5000. S5000 Syntax Command Modes Command History show bootflash Display information about the boot parameters used in the operating system. Next ROM bootstrap set to occur from Bootflash partition B. Example BOOT_USER # show bootflash GENERAL BOOTFLASH INFO Bootflash Partition A: Dell Force10 Networks System ..., BSP Release 1.3.1.2 Created Thu May 9 19:24:22 2013 by build on tools-sjc-01 Boot Selector Partition: Dell Force10 Networks System Boot Official S5000_BTSEL_LP_IMG_BOOT_SELECTOR, BSP Release 1.3.0.1 Created Thu May 9 19:24:23 2013 by build on tools-sjc...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 451
.... Usage Information Executing this command without having to verify the link status. and speed-independent. • FRRP is a Dell Networking proprietary protocol that does not interoperate with practically no intelligence required of the transit mode. Defaults Command Modes Command History ... Protocol is a proprietary protocol for any other vendor. • Spanning Tree must be disabled on the S5000 switch. 18 Force10 Resilient Ring Protocol (FRRP) Force10 Resilient Ring Protocol (FRRP) is media- Important Points to 255. all the available rings. clear frrp Clear...
.... Usage Information Executing this command without having to verify the link status. and speed-independent. • FRRP is a Dell Networking proprietary protocol that does not interoperate with practically no intelligence required of the transit mode. Defaults Command Modes Command History ... Protocol is a proprietary protocol for any other vendor. • Spanning Tree must be disabled on the S5000 switch. 18 Force10 Resilient Ring Protocol (FRRP) Force10 Resilient Ring Protocol (FRRP) is media- Important Points to 255. all the available rings. clear frrp Clear...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 514
...S5000, the show interface output displays incorrect rate information details over time for link monitoring when the rate-interval is no change in the line-rate. When the maximum line rate is reached, there is configured for 5 seconds. TenGigabitEthern et 0/0... Present pluggable media wavelength, type, and rate. Dell Networking (Force10...) ID is not present, but wavelength information is available from XFP or SFP serial data • Wavelength, F10 unknown-Dell Networking (Force10) ID is ... LineSpeed... Displays the ...
...S5000, the show interface output displays incorrect rate information details over time for link monitoring when the rate-interval is no change in the line-rate. When the maximum line rate is reached, there is configured for 5 seconds. TenGigabitEthern et 0/0... Present pluggable media wavelength, type, and rate. Dell Networking (Force10...) ID is not present, but wavelength information is available from XFP or SFP serial data • Wavelength, F10 unknown-Dell Networking (Force10) ID is ... LineSpeed... Displays the ...
FTOS 9.0(1.3) Command Line Reference Guide for the Switch
Page 820
....131 enterprise.6027.3.3.3 FTOS-1#sh mac accounting access-list WORD interface tengigabitethernet 0/1 in snmpwalk or snmpbulkwalk to access the Force10 MONITOR MIB. show mac accounting {access-list name {interface type slot/ port} {in an increasing order using SNMP via the... Ethernet interface, enter the keyword tengigabitethernet followed by slot/port numbers. S5000 Syntax Parameters show mac accounting access-list Display destination counters for Layer 2 traffic (available on the S5000. NOTE: Currently, the Force10 MONITOR MIB does not return the MAC addresses in | out}}} access...
....131 enterprise.6027.3.3.3 FTOS-1#sh mac accounting access-list WORD interface tengigabitethernet 0/1 in snmpwalk or snmpbulkwalk to access the Force10 MONITOR MIB. show mac accounting {access-list name {interface type slot/ port} {in an increasing order using SNMP via the... Ethernet interface, enter the keyword tengigabitethernet followed by slot/port numbers. S5000 Syntax Parameters show mac accounting access-list Display destination counters for Layer 2 traffic (available on the S5000. NOTE: Currently, the Force10 MONITOR MIB does not return the MAC addresses in | out}}} access...
FTOS 9.0(1.3) Configuration Guide for the Switch
Page 11
FIP Snooping in an S5000 Stack 363 Impact on Other Software Features 364 FIP Snooping Prerequisites 364 FIP Snooping Restrictions 365 FIP Snooping Configuration Procedure 366 Displaying FIP Snooping Information 367 FCoE Transit Configuration Example 372 17 Force10 Resilient Ring Protocol (FRRP 375 ...on a Layer 2 Interface 390 Configuring GVRP Registration 390 Configuring a GARP Timer 391 19 High Availability 393 High Availability on S5000 Stacks 393 Hitless Behavior 393 Graceful Restart 394 Software Resiliency 394 System Health Monitoring 394 Failure and Event Logging 394 Hot-...
FIP Snooping in an S5000 Stack 363 Impact on Other Software Features 364 FIP Snooping Prerequisites 364 FIP Snooping Restrictions 365 FIP Snooping Configuration Procedure 366 Displaying FIP Snooping Information 367 FCoE Transit Configuration Example 372 17 Force10 Resilient Ring Protocol (FRRP 375 ...on a Layer 2 Interface 390 Configuring GVRP Registration 390 Configuring a GARP Timer 391 19 High Availability 393 High Availability on S5000 Stacks 393 Hitless Behavior 393 Graceful Restart 394 Software Resiliency 394 System Health Monitoring 394 Failure and Event Logging 394 Hot-...
FTOS 9.0(1.3) Configuration Guide for the Switch
Page 202
... F10BgpM2PathAttrUnknownEntry contains the optional-transitive attribute details. • Query for f10BgpM2LinkLocalNextHopEntry returns default value for the Force10-BGP4-V2-MIB and other MIB documentation. Important Points to Remember • In f10BgpM2AsPathTableEntry table, f10BgpM2AsPathSegmentIndex,... for BGP is not supported. F10BgpM2PeerCapAnnouncedIndex and f10BgpM2PeerCapReceivedIndex are supported. www.dell.com | support.dell.com Local-as "..." BGP4 Management Information Base (MIB) The FORCE10-BGP4-V2-MIB enhances FTOS BGP Management Information Base (MIB) support ...
... F10BgpM2PathAttrUnknownEntry contains the optional-transitive attribute details. • Query for f10BgpM2LinkLocalNextHopEntry returns default value for the Force10-BGP4-V2-MIB and other MIB documentation. Important Points to Remember • In f10BgpM2AsPathTableEntry table, f10BgpM2AsPathSegmentIndex,... for BGP is not supported. F10BgpM2PeerCapAnnouncedIndex and f10BgpM2PeerCapReceivedIndex are supported. www.dell.com | support.dell.com Local-as "..." BGP4 Management Information Base (MIB) The FORCE10-BGP4-V2-MIB enhances FTOS BGP Management Information Base (MIB) support ...