EMC SmartFabric OS10 User Guide Release 10.5.1
Page 570
...if-ma-1/1/1)# do show configuration ! OS Version: 10.5.2.0 Build Version: 10.5.2.0.99999 Build Time: 2020-08-21T05:54:18+0000 System Type: S5248F-VM Architecture: x86_64 Up Time: 4 days 03:46:41 OS10(conf-if-ma-1/1/1)# OS10(config)# ip vrf management OS10(conf-vrf)# interface ... address. For example: management route 10.1.1.0/24 managementethernet Or management route 2::/64 managementethernet 570 Layer 3 Configuration notes All Dell EMC PowerSwitches except MX-Series, S4200-Series, S5200 Series, and Z9332F-ON: Before you assign the management port to a physical interface.
...if-ma-1/1/1)# do show configuration ! OS Version: 10.5.2.0 Build Version: 10.5.2.0.99999 Build Time: 2020-08-21T05:54:18+0000 System Type: S5248F-VM Architecture: x86_64 Up Time: 4 days 03:46:41 OS10(conf-if-ma-1/1/1)# OS10(config)# ip vrf management OS10(conf-vrf)# interface ... address. For example: management route 10.1.1.0/24 managementethernet Or management route 2::/64 managementethernet 570 Layer 3 Configuration notes All Dell EMC PowerSwitches except MX-Series, S4200-Series, S5200 Series, and Z9332F-ON: Before you assign the management port to a physical interface.
EMC SmartFabric OS10 Switch Configuration Guide for VxRail 4.7
Page 3
Table of contents Revisions...2 1 Introduction...5 1.1 Supported switches and operating systems ...6 1.2 Typographical conventions ...6 1.3 Attachments...6 2 Hardware overview...7 2.1 Dell EMC PowerSwitch S5248F-ON ...7 2.2 Dell EMC PowerSwitch S3048-ON...7 2.3 Dell EMC VxRail 14G nodes ...7 2.3.1 Dell EMC VxRail P Series node ...8 2.3.2 Dell EMC VxRail V Series node ...8 2.3.3 Dell EMC VxRail S Series node ...8 2.3.4 Dell EMC VxRail E Series node ...8 2.3.5 VxRail node network adapters...8 3 Topology options ...10 3.1 Dual switch ...10 3.1.1 Dual...
Table of contents Revisions...2 1 Introduction...5 1.1 Supported switches and operating systems ...6 1.2 Typographical conventions ...6 1.3 Attachments...6 2 Hardware overview...7 2.1 Dell EMC PowerSwitch S5248F-ON ...7 2.2 Dell EMC PowerSwitch S3048-ON...7 2.3 Dell EMC VxRail 14G nodes ...7 2.3.1 Dell EMC VxRail P Series node ...8 2.3.2 Dell EMC VxRail V Series node ...8 2.3.3 Dell EMC VxRail S Series node ...8 2.3.4 Dell EMC VxRail E Series node ...8 2.3.5 VxRail node network adapters...8 3 Topology options ...10 3.1 Dual switch ...10 3.1.1 Dual...
EMC SmartFabric OS10 Switch Configuration Guide for VxRail 4.7
Page 4
... 8.2.2 show vlt domain_id backup-link...41 8.2.3 show vlt domain_id mismatch...41 9 Deploy VxRail ...42 9.1 Management network VLAN ID ...43 A Validated components for S5248F-ON using VxRail 4.7 44 A.1 Dell EMC PowerSwitches ...44 A.2 DAC Cables ...44 A.3 VxRail P570 nodes ...44 A.4 VxRail appliance software ...45 B S5248F-ON port groups ...46 C Technical resources ...48 D Support and feedback ...49...
... 8.2.2 show vlt domain_id backup-link...41 8.2.3 show vlt domain_id mismatch...41 9 Deploy VxRail ...42 9.1 Management network VLAN ID ...43 A Validated components for S5248F-ON using VxRail 4.7 44 A.1 Dell EMC PowerSwitches ...44 A.2 DAC Cables ...44 A.3 VxRail P570 nodes ...44 A.4 VxRail appliance software ...45 B S5248F-ON port groups ...46 C Technical resources ...48 D Support and feedback ...49...
EMC SmartFabric OS10 Switch Configuration Guide for VxRail 4.7
Page 6
... in Adobe Acrobat Reader, click the icon in the left pane halfway down the page, then click the icon. 6 Dell EMC SmartFabric OS10 Switch Configuration Guide for VxRail 4.7 and later: 1.2 1.3 Supported Dell EMC PowerSwitches and operating systems Typographical conventions The CLI and GUI examples in this deployment guide use the following switches and... GUI fields and information entered in the GUI Attachments This document in CLI examples Bold Monospace Text Commands entered at the CLI prompt, or to S5248F-ON switches running Dell EMC SmartFabric OS10.
... in Adobe Acrobat Reader, click the icon in the left pane halfway down the page, then click the icon. 6 Dell EMC SmartFabric OS10 Switch Configuration Guide for VxRail 4.7 and later: 1.2 1.3 Supported Dell EMC PowerSwitches and operating systems Typographical conventions The CLI and GUI examples in this deployment guide use the following switches and... GUI fields and information entered in the GUI Attachments This document in CLI examples Bold Monospace Text Commands entered at the CLI prompt, or to S5248F-ON switches running Dell EMC SmartFabric OS10.
EMC SmartFabric OS10 Switch Configuration Guide for VxRail 4.7
Page 7
... A contains a complete listing of -band (OOB) management traffic. 2.3 Dell EMC PowerSwitch S3048-ON Dell EMC VxRail 14G nodes Current Dell EMC VxRail P, V, S, and E Series nodes are built on 14th generation (14G) PowerEdge servers. Dell EMC PowerSwitch S5248F-ON The S5248F-ON is a 1-RU switch with 48x25GbE, 4x100GbE, and 2x200GbE ports. Dell EMC VxRail 2-RU node (P, V, and S Series) VxRail E Series...
... A contains a complete listing of -band (OOB) management traffic. 2.3 Dell EMC PowerSwitch S3048-ON Dell EMC VxRail 14G nodes Current Dell EMC VxRail P, V, S, and E Series nodes are built on 14th generation (14G) PowerEdge servers. Dell EMC PowerSwitch S5248F-ON The S5248F-ON is a 1-RU switch with 48x25GbE, 4x100GbE, and 2x200GbE ports. Dell EMC VxRail 2-RU node (P, V, and S Series) VxRail E Series...
EMC SmartFabric OS10 Switch Configuration Guide for VxRail 4.7
Page 20
...no (default)]:y OS10# reload System configuration has been modified. Note: SmartFabric OS10 at their default configuration using DHCP. Dell EMC PowerSwitches running SmartFabric OS10 can also be reset to their factory default settings. 6.3 Factory default configuration The configuration commands in... the sections that follow begin with S5248F-ON switches at its default settings has Telnet disabled, SSH enabled, Rapid per...
...no (default)]:y OS10# reload System configuration has been modified. Note: SmartFabric OS10 at their default configuration using DHCP. Dell EMC PowerSwitches running SmartFabric OS10 can also be reset to their factory default settings. 6.3 Factory default configuration The configuration commands in... the sections that follow begin with S5248F-ON switches at its default settings has Telnet disabled, SSH enabled, Rapid per...
EMC SmartFabric OS10 Switch Configuration Guide for VxRail 4.7
Page 44
... 2.5.13.3016 21.40.22.21 2.1.8 3.32.32.32 44 Dell EMC SmartFabric OS10 Switch Configuration Guide for S5248F-ON using the information provided below. A A.1 A.2 Validated components for VxRail 4.7 Dell EMC PowerSwitches Switches and operating system versions Qty Item 2 Dell EMC PowerSwitch S5248F-ON leaf switches 1 Dell EMC PowerSwitch S3048-ON management switch OS version 10.5.0.0 10.5.0.0 DAC Cables...
... 2.5.13.3016 21.40.22.21 2.1.8 3.32.32.32 44 Dell EMC SmartFabric OS10 Switch Configuration Guide for S5248F-ON using the information provided below. A A.1 A.2 Validated components for VxRail 4.7 Dell EMC PowerSwitches Switches and operating system versions Qty Item 2 Dell EMC PowerSwitch S5248F-ON leaf switches 1 Dell EMC PowerSwitch S3048-ON management switch OS version 10.5.0.0 10.5.0.0 DAC Cables...
EMC SmartFabric OS10 Switch Configuration Guide for VxRail 4.7
Page 48
... Release 10.5.0 Manuals and documentation for Dell EMC PowerSwitch S3048-ON Manuals and documentation for Dell EMC PowerSwitch S5248F-ON Dell EMC Networking Layer 3 Leaf-Spine Deployment and Best Practices with OS10 Dell EMC VxRail Network Planning Guide Dell EMC VxRail support and documentation (account required) Dell EMC VxRail Support Matrix (account required) Dell EMC VxRail Appliance 4.5.x and 4.7.x Event Code...
... Release 10.5.0 Manuals and documentation for Dell EMC PowerSwitch S3048-ON Manuals and documentation for Dell EMC PowerSwitch S5248F-ON Dell EMC Networking Layer 3 Leaf-Spine Deployment and Best Practices with OS10 Dell EMC VxRail Network Planning Guide Dell EMC VxRail support and documentation (account required) Dell EMC VxRail Support Matrix (account required) Dell EMC VxRail Appliance 4.5.x and 4.7.x Event Code...
VCF on VxRail Multirack Deployment using BGP EVPN
Page 3
... NSX Data Center...9 1.4 Prerequisites...10 1.5 Supported switches and operating systems...10 1.6 Typographical conventions ...10 1.7 Attachments...10 2 Hardware overview...11 2.1 Dell EMC VxRail E560...11 2.2 Dell EMC PowerSwitch S5248F-ON ...11 2.3 Dell EMC PowerSwitch Z9264F-ON...11 2.4 Dell EMC PowerSwitch S3048-ON...12 3 Network transport ...13 3.1 Layer 3 leaf and spine topology...13 3.2 BGP EVPN VXLAN overview ...13 3.2.1 The VXLAN...
... NSX Data Center...9 1.4 Prerequisites...10 1.5 Supported switches and operating systems...10 1.6 Typographical conventions ...10 1.7 Attachments...10 2 Hardware overview...11 2.1 Dell EMC VxRail E560...11 2.2 Dell EMC PowerSwitch S5248F-ON ...11 2.3 Dell EMC PowerSwitch Z9264F-ON...11 2.4 Dell EMC PowerSwitch S3048-ON...12 3 Network transport ...13 3.1 Layer 3 leaf and spine topology...13 3.2 BGP EVPN VXLAN overview ...13 3.2.1 The VXLAN...
VCF on VxRail Multirack Deployment using BGP EVPN
Page 10
... below can be substituted with VLT or BGP EVPN). Dell EMC PowerSwitch S Series 25-100GbE Switches • S5224F-ON, S5232F-ON, S5248F-ON (S5200-ON Spec Sheet) Dell EMC PowerSwitch S Series 10-40GbE Switches • S4048T-ON •... and GUI examples in this deployment guide. 1.4 1.5 1.6 1.7 Prerequisites This deployment guide is a continuation of Dell PowerSwitch devices supports L2 VXLAN (Static VXLAN with minor changes and create a generally similar outcome outlined in the left pane...at the CLI prompt, or to Dell EMC PowerSwitch S5248F-ON switches running Dell EMC OS10 EE 10.4.3.5.
... below can be substituted with VLT or BGP EVPN). Dell EMC PowerSwitch S Series 25-100GbE Switches • S5224F-ON, S5232F-ON, S5248F-ON (S5200-ON Spec Sheet) Dell EMC PowerSwitch S Series 10-40GbE Switches • S4048T-ON •... and GUI examples in this deployment guide. 1.4 1.5 1.6 1.7 Prerequisites This deployment guide is a continuation of Dell PowerSwitch devices supports L2 VXLAN (Static VXLAN with minor changes and create a generally similar outcome outlined in the left pane...at the CLI prompt, or to Dell EMC PowerSwitch S5248F-ON switches running Dell EMC OS10 EE 10.4.3.5.
VCF on VxRail Multirack Deployment using BGP EVPN
Page 11
...validate the deployment examples in this document uses two Z9264F-ON switches as leaf switches. 2.3 Dell EMC PowerSwitch S5248F-ON Dell EMC PowerSwitch Z9264F-ON The Dell EMC PowerSwitch Z9264F-ON is used for other two ports are provided through a PCI-E expansion card. The...VLT pairs as spine switches. The example within this document uses four VxRail E560 nodes. 2.2 Dell EMC VxRail 1-RU node Dell EMC PowerSwitch S5248F-ON The Dell EMC PowerSwitch S5248F-ON is validated for upstream connectivity. 2 2.1 Hardware overview This section briefly describes the hardware...
...validate the deployment examples in this document uses two Z9264F-ON switches as leaf switches. 2.3 Dell EMC PowerSwitch S5248F-ON Dell EMC PowerSwitch Z9264F-ON The Dell EMC PowerSwitch Z9264F-ON is used for other two ports are provided through a PCI-E expansion card. The...VLT pairs as spine switches. The example within this document uses four VxRail E560 nodes. 2.2 Dell EMC VxRail 1-RU node Dell EMC PowerSwitch S5248F-ON The Dell EMC PowerSwitch S5248F-ON is validated for upstream connectivity. 2 2.1 Hardware overview This section briefly describes the hardware...
VCF on VxRail Multirack Deployment using BGP EVPN
Page 16
...leaf switches per rack, this topology scales to be active while also providing fault tolerance. For more leaf-spine network information, see Dell EMC PowerSwitch Layer 3 Leaf-Spine Deployment and Best Practices with OS10. BGP is at the top of each rack. Connections within racks from hosts... Deployment using a VLT port-channel. There are used to each host is connected using BGP EVPN With Z9264F-ON switches as spines, and four S5248F-ON switches are some BGP configuration differences in Rack 1 and Rack 2. 4 Topology 4.1 Leaf-spine underlay In a Layer 3 leaf-spine network,...
...leaf switches per rack, this topology scales to be active while also providing fault tolerance. For more leaf-spine network information, see Dell EMC PowerSwitch Layer 3 Leaf-Spine Deployment and Best Practices with OS10. BGP is at the top of each rack. Connections within racks from hosts... Deployment using a VLT port-channel. There are used to each host is connected using BGP EVPN With Z9264F-ON switches as spines, and four S5248F-ON switches are some BGP configuration differences in Rack 1 and Rack 2. 4 Topology 4.1 Leaf-spine underlay In a Layer 3 leaf-spine network,...
VCF on VxRail Multirack Deployment using BGP EVPN
Page 24
... recommends upgrading to check the OS version. Run the show license status System Information Vendor Name : Dell EMC Product Name : S5248F-ON Hardware Version : A01 Platform Name : x86_64-dellemc_s5248f_c3538-r0 PPID : CN046MRJCES0089K0004 Service Tag : 68X00Q2 Product Base : Product Serial Number: Product Part Number : License Details Software : ... mask 172.25.101.199 172.25.101.253 /24 172.25.102.199 172.25.102.253 /24 5.4 Switch preparation 5.5 Check switch OS version Dell EMC PowerSwitches must be running OS10EE version 10.4.3.5 or later for download on...
... recommends upgrading to check the OS version. Run the show license status System Information Vendor Name : Dell EMC Product Name : S5248F-ON Hardware Version : A01 Platform Name : x86_64-dellemc_s5248f_c3538-r0 PPID : CN046MRJCES0089K0004 Service Tag : 68X00Q2 Product Base : Product Serial Number: Product Part Number : License Details Software : ... mask 172.25.101.199 172.25.101.253 /24 172.25.102.199 172.25.102.253 /24 5.4 Switch preparation 5.5 Check switch OS version Dell EMC PowerSwitches must be running OS10EE version 10.4.3.5 or later for download on...
VCF on VxRail Multirack Deployment using BGP EVPN
Page 59
... Switches and operating system versions Qty Item 4 Dell EMC PowerSwitch S5248F-ON leaf switches 2 Dell EMC PowerSwitch Z9264F-ON spine switches 2 Dell EMC PowerSwitch S3048-ON OOB mgmt switches Version 10.4.3.5 10.4.3.5 10.4.3.5 A.2 VxRail E560 nodes A cluster of four VxRail E560 nodes...Xeon Gold 6136 CPU @ 3.00GHz, 12 cores - 12 16GB DDR4 DIMMs (192GB total) - 2 800GB SAS SSD - 8 1.2TB SAS HDD EF03 1 Dell HBA330 Storage Controller 15.17.09.06 1 Boot Optimized Storage Solution (BOSS) 2.5.13.3016 Controller w/ 2x240GB SATA SSDs 1 Broadcom 57414 NDC - 2x25GbE SFP28 ...
... Switches and operating system versions Qty Item 4 Dell EMC PowerSwitch S5248F-ON leaf switches 2 Dell EMC PowerSwitch Z9264F-ON spine switches 2 Dell EMC PowerSwitch S3048-ON OOB mgmt switches Version 10.4.3.5 10.4.3.5 10.4.3.5 A.2 VxRail E560 nodes A cluster of four VxRail E560 nodes...Xeon Gold 6136 CPU @ 3.00GHz, 12 cores - 12 16GB DDR4 DIMMs (192GB total) - 2 800GB SAS SSD - 8 1.2TB SAS HDD EF03 1 Dell HBA330 Storage Controller 15.17.09.06 1 Boot Optimized Storage Solution (BOSS) 2.5.13.3016 Controller w/ 2x240GB SATA SSDs 1 Broadcom 57414 NDC - 2x25GbE SFP28 ...
EMC Networking Virtualization Overlay with BGP EVPN
Page 3
Table of contents Revisions...2 1 Introduction...6 1.1 Typographical conventions...6 1.2 Attachments...6 2 Hardware Overview...7 2.1 Dell EMC PowerSwitch S5248F-ON ...7 2.2 Dell EMC PowerSwitch S4148U-ON ...7 2.3 Dell EMC PowerSwitch Z9264F-ON...8 2.4 Dell EMC PowerSwitch S3048-ON...8 2.5 Dell EMC PowerEdge R740xd server ...8 3 BGP EVPN VXLAN overview ...9 3.1 The VXLAN protocol...10 3.2 BGP EVPN... configuration ...22 6.4 VLAN configuration...24 6.5 Downstream interface configuration ...25 6.6 Upstream interface configuration...26 3 Dell EMC Networking Virtualization Overlay with BGP EVPN
Table of contents Revisions...2 1 Introduction...6 1.1 Typographical conventions...6 1.2 Attachments...6 2 Hardware Overview...7 2.1 Dell EMC PowerSwitch S5248F-ON ...7 2.2 Dell EMC PowerSwitch S4148U-ON ...7 2.3 Dell EMC PowerSwitch Z9264F-ON...8 2.4 Dell EMC PowerSwitch S3048-ON...8 2.5 Dell EMC PowerEdge R740xd server ...8 3 BGP EVPN VXLAN overview ...9 3.1 The VXLAN protocol...10 3.2 BGP EVPN... configuration ...22 6.4 VLAN configuration...24 6.5 Downstream interface configuration ...25 6.6 Upstream interface configuration...26 3 Dell EMC Networking Virtualization Overlay with BGP EVPN
EMC Networking Virtualization Overlay with BGP EVPN
Page 7
... tunnels (RIOT). As of the hardware and software validated for 25GbE and 10GbE compute and storage. This guide uses two S5248F-ONs as leaf switches. 2.2 Dell EMC PowerSwitch S5248F-ON Dell EMC PowerSwitch S4148U-ON The Dell EMC PowerSwitch S4148U-ON is a 1-RU, multilayer switch with forty-eight SFP28 25GbE ports, two QSFP28-DD ports (two 100GbE interfaces...
... tunnels (RIOT). As of the hardware and software validated for 25GbE and 10GbE compute and storage. This guide uses two S5248F-ONs as leaf switches. 2.2 Dell EMC PowerSwitch S5248F-ON Dell EMC PowerSwitch S4148U-ON The Dell EMC PowerSwitch S4148U-ON is a 1-RU, multilayer switch with forty-eight SFP28 25GbE ports, two QSFP28-DD ports (two 100GbE interfaces...
EMC Networking Virtualization Overlay with BGP EVPN
Page 12
...add racks to the data center, two leaf switches configured for the network underlay. For additional leaf-spine network information, refer to Dell EMC PowerSwitch Layer 3 Leaf-Spine Deployment and Best Practices with BGP EVPN Two leaf switches are configured as leafs in this deployment example, any ... purposes, there is used as shown in the data center is routed. L3 Connection L2 Connection ZS9p2i6n4eF1-1 ZS9p26in4eF-2 ECMP L3 L2 S5248F-1a VLTi S5248F-1b Rack 1 VLT S4148U-2a VLTi S4148U-2b Rack 2 VLT Host Leaf-spine underlay network Host Border Leafs S4148U-3a VLTi ...
...add racks to the data center, two leaf switches configured for the network underlay. For additional leaf-spine network information, refer to Dell EMC PowerSwitch Layer 3 Leaf-Spine Deployment and Best Practices with BGP EVPN Two leaf switches are configured as leafs in this deployment example, any ... purposes, there is used as shown in the data center is routed. L3 Connection L2 Connection ZS9p2i6n4eF1-1 ZS9p26in4eF-2 ECMP L3 L2 S5248F-1a VLTi S5248F-1b Rack 1 VLT S4148U-2a VLTi S4148U-2b Rack 2 VLT Host Leaf-spine underlay network Host Border Leafs S4148U-3a VLTi ...
EMC Networking Virtualization Overlay with BGP EVPN
Page 64
....26.22 VMware software VMware software versions Item Version VMware ESXi 6.7.0 Update 1 build 10764712 - Dell EMC PowerSwitches Switches and OS versions Qty Item 2 Dell EMC PowerSwitch S5248F-ON leaf switch 4 Dell EMC PowerSwitch S4148U-ON leaf switch 2 Dell EMC PowerSwitch Z9264-ON spine switch 1 Dell EMC PowerSwitch S3048-ON management switch OS Version 10.4.3.1.154 10.4.3.1.154 10.4.3.1.154 10.4.3.1.154...
....26.22 VMware software VMware software versions Item Version VMware ESXi 6.7.0 Update 1 build 10764712 - Dell EMC PowerSwitches Switches and OS versions Qty Item 2 Dell EMC PowerSwitch S5248F-ON leaf switch 4 Dell EMC PowerSwitch S4148U-ON leaf switch 2 Dell EMC PowerSwitch Z9264-ON spine switch 1 Dell EMC PowerSwitch S3048-ON management switch OS Version 10.4.3.1.154 10.4.3.1.154 10.4.3.1.154 10.4.3.1.154...
EMC Networking Virtualization Overlay with BGP EVPN
Page 65
...-Spine Deployment and Best Practices with OS10 Manuals and documentation for Dell EMC PowerSwitch S3048-ON Manuals and documentation for Dell EMC PowerSwitch S4148U-ON Manuals and documentation for Dell EMC PowerSwitch S5248F-ON Manuals and documentation for Dell EMC PowerSwitch Z9264F-ON Manuals and documentation for Dell EMC PowerEdge R740xd VMware product manuals and technical guides VMware vSphere Documentation...
...-Spine Deployment and Best Practices with OS10 Manuals and documentation for Dell EMC PowerSwitch S3048-ON Manuals and documentation for Dell EMC PowerSwitch S4148U-ON Manuals and documentation for Dell EMC PowerSwitch S5248F-ON Manuals and documentation for Dell EMC PowerSwitch Z9264F-ON Manuals and documentation for Dell EMC PowerEdge R740xd VMware product manuals and technical guides VMware vSphere Documentation...
EMC Networking OS10EE FCoE Deployment with FSB
Page 8
...-eight 1GbE BASE-T ports and four 10GbE SFP+ ports. At the date of this document. Note: While the steps in this document. 2.1.1 Dell EMC PowerSwitch S5248-ON The Dell EMC PowerSwitch S5248F-ON is a 1-Rack Unit (RU) switch with forty-eight 25GbE SFP28 ports, two 2x100GbE QSFP28-DD ports, and four 100GbE QSFP28 ports. Appendix...
...-eight 1GbE BASE-T ports and four 10GbE SFP+ ports. At the date of this document. Note: While the steps in this document. 2.1.1 Dell EMC PowerSwitch S5248-ON The Dell EMC PowerSwitch S5248F-ON is a 1-Rack Unit (RU) switch with forty-eight 25GbE SFP28 ports, two 2x100GbE QSFP28-DD ports, and four 100GbE QSFP28 ports. Appendix...